LiDE80_spec.pdf
Page 1
... change without condensation) Operating humidity: 10% to 90% RH Warranty◊◊ 1-year limited warranty with InstantExchange program Ordering Information Scanner CanoScan LiDE 80 Color Image Scanner 7877A002 CanoScan LiDE 80 Color Image Scanner For More Information Visit www.usa.canon.com/consumer www.canoscan.com For the name of Apple Computer, Inc., registered in the U.S. PageManager® (Windows) Power Requirements Powered through USB port...
... change without condensation) Operating humidity: 10% to 90% RH Warranty◊◊ 1-year limited warranty with InstantExchange program Ordering Information Scanner CanoScan LiDE 80 Color Image Scanner 7877A002 CanoScan LiDE 80 Color Image Scanner For More Information Visit www.usa.canon.com/consumer www.canoscan.com For the name of Apple Computer, Inc., registered in the U.S. PageManager® (Windows) Power Requirements Powered through USB port...
CanoScan LiDE80 Quick Start Guide
Page 2
... use this guide, Windows XP screen shots are trademarks of ScanSoft, Inc. • Other names and products not mentioned above may cause undesired operation. Canon U.S.A. Color Image Scanner Models F917000: (CanoScan LiDE 80) This device complies with the technical requirements of the EMC Directive. If such changes or modifications should consult your legal adviser in advance. •...
... use this guide, Windows XP screen shots are trademarks of ScanSoft, Inc. • Other names and products not mentioned above may cause undesired operation. Canon U.S.A. Color Image Scanner Models F917000: (CanoScan LiDE 80) This device complies with the technical requirements of the EMC Directive. If such changes or modifications should consult your legal adviser in advance. •...
CanoScan LiDE80 Quick Start Guide
Page 10
... Acquire icon or click the [File] menu and select [Acquire]. The image is automatically cropped at its original size. If an error message appears, click the [File] menu, choose [Select Source], select your scanner model name and click the [Select] button. ScanGear CS will start .... When the [Select Source] dialog displays, select [ScanGear CS 7.2] and click the [OK] button. You can select "Photo", "Magazine", "Newspaper" or "Document". •Photo: Color, 300 dpi •Magazine: Color, 150 dpi...
... Acquire icon or click the [File] menu and select [Acquire]. The image is automatically cropped at its original size. If an error message appears, click the [File] menu, choose [Select Source], select your scanner model name and click the [Select] button. ScanGear CS will start .... When the [Select Source] dialog displays, select [ScanGear CS 7.2] and click the [OK] button. You can select "Photo", "Magazine", "Newspaper" or "Document". •Photo: Color, 300 dpi •Magazine: Color, 150 dpi...
CanoScan LiDE80 Quick Start Guide
Page 13
Scanning Film Scanning Film This scanner can affect image quality or damage the film. • You cannot scan film with the... Unit over the slots at a time. Calibration is required the first time the scanner is aligned with the correct coloration. This procedure adjusts the scanner output so that its alignment tab is used to scan film. Preparing to Scan ... film. • Clean the document glass before setting the Film Adapter Unit on the document glass of the scanner. It is explained below using the example of ArcSoft PhotoStudio and ScanGear CS in the upright position. 1 Attach...
Scanning Film Scanning Film This scanner can affect image quality or damage the film. • You cannot scan film with the... Unit over the slots at a time. Calibration is required the first time the scanner is aligned with the correct coloration. This procedure adjusts the scanner output so that its alignment tab is used to scan film. Preparing to Scan ... film. • Clean the document glass before setting the Film Adapter Unit on the document glass of the scanner. It is explained below using the example of ArcSoft PhotoStudio and ScanGear CS in the upright position. 1 Attach...
CanoScan LiDE80 Quick Start Guide
Page 16
...the [Select Source] dialog displays, select [ScanGear CS 7.2] and click the [OK] button. You can also select a frame number. The scanned image will start . 10 Click or (close it. Click the Acquire icon or click the [File] menu and select [Import...]. ScanGear CS's Simple...Color Positive Film]. • Use the Advanced Mode to scan monochrome film (See the Scanning Guide). 7 Confirm that film is in the PhotoStudio window. 14 Click the Acquire icon or click the [File] menu and select [Acquire]. If an error message appears, click the [File] menu, choose [Select Source], select your scanner...
...the [Select Source] dialog displays, select [ScanGear CS 7.2] and click the [OK] button. You can also select a frame number. The scanned image will start . 10 Click or (close it. Click the Acquire icon or click the [File] menu and select [Import...]. ScanGear CS's Simple...Color Positive Film]. • Use the Advanced Mode to scan monochrome film (See the Scanning Guide). 7 Confirm that film is in the PhotoStudio window. 14 Click the Acquire icon or click the [File] menu and select [Acquire]. If an error message appears, click the [File] menu, choose [Select Source], select your scanner...
CanoScan LiDE80 Quick Start Guide
Page 18
... notice. • Before you upgrade to the steps on page 3. Specifications Specifications CanoScan LiDE 80 Scanner Type Flatbed Scanning Element CIS (Color Contact Image Sensor) Light Source 3-color (RGB) LED Optical Resolution 2400 x 4800 dpi Selectable Resolution 25 - 9600 dpi (ScanGear CS) Scanning Bit Depth Color Grayscale 16 bit input / 16 bit or 8 bit output for film scanning...
... notice. • Before you upgrade to the steps on page 3. Specifications Specifications CanoScan LiDE 80 Scanner Type Flatbed Scanning Element CIS (Color Contact Image Sensor) Light Source 3-color (RGB) LED Optical Resolution 2400 x 4800 dpi Selectable Resolution 25 - 9600 dpi (ScanGear CS) Scanning Bit Depth Color Grayscale 16 bit input / 16 bit or 8 bit output for film scanning...