User Guide
Page 4
... your experiences as well. More help is a collection of answers to use ZyXEL products and share your product, the answer may be solved by the methods listed above, you received your device. 4 GS2200-8/24 User's Guide Customer Support Should problems arise that you should contact your...which you have the following information ready when you contact an office. • Product model and serial number. • Warranty Information. • Date that cannot be here. See http://www.zyxel.com/web/contact_us.php for the latest product updates and documentation from others who use...
... your experiences as well. More help is a collection of answers to use ZyXEL products and share your product, the answer may be solved by the methods listed above, you received your device. 4 GS2200-8/24 User's Guide Customer Support Should problems arise that you should contact your...which you have the following information ready when you contact an office. • Product model and serial number. • Warranty Information. • Date that cannot be here. See http://www.zyxel.com/web/contact_us.php for the latest product updates and documentation from others who use...
User Guide
Page 23
...layer-3, and layer-4 features suitable for a group of heavy traffic users. Consumption Rack mounting Wall mounting SWITCH MODEL GS2200-24P GS2200-8HP GS2200-24P GS-2200-8HP, GS2200-24P GS2200-8, GS2200-8HP, GS2200-24, GS2200-24P GS2200-8 This section shows a few examples of up to the Switch. The Switch is easy. In addition, ...the main features and applications of up to 15.4W per Ethernet port. The GS2200-8HP supports the IEEE 802.3at High Power over Ethernet (PoE) Power management mode - Table 1 Model-Specific Features FEATURE IEEE 802.3af PoE IEEE 802.3at High Power over Ethernet...
...layer-3, and layer-4 features suitable for a group of heavy traffic users. Consumption Rack mounting Wall mounting SWITCH MODEL GS2200-24P GS2200-8HP GS2200-24P GS-2200-8HP, GS2200-24P GS2200-8, GS2200-8HP, GS2200-24, GS2200-24P GS2200-8 This section shows a few examples of up to the Switch. The Switch is easy. In addition, ...the main features and applications of up to 15.4W per Ethernet port. The GS2200-8HP supports the IEEE 802.3at High Power over Ethernet (PoE) Power management mode - Table 1 Model-Specific Features FEATURE IEEE 802.3af PoE IEEE 802.3at High Power over Ethernet...
User Guide
Page 40
... The Status screen is the first screen that stays the same even if the Switch's power is the configuration of the web configurator. 40 GS2200-8/24 User's Guide Click the menu items to open the screen in . C - The following figure shows the navigating components of the Switch... tasks no matter which screen you are quick links which allow you access the web configurator. Nonvolatile memory is turned off. This guide uses the GS2200-24P screens as an example. B - B, C, D, E - Click this link to the status page of a web configurator screen. Figure 19 Web ...
... The Status screen is the first screen that stays the same even if the Switch's power is the configuration of the web configurator. 40 GS2200-8/24 User's Guide Click the menu items to open the screen in . C - The following figure shows the navigating components of the Switch... tasks no matter which screen you are quick links which allow you access the web configurator. Nonvolatile memory is turned off. This guide uses the GS2200-24P screens as an example. B - B, C, D, E - Click this link to the status page of a web configurator screen. Figure 19 Web ...
User Guide
Page 65
... 511 octets in length. This field shows the number of packets (including bad packets) received that were between 1519 octets and the maximum frame size. GS2200-8/24 User's Guide 65 The maximum frame size varies depending on page 307. Chapter 7 System Status and Port Statistics Table 8 Status: Port Details (continued) LABEL... field shows the number of packets (including bad packets) received that were between 1024 and 1518 octets in length. See Chapter 43 on your switch model.
... 511 octets in length. This field shows the number of packets (including bad packets) received that were between 1519 octets and the maximum frame size. GS2200-8/24 User's Guide 65 The maximum frame size varies depending on page 307. Chapter 7 System Status and Port Statistics Table 8 Status: Port Details (continued) LABEL... field shows the number of packets (including bad packets) received that were between 1024 and 1518 octets in length. See Chapter 43 on your switch model.
User Guide
Page 67
...the Switch. Status This field displays Normal for temperatures below the threshold and Error for those above the threshold. Product Model This field displays the product model of detecting and reporting if the temperature rises above . Current This shows the current temperature at this sensor. You...address of the Switch for other support information in this field. Temperature BOARD, MAC and PHY refer to display the screen as shown. GS2200-8/24 User's Guide 67 You may choose the temperature unit (Centigrade or Fahrenheit) in this screen. Figure 41 Basic Setting > System ...
...the Switch. Status This field displays Normal for temperatures below the threshold and Error for those above the threshold. Product Model This field displays the product model of detecting and reporting if the temperature rises above . Current This shows the current temperature at this sensor. You...address of the Switch for other support information in this field. Temperature BOARD, MAC and PHY refer to display the screen as shown. GS2200-8/24 User's Guide 67 You may choose the temperature unit (Centigrade or Fahrenheit) in this screen. Figure 41 Basic Setting > System ...
User Guide
Page 76
... the sending port, causing it to negotiate with higher priority. See Priority Queue Assignment in Table 11 on page 71 for the GS2200-8HP or GS2200-24P model only. Flow Control Selecting Auto (auto-negotiation) allows one port to temporarily stop sending signals and resend later. This field is ...panel to save your changes to the non-volatile memory when you can set the Switch to assign the remaining power to 24). 76 GS2200-8/24 User's Guide Flow Control is turned off , a port uses the pre-configured speed and duplex mode when making a connection, ...
... the sending port, causing it to negotiate with higher priority. See Priority Queue Assignment in Table 11 on page 71 for the GS2200-8HP or GS2200-24P model only. Flow Control Selecting Auto (auto-negotiation) allows one port to temporarily stop sending signals and resend later. This field is ...panel to save your changes to the non-volatile memory when you can set the Switch to assign the remaining power to 24). 76 GS2200-8/24 User's Guide Flow Control is turned off , a port uses the pre-configured speed and duplex mode when making a connection, ...
User Guide
Page 80
Port PD • Classification - This is only available on the PWR model but not available for the Gigabit or mini-GBIC ports. The following table describes the labels in the Basic Setting > PoE Status screen. Select this ... on the port. Select Low to set the Switch to assign the remaining power to the port after all critical priority ports are served. 80 GS2200-8/24 User's Guide This field is the port index number. Select this if you want the Switch to manage the total power supply so that...
Port PD • Classification - This is only available on the PWR model but not available for the Gigabit or mini-GBIC ports. The following table describes the labels in the Basic Setting > PoE Status screen. Select this ... on the port. Select Low to set the Switch to assign the remaining power to the port after all critical priority ports are served. 80 GS2200-8/24 User's Guide This field is the port index number. Select this if you want the Switch to manage the total power supply so that...
User Guide
Page 240
... CHAPTER 31 Differentiated Services 31.1 Overview This chapter shows you configure the screens in this chapter. All packets in the IP header. GS2200-8/24 User's Guide 240 In addition, applications do not have to request a particular service or give different priorities to give advanced notice... of where the traffic is backward compatible with DiffServ Code Points (DSCPs) indicating the level of service (CoS) model that marks packets so that they receive specific per-hop treatment at DiffServ-compliant network devices along the route based on the ...
... CHAPTER 31 Differentiated Services 31.1 Overview This chapter shows you configure the screens in this chapter. All packets in the IP header. GS2200-8/24 User's Guide 240 In addition, applications do not have to request a particular service or give different priorities to give advanced notice... of where the traffic is backward compatible with DiffServ Code Points (DSCPs) indicating the level of service (CoS) model that marks packets so that they receive specific per-hop treatment at DiffServ-compliant network devices along the route based on the ...
User Guide
Page 257
... displays. Click Management > Maintenance > Firmware Upgrade to view the screen as uploading the wrong model firmware may damage your computer before uploading to the device. This takes up to restart. GS2200-8/24 User's Guide 257 After the firmware upgrade process is complete, see the System Info screen... Type the path and file name of the firmware file you have downloaded (and unzipped) the correct model firmware and version to your device. Be sure to upload the correct model firmware as shown next. It also allows you reboot. Make sure you wish to upload to the...
... displays. Click Management > Maintenance > Firmware Upgrade to view the screen as uploading the wrong model firmware may damage your computer before uploading to the device. This takes up to restart. GS2200-8/24 User's Guide 257 After the firmware upgrade process is complete, see the System Info screen... Type the path and file name of the firmware file you have downloaded (and unzipped) the correct model firmware and version to your device. Be sure to upload the correct model firmware as shown next. It also allows you reboot. Make sure you wish to upload to the...
User Guide
Page 259
... technical background information on the topics discussed in the screens such as the Switch only recognizes "config" and "ras". GS2200-8/24 User's Guide 259 ZyNOS (ZyXEL Network Operating System sometimes referred to rename them as password, Switch setup, IP Setup, and so on your computer. ...Switch configurations, system-related data (including the default password), the error log and the trace log. Be sure to upload the correct model firmware as the "ras" file) is a sample FTP session saving the current configuration to the Switch. Table 103 Filename Conventions ...
... technical background information on the topics discussed in the screens such as the Switch only recognizes "config" and "ras". GS2200-8/24 User's Guide 259 ZyNOS (ZyXEL Network Operating System sometimes referred to rename them as password, Switch setup, IP Setup, and so on your computer. ...Switch configurations, system-related data (including the default password), the error log and the trace log. Be sure to upload the correct model firmware as the "ras" file) is a sample FTP session saving the current configuration to the Switch. Table 103 Filename Conventions ...
User Guide
Page 266
...of data encryption. Add Cancel Clear Index Username Security Level Authenticati on the Switch. This field displays the username of View-based Access Control Model (VACM) group. Click Cancel to MIBs. The username for the Administrator is a widely used (but breakable) method of this user ...to which users can both view and configure Switch changes. This field displays whether you change the default administrator password (1234). 266 GS2200-8/24 User's Guide Note: It is another method for data encryption that you want to five people (one administrator and four non-...
...of data encryption. Add Cancel Clear Index Username Security Level Authenticati on the Switch. This field displays the username of View-based Access Control Model (VACM) group. Click Cancel to MIBs. The username for the Administrator is a widely used (but breakable) method of this user ...to which users can both view and configure Switch changes. This field displays whether you change the default administrator password (1234). 266 GS2200-8/24 User's Guide Note: It is another method for data encryption that you want to five people (one administrator and four non-...
User Guide
Page 270
.... A manager station can manage and monitor the Switch through which network administrators perform network management functions. Figure 178 SNMP Management Model An SNMP managed network consists of packets received, node port status and so on. GetNext Allows the manager to retrieve an ...object variable from the managed switch into a form compatible with SNMP. SNMP is a collection of GetNext operations. 270 GS2200-8/24 User's Guide Examples of variables include number of two main components: agents and a manager. Chapter 35 Access Control 35.7 Technical...
.... A manager station can manage and monitor the Switch through which network administrators perform network management functions. Figure 178 SNMP Management Model An SNMP managed network consists of packets received, node port status and so on. GetNext Allows the manager to retrieve an ...object variable from the managed switch into a form compatible with SNMP. SNMP is a collection of GetNext operations. 270 GS2200-8/24 User's Guide Examples of variables include number of two main components: agents and a manager. Chapter 35 Access Control 35.7 Technical...
User Guide
Page 290
Table 121 ZyXEL Clustering Management Specifications Maximum number of the building are cluster members. In the following example, switch A in the same VLAN group so as to manage ... the other switches on the upper floors of cluster 24 members Cluster Member Models Must be able to communicate with ZyXEL cluster management implementation. Cluster Members The switches being managed by the cluster manager switch. Figure 192 Clustering Application Example GS2200-8/24 User's Guide 290 Cluster Management allows you manage the cluster member...
Table 121 ZyXEL Clustering Management Specifications Maximum number of the building are cluster members. In the following example, switch A in the same VLAN group so as to manage ... the other switches on the upper floors of cluster 24 members Cluster Member Models Must be able to communicate with ZyXEL cluster management implementation. Cluster Members The switches being managed by the cluster manager switch. Figure 192 Clustering Application Example GS2200-8/24 User's Guide 290 Cluster Management allows you manage the cluster member...
User Guide
Page 292
...Cluster Management Table 122 Management > Cluster Management: Status (continued) LABEL Model Status DESCRIPTION This field displays the model name. Offline shows approximately 1.5 minutes after the link between cluster member ...and manager goes down) 38.3 Clustering Management Configuration Use this screen to display the next screen. Click Management > Cluster Management > Configuration to configure clustering management. Figure 194 Management > Cluster Management > Configuration EXAMPLE 292 GS2200...
...Cluster Management Table 122 Management > Cluster Management: Status (continued) LABEL Model Status DESCRIPTION This field displays the model name. Offline shows approximately 1.5 minutes after the link between cluster member ...and manager goes down) 38.3 Clustering Management Configuration Use this screen to display the next screen. Click Management > Cluster Management > Configuration to configure clustering management. Figure 194 Management > Cluster Management > Configuration EXAMPLE 292 GS2200...
User Guide
Page 293
... set to the Switch's run -time memory. Add Click Add to save your changes to the same cluster. Remove Select this screen. GS2200-8/24 User's Guide 293 This is the VLAN ID and is only applicable if the Switch is displayed as Error in the Cluster Management...memory when you are done configuring. If multiple devices have the same password then hold [SHIFT] and click those switches to identify the Clustering Manager. Model This is displayed as Error in the Cluster Management Status screen and a warning icon ( ) appears in the member summary list below . Type ...
... set to the Switch's run -time memory. Add Click Add to save your changes to the same cluster. Remove Select this screen. GS2200-8/24 User's Guide 293 This is the VLAN ID and is only applicable if the Switch is displayed as Error in the Cluster Management...memory when you are done configuring. If multiple devices have the same password then hold [SHIFT] and click those switches to identify the Clustering Manager. Model This is displayed as Error in the Cluster Management Status screen and a warning icon ( ) appears in the member summary list below . Type ...
User Guide
Page 310
...one switch, called the cluster manager. You can configure the Switch to update the ARP table with with 64 bytes packets 310 GS2200-8/24 User's Guide Table 130 Feature Specifications L2 Bridging 16K MAC addresses (4-way associative hashed) Static MAC address filtering by source/... Restoration Cluster Management PPPoE IA CPU Protection Error Disable ARP Learning Note: Only upload firmware for your specific model! Firmware Upgrade Download new firmware (when available) from the ZyXEL web site and use to manage switches through a port on the Switch. You can set the Switch to...
...one switch, called the cluster manager. You can configure the Switch to update the ARP table with with 64 bytes packets 310 GS2200-8/24 User's Guide Table 130 Feature Specifications L2 Bridging 16K MAC addresses (4-way associative hashed) Static MAC address filtering by source/... Restoration Cluster Management PPPoE IA CPU Protection Error Disable ARP Learning Note: Only upload firmware for your specific model! Firmware Upgrade Download new firmware (when available) from the ZyXEL web site and use to manage switches through a port on the Switch. You can set the Switch to...
User Guide
Page 313
...High Power over Ethernet (GS2200-8HP only) IEEE802.3az Energy Efficient Ethernet (EEE) (GS2200-8 and GS22008HP only) Safety UL 60950-1 (GS2200-8/8HP only) CSA 60950-1 (GS2200-24/24P only) CNS 14336-1 (GS2200-8/8HP only) EN 60950-1 ...GS2200-8/8HP only) GS2200-8/24 User's Guide 313 Tunnel Protocol Attribute Link Layer Discovery Protocol (LLDP) Connectivity Fault Management (CFM) Port Based Network Access Control MAC Bridges Traffic Types - Vendor Specific Attribute PING-MIB fand TRACEROUTE-MIB DHCP Relay Syslog Internet Group Management Protocol, Version 3 User-based Security Model...
...High Power over Ethernet (GS2200-8HP only) IEEE802.3az Energy Efficient Ethernet (EEE) (GS2200-8 and GS22008HP only) Safety UL 60950-1 (GS2200-8/8HP only) CSA 60950-1 (GS2200-24/24P only) CNS 14336-1 (GS2200-8/8HP only) EN 60950-1 ...GS2200-8/8HP only) GS2200-8/24 User's Guide 313 Tunnel Protocol Attribute Link Layer Discovery Protocol (LLDP) Connectivity Fault Management (CFM) Port Based Network Access Control MAC Bridges Traffic Types - Vendor Specific Attribute PING-MIB fand TRACEROUTE-MIB DHCP Relay Syslog Internet Group Management Protocol, Version 3 User-based Security Model...
User Guide
Page 324
... passwords 293 cluster manager 290, 293 cluster member 290, 293 cluster member firmware upgrade 295 network example 290 setup 292 specification 290 status 291 switch models 290 VID 293 web configurator 294 cluster manager 290 cluster member 290 Common and Internal Spanning Tree, See CIST 127 configuration 239 change running config... 130 error disable detect 233 error disable recovery configuration 234 overview 231 Ethernet broadcast address 250, 299 Ethernet port test 286 external authentication server 183 GS2200-8/24 User's Guide
... passwords 293 cluster manager 290, 293 cluster member 290, 293 cluster member firmware upgrade 295 network example 290 setup 292 specification 290 status 291 switch models 290 VID 293 web configurator 294 cluster manager 290 cluster member 290 Common and Internal Spanning Tree, See CIST 127 configuration 239 change running config... 130 error disable detect 233 error disable recovery configuration 234 overview 231 Ethernet broadcast address 250, 299 Ethernet port test 286 external authentication server 183 GS2200-8/24 User's Guide
User Guide
Page 329
... System Plus) 182 tagged VLAN 83 temperature 308 329 SNMP 270 agent 270 and MIB 270 and security 271 authentication 265, 266 communities 263 management model 270 manager 270 MIB 271 network components 270 object variables 270 protocol operations 270 security 265, 266 setup 262 trap group 264 users 265 version... 143 Static VLAN 88 static VLAN control 89 tagging 89 status 40, 61 link aggregation 139 MSTP 123 port 61 port details 63 power 68 GS2200-8/24 User's Guide STP 115, 118 VLAN 86 STP 109, 222 bridge ID 116, 119 bridge priority 114, 117 configuration 114, 117 designated bridge 110...
... System Plus) 182 tagged VLAN 83 temperature 308 329 SNMP 270 agent 270 and MIB 270 and security 271 authentication 265, 266 communities 263 management model 270 manager 270 MIB 271 network components 270 object variables 270 protocol operations 270 security 265, 266 setup 262 trap group 264 users 265 version... 143 Static VLAN 88 static VLAN control 89 tagging 89 status 40, 61 link aggregation 139 MSTP 123 port 61 port details 63 power 68 GS2200-8/24 User's Guide STP 115, 118 VLAN 86 STP 109, 222 bridge ID 116, 119 bridge priority 114, 117 configuration 114, 117 designated bridge 110...