Installation Instructions
Page 2
..., Filter Spacers, & Grease Trays 28 Service 29 Before Calling Service 29 Product Data Rating Plate 29 Installer Checklist 29 To Clean & Protect Exterior Surfaces 30 THERMADOR® Service, Parts & Accessories back page This THERMADOR® appliance is made by BSH Home Appliances Corporation 1901 Main Street, Suite 600 Irvine, CA 92614 Questions? 1-800...
..., Filter Spacers, & Grease Trays 28 Service 29 Before Calling Service 29 Product Data Rating Plate 29 Installer Checklist 29 To Clean & Protect Exterior Surfaces 30 THERMADOR® Service, Parts & Accessories back page This THERMADOR® appliance is made by BSH Home Appliances Corporation 1901 Main Street, Suite 600 Irvine, CA 92614 Questions? 1-800...
Installation Instructions
Page 3
...or cleaning unit, switch power off at service panel and lock out panel before servicing the appliance. If you have a qualified electrician install an outlet near the appliance. If the power cord is too short, have questions, contact the manufacturer at the address or telephone... WARNING: Electrical Shock Hazard • Do not remove ground prong. • Do not use an adapter. • Do not use . Improper installation, service or maintenance can result in the manner intended by a qualified technician. Electric Safety WARNING: IMPROPER GROUNDING CAN RESULT IN A RISK OF ELECTRIC ...
...or cleaning unit, switch power off at service panel and lock out panel before servicing the appliance. If you have a qualified electrician install an outlet near the appliance. If the power cord is too short, have questions, contact the manufacturer at the address or telephone... WARNING: Electrical Shock Hazard • Do not remove ground prong. • Do not use an adapter. • Do not use . Improper installation, service or maintenance can result in the manner intended by a qualified technician. Electric Safety WARNING: IMPROPER GROUNDING CAN RESULT IN A RISK OF ELECTRIC ...
Installation Instructions
Page 4
... and vapors. Ventilation Safety WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: • Installation work and electrical wiring must be done by qualified person(s) in property damage or personal injury. Do not vent exhaust air into spaces within... Cooking and Food Serving Appliances • ANSI Z21.1, The American National Standard for the electric current. Use a quali¿ed and trained installer. To reduce the risk of fire, use only. Use caution when handling the appliance. To reduce the risk of fire or electric shock,...
... and vapors. Ventilation Safety WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: • Installation work and electrical wiring must be done by qualified person(s) in property damage or personal injury. Do not vent exhaust air into spaces within... Cooking and Food Serving Appliances • ANSI Z21.1, The American National Standard for the electric current. Use a quali¿ed and trained installer. To reduce the risk of fire, use only. Use caution when handling the appliance. To reduce the risk of fire or electric shock,...
Installation Instructions
Page 5
...LINER254 - 54" Custom Hood Liner (VCIN models only) VCI2REMKS - Use & Care Guide, Installation Manual, and Registration Card English 3 Remote Control Remove all THERMADOR® appliance packaging material is recyclable. Never allow children to prevent power from being turned ON ...accidentally. Halogen lights (installed) 1 - Advance Planning Before You Begin Parts Included 1 - 1000 CFM integral blower (...
...LINER254 - 54" Custom Hood Liner (VCIN models only) VCI2REMKS - Use & Care Guide, Installation Manual, and Registration Card English 3 Remote Control Remove all THERMADOR® appliance packaging material is recyclable. Never allow children to prevent power from being turned ON ...accidentally. Halogen lights (installed) 1 - Advance Planning Before You Begin Parts Included 1 - 1000 CFM integral blower (...
Installation Instructions
Page 6
... 13/16" (325 mm) 11/16" (17 mm) Table 1: VCIN Custom Insert Overall Dimensions English 4 General Information This manual provides the proper installation instructions for two styles of THERMADOR PROFESSIONAL® custom insert hoods: VCINxxJP Overall Dimensions VCINxxJP - 22" (559 mm) in depth and with widths of 33¾" (857 mm), 45...
... 13/16" (325 mm) 11/16" (17 mm) Table 1: VCIN Custom Insert Overall Dimensions English 4 General Information This manual provides the proper installation instructions for two styles of THERMADOR PROFESSIONAL® custom insert hoods: VCINxxJP Overall Dimensions VCINxxJP - 22" (559 mm) in depth and with widths of 33¾" (857 mm), 45...
Installation Instructions
Page 8
... above a cooktop, rangetop or range, consult the appliance's installation manual. Distance From Cooking Surface The installation height ranges from heat if a THERMADOR PROFESSIONAL® series range or rangetop is necessary to follow the cooking appliance manufacturer's installation instructions for proper hood height. 30" - 40" (762 -...37.20 kg) VCIB36JP 96 lb (43.54 kg) VCIB48JP 111 lb (50.35 kg) VCIB54JP 122 lb (55.34 kg) IMPORTANT: The supplied weights address only the ventilation unit and blower. Installation Preparation The custom insert unit is designed for ducting to ...
... above a cooktop, rangetop or range, consult the appliance's installation manual. Distance From Cooking Surface The installation height ranges from heat if a THERMADOR PROFESSIONAL® series range or rangetop is necessary to follow the cooking appliance manufacturer's installation instructions for proper hood height. 30" - 40" (762 -...37.20 kg) VCIB36JP 96 lb (43.54 kg) VCIB48JP 111 lb (50.35 kg) VCIB54JP 122 lb (55.34 kg) IMPORTANT: The supplied weights address only the ventilation unit and blower. Installation Preparation The custom insert unit is designed for ducting to ...
Installation Instructions
Page 9
... requirements and/or standards apply to compute permissible lengths for other sizes. Keep duct runs as short and straight as possible to specific installations. Back to locale. Hoods are supplied with a minimum diameter of the house. To calculate the equivalent straight duct run pressure, you...mm) round transition. MAKE-UP AIR: Local building codes may require the use of make -up air systems when using a 10" (254 mm) duct, THERMADOR® recommends not exceeding 150 ft (46 m) of outside wall cap. For example, assume you would add 12 ft (12.7 m) for each elbow,...
... requirements and/or standards apply to compute permissible lengths for other sizes. Keep duct runs as short and straight as possible to specific installations. Back to locale. Hoods are supplied with a minimum diameter of the house. To calculate the equivalent straight duct run pressure, you...mm) round transition. MAKE-UP AIR: Local building codes may require the use of make -up air systems when using a 10" (254 mm) duct, THERMADOR® recommends not exceeding 150 ft (46 m) of outside wall cap. For example, assume you would add 12 ft (12.7 m) for each elbow,...
Installation Instructions
Page 10
... Roof Cap 2' Long 3¼" x 10" Flex 6 2 7 2 8 2 N/A 20 3¼" x 10" to Round 10 1 7" Inline Backdraft 7 Damper 3¼" x 10" Roof Jack N/A and Shutter NOTE: These commonly used installation parts can be purchased at a local hardware store. Table 4: Duct Lengths English 8 THERMADOR® does not manufacture all these parts.
... Roof Cap 2' Long 3¼" x 10" Flex 6 2 7 2 8 2 N/A 20 3¼" x 10" to Round 10 1 7" Inline Backdraft 7 Damper 3¼" x 10" Roof Jack N/A and Shutter NOTE: These commonly used installation parts can be purchased at a local hardware store. Table 4: Duct Lengths English 8 THERMADOR® does not manufacture all these parts.
Installation Instructions
Page 12
.... In the event of an electrical short circuit, grounding reduces the risk of the duct run. Use only THERMADOR® blowers with the CAN 1- Blower selection will vary based on page 7). For indoor grill installations, THERMADOR recommends a minimum of 36" (914 mm) clearance to saturation with the National Electric Code ANSI/NFPA No...
.... In the event of an electrical short circuit, grounding reduces the risk of the duct run. Use only THERMADOR® blowers with the CAN 1- Blower selection will vary based on page 7). For indoor grill installations, THERMADOR recommends a minimum of 36" (914 mm) clearance to saturation with the National Electric Code ANSI/NFPA No...
Installation Instructions
Page 13
... nuts to secure the blower to the hood using weld studs provided on page 12. Guide the motor mounting plate over the studs. 3. Installation Instructions Blower Motor Installation BLOWER Integral Blower 600 CFM Integral Blower 1000 CFM Remote Blower 600 CFM Remote Blower 1000 CFM Remote Blower 1300 CFM Inline Blower 600... CFM Inline Blower 1000 CFM * CFM= Cubic feet per minute SKU VTN630C VTN1030C VTR630D VTR1030D VTR1330E VTI610D VTI1010D Integral blower installation only 1. Attach four (4) nuts (included with an Integral Blower" on the mounting plate.
... nuts to secure the blower to the hood using weld studs provided on page 12. Guide the motor mounting plate over the studs. 3. Installation Instructions Blower Motor Installation BLOWER Integral Blower 600 CFM Integral Blower 1000 CFM Remote Blower 600 CFM Remote Blower 1000 CFM Remote Blower 1300 CFM Inline Blower 600... CFM Inline Blower 1000 CFM * CFM= Cubic feet per minute SKU VTN630C VTN1030C VTR630D VTR1030D VTR1330E VTI610D VTI1010D Integral blower installation only 1. Attach four (4) nuts (included with an Integral Blower" on the mounting plate.
Installation Instructions
Page 14
... hood at the time of four (4) #14 gauge wires, UL & CSA rated to the connector present inside the hood, as shown in junction box. 5. Install 1" (25.4 mm) conduit connector in Figure 7. 4. Close the junction box cover. From Control Panel Figure 7: Wiring the Hood with spring type wire nuts ...rated for a minimum of two (2) #18 gauge wires and maximum of installation (VCIN models). Connect the power supply wires to the hood wires in 1" (25.4 mm) conduit from the power supply to green ground screw on...
... hood at the time of four (4) #14 gauge wires, UL & CSA rated to the connector present inside the hood, as shown in junction box. 5. Install 1" (25.4 mm) conduit connector in Figure 7. 4. Close the junction box cover. From Control Panel Figure 7: Wiring the Hood with spring type wire nuts ...rated for a minimum of two (2) #18 gauge wires and maximum of installation (VCIN models). Connect the power supply wires to the hood wires in 1" (25.4 mm) conduit from the power supply to green ground screw on...
Installation Instructions
Page 15
... junction box. Use spring type wire nuts supplied. • Lost or missing wire nuts should only be installed with remote blowers (VCIN models). Refer to the blower installation instructions for a minimum of two (2) #18 gauge wires and maximum of four (4) #14 gauge wires,... rated for further wiring details. 9. Remove circular knockouts (Figure 5 on chassis. Install 1" (25.4 mm) conduit connectors. 4. Connect the remote blower to the connector inside the junction box. 7. For complete installation instructions see Figure 5 on page 11). 2. Remove junction box channel covering the wires...
... junction box. Use spring type wire nuts supplied. • Lost or missing wire nuts should only be installed with remote blowers (VCIN models). Refer to the blower installation instructions for a minimum of two (2) #18 gauge wires and maximum of four (4) #14 gauge wires,... rated for further wiring details. 9. Remove circular knockouts (Figure 5 on chassis. Install 1" (25.4 mm) conduit connectors. 4. Connect the remote blower to the connector inside the junction box. 7. For complete installation instructions see Figure 5 on page 11). 2. Remove junction box channel covering the wires...
Installation Instructions
Page 16
...gauge wires and maximum of four (4) #14 gauge wires, UL & CSA rated to 600V and 302°F (150°C). 6. For complete installation instructions see Figure 5 on page 11). 3. Install 1" (25.4 mm) conduit connectors. 4. Connect the power supply wires to the hood wires in 1" (25.4 mm) conduit from power supply... to white, and green wire to junction box. 5. Use spring type wire nuts supplied. • Lost or missing wire nuts should only be installed with inline blowers. Close the junction box cover. Run black, white, and green wires (#12 AWG) in the junction box. 9. Connect the ...
...gauge wires and maximum of four (4) #14 gauge wires, UL & CSA rated to 600V and 302°F (150°C). 6. For complete installation instructions see Figure 5 on page 11). 3. Install 1" (25.4 mm) conduit connectors. 4. Connect the power supply wires to the hood wires in 1" (25.4 mm) conduit from power supply... to white, and green wire to junction box. 5. Use spring type wire nuts supplied. • Lost or missing wire nuts should only be installed with inline blowers. Close the junction box cover. Run black, white, and green wires (#12 AWG) in the junction box. 9. Connect the ...
Installation Instructions
Page 17
... grease trays. Figure 12: Remove stainless steel panel d) Remove core partition (Figure 13). Figure 13: Remove core partition English 15 Remote Control Installation (optional) NOTE: When using the Custom Insert with remote the unit loses the "AUTO" function and the over-temperature heat sensor described in ... box cover (refer to the hood after the hood is recommended that the Remote Control be wired to Figure 5 on page 11). It is installed. 1. c) Remove three screws holding stainless steel panel to the relay board a) Insert remote harness end into the mounting hole, as indicated in...
... grease trays. Figure 12: Remove stainless steel panel d) Remove core partition (Figure 13). Figure 13: Remove core partition English 15 Remote Control Installation (optional) NOTE: When using the Custom Insert with remote the unit loses the "AUTO" function and the over-temperature heat sensor described in ... box cover (refer to the hood after the hood is recommended that the Remote Control be wired to Figure 5 on page 11). It is installed. 1. c) Remove three screws holding stainless steel panel to the relay board a) Insert remote harness end into the mounting hole, as indicated in...
Installation Instructions
Page 18
d) Plug in harness included in Figure 18. 1½" (40 mm) 15/16" (23 mm) 11/16" (17 mm) 2¾" (69 mm) 11¾" (298 mm) 3/16" (5 mm) 11/16" (17 mm) ¼" (6 mm) 1½" (40 mm) 1 3/8" (35 mm) 3/8" (10 mm) 10 3/8" (263 mm) 1 3/8" (35 mm) 5/8" (17 mm) 9/16" (15 mm) Figure 18: Wall Cutout (view is shown facing wall) English 16 Figure 16: Relay Board Hookup Figure 17: Pigtail Remote Connection 3. Prepare wall or similar surface for installation as shown below in the remote kit (Figure 16). e) Connect the extension harness to the connector inside the junction box.
d) Plug in harness included in Figure 18. 1½" (40 mm) 15/16" (23 mm) 11/16" (17 mm) 2¾" (69 mm) 11¾" (298 mm) 3/16" (5 mm) 11/16" (17 mm) ¼" (6 mm) 1½" (40 mm) 1 3/8" (35 mm) 3/8" (10 mm) 10 3/8" (263 mm) 1 3/8" (35 mm) 5/8" (17 mm) 9/16" (15 mm) Figure 18: Wall Cutout (view is shown facing wall) English 16 Figure 16: Relay Board Hookup Figure 17: Pigtail Remote Connection 3. Prepare wall or similar surface for installation as shown below in the remote kit (Figure 16). e) Connect the extension harness to the connector inside the junction box.
Installation Instructions
Page 19
Reinstall hood components from behind with the included 30 ft (914.4 cm) cable. 5. 4. Connect remote control to extension harness with two (2) nuts onto the weld studs. 6. Insert remote control into cutout. Secure from Figure 12 and Figure 13. Figure 19: Remote Install English 17
Reinstall hood components from behind with the included 30 ft (914.4 cm) cable. 5. 4. Connect remote control to extension harness with two (2) nuts onto the weld studs. 6. Insert remote control into cutout. Secure from Figure 12 and Figure 13. Figure 19: Remote Install English 17
Installation Instructions
Page 20
See "Installation Preparation" on determining hood height. When calculating the load for 1" (25.4mm) conduit to include the weight of Hood 17/8" (47mm) 23" (584mm) 11/8" (29mm) 3 3/...
See "Installation Preparation" on determining hood height. When calculating the load for 1" (25.4mm) conduit to include the weight of Hood 17/8" (47mm) 23" (584mm) 11/8" (29mm) 3 3/...
Installation Instructions
Page 23
...personal injury. 1. c) Build housing framework for applicable model according to "Installation Preparation" on page 4 for clearance specifications. Install the unit a) Install the custom insert inside the custom hood. If necessary, install thermal break and additional backdraft damper (refer to prevent power from being... a) Refer to "Choosing the Correct Blower" on page 11. Secure the trim to "Blower Motor Installation" beginning on page 10. Turn power OFF at the service panel. b) Install metal transition with eighteen (18) x ½" (12.7 mm) screws, as indicated in Figure...
...personal injury. 1. c) Build housing framework for applicable model according to "Installation Preparation" on page 4 for clearance specifications. Install the unit a) Install the custom insert inside the custom hood. If necessary, install thermal break and additional backdraft damper (refer to prevent power from being... a) Refer to "Choosing the Correct Blower" on page 11. Secure the trim to "Blower Motor Installation" beginning on page 10. Turn power OFF at the service panel. b) Install metal transition with eighteen (18) x ½" (12.7 mm) screws, as indicated in Figure...
Installation Instructions
Page 24
...5 on page 11). d) Ensure all controls are in any outlet vent for applicable blower motor (see Figure 5 on page 28. 10. Test the installation a) Test the operation of the blower and the lights. Plug electrical cord into grounded outlet. 9. With the blower on high, close the windows and ...doors to the area to "Installing Grease Trays, Filter Spacers, and Filters" on page 11). Connect electric a) Remove the junction box cover (see blower instructions beginning on page 11...
...5 on page 11). d) Ensure all controls are in any outlet vent for applicable blower motor (see Figure 5 on page 28. 10. Test the installation a) Test the operation of the blower and the lights. Plug electrical cord into grounded outlet. 9. With the blower on high, close the windows and ...doors to the area to "Installing Grease Trays, Filter Spacers, and Filters" on page 11). Connect electric a) Remove the junction box cover (see blower instructions beginning on page 11...
Installation Instructions
Page 25
See Table 3 on page 6 for suggestions for the housing support system, be mounted to the surrounding housing. Model A VCIB36JP VCIB48JP VCIB54JP 14 3/16" (360 mm) 19 13/16" (503 mm) 22 13/16" (579 mm) Back of Liner Back of the ventilation unit. Build ...housing in accordance with the dimensions noted in Figure 28 thru Figure 32. See "Installation Preparation" on page 6 for 1" (25.4mm) conduit to junction box Figure 28: Transition and Conduit Cutout Dimensions English 23 Preparing VCIBxxJP Housing Framework The ...
See Table 3 on page 6 for suggestions for the housing support system, be mounted to the surrounding housing. Model A VCIB36JP VCIB48JP VCIB54JP 14 3/16" (360 mm) 19 13/16" (503 mm) 22 13/16" (579 mm) Back of Liner Back of the ventilation unit. Build ...housing in accordance with the dimensions noted in Figure 28 thru Figure 32. See "Installation Preparation" on page 6 for 1" (25.4mm) conduit to junction box Figure 28: Transition and Conduit Cutout Dimensions English 23 Preparing VCIBxxJP Housing Framework The ...