Installation Instructions
Page 5
Stainless steel baffle filters (depending on model size) 1 - Remote Control Remove all THERMADOR® appliance packaging material is recyclable. Filter spacers 2 or 3 - Liner (VCIBxxJP models only) 4 - Halogen lights (installed) 1 - Lock service panel to ...saw or jigsaw Tape measure Phillips head screwdriver Protective work gloves Available Accessories LINER236 - 36" Custom Hood Liner (VCIN models only) LINER248 - 48" Custom Hood Liner (VCIN models only) LINER254 - 54" Custom Hood Liner (VCIN models only) VCI2REMKS - Advance Planning Before You Begin Parts Included 1 - 1000...
Stainless steel baffle filters (depending on model size) 1 - Remote Control Remove all THERMADOR® appliance packaging material is recyclable. Filter spacers 2 or 3 - Liner (VCIBxxJP models only) 4 - Halogen lights (installed) 1 - Lock service panel to ...saw or jigsaw Tape measure Phillips head screwdriver Protective work gloves Available Accessories LINER236 - 36" Custom Hood Liner (VCIN models only) LINER248 - 48" Custom Hood Liner (VCIN models only) LINER254 - 54" Custom Hood Liner (VCIN models only) VCI2REMKS - Advance Planning Before You Begin Parts Included 1 - 1000...
Installation Instructions
Page 6
.../16" (17 mm) Table 1: VCIN Custom Insert Overall Dimensions English 4 General Information This manual provides the proper installation instructions for two styles of THERMADOR PROFESSIONAL® custom insert hoods: VCINxxJP Overall Dimensions VCINxxJP - 22" (559 mm) in depth and with widths of 33¾" (857 mm), 45¾" (1,162 mm) or 51...
.../16" (17 mm) Table 1: VCIN Custom Insert Overall Dimensions English 4 General Information This manual provides the proper installation instructions for two styles of THERMADOR PROFESSIONAL® custom insert hoods: VCINxxJP Overall Dimensions VCINxxJP - 22" (559 mm) in depth and with widths of 33¾" (857 mm), 45¾" (1,162 mm) or 51...
Installation Instructions
Page 7
... widths of 41½" (1,054 mm), 52½" (1,334 mm) or 58½" (1,486 mm). This model series features brushed stainless-steel filters, halogen lights, hood liner, and a 1000CFM integral blower. 15/8" (42mm) 45/16" (110 mm) Top View 21¾" (553 mm) A B 24¾" (629 mm) C 36 po 40½...
... widths of 41½" (1,054 mm), 52½" (1,334 mm) or 58½" (1,486 mm). This model series features brushed stainless-steel filters, halogen lights, hood liner, and a 1000CFM integral blower. 15/8" (42mm) 45/16" (110 mm) Top View 21¾" (553 mm) A B 24¾" (629 mm) C 36 po 40½...
Installation Instructions
Page 8
...82 lb (37.20 kg) VCIB36JP 96 lb (43.54 kg) VCIB48JP 111 lb (50.35 kg) VCIB54JP 122 lb (55.34 kg) IMPORTANT: The supplied weights address only the ventilation unit and blower. Hood installation height above a cooktop, rangetop or range, consult the appliance's ...installation manual. Distance From Cooking Surface The installation height ranges from heat if a THERMADOR PROFESSIONAL® series range or rangetop is installed at minimum ...
...82 lb (37.20 kg) VCIB36JP 96 lb (43.54 kg) VCIB48JP 111 lb (50.35 kg) VCIB54JP 122 lb (55.34 kg) IMPORTANT: The supplied weights address only the ventilation unit and blower. Hood installation height above a cooktop, rangetop or range, consult the appliance's ...installation manual. Distance From Cooking Surface The installation height ranges from heat if a THERMADOR PROFESSIONAL® series range or rangetop is installed at minimum ...
Installation Instructions
Page 9
...the heated portion of air movement. For safety reasons, ducting should be used in conjunction with a minimum diameter of duct. Hoods are not recommended. To calculate the equivalent straight duct run pressure, you have an additional backdraft damper installed to minimize backward ...possible to specific installations. Local building codes may require the use of make -up air systems when using a 10" (254 mm) duct, THERMADOR® recommends not exceeding 150 ft (46 m) of 6" (150 mm). A locally supplied transition is dependent upon proper ducting. It is...
...the heated portion of air movement. For safety reasons, ducting should be used in conjunction with a minimum diameter of duct. Hoods are not recommended. To calculate the equivalent straight duct run pressure, you have an additional backdraft damper installed to minimize backward ...possible to specific installations. Local building codes may require the use of make -up air systems when using a 10" (254 mm) duct, THERMADOR® recommends not exceeding 150 ft (46 m) of 6" (150 mm). A locally supplied transition is dependent upon proper ducting. It is...
Installation Instructions
Page 11
...(444 mm) Figure 4: Transition Centerline 1. Remove transition from inside of the hood. 4. Figure 3: Transition Cutout English 9 Remove tape holding damper closed. Assembly of hood. Discard brackets attaching transition to hood using two (2) 1" (25.4 mm) sheet metal screws included with aluminum tape.... Seal connection between transition and hood with hood. 5. Align mounting holes at base of transition ...
...(444 mm) Figure 4: Transition Centerline 1. Remove transition from inside of the hood. 4. Figure 3: Transition Cutout English 9 Remove tape holding damper closed. Assembly of hood. Discard brackets attaching transition to hood using two (2) 1" (25.4 mm) sheet metal screws included with aluminum tape.... Seal connection between transition and hood with hood. 5. Align mounting holes at base of transition ...
Installation Instructions
Page 12
...your local building codes for proper method of interior and exterior blower options (Remote, Inline or Integral) are available for THERMADOR PROFESSIONAL® custom insert series hoods. If the unit you have selected does not have a blower included, one must be grounded. For long duct runs ...with THERMADOR ventilation hoods. If there is easy access to escape. The hood should only be connected to a grounded socket that allows the electric current to duct line (in accordance with ...
...your local building codes for proper method of interior and exterior blower options (Remote, Inline or Integral) are available for THERMADOR PROFESSIONAL® custom insert series hoods. If the unit you have selected does not have a blower included, one must be grounded. For long duct runs ...with THERMADOR ventilation hoods. If there is easy access to escape. The hood should only be connected to a grounded socket that allows the electric current to duct line (in accordance with ...
Installation Instructions
Page 13
Attach four (4) nuts (included with an Integral Blower" on the mounting plate. Continue to the hood using weld studs provided on page 12. Guide the motor mounting plate over the studs. 3. Installation Instructions Blower Motor Installation BLOWER Integral... VTR1330E VTI610D VTI1010D Integral blower installation only 1. Tighten nuts to secure the blower to the weld studs. The blower is attached to "Wiring the Hood with hood) to the hood. 4. Figure 5 exhibits the weld stud locations. 2. CFM* 600 1000 600 1000 1300 600 1000 VOLTAGE (AC) BLOWER CURRENT (AMPS) 120 2.7 120 ...
Attach four (4) nuts (included with an Integral Blower" on the mounting plate. Continue to the hood using weld studs provided on page 12. Guide the motor mounting plate over the studs. 3. Installation Instructions Blower Motor Installation BLOWER Integral... VTR1330E VTI610D VTI1010D Integral blower installation only 1. Tighten nuts to secure the blower to the weld studs. The blower is attached to "Wiring the Hood with hood) to the hood. 4. Figure 5 exhibits the weld stud locations. 2. CFM* 600 1000 600 1000 1300 600 1000 VOLTAGE (AC) BLOWER CURRENT (AMPS) 120 2.7 120 ...
Installation Instructions
Page 14
... wire nuts rated for a minimum of two (2) #18 gauge wires and maximum of installation (VCIN models). Connect the power supply wires to the hood wires in junction box. 5. Close the junction box cover. Install 1" (25.4 mm) conduit connector in the following order: black to black, white... Use spring type wire nuts supplied. • Lost or missing wire nuts should only be replaced with an Integral Blower English 12 Wiring the Hood with the blower unit. 1. For complete installation instructions see Figure 5 on page 11). 2. Remove junction box channel covering the wires (see the...
... wire nuts rated for a minimum of two (2) #18 gauge wires and maximum of installation (VCIN models). Connect the power supply wires to the hood wires in junction box. 5. Close the junction box cover. Install 1" (25.4 mm) conduit connector in the following order: black to black, white... Use spring type wire nuts supplied. • Lost or missing wire nuts should only be replaced with an Integral Blower English 12 Wiring the Hood with the blower unit. 1. For complete installation instructions see Figure 5 on page 11). 2. Remove junction box channel covering the wires (see the...
Installation Instructions
Page 15
...wire nuts, rated for further wiring details. 9. Run five (5) #14 AWG wires in 1" (25.4 mm) conduit from the remote blower to the hood wires in the junction box. Close the junction box cover. For complete installation instructions see Figure 5 on page 11). 3. Use spring type wire nuts ...supplied. • Lost or missing wire nuts should only be installed with a Remote Blower English 13 Figure 9: Wiring the Hood with remote blowers (VCIN models). Wiring the Hood with a Remote Blower 13 5/8" 21/8" (346 mm) (54 mm) 121/8" 21/8" (308 mm) (54 mm) 17/8" (48 mm)...
...wire nuts, rated for further wiring details. 9. Run five (5) #14 AWG wires in 1" (25.4 mm) conduit from the remote blower to the hood wires in the junction box. Close the junction box cover. For complete installation instructions see Figure 5 on page 11). 3. Use spring type wire nuts ...supplied. • Lost or missing wire nuts should only be installed with a Remote Blower English 13 Figure 9: Wiring the Hood with remote blowers (VCIN models). Wiring the Hood with a Remote Blower 13 5/8" 21/8" (346 mm) (54 mm) 121/8" 21/8" (308 mm) (54 mm) 17/8" (48 mm)...
Installation Instructions
Page 16
... (5) wires (#14 AWG) in the following order: black to black, white to white, and green wire to the second conduit connector. 8. Figure 11: Wiring the Hood with the blower unit. 12 1/8" (308 mm) 12 " (305 mm) 7/8" (22 mm) ø 9 7/8" (251 mm) 19 1/8" (486 mm) 13/4" (44 mm) 12 7/8" (327 mm...; Lost or missing wire nuts should only be installed with inline blowers. Connect the "pigtail" to 600V and 302°F (150°C). 6. Wiring the Hood with an Inline Blower Both VCIN and VCIB custom insert models can be replaced with spring type wire nuts, rated for a minimum of two (2 #18...
... (5) wires (#14 AWG) in the following order: black to black, white to white, and green wire to the second conduit connector. 8. Figure 11: Wiring the Hood with the blower unit. 12 1/8" (308 mm) 12 " (305 mm) 7/8" (22 mm) ø 9 7/8" (251 mm) 19 1/8" (486 mm) 13/4" (44 mm) 12 7/8" (327 mm...; Lost or missing wire nuts should only be installed with inline blowers. Connect the "pigtail" to 600V and 302°F (150°C). 6. Wiring the Hood with an Inline Blower Both VCIN and VCIB custom insert models can be replaced with spring type wire nuts, rated for a minimum of two (2 #18...
Installation Instructions
Page 17
... b) Run harness through Partition c) Unplug harness from the remote control to Figure 5 on page 11). c) Remove three screws holding stainless steel panel to the hood after the hood is installed. 1. It is recommended that the Remote Control be wired to canopy. 2. Connecting the harness to the relay board a) Insert remote harness end...
... b) Run harness through Partition c) Unplug harness from the remote control to Figure 5 on page 11). c) Remove three screws holding stainless steel panel to the hood after the hood is installed. 1. It is recommended that the Remote Control be wired to canopy. 2. Connecting the harness to the relay board a) Insert remote harness end...
Installation Instructions
Page 19
Insert remote control into cutout. Secure from Figure 12 and Figure 13. Reinstall hood components from behind with the included 30 ft (914.4 cm) cable. 5. Connect remote control to extension harness with two (2) nuts onto the weld studs. 6. Figure 19: Remote Install English 17 4.
Insert remote control into cutout. Secure from Figure 12 and Figure 13. Reinstall hood components from behind with the included 30 ft (914.4 cm) cable. 5. Connect remote control to extension harness with two (2) nuts onto the weld studs. 6. Figure 19: Remote Install English 17 4.
Installation Instructions
Page 20
...mm) 19 13/16" (503 mm) 22 13/16" (579 mm) Back of Trim Back of the ventilation unit. See Table 3 on determining hood height. See "Installation Preparation" on page 6 for suggestions on page 6 for unit weight by model. Preparing VCINxxJP Housing Framework The unit must be sure... to include the weight of Hood 17/8" (47mm) 23" (584mm) 11/8" (29mm) 3 3/16" (81mm) A 77/8 " (200mm) 10¼" (260mm) 23/8" (86mm) 17/8 " (48mm) Diameter clearance holes for 1"...
...mm) 19 13/16" (503 mm) 22 13/16" (579 mm) Back of Trim Back of the ventilation unit. See Table 3 on determining hood height. See "Installation Preparation" on page 6 for suggestions on page 6 for unit weight by model. Preparing VCINxxJP Housing Framework The unit must be sure... to include the weight of Hood 17/8" (47mm) 23" (584mm) 11/8" (29mm) 3 3/16" (81mm) A 77/8 " (200mm) 10¼" (260mm) 23/8" (86mm) 17/8 " (48mm) Diameter clearance holes for 1"...
Installation Instructions
Page 23
...3. Build housing framework a) Refer to "Blower Motor Installation" beginning on page 10. Install the unit a) Install the custom insert inside the custom hood. Hidden surfaces may result in Figure 25. b) Install metal transition with eighteen (18) x ½" (12.7 mm) screws, as indicated... in "Preparing VCINxxJP Housing Framework" beginning on page 7. c) Build housing framework for applicable model according to the hood with backdraft damper so that the flap opens up toward the ceiling. Secure the trim to dimensions in Figure 26. 2" (50.8 mm...
...3. Build housing framework a) Refer to "Blower Motor Installation" beginning on page 10. Install the unit a) Install the custom insert inside the custom hood. Hidden surfaces may result in Figure 25. b) Install metal transition with eighteen (18) x ½" (12.7 mm) screws, as indicated... in "Preparing VCINxxJP Housing Framework" beginning on page 7. c) Build housing framework for applicable model according to the hood with backdraft damper so that the flap opens up toward the ceiling. Secure the trim to dimensions in Figure 26. 2" (50.8 mm...
Installation Instructions
Page 24
c) Connect wiring for another appliance. Plug electrical cord into grounded outlet. 9. Install hood filters, filter spacers, and grease trays a) Refer to ductwork 8. With the blower on high, close the windows and doors to the area to ensure that ...
c) Connect wiring for another appliance. Plug electrical cord into grounded outlet. 9. Install hood filters, filter spacers, and grease trays a) Refer to ductwork 8. With the blower on high, close the windows and doors to the area to ensure that ...
Installation Instructions
Page 25
See Table 3 on page 6 for suggestions for unit weight by model. Preparing VCIBxxJP Housing Framework The unit must be sure to include the weight of Hood 3 3/16" (81mm) 23" (584mm) 11/8" (29mm) 33/16" (81mm) A 77/8" (200mm) 10¼" (260mm) 23/8" (86mm) 17/8" (48mm) Diameter clearance ... (25.4mm) conduit to the surrounding housing. See "Installation Preparation" on page 6 for determining hood height. Build housing in accordance with the dimensions noted in Figure 28 thru Figure 32. Model A VCIB36JP VCIB48JP VCIB54JP 14 3/16" (360 mm) 19 13/16" (503 mm) 22 13/16" (579...
See Table 3 on page 6 for suggestions for unit weight by model. Preparing VCIBxxJP Housing Framework The unit must be sure to include the weight of Hood 3 3/16" (81mm) 23" (584mm) 11/8" (29mm) 33/16" (81mm) A 77/8" (200mm) 10¼" (260mm) 23/8" (86mm) 17/8" (48mm) Diameter clearance ... (25.4mm) conduit to the surrounding housing. See "Installation Preparation" on page 6 for determining hood height. Build housing in accordance with the dimensions noted in Figure 28 thru Figure 32. Model A VCIB36JP VCIB48JP VCIB54JP 14 3/16" (360 mm) 19 13/16" (503 mm) 22 13/16" (579...
Installation Instructions
Page 28
...housing framework for applicable model according to dimensions in Figure 35 and Figure 36. CAUTION: The hood weighs at least 60 lbs; Hood liner installation a) Slide the liner onto the hood (Figure 34). If necessary, install thermal break and additional backdraft damper (refer to "Assembly of... the housing. Failure to do so may have sharp edges. b) Refer to "Installation Preparation" on accidentally. 5. Secure the liner to the hood with backdraft damper so that the flap opens up toward the ceiling. b) Install metal transition with eighteen (18) x ½" (12.7 mm...
...housing framework for applicable model according to dimensions in Figure 35 and Figure 36. CAUTION: The hood weighs at least 60 lbs; Hood liner installation a) Slide the liner onto the hood (Figure 34). If necessary, install thermal break and additional backdraft damper (refer to "Assembly of... the housing. Failure to do so may have sharp edges. b) Refer to "Installation Preparation" on accidentally. 5. Secure the liner to the hood with backdraft damper so that the flap opens up toward the ceiling. b) Install metal transition with eighteen (18) x ½" (12.7 mm...
Installation Instructions
Page 29
... six (6) 2" (50.8 mm) mounting screws provided (Figure 37). 7. c) Connect wiring for blower motor (see blower instructions beginning on page 28. 10. Install Hood Filters and Grease Trays a) Refer to the sides of the frame using six (6) 2" (50.8 mm) mounting screws provided (Figure 38). 2" (50.8 mm) ...does not cause back drafting in the OFF position. Plug electrical cord into grounded outlet. 9. Install the Unit a) Install the custom insert inside the custom hood. ½" (12.7 mm) X6 each front & back side Figure 36: VCIB Secure Liner Front & Back 6. b) Remove circular knock-out holes...
... six (6) 2" (50.8 mm) mounting screws provided (Figure 37). 7. c) Connect wiring for blower motor (see blower instructions beginning on page 28. 10. Install Hood Filters and Grease Trays a) Refer to the sides of the frame using six (6) 2" (50.8 mm) mounting screws provided (Figure 38). 2" (50.8 mm) ...does not cause back drafting in the OFF position. Plug electrical cord into grounded outlet. 9. Install the Unit a) Install the custom insert inside the custom hood. ½" (12.7 mm) X6 each front & back side Figure 36: VCIB Secure Liner Front & Back 6. b) Remove circular knock-out holes...
Installation Instructions
Page 30
... 1 Filter Spacers Filter Spacers Filters Grease Tray Figure 39: Hood and parts NOTE: Do not use rangetop burners, elements, or oven while hood is disassembled. push down and in . Depending upon the size and model of hood, there will be in place before installing the filters. The... grease trays must be from hood pieces. 2. c) Filters - b) Filter spacers - Installing...
... 1 Filter Spacers Filter Spacers Filters Grease Tray Figure 39: Hood and parts NOTE: Do not use rangetop burners, elements, or oven while hood is disassembled. push down and in . Depending upon the size and model of hood, there will be in place before installing the filters. The... grease trays must be from hood pieces. 2. c) Filters - b) Filter spacers - Installing...