User's Guide (.htm)
Page 21
... two Copper ports which can function either as stand-alone, multi-layer, switching devices or stackable devices with minimal management. The PowerConnect 3424P also provides Power over Ethernet (PoE). PowerConnect 3424 and PowerConnect 3424P Introduction 21 This User Guide contains the information needed for installing, configuring, and maintaining the device. The device also provides one...
... two Copper ports which can function either as stand-alone, multi-layer, switching devices or stackable devices with minimal management. The PowerConnect 3424P also provides Power over Ethernet (PoE). PowerConnect 3424 and PowerConnect 3424P Introduction 21 This User Guide contains the information needed for installing, configuring, and maintaining the device. The device also provides one...
User's Guide (.htm)
Page 22
...dell.com | support.dell.com PowerConnect 3448 The PowerConnect 3448 provides 48 10/100Mbps ports plus two SFP ports, and two Copper ports which the stack is managed from a: • Web-based interface • SNMP Management Station • Command Line Interface (CLI) PowerConnect 3424/P and PowerConnect... 3448/P devices support stacking up to six units per stack, or can operate as stand-alone units. Figure 1-2. The PowerConnect 3448 is stacked. In addition, PowerConnect 3448P provides PoE. The stack is managed. The...
...dell.com | support.dell.com PowerConnect 3448 The PowerConnect 3448 provides 48 10/100Mbps ports plus two SFP ports, and two Copper ports which the stack is managed from a: • Web-based interface • SNMP Management Station • Command Line Interface (CLI) PowerConnect 3424/P and PowerConnect... 3448/P devices support stacking up to six units per stack, or can operate as stand-alone units. Figure 1-2. The PowerConnect 3448 is stacked. In addition, PowerConnect 3448P provides PoE. The stack is managed. The...
User's Guide (.htm)
Page 28
... open cables and cable shorts. Flow Control Support (IEEE 802.3X) Flow control enables lower speed devices to power sources. PoE removes the need for placing network devices next to communicate with higher speed devices, by traffic competing for ports or LAGs, see... all updated device features, see "Managing Power over Ethernet (PoE) provides power to prevent buffer overflows. For more information about Power over Ethernet, see the latest software version Release Notes. www.dell.com | support.dell.com Features Overview This section describes the device features. Power...
... open cables and cable shorts. Flow Control Support (IEEE 802.3X) Flow control enables lower speed devices to power sources. PoE removes the need for placing network devices next to communicate with higher speed devices, by traffic competing for ports or LAGs, see... all updated device features, see "Managing Power over Ethernet (PoE) provides power to prevent buffer overflows. For more information about Power over Ethernet, see the latest software version Release Notes. www.dell.com | support.dell.com Features Overview This section describes the device features. Power...
User's Guide (.htm)
Page 40
www.dell.com | support.dell.com Physical Dimensions The PowerConnect 3424/P and PowerConnect 3448/P devices have the following figure illustrates the 10/100 Base-T port LEDs on The PowerConnect 3424 /P and PowerConnect 3448/P switches: Figure 2-6. RJ-45 Copper Based 10/100 BaseT LEDs Speed/LNK/ACT FDX Speed/LNK/ACT FDX The RJ-45 100 ... Base-T port and 10/100 Base-T port has two LEDs. The speed LED is located on the right side. The following physical dimensions: PoE Model: • Width - 440 mm (17.32 inch) • Depth - 387 mm (15.236 inch) • Height - 43.2 mm (1.7 inch)...
www.dell.com | support.dell.com Physical Dimensions The PowerConnect 3424/P and PowerConnect 3448/P devices have the following figure illustrates the 10/100 Base-T port LEDs on The PowerConnect 3424 /P and PowerConnect 3448/P switches: Figure 2-6. RJ-45 Copper Based 10/100 BaseT LEDs Speed/LNK/ACT FDX Speed/LNK/ACT FDX The RJ-45 100 ... Base-T port and 10/100 Base-T port has two LEDs. The speed LED is located on the right side. The following physical dimensions: PoE Model: • Width - 440 mm (17.32 inch) • Depth - 387 mm (15.236 inch) • Height - 43.2 mm (1.7 inch)...
User's Guide (.htm)
Page 45
... AC power supply unit operates from 90 to 264 VAC, 47 to a PowerConnect RPS-600 unit. Table 2-6. Power supply LEDs indicate the status of 370W for 24 ports PoE device. The following figure illustrates the LEDs on the front panel and indicates whether... an internal power supply unit (AC unit) and a connector to connect PowerConnect 3424/P and PowerConnect 3448/P devices to a PowerConnect EPS-470 unit, or to connect PowerConnect 3424 and PowerConnect 3448 devices to 63 Hz. The PowerConnect 3424/P and PowerConnect 3448/P devices have an internal power supply of 470W (12V/-48V), with...
... AC power supply unit operates from 90 to 264 VAC, 47 to a PowerConnect RPS-600 unit. Table 2-6. Power supply LEDs indicate the status of 370W for 24 ports PoE device. The following figure illustrates the LEDs on the front panel and indicates whether... an internal power supply unit (AC unit) and a connector to connect PowerConnect 3424/P and PowerConnect 3448/P devices to a PowerConnect EPS-470 unit, or to connect PowerConnect 3424 and PowerConnect 3448 devices to 63 Hz. The PowerConnect 3424/P and PowerConnect 3448/P devices have an internal power supply of 470W (12V/-48V), with...
User's Guide (.htm)
Page 47
For example, if there are four units in fans. The non-PoE PowerConnect 3424 and PowerConnect 3448 devices have five built-in a stack, the Master unit is either 1 or 2, the backup Master is either 1 or 2 depending on the front panel, for ... Unit ID of the switch is activated by observing the LED that is reset. If only a member unit is 4. Ventilation System The PowerConnect 3424/P and PowerConnect 3448/P switches with the PoE feature have two built-in stand-alone mode. Operation can be selected within 15 seconds, the device is not selected within 15 seconds...
For example, if there are four units in fans. The non-PoE PowerConnect 3424 and PowerConnect 3448 devices have five built-in a stack, the Master unit is either 1 or 2, the backup Master is either 1 or 2 depending on the front panel, for ... Unit ID of the switch is activated by observing the LED that is reset. If only a member unit is 4. Ventilation System The PowerConnect 3424/P and PowerConnect 3448/P switches with the PoE feature have two built-in stand-alone mode. Operation can be selected within 15 seconds, the device is not selected within 15 seconds...
User's Guide (.htm)
Page 49
...rubber pads • Rack-mount kit for cabling, power connections, and ventilation. • Cabling - Installing the PowerConnect 3424/P and PowerConnect 3448/P Site Preparation The PowerConnect 3424 /P and PowerConnect 3448/P devices can be mounted in a standard 48.26-am (19-inch) equipment rack, placed on a ...tabletop or mounted on the front panel are illuminated. • PoE Models - There is correctly installed by checking that the...
...rubber pads • Rack-mount kit for cabling, power connections, and ventilation. • Cabling - Installing the PowerConnect 3424/P and PowerConnect 3448/P Site Preparation The PowerConnect 3424 /P and PowerConnect 3448/P devices can be mounted in a standard 48.26-am (19-inch) equipment rack, placed on a ...tabletop or mounted on the front panel are illuminated. • PoE Models - There is correctly installed by checking that the...
User's Guide (.htm)
Page 99
... have two fans, while the PoE devices have five fans. The possible field values are : - The fan is displayed as RPS. Temperature - The temperature at which the device asset information is ...
... have two fans, while the PoE devices have five fans. The possible field values are : - The fan is displayed as RPS. Temperature - The temperature at which the device asset information is ...
User's Guide (.htm)
Page 101
... Unit Fan ---- --- 1 CPU 2 CPU Status -----OK OK Managing Power over Ethernet Power over Ethernet (PoE) provides power to power sources. Powered devices are connected to the PowerConnect device via either all PowerConnect 3424P's 24 FE ports or all PowerConnect 3448P's 48 FE ports. Powered Devices are connected via Ethernet ports. To open the Power... removes the necessity of placing network devices next to devices over Ethernet in the tree view. Powered Devices are devices which receive power from the PowerConnect power supplies, for example IP phones.
... Unit Fan ---- --- 1 CPU 2 CPU Status -----OK OK Managing Power over Ethernet Power over Ethernet (PoE) provides power to power sources. Powered devices are connected to the PowerConnect device via either all PowerConnect 3424P's 24 FE ports or all PowerConnect 3448P's 48 FE ports. Powered Devices are connected via Ethernet ports. To open the Power... removes the necessity of placing network devices next to devices over Ethernet in the tree view. Powered Devices are devices which receive power from the PowerConnect power supplies, for example IP phones.
User's Guide (.htm)
Page 102
... Power - Indicates the percentage of power consumed before an alarm is functioning, but an error has occurred. Traps - Enables or Disables receiving PoE device traps. www.dell.com | support.dell.com Figure 6-5. Indicates that the power supply unit is generated. Nominal Power - The field value is functioning. The field value is displayed in...
... Power - Indicates the percentage of power consumed before an alarm is functioning, but an error has occurred. Traps - Enables or Disables receiving PoE device traps. www.dell.com | support.dell.com Figure 6-5. Indicates that the power supply unit is generated. Nominal Power - The field value is functioning. The field value is displayed in...
User's Guide (.htm)
Page 103
...to 12.95 Watts. 0.44 - 3.8 - The possible field values are : 0.44 - 12.95 - PoE Operational Status - Testing - Indicates that the PowerConnect device has detected a fault on PoE. Searching is low. Indicates the amount of .44 to the selected interface. The field values are classified by...to work on the powered device. Indicates if the port is currently searching for which PoE parameters are : On - For example, a port could not be denied power. Indicates that the PowerConnect device is enabled to 3.8 Watts. Determines the port priority if the power supply is...
...to 12.95 Watts. 0.44 - 3.8 - The possible field values are : 0.44 - 12.95 - PoE Operational Status - Testing - Indicates that the PowerConnect device has detected a fault on PoE. Searching is low. Indicates the amount of .44 to the selected interface. The field values are classified by...to work on the powered device. Indicates if the port is currently searching for which PoE parameters are : On - For example, a port could not be denied power. Indicates that the PowerConnect device is enabled to 3.8 Watts. Determines the port priority if the power supply is...
User's Guide (.htm)
Page 104
... Indicates times the powered device was no longer detected. Invalid Signature Counter - Indicate the times an invalid signature was received. www.dell.com | support.dell.com 3.84 - 6.49 - Short Counter - Signatures are the means by which the powered device identifies itself to the powered ...device because the powered device was denied power. Configures the priority of the interface from the point of view of the powered device type. Defining PoE ...
... Indicates times the powered device was no longer detected. Invalid Signature Counter - Indicate the times an invalid signature was received. www.dell.com | support.dell.com 3.84 - 6.49 - Short Counter - Signatures are the means by which the powered device identifies itself to the powered ...device because the powered device was denied power. Configures the priority of the interface from the point of view of the powered device type. Defining PoE ...
User's Guide (.htm)
Page 105
...Low On 0.44 - 3.84 3/e1 Auto Low Off N/A Console# show power inline Displays PoE configuration information [ethernet interface ] The following is an example of the PoE CLI commands. Table 6-16. System Health CLI Commands (continued) CLI Command Description power inline ...Configures the threshold for triggering alarms usage-threshold power inline traps enable Enables PoE device traps show power inline ethernet 1/e1 Port Powered Device State Priority Status Classification [W] 1/1e IP Phone Model A Auto ...
...Low On 0.44 - 3.84 3/e1 Auto Low Off N/A Console# show power inline Displays PoE configuration information [ethernet interface ] The following is an example of the PoE CLI commands. Table 6-16. System Health CLI Commands (continued) CLI Command Description power inline ...Configures the threshold for triggering alarms usage-threshold power inline traps enable Enables PoE device traps show power inline ethernet 1/e1 Port Powered Device State Priority Status Classification [W] 1/1e IP Phone Model A Auto ...
User's Guide (.htm)
Page 401
..., 29, 249, 394 MDI/MDIX, 76 MDIX, 29, 249, 394 MDU, 394 Message, 111 Message digest 5, 111, 394 MIB, 189, 394 Multicast, 331 PING, 395 PoE, 21, 28, 101 Port, 39 Port LEDs, 40 Port mirroring, 260 Ports, 81, 246, 368 Power over Ethernet, 21, 28, 101 Power supplies, 45, 98...