Information Update
Page 16
...parity error on a component that resides in the Hardware Owner's Manual. See "Getting Help" in the Hardware Owner's Manual. See the "RAID Battery" and see "Troubleshooting an Expansion Card" in PCI configuration space at bus ##, device ##, function ##. Check the AC power source. Remove and... reseat the PCIe expansion cards. LCD Status Messages (continued) Code E1211 Text ROMB Batt Causes RAID battery is faulty. Table 1-2. E1625 E1711 PS AC Current PCI PERR B## D## F## PCI PERR Slot # Power source is out of acceptable range...
...parity error on a component that resides in the Hardware Owner's Manual. See "Getting Help" in the Hardware Owner's Manual. See the "RAID Battery" and see "Troubleshooting an Expansion Card" in PCI configuration space at bus ##, device ##, function ##. Check the AC power source. Remove and... reseat the PCIe expansion cards. LCD Status Messages (continued) Code E1211 Text ROMB Batt Causes RAID battery is faulty. Table 1-2. E1625 E1711 PS AC Current PCI PERR B## D## F## PCI PERR Slot # Power source is out of acceptable range...
Hardware Owner's Manual (PDF)
Page 20
...Code Text N/A SYSTEM NAME E1000 E1114 FAILSAFE, Call Support Temp Ambient E1116 Temp Memory E12nn xx PwrGd E1210 CMOS Batt E1211 ROMB Batt E1229 CPU # VCORE E1310 RPM Fan ## E1313 Fan Redundancy Causes Corrective Actions A 62-character string that can change ... acceptable See "Troubleshooting System temperature and has been Cooling Problems" on page 119. Table 1-6. Cooling Problems" on page 119. CMOS battery is missing, or the See "Troubleshooting the System voltage is off and active POST errors are displayed. page 74, and "Troubleshooting ...
...Code Text N/A SYSTEM NAME E1000 E1114 FAILSAFE, Call Support Temp Ambient E1116 Temp Memory E12nn xx PwrGd E1210 CMOS Batt E1211 ROMB Batt E1229 CPU # VCORE E1310 RPM Fan ## E1313 Fan Redundancy Causes Corrective Actions A 62-character string that can change ... acceptable See "Troubleshooting System temperature and has been Cooling Problems" on page 119. Table 1-6. Cooling Problems" on page 119. CMOS battery is missing, or the See "Troubleshooting the System voltage is off and active POST errors are displayed. page 74, and "Troubleshooting ...
Hardware Owner's Manual (PDF)
Page 27
... sensors, such as temperature, voltage, fans, and so on page 169. For other faults, you might be able to a normal state. W1228 ROMB Batt < 24hr Warns predictively that is a failing power supply. In contrast, you know that a microprocessor is not installed in this task remotely, ...you receive a series of range, the LCD displays the fault; You can often specify a very precise fault condition that the RAID Replace RAID battery. Turn off the system and disconnect it from the LCD. wait approximately ten seconds, reconnect the power cable, and restart the system. About...
... sensors, such as temperature, voltage, fans, and so on page 169. For other faults, you might be able to a normal state. W1228 ROMB Batt < 24hr Warns predictively that is a failing power supply. In contrast, you know that a microprocessor is not installed in this task remotely, ...you receive a series of range, the LCD displays the fault; You can often specify a very precise fault condition that the RAID Replace RAID battery. Turn off the system and disconnect it from the LCD. wait approximately ten seconds, reconnect the power cable, and restart the system. About...