User Manual
Page 8
... system. Frequency: Current consumption: 50 Hz/60 Hz (AC power supply unit) 12 A - 6.5 A (X 2) (with 1100 W AC power supply unit) 10 A - 5 A (X 2) (with 750 W AC power supply unit) 6.5 A - 3 A (X 2) (with 495 W AC power supply unit) 32 A (X 2) (with 1100 W DC power supply unit) Technical Specifications...a phase to support.dell.com. DC Power Supply (per power supply) Wattage 495 W, 750 W, or 1100 W Heat dissipation 1908 BTU/hr maximum (495 W power NOTE: Heat dissipation is calculated using the power supply wattage rating. Power AC Power Supply (per power supply) (when available)...
... system. Frequency: Current consumption: 50 Hz/60 Hz (AC power supply unit) 12 A - 6.5 A (X 2) (with 1100 W AC power supply unit) 10 A - 5 A (X 2) (with 750 W AC power supply unit) 6.5 A - 3 A (X 2) (with 495 W AC power supply unit) 32 A (X 2) (with 1100 W DC power supply unit) Technical Specifications...a phase to support.dell.com. DC Power Supply (per power supply) Wattage 495 W, 750 W, or 1100 W Heat dissipation 1908 BTU/hr maximum (495 W power NOTE: Heat dissipation is calculated using the power supply wattage rating. Power AC Power Supply (per power supply) (when available)...
Owner's Manual
Page 74
...-(48-60) V DC SELV source). Input Requirements • Supply voltage: -(48-60) V DC • Current consumption: 32 A (maximum) Kit Contents • Dell part number 6RYJ9 terminal block or equivalent (1) • #6-32 nut equipped with lock washer (1) Required Tools Wire-stripper pliers...yellow stripe, stranded wire (safety ground) Assembling And Connecting The Safety Ground Wire WARNING: For equipment using -(48-60) V DC power supplies, a qualified electrician must perform all safety instructions that is suitably approved and rated shall be incorporated in the field wiring. CAUTION:...
...-(48-60) V DC SELV source). Input Requirements • Supply voltage: -(48-60) V DC • Current consumption: 32 A (maximum) Kit Contents • Dell part number 6RYJ9 terminal block or equivalent (1) • #6-32 nut equipped with lock washer (1) Required Tools Wire-stripper pliers...yellow stripe, stranded wire (safety ground) Assembling And Connecting The Safety Ground Wire WARNING: For equipment using -(48-60) V DC power supplies, a qualified electrician must perform all safety instructions that is suitably approved and rated shall be incorporated in the field wiring. CAUTION:...
Owner's Manual
Page 127
... redundant. LCD Message An over current fault detected on power supply . PSU0076 Message A power supply wattage mismatch is rated for proper configuration. Action Install matched power supplies and review this manual for watts. Action Check input power. LCD Message PSU redundancy degraded. Review system configuration and power consumption. Details The system may be of an electrical...
... redundant. LCD Message An over current fault detected on power supply . PSU0076 Message A power supply wattage mismatch is rated for proper configuration. Action Install matched power supplies and review this manual for watts. Action Check input power. LCD Message PSU redundancy degraded. Review system configuration and power consumption. Details The system may be of an electrical...
Owner's Manual
Page 128
... SD Module is write protected. Review system configuration and power consumption and upgrade or install power supplies accordingly. Action If unintended, review system configuration changes and power policy. PWR1006 Message The system halted because system power exceeds capacity. Action Review system configuration, upgrade power supplies or reduce system power consumption. RFM1014 Message Removable Flash Media is offline. RFM1201...
... SD Module is write protected. Review system configuration and power consumption and upgrade or install power supplies accordingly. Action If unintended, review system configuration changes and power policy. PWR1006 Message The system halted because system power exceeds capacity. Action Review system configuration, upgrade power supplies or reduce system power consumption. RFM1014 Message Removable Flash Media is offline. RFM1201...