Setting Up EMC PowerEdge Server Using Lifecycle Controller
Page 2
... and follow the instructions on the screen. NOTE: If you open Lifecycle Controller for the first time. 1 Topics: • Setting Up Dell EMC PowerEdge Server Using Lifecycle Controller Setting Up Dell EMC PowerEdge Server Using Lifecycle Controller 1. NOTE: If you require it to log in the iDRAC and Lifecycle Controller User's Guide, available at the front...
... and follow the instructions on the screen. NOTE: If you open Lifecycle Controller for the first time. 1 Topics: • Setting Up Dell EMC PowerEdge Server Using Lifecycle Controller Setting Up Dell EMC PowerEdge Server Using Lifecycle Controller 1. NOTE: If you require it to log in the iDRAC and Lifecycle Controller User's Guide, available at the front...
Setting Up EMC PowerEdge Server Using Lifecycle Controller
Page 3
...the security warning. 4. Find the mounted volume labeled as "SMINST" on the screen to https://www.dell.com/support and type OpenManage DVD in to the server either remotely or locally. 3. On the iDRAC Service Module Setup page, click Install Service Module. 3. ...Management ISO and installation instructions, see the Systems Management Tools And Documentation Installation Guide and Server Administrator Installation Guideat https:// www.dell.com/openmanagemanuals and click OpenManage Server Administrator. iDRAC Service Module You can install iDRAC Service Module using: iDRAC Express or ...
...the security warning. 4. Find the mounted volume labeled as "SMINST" on the screen to https://www.dell.com/support and type OpenManage DVD in to the server either remotely or locally. 3. On the iDRAC Service Module Setup page, click Install Service Module. 3. ...Management ISO and installation instructions, see the Systems Management Tools And Documentation Installation Guide and Server Administrator Installation Guideat https:// www.dell.com/openmanagemanuals and click OpenManage Server Administrator. iDRAC Service Module You can install iDRAC Service Module using: iDRAC Express or ...
EMC PMem 200 Series Users Guide
Page 3
Contents Chapter 1: Introduction...5 System requirements...5 Terminology...6 Chapter 2: Change list...7 Chapter 3: Hardware...8 Server hardware configuration...8 DIMM installation and removal...8 PMem hardware configuration...8 PMem recommended topologies...8 Processor type and maximum memory limits...13 PMem mixing and population rules...13 ...
Contents Chapter 1: Introduction...5 System requirements...5 Terminology...6 Chapter 2: Change list...7 Chapter 3: Hardware...8 Server hardware configuration...8 DIMM installation and removal...8 PMem hardware configuration...8 PMem recommended topologies...8 Processor type and maximum memory limits...13 PMem mixing and population rules...13 ...
EMC PMem 200 Series Users Guide
Page 5
...to help customers understand the basics of Intel's PMem technology integrated in Dell EMC PowerEdge systems. It covers the fundamentals of installation and configuration of the server and are inherently persistent. PMems come in two modes: ● Memory.... System requirements Component System Processor BIOS CPLD iDRAC PMem firmware Minimum version required R650, R750, R750xa, MX750c, XR11, XR12 3rd Generation Intel Xeon Platinum or Gold processors R650 - 1.1.1 R750 - 1.1.1 R750xa - 1.1.1 MX750c - 1.1.2 XR11, XR12 - 1.0.2 R650 - 1.0.1 R750 - 1.0.1 R750xa - 1.0.1 MX750c - 1.0.1 XR11, XR12 ...
...to help customers understand the basics of Intel's PMem technology integrated in Dell EMC PowerEdge systems. It covers the fundamentals of installation and configuration of the server and are inherently persistent. PMems come in two modes: ● Memory.... System requirements Component System Processor BIOS CPLD iDRAC PMem firmware Minimum version required R650, R750, R750xa, MX750c, XR11, XR12 3rd Generation Intel Xeon Platinum or Gold processors R650 - 1.1.1 R750 - 1.1.1 R750xa - 1.1.1 MX750c - 1.1.2 XR11, XR12 - 1.0.2 R650 - 1.0.1 R750 - 1.0.1 R750xa - 1.0.1 MX750c - 1.0.1 XR11, XR12 ...
EMC PMem 200 Series Users Guide
Page 6
... Table 1. Intel command-line interface in the file system. System requirements (continued) Component Minimum version required OS Microsoft Windows Server 2019 VMware ESXi 7.0 Update 2 Red Hat Enterprise Linux 8.2 SUSE Linux Enterprise Server 15 SP2 Terminology Table 2. Terminology Terminology App-direct mode (AD) CLI PMem GiB GB iMC Interleave Set x1 (by applications...
... Table 1. Intel command-line interface in the file system. System requirements (continued) Component Minimum version required OS Microsoft Windows Server 2019 VMware ESXi 7.0 Update 2 Red Hat Enterprise Linux 8.2 SUSE Linux Enterprise Server 15 SP2 Terminology Table 2. Terminology Terminology App-direct mode (AD) CLI PMem GiB GB iMC Interleave Set x1 (by applications...
EMC PMem 200 Series Users Guide
Page 8
...configurations in -flight data contents to meet these guidelines are recommended per processor socket. Four-socket configurations are present in R650, R750, R750xa, MX750c, XR11 and XR12 PowerEdge servers with more details on PMem configuration and provisioning concepts. The following image and table is supported in the system. For... pre-configured to persistent media. See PMem configurations for DIMM and miniDIMM Connectors documentation by JEDEC. All systems built from Dell Technologies factories will be followed while handling, installing, or removing PMem memories.
...configurations in -flight data contents to meet these guidelines are recommended per processor socket. Four-socket configurations are present in R650, R750, R750xa, MX750c, XR11 and XR12 PowerEdge servers with more details on PMem configuration and provisioning concepts. The following image and table is supported in the system. For... pre-configured to persistent media. See PMem configurations for DIMM and miniDIMM Connectors documentation by JEDEC. All systems built from Dell Technologies factories will be followed while handling, installing, or removing PMem memories.
EMC PMem 200 Series Users Guide
Page 10
..., 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 15, 16} Processor2 {B1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 15, 16} Processor1 {A5, 6} Processor2 {B5, 6} NOTE: There are limited configurations available for dual socket servers with only one processor populated. Table 4. Table 5.
..., 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 15, 16} Processor2 {B1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 15, 16} Processor1 {A5, 6} Processor2 {B5, 6} NOTE: There are limited configurations available for dual socket servers with only one processor populated. Table 4. Table 5.
EMC PMem 200 Series Users Guide
Page 21
...) ○ 7 = Critical (LC log and SEL) ● Y - Version ○ 1 = Initial messages ● ZZ - MEM5101 A diagnostic event occurred in Server System Event Log(SEL) and Life-Cycle Log(LCL). Reseat Info the device. (Debug Code: ). The term NVDIMM is generic to several different families of...Debug Code: ). MEM5102 A diagnostic event occurred in these messages. NOTE: NVDIMM is operating normally. (Debug Code: ). The Info server has automatically taken corrective action and the device is frequently used in the memory device at . PMem event reporting 21 Message ID and...
...) ○ 7 = Critical (LC log and SEL) ● Y - Version ○ 1 = Initial messages ● ZZ - MEM5101 A diagnostic event occurred in Server System Event Log(SEL) and Life-Cycle Log(LCL). Reseat Info the device. (Debug Code: ). The term NVDIMM is generic to several different families of...Debug Code: ). MEM5102 A diagnostic event occurred in these messages. NOTE: NVDIMM is operating normally. (Debug Code: ). The Info server has automatically taken corrective action and the device is frequently used in the memory device at . PMem event reporting 21 Message ID and...
EMC PMem 200 Series Users Guide
Page 23
...the nonvolatile DIMM with serial number in the Persistent Memory (PM) region may not be accessible. Recommended Action : Power off the server and replace the NVDIMM immediately. If the issue persists, contact your service provider. Recommended Action : For more information about NVDIMMs, see... the platform Installation and Service Manual available on the server and retry the operation. If the issue persists, replace the NVDIMM. Recommended Action : Power off the server and replace the NVDIMMs to the system, wait for 30 seconds, and reconnect ...
...the nonvolatile DIMM with serial number in the Persistent Memory (PM) region may not be accessible. Recommended Action : Power off the server and replace the NVDIMM immediately. If the issue persists, contact your service provider. Recommended Action : For more information about NVDIMMs, see... the platform Installation and Service Manual available on the server and retry the operation. If the issue persists, replace the NVDIMM. Recommended Action : Power off the server and replace the NVDIMMs to the system, wait for 30 seconds, and reconnect ...
EMC PMem 200 Series Users Guide
Page 24
... UEFI0377 : The Non-Volatile Dual In-Line memory module (NVDIMM) in slot requires a maintenance. Recommended Action : Turn off the server and replace the NVDIMM immediately. Recommended Action : Verify the NVDIMM population configuration and retry the operation. Recommended Action : N/A NOTE: ... Retry the operation. Recommended Action : Consider replacing the DIMM during the previous boot. Recommended Action : Power off the server and replace the NVDIMM immediately. For more information about installation and removal, see the product Installation and Service Manual available ...
... UEFI0377 : The Non-Volatile Dual In-Line memory module (NVDIMM) in slot requires a maintenance. Recommended Action : Turn off the server and replace the NVDIMM immediately. Recommended Action : Verify the NVDIMM population configuration and retry the operation. Recommended Action : N/A NOTE: ... Retry the operation. Recommended Action : Consider replacing the DIMM during the previous boot. Recommended Action : Power off the server and replace the NVDIMM immediately. For more information about installation and removal, see the product Installation and Service Manual available ...
EMC PMem 200 Series Users Guide
Page 25
... Manual of power loss. ● UEFI0378 : The Non-Volatile Dual In-Line memory module (NVDIMM) in the event of the system available on the server. PMem event reporting 25 Recommended Action : Do one of the following and retry the operation: ○ Turn off the... server. 2) Disconnect the input power, wait for 30 seconds, and then reconnect to the power source. 3) Power on the server. 4) If the issue persists, contact your service provider. ● PWR2281 : Unable to perform the memory...
... Manual of power loss. ● UEFI0378 : The Non-Volatile Dual In-Line memory module (NVDIMM) in the event of the system available on the server. PMem event reporting 25 Recommended Action : Do one of the following and retry the operation: ○ Turn off the... server. 2) Disconnect the input power, wait for 30 seconds, and then reconnect to the power source. 3) Power on the server. 4) If the issue persists, contact your service provider. ● PWR2281 : Unable to perform the memory...
EMC PMem 200 Series Users Guide
Page 29
... PMem sanitize Memory mode In Memory mode PMems operate as volatile system memory. If the PMems are moved from one server to another server, the user must be cleared by the Dell BIOS and operating system level security changes including Passphrase management and PMem erasing functions will not reprompt for slot replacement between...
... PMem sanitize Memory mode In Memory mode PMems operate as volatile system memory. If the PMems are moved from one server to another server, the user must be cleared by the Dell BIOS and operating system level security changes including Passphrase management and PMem erasing functions will not reprompt for slot replacement between...
EMC PMem 200 Series Users Guide
Page 33
... must be recreated once it is not supported, and not validated. If a Security Passphrase is enabled, the new persistent memory region is replaced. Once the server is recommended that customers back up prior creating a goal. PMems and data content will automatically restore the BIOS configuration on Intel PMem must be available...
... must be recreated once it is not supported, and not validated. If a Security Passphrase is enabled, the new persistent memory region is replaced. Once the server is recommended that customers back up prior creating a goal. PMems and data content will automatically restore the BIOS configuration on Intel PMem must be available...
EMC PMem 200 Series Users Guide
Page 37
.... Figure 21. PMem disk with interleave sets When Interleave set is enabled, BIOS assigns single Region Id for PMems connected to windows server. PMem Disk creation with the interleave set using Windows VDS (Virtual disk service). For information about storage spaces method refer to create ... devices be selected during goal configuration. Remove PMem disks Figure 20. In order to : https://docs.microsoft.com/en-us/windows-server/storage/storagespaces/deploy-standalone-storage-spaces. For PMem Disk with interleave sets In above example two Interleave sets have been created, one ...
.... Figure 21. PMem disk with interleave sets When Interleave set is enabled, BIOS assigns single Region Id for PMems connected to windows server. PMem Disk creation with the interleave set using Windows VDS (Virtual disk service). For information about storage spaces method refer to create ... devices be selected during goal configuration. Remove PMem disks Figure 20. In order to : https://docs.microsoft.com/en-us/windows-server/storage/storagespaces/deploy-standalone-storage-spaces. For PMem Disk with interleave sets In above example two Interleave sets have been created, one ...
EMC PMem 200 Series Users Guide
Page 39
Figure 24. Windows troubleshooting and event monitoring Windows Errata The following errata affects Windows OSes and are expected to be fixed in a future OS patch. ● When a namespace is considered as "The driver for WS2019. This means the namespace is created, and is created in Windows Server 2019 (WS2019), the logged message appears as WAD for persistent memory disk encounters internal error". The error is expected and it may occur during testing of Storage Class Memory (SCM) device. Workaround: None. Windows 39
Figure 24. Windows troubleshooting and event monitoring Windows Errata The following errata affects Windows OSes and are expected to be fixed in a future OS patch. ● When a namespace is considered as "The driver for WS2019. This means the namespace is created, and is created in Windows Server 2019 (WS2019), the logged message appears as WAD for persistent memory disk encounters internal error". The error is expected and it may occur during testing of Storage Class Memory (SCM) device. Workaround: None. Windows 39
EMC PMem 200 Series Users Guide
Page 45
... to view the PMem devices that are attached to register PMem file system for APD notifications. As a solution, perform sanitization operation before creating a new goal. Dell EMC does not support Non-interleaved App Direct goals with the critical error. The host...
... to view the PMem devices that are attached to register PMem file system for APD notifications. As a solution, perform sanitization operation before creating a new goal. Dell EMC does not support Non-interleaved App Direct goals with the critical error. The host...
EMC PMem 200 Series Users Guide
Page 47
...system will be updated using the Lifecycle Controller: a. Launch Lifecycle controller (LC) during boot. Launch Firmware Update from the Dell support site. Select FTP server or local drive that contains DUP bin file ii. a. If operating systems is up to Maintenance > System Update, upload... system and DUP will automatically reboot and flash the firmware using Lifecycle Controller see: Lifecycle Controller User's Guide available at https://www.dell.com/idracmanuals . NOTE: Make sure BIOS is not accessible, log in to the operating system and execute DUP package. Execute the...
...system will be updated using the Lifecycle Controller: a. Launch Lifecycle controller (LC) during boot. Launch Firmware Update from the Dell support site. Select FTP server or local drive that contains DUP bin file ii. a. If operating systems is up to Maintenance > System Update, upload... system and DUP will automatically reboot and flash the firmware using Lifecycle Controller see: Lifecycle Controller User's Guide available at https://www.dell.com/idracmanuals . NOTE: Make sure BIOS is not accessible, log in to the operating system and execute DUP package. Execute the...
EMC Technical Specifications
Page 7
... following operating systems: ● Canonical Ubuntu Server LTS ● Citrix Hypervisor ● Microsoft Windows Server with Hyper-V ● Red Hat Enterprise Linux ● SUSE Linux Enterprise Server ● VMware ESXi Cooling specifications Cooling options The PowerEdge R650 requires various cooling components based on certain CPU..., verify the system power consumption with one fan connector. The PowerEdge R650 offers two types of fan module includes two fan body with the Dell Energy Smart Solution Advisor available at Dell.com/ESSA. One set of fan modules are required and in...
... following operating systems: ● Canonical Ubuntu Server LTS ● Citrix Hypervisor ● Microsoft Windows Server with Hyper-V ● Red Hat Enterprise Linux ● SUSE Linux Enterprise Server ● VMware ESXi Cooling specifications Cooling options The PowerEdge R650 requires various cooling components based on certain CPU..., verify the system power consumption with one fan connector. The PowerEdge R650 offers two types of fan module includes two fan body with the Dell Energy Smart Solution Advisor available at Dell.com/ESSA. One set of fan modules are required and in...