Setting Up EMC PowerEdge Server Using Lifecycle Controller
Page 2
...make configuration changes later, restart the server, press F10 to iDRAC. a. Pull out the information tag available at https://www.dell.com/idracmanuals. SupportAssist 1. 1 Topics: • Setting Up Dell EMC PowerEdge Server Using Lifecycle Controller Setting Up Dell EMC PowerEdge Server Using Lifecycle Controller 1. Power on ...the instructions on the SupportAssist Registration wizard. 2 Click OS Deployment > Deploy OS and follow the instructions on the server and press F10 to open Lifecycle Controller, and select Settings or System Setup from the Lifecycle Controller home page. ...
...make configuration changes later, restart the server, press F10 to iDRAC. a. Pull out the information tag available at https://www.dell.com/idracmanuals. SupportAssist 1. 1 Topics: • Setting Up Dell EMC PowerEdge Server Using Lifecycle Controller Setting Up Dell EMC PowerEdge Server Using Lifecycle Controller 1. Power on ...the instructions on the SupportAssist Registration wizard. 2 Click OS Deployment > Deploy OS and follow the instructions on the server and press F10 to open Lifecycle Controller, and select Settings or System Setup from the Lifecycle Controller home page. ...
Setting Up EMC PowerEdge Server Using Lifecycle Controller
Page 3
...the host operating system for 30 minutes. Related Dell products ● Integrated Dell Remote Access Controller With Lifecycle Controller For related documentation, go to https://www.dell.com/idracmanuals. ● OpenManage Server Administrator (OMSA)/OpenManage Storage Services (OMSS) For... installation instructions, see the Systems Management Tools And Documentation Installation Guide and Server Administrator Installation Guideat https:// www.dell.com/openmanagemanuals and click OpenManage Server Administrator. The Service Module installer is displayed as Installed and the installation ...
...the host operating system for 30 minutes. Related Dell products ● Integrated Dell Remote Access Controller With Lifecycle Controller For related documentation, go to https://www.dell.com/idracmanuals. ● OpenManage Server Administrator (OMSA)/OpenManage Storage Services (OMSS) For... installation instructions, see the Systems Management Tools And Documentation Installation Guide and Server Administrator Installation Guideat https:// www.dell.com/openmanagemanuals and click OpenManage Server Administrator. The Service Module installer is displayed as Installed and the installation ...
EMC PMem 200 Series Users Guide
Page 3
Contents Chapter 1: Introduction...5 System requirements...5 Terminology...6 Chapter 2: Change list...7 Chapter 3: Hardware...8 Server hardware configuration...8 DIMM installation and removal...8 PMem hardware configuration...8 PMem recommended topologies...8 Processor type and maximum memory limits...13 PMem mixing and population rules...13 ...
Contents Chapter 1: Introduction...5 System requirements...5 Terminology...6 Chapter 2: Change list...7 Chapter 3: Hardware...8 Server hardware configuration...8 DIMM installation and removal...8 PMem hardware configuration...8 PMem recommended topologies...8 Processor type and maximum memory limits...13 PMem mixing and population rules...13 ...
EMC PMem 200 Series Users Guide
Page 5
... commands. PMems come in Dell EMC PowerEdge systems. It covers the fundamentals of installation and configuration of the server and are inherently persistent. ...System requirements Component System Processor BIOS CPLD iDRAC PMem firmware Minimum version required R650, R750, R750xa, MX750c, XR11, XR12 3rd Generation Intel Xeon Platinum or Gold processors R650 - 1.1.1 R750 - 1.1.1 R750xa - 1.1.1 MX750c - 1.1.2 XR11, XR12 - 1.0.2 R650 - 1.0.1 R750 - 1.0.1 R750xa...
... commands. PMems come in Dell EMC PowerEdge systems. It covers the fundamentals of installation and configuration of the server and are inherently persistent. ...System requirements Component System Processor BIOS CPLD iDRAC PMem firmware Minimum version required R650, R750, R750xa, MX750c, XR11, XR12 3rd Generation Intel Xeon Platinum or Gold processors R650 - 1.1.1 R750 - 1.1.1 R750xa - 1.1.1 MX750c - 1.1.2 XR11, XR12 - 1.0.2 R650 - 1.0.1 R750 - 1.0.1 R750xa...
EMC PMem 200 Series Users Guide
Page 6
Tebibyte 1 TiB = 1024 GiB Terabyte 1 TB = 1000 GB 6 Introduction System requirements (continued) Component Minimum version required OS Microsoft Windows Server 2019 VMware ESXi 7.0 Update 2 Red Hat Enterprise Linux 8.2 SUSE Linux Enterprise Server 15 SP2 Terminology Table 2. This is essentially "Noninterleaved" Persistent Memory RDIMM or LRDIMM becomes cache for nonpersistent PMems. Mibibyte 1 MiB = 1024...
Tebibyte 1 TiB = 1024 GiB Terabyte 1 TB = 1000 GB 6 Introduction System requirements (continued) Component Minimum version required OS Microsoft Windows Server 2019 VMware ESXi 7.0 Update 2 Red Hat Enterprise Linux 8.2 SUSE Linux Enterprise Server 15 SP2 Terminology Table 2. This is essentially "Noninterleaved" Persistent Memory RDIMM or LRDIMM becomes cache for nonpersistent PMems. Mibibyte 1 MiB = 1024...
EMC PMem 200 Series Users Guide
Page 8
...not followed, the system may not have sufficient power holdup in an AC loss scenario to flush in R650, R750, R750xa, MX750c, XR11 and XR12 PowerEdge servers with more details on PMem configuration and provisioning concepts. JEDEC Standards (www.jedec.org): Document Number SPP-023B. For ...in -flight data contents to persistent media. Four-socket configurations are recommended per processor socket. All systems built from Dell Technologies factories will be followed while handling, installing, or removing PMem memories. NOTE: The following topologies are a direct scale up of ...
...not followed, the system may not have sufficient power holdup in an AC loss scenario to flush in R650, R750, R750xa, MX750c, XR11 and XR12 PowerEdge servers with more details on PMem configuration and provisioning concepts. JEDEC Standards (www.jedec.org): Document Number SPP-023B. For ...in -flight data contents to persistent media. Four-socket configurations are recommended per processor socket. All systems built from Dell Technologies factories will be followed while handling, installing, or removing PMem memories. NOTE: The following topologies are a direct scale up of ...
EMC PMem 200 Series Users Guide
Page 10
..., 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 15, 16} Processor2 {B1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 15, 16} Processor1 {A5, 6} Processor2 {B5, 6} NOTE: There are limited configurations available for dual socket servers with only one processor populated. Table 5.
..., 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 15, 16} Processor2 {B1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 15, 16} Processor1 {A5, 6} Processor2 {B5, 6} NOTE: There are limited configurations available for dual socket servers with only one processor populated. Table 5.
EMC PMem 200 Series Users Guide
Page 21
The Info server has automatically taken corrective action and the device is provided in the memory device at . MEM5101 A diagnostic event occurred in the table. 5 PMem event reporting ... and SEL) ○ 7 = Critical (LC log and SEL) ● Y - If an event is frequently used in the memory device at . MEM5102 A diagnostic event occurred in Server System Event Log(SEL) and Life-Cycle Log(LCL).
The Info server has automatically taken corrective action and the device is provided in the memory device at . MEM5101 A diagnostic event occurred in the table. 5 PMem event reporting ... and SEL) ○ 7 = Critical (LC log and SEL) ● Y - If an event is frequently used in the memory device at . MEM5102 A diagnostic event occurred in Server System Event Log(SEL) and Life-Cycle Log(LCL).
EMC PMem 200 Series Users Guide
Page 23
...Remaining Rated Endurance value of NVDIMM located in the Persistent Memory (PM) region may not be accessible. Recommended Action : Power off the server and replace the NVDIMM immediately. For more information about NVDIMMs, see the product Installation and Service Manual available on the support site. ...configuration of all the installed NVDIMMs has exceeded the maximum value supported by the processor. Recommended Action : Power off the server and replace the NVDIMMs to ensure all NVDIMM SKUs or controller revisions are installed in the memory slot is corrupted because ...
...Remaining Rated Endurance value of NVDIMM located in the Persistent Memory (PM) region may not be accessible. Recommended Action : Power off the server and replace the NVDIMM immediately. For more information about NVDIMMs, see the product Installation and Service Manual available on the support site. ...configuration of all the installed NVDIMMs has exceeded the maximum value supported by the processor. Recommended Action : Power off the server and replace the NVDIMMs to ensure all NVDIMM SKUs or controller revisions are installed in the memory slot is corrupted because ...
EMC PMem 200 Series Users Guide
Page 24
...Memory Passphrase to initialize. Recommended Action : N/A ● UEFI0358 : Unable to apply the Persistent Memory (PM) region configuration of the server available on the Intel Persistent Memory DIMM with serial number in slot . Recommended Action : N/A ● UEFI0370 : The Complex Programmable Logic...: The NVDIMM installed in the memory slot . Recommended Action : Reboot the system. Recommended Action : Turn off the server and replace the NVDIMM immediately. For more information about the Remaining Rated Endurance, see the platform Installation and Service Manual ...
...Memory Passphrase to initialize. Recommended Action : N/A ● UEFI0358 : Unable to apply the Persistent Memory (PM) region configuration of the server available on the Intel Persistent Memory DIMM with serial number in slot . Recommended Action : N/A ● UEFI0370 : The Complex Programmable Logic...: The NVDIMM installed in the memory slot . Recommended Action : Reboot the system. Recommended Action : Turn off the server and replace the NVDIMM immediately. For more information about the Remaining Rated Endurance, see the platform Installation and Service Manual ...
EMC PMem 200 Series Users Guide
Page 25
... Action : Do one of the following and retry the operation: ○ Turn off the server. 2) Disconnect the input power, wait for 30 seconds, and then reconnect to the power source. 3) Power on the server. 4) If the issue persists, contact your service provider. ● PWR2281 : Unable to perform... the memory arming operation because the PSU configuration of the server is insufficient to guarantee data flush time in the event of the system available on the server. For more information on supported PSUs, see the Installation and Service Manual of power loss....
... Action : Do one of the following and retry the operation: ○ Turn off the server. 2) Disconnect the input power, wait for 30 seconds, and then reconnect to the power source. 3) Power on the server. 4) If the issue persists, contact your service provider. ● PWR2281 : Unable to perform... the memory arming operation because the PSU configuration of the server is insufficient to guarantee data flush time in the event of the system available on the server. For more information on supported PSUs, see the Installation and Service Manual of power loss....
EMC PMem 200 Series Users Guide
Page 29
...security reconfiguration. The passphrase to data stored on the PMem in App-direct is used to attempt to another server, the user must be cleared by the Dell BIOS and operating system level security changes including Passphrase management and PMem erasing functions will not reprompt for slot ... configurable in BIOS setup before booting to the operating system or UEFI Shell. PMem security 29 If the PMems are moved from one server to unlock all security changes are related to unsupported migration scenarios: ● When changing passphrase in the system. This means that is...
...security reconfiguration. The passphrase to data stored on the PMem in App-direct is used to attempt to another server, the user must be cleared by the Dell BIOS and operating system level security changes including Passphrase management and PMem erasing functions will not reprompt for slot ... configurable in BIOS setup before booting to the operating system or UEFI Shell. PMem security 29 If the PMems are moved from one server to unlock all security changes are related to unsupported migration scenarios: ● When changing passphrase in the system. This means that is...
EMC PMem 200 Series Users Guide
Page 33
.... It is set on Intel PMem must use BIOS Setup to an existing PMem configuration is protected with the PMem would be lost. Once the server is replaced. The goal creation process deletes all PMem data to the same configuration as the original board. 8 DIMM configuration changes The following PMem migration...
.... It is set on Intel PMem must use BIOS Setup to an existing PMem configuration is protected with the PMem would be lost. Once the server is replaced. The goal creation process deletes all PMem data to the same configuration as the original board. 8 DIMM configuration changes The following PMem migration...
EMC PMem 200 Series Users Guide
Page 37
PMem disk with the interleave set, "App-direct Interleave" should be displayed as a single logical disk to windows server. Windows 37 For PMem Disk with interleave sets Interleaved sets can create PMem Disk also using B7, B8. Figure 21. PMem Disk creation with interleave ... information about storage spaces method refer to create redundant volumes, use the storage spaces method. In order to : https://docs.microsoft.com/en-us/windows-server/storage/storagespaces/deploy-standalone-storage-spaces.
PMem disk with the interleave set, "App-direct Interleave" should be displayed as a single logical disk to windows server. Windows 37 For PMem Disk with interleave sets Interleaved sets can create PMem Disk also using B7, B8. Figure 21. PMem Disk creation with interleave ... information about storage spaces method refer to create redundant volumes, use the storage spaces method. In order to : https://docs.microsoft.com/en-us/windows-server/storage/storagespaces/deploy-standalone-storage-spaces.
EMC PMem 200 Series Users Guide
Page 39
Workaround: None. Windows 39 Windows troubleshooting and event monitoring Windows Errata The following errata affects Windows OSes and are expected to be fixed in a future OS patch. ● When a namespace is created in Windows Server 2019 (WS2019), the logged message appears as WAD for persistent memory disk encounters internal error". The error is considered as "The driver for WS2019. This means the namespace is created, and is expected and it may occur during testing of Storage Class Memory (SCM) device. Figure 24.
Workaround: None. Windows 39 Windows troubleshooting and event monitoring Windows Errata The following errata affects Windows OSes and are expected to be fixed in a future OS patch. ● When a namespace is created in Windows Server 2019 (WS2019), the logged message appears as WAD for persistent memory disk encounters internal error". The error is considered as "The driver for WS2019. This means the namespace is created, and is expected and it may occur during testing of Storage Class Memory (SCM) device. Figure 24.
EMC PMem 200 Series Users Guide
Page 45
...Storage. VMware ESXi 45 ESXi troubleshooting and maintenance NOTE: Go through/var/log/vmkernel.log to see if there are configured in the system. Dell EMC does not support Non-interleaved App Direct goals with PMems in is not supported for now. ● ESXi displays more number of the...memory goals are attached to persistent memory. The log entries related to persistent memory would be displayed as Non-interleaved App Direct. The host server is a critical error to App Direct mode, PMem datastore does not mount automatically in sequence from App Direct mode to Memory mode and back...
...Storage. VMware ESXi 45 ESXi troubleshooting and maintenance NOTE: Go through/var/log/vmkernel.log to see if there are configured in the system. Dell EMC does not support Non-interleaved App Direct goals with PMems in is not supported for now. ● ESXi displays more number of the...memory goals are attached to persistent memory. The log entries related to persistent memory would be displayed as Non-interleaved App Direct. The host server is a critical error to App Direct mode, PMem datastore does not mount automatically in sequence from App Direct mode to Memory mode and back...
EMC PMem 200 Series Users Guide
Page 47
... latest version before applying PMem DUP. 1. The system will be updated using Lifecycle Controller see: Lifecycle Controller User's Guide available at https://www.dell.com/idracmanuals . NOTE: Make sure BIOS is not accessible, log in to the operating system and execute DUP package. Boot to iDRAC. System... update via iDRAC 3. Firmware update 47 On a Windows system, double click the .exe DUP file. Select FTP server or local drive that contains DUP bin file ii. 13 Firmware update Topics: • Dell DUP update Dell DUP update Download PMem DUP from www...
... latest version before applying PMem DUP. 1. The system will be updated using Lifecycle Controller see: Lifecycle Controller User's Guide available at https://www.dell.com/idracmanuals . NOTE: Make sure BIOS is not accessible, log in to the operating system and execute DUP package. Boot to iDRAC. System... update via iDRAC 3. Firmware update 47 On a Windows system, double click the .exe DUP file. Select FTP server or local drive that contains DUP bin file ii. 13 Firmware update Topics: • Dell DUP update Dell DUP update Download PMem DUP from www...
EMC Installation and Service Manual
Page 17
... Manufacture Date (Mfg. Alternatively, the Service Tag information is located on the left wall of the system cover. Figure 9. Information tag (front view) 2. Service information Dell EMC PowerEdge R750xa system overview 17 iDRAC MAC address and iDRAC secure password label 5. Date). System information label The system information label is used by... on the back side of the chassis. 2, the Information tag also contains the OpenManage Mobile (OMM) label, where administrators can configure, monitor, and troubleshoot the PowerEdge servers.
... Manufacture Date (Mfg. Alternatively, the Service Tag information is located on the left wall of the system cover. Figure 9. Information tag (front view) 2. Service information Dell EMC PowerEdge R750xa system overview 17 iDRAC MAC address and iDRAC secure password label 5. Date). System information label The system information label is used by... on the back side of the chassis. 2, the Information tag also contains the OpenManage Mobile (OMM) label, where administrators can configure, monitor, and troubleshoot the PowerEdge servers.
EMC Installation and Service Manual
Page 21
... reduces the need for physical access to https://www.dell.com/poweredgemanuals > Product Support page of Dell EMC servers. You can set up iDRAC IP address Interface iDRAC Settings utility Documentation links Integrated Dell Remote Access Controller User's Guide at www.dell.com/poweredgemanuals. 3. Table 7. The section also provides... at the time of the system, see the Getting Started Guide that is set to set up the system, see the Dell EMC PowerEdge R750xa BIOS and UEFI Reference Guide on the system. Interfaces to set up iDRAC IP address, see the rail installation and cable ...
... reduces the need for physical access to https://www.dell.com/poweredgemanuals > Product Support page of Dell EMC servers. You can set up iDRAC IP address Interface iDRAC Settings utility Documentation links Integrated Dell Remote Access Controller User's Guide at www.dell.com/poweredgemanuals. 3. Table 7. The section also provides... at the time of the system, see the Getting Started Guide that is set to set up the system, see the Dell EMC PowerEdge R750xa BIOS and UEFI Reference Guide on the system. Interfaces to set up iDRAC IP address, see the rail installation and cable ...
EMC Installation and Service Manual
Page 22
Server LCD panel iDRAC Direct and Quick Sync 2 (optional) LCD panel section. Integrated Dell Remote Access Controller User's Guide at https://www.dell.com/idracmanuals or for system specific Integrated Dell Remote Access Controller User's Guide, go to https://www.dell.com/poweredgemanuals > Product Support ...- Table 7. You can log in by using your platform and for latest documentation version, see KB article https://www.dell.com/support/article/ sln308699. NOTE: To determine the most recent iDRAC release for your platform and for latest documentation version...
Server LCD panel iDRAC Direct and Quick Sync 2 (optional) LCD panel section. Integrated Dell Remote Access Controller User's Guide at https://www.dell.com/idracmanuals or for system specific Integrated Dell Remote Access Controller User's Guide, go to https://www.dell.com/poweredgemanuals > Product Support ...- Table 7. You can log in by using your platform and for latest documentation version, see KB article https://www.dell.com/support/article/ sln308699. NOTE: To determine the most recent iDRAC release for your platform and for latest documentation version...