Question posted by bobzouf on October 5th, 2016

Enable Management Port On Ibm System X3650 7979

hi everybody i would know how enable a management port on IBM System x3650 type 7979.i confirgure a BMC with a good address IP, mask and gateway but when i connect a cable to management port, i not get a reponse. LED of management port are not turn on. i would use ipmitool for collect information of hardware best regard

Current Answers

Answer #1: Posted by techyagent on October 6th, 2016 1:21 AM
This answer was accepted by the poster of the original question.
techyagent

Member since:
June 17th, 2014

Points: 4,799,800
1,100
points
Systems-management Ethernet connector: Use this connector to connect the server to a network for systems-management information control. This connector is active only if you have installed a Remote Supervisor Adapter II SlimLine, and it is used only by the Remote Supervisor Adapter II SlimLine.

You can know more about this from here

Thanks


Techygirl

Related IBM 7979B1U Manual Pages

User Manual - Page 6

...é à la réglementation d'Industrie Canada 120 Australia and New Zealand Class A statement 120 United Kingdom telecommunications safety requirement 120 iv System x3650 Type 7979: User's Guide Configuring the server 85 Using the Configuration/Setup Utility program 86 Starting the Configuration/Setup Utility program 86 Configuration/Setup Utility menu choices 86 Passwords 90...
User Manual - Page 17

... be used to -date information about the terms of the six 3.5-inch drive bays. The server comes with a limited warranty. For information about the server and other IBM server products at http://www.ibm.com/systems/x/. 1. The System x3650 Type 7979 server The IBM® System x3650 Type 7979 server is ideally suited for the future. Install only 2.5-inch hard disk drives and an...
User Manual - Page 18

... setting up the server and basic instructions for updating, managing, and deploying firmware...server, including how to install supported optional devices and how to provide additional information that comes with the dc power supplies. Under Popular links, click Publications lookup. 2 System x3650 Type 7979: User's Guide In a dc power environment, only trained service personnel other than IBM...
User Manual - Page 19

...numbered for reference to you . The System x3650 Type 7979 server 3 Notices and statements in this document The...and type of optional features that are installed and the power-management optional...server. The sound levels were measured in controlled acoustical environments according to you . From the Product family menu, select System x3650 and click Continue. A danger statement is on the IBM...
User Manual - Page 20

... combination Expansion bays: v Hot-swap hard disk drive bays: SAS only. maximum altitude: 2133 m (7000 ft) v Humidity: - Server on : 10° to 35°C (50.0° to 109.4°F); Maximum: 1.00 kVA 4 System x3650 Type 7979: User's Guide Maximum: 127 V ac v Input voltage high range: - Features and specifications Microprocessor: v Intel® Xeon™ FC...
User Manual - Page 21

... provides programs to help you diagnose the problem. The System x3650 Type 7979 server 5 What your Intel-processor-based server powerful, scalable, and reliable. If an environmental condition exceeds a threshold or if a system component fails, the baseboard management controller lights LEDs to help you set up the server and install a Windows® operating system. Large system-memory...
User Manual - Page 22

...profile PCI Express x4 adapters. If a problem occurs with the primary Ethernet connection, all Ethernet traffic that measures and reports server power consumption as x4 adapters. Redundant cooling enables continued operation if one of independent disks (RAID) configurations. 6 System x3650 Type 7979: User's Guide The dc power supplies provide redundancy but the adapters will operate...
User Manual - Page 23

... to temporarily turn off the system-error LED v Remote system problem-determination support v Standby voltage for information about enabling TOE. The System x3650 Type 7979 server 7 v TCP/IP offload engine (TOE) support The Ethernet controllers in monitoring for fan, power, temperature, voltage, and power-supply redundancy v Cable-presence detection on most connectors v Chipkill memory...
User Manual - Page 24

..., and Novell NetWare. It is in Portable Document Format (PDF) at http://www.ibm.com/ servers/eserver/xseries/systems_management/, which presents an overview of IBM Systems Management and IBM Director. 8 System x3650 Type 7979: User's Guide IBM Director also provides an extensible platform that supports advanced server tools that are designed to 8 weeks. v Startup (boot) from LAN through...
User Manual - Page 27

... power supply. See the documentation that comes with the dc power supply for systems-management information control. The System x3650 Type 7979 server 11 During typical operation, both the ac and dc power LEDs are lit. Rack release latches: Press these LEDs are authorized to connect or disconnect power to this connector. Rear view CD/DVD drive activity...
User Manual - Page 28

...and is unavailable to the 12 System x3650 Type 7979: User's Guide Video connector: Connect a monitor to this connector. Serial connector: Connect a 9-pin serial device to this connector. Turning on the server Approximately 5 seconds after the server is connected to power. The power-on LED flashes to indicate that there is connected to power, the power-control button becomes...
User Manual - Page 44

... power supply. 28 System x3650 Type 7979: User's Guide Start the server, and make sure that the server is otherwise working correctly, see the System x and xSeries Tools Center at maximum levels of the object equally between your leg muscles. Place removed covers and other than IBM service technicians are addressed and that your server, complete the following...
User Manual - Page 104

..., press Enter to view the details of ROM code per PCI slot (see message 1801 in the server. Follow the instructions on the IBM System x Documentation CD). - Static IP Settings Define the static IP address, subnet mask, and gateway address for all microprocessors in the Problem Determination and Service Guide on the screen to the slot. - Virtualization Technology...
User Manual - Page 106

..., when you turn on the server, the system startup will not be used by typing the power-on password is intended...Utility menu. Passwords Determination and Service Guide on the IBM System x Documentation CD for instructions for running the diagnostic...on password, you can enable the Unattended Start mode, in the settings. You can type either password to cancel ...x3650 Type 7979: User's Guide
User Manual - Page 112

.... When you can run ServeRAID Manager as RAID-1. 7. (Optional) Type an identifier for the array build method, select Quick Init. 9. then, select Done to configure the SAS and RAID controllers and perform an initial RAID 96 System x3650 Type 7979: User's Guide Configuring the controller To configure a RAID array on the server. 2. To exit from a hard...
User Manual - Page 114

... management controller The baseboard management controller provides basic service-processor environmental monitoring functions for SOL by using the OSA SMBridge management utility program To enable and configure the server for the server. 8. Exit from ServeRAID Manager and remove the CD from http://www.ibm.com/ systems/support/ 98 System x3650 Type 7979: User's Guide Restart the server...
User Manual - Page 122

... modification. 106 System x3650 Type 7979: User's Guide b. then, press...enable SOL. Verify that the EMS console is based on one line. Type bootcfg at a Windows command prompt, type bootcfg /EMS ON /PORT COM1 /BAUD 19200 /ID boot_id where boot_id is the boot entry ID from step 1b; In your server...a line break. To enable the Microsoft Windows Emergency Management System (EMS), at ...
User Manual - Page 124

... to perform these procedures. 1. Type mount/mnt/cdrom. 4. To accept connections from any server, type INADDR_ANY as a root user to limit the connection requests that the utility program will be logged in the smbridge.cfg file for a TCP/IP port number and an IP address. Download the utility program and create the OSA BMC Management Utility CD. 2. Type the following steps. When...
User Manual - Page 126

... system-locator LED on and off remotely. - sysinfo Display system information that is related to the server and the baseboard management controller. Type connect -ip ip_address -u username -p password. - For device drivers and information about configuring the Ethernet controllers, see the 110 System x3650 Type 7979: User's Guide If the Ethernet ports in the server support auto-negotiation...
User Manual - Page 140

...x3650 Type 7979: User's Guide J jumper, clear CMOS (password override) 91 jumpers 21 L LEDs 11 Ethernet activity 11 Ethernet-link status 11 front of server 9 rear of server 11 riser-card assembly 24 system board 23 light path diagnostics about 6 location LED 12 locator LED 10 M management... panel 9 OSA SMBridge management utility program enabling and configuring 98 installing 107 P password administrator ...

Similar Questions

Ibm X3650 7979 Power Control Button On Operator Information Panel
My ibm server x3650 7979 has stopped powering on due to a problem with the power control button on t...
(Posted by abhijeet25036 10 years ago)
Part Number
I need the part number for the 2.5 inch drive tray for a X3650 7979-BEU
(Posted by tj703 11 years ago)
Is Tihs Server Is 64 Bits?
(Posted by Anonymous-46906 12 years ago)
Ask a New Question
Use the box below to post a new question about this IBM product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

IBM Manuals

Find free IBM 7979B1U manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

IBM Reviews

View thousands of IBM user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete IBM customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed IBM customer service rankings, employee comments and much more from our sister site.

IBM Recalls

Find comprehensive IBM recall information updated hourly on RecallOwl.com.