Operation Manual
Page 4
Table of Contents Chapter 1 Overview 1-1 Features 7 1-1-1 Principal Differences Between the PDW-510/510P and PDW-530/530P. 7 1-1-2 Camera Features 7 1-1-3 Features of the Optical Disc Drive (VDR 8 1-1-4 Inputs and Outputs 9 1-1-5 Other Functions 10 1-2 Example of System Configuration .. 11 1-3 Precautions 12 1-4 MPEG-4 ...
Table of Contents Chapter 1 Overview 1-1 Features 7 1-1-1 Principal Differences Between the PDW-510/510P and PDW-530/530P. 7 1-1-2 Camera Features 7 1-1-3 Features of the Optical Disc Drive (VDR 8 1-1-4 Inputs and Outputs 9 1-1-5 Other Functions 10 1-2 Example of System Configuration .. 11 1-3 Precautions 12 1-4 MPEG-4 ...
Operation Manual
Page 7
two filters can be used simultaneously 1) DVCAM is a trademark of Sony Corporation. 2) MPEG IMX is a trademark of effective pixels: approximately 500,000). PDW-510/510P recording format and internal optical filters Recording format DVCAM compatible recording Video Audio 25 Mbps DVCAM 1) format 16 ... image quality video recording using 2/3-inch high-definition CCDs of a 16:9 aspect ratio and a Professional Disc drive are common to the PDW510/510P and PDW-530/530P. 1-1-2 Camera Features 2/3-inch Power HAD EX CCDs The three high sensitivity, low smear 2/3-inch Power HAD1) EX CCDs provide...
two filters can be used simultaneously 1) DVCAM is a trademark of Sony Corporation. 2) MPEG IMX is a trademark of effective pixels: approximately 500,000). PDW-510/510P recording format and internal optical filters Recording format DVCAM compatible recording Video Audio 25 Mbps DVCAM 1) format 16 ... image quality video recording using 2/3-inch high-definition CCDs of a 16:9 aspect ratio and a Professional Disc drive are common to the PDW510/510P and PDW-530/530P. 1-1-2 Camera Features 2/3-inch Power HAD EX CCDs The three high sensitivity, low smear 2/3-inch Power HAD1) EX CCDs provide...
Operation Manual
Page 8
... the recorded video and audio by connecting the unit to a network with the CBK-NC01 Network Adaptor (option). 1) i.LINK is a trademark of Sony Corporation. Thus you can save menu settings for particular shooting conditions, for recall as required. 1) "Memory Stick" is a trademark of "Power Hole...settings in memory, so that of film. (PDW-510/530 only) 1) Abbreviation of Sony Corporation. Chapter 1 Overview • You can select an interlaced scan mode or progressive scan mode (30 fps (frames per second)2) for the PDW510/530, 25 fps for the PDW-510P/530P). • With the optional ...
... the recorded video and audio by connecting the unit to a network with the CBK-NC01 Network Adaptor (option). 1) i.LINK is a trademark of Sony Corporation. Thus you can save menu settings for particular shooting conditions, for recall as required. 1) "Memory Stick" is a trademark of "Power Hole...settings in memory, so that of film. (PDW-510/530 only) 1) Abbreviation of Sony Corporation. Chapter 1 Overview • You can select an interlaced scan mode or progressive scan mode (30 fps (frames per second)2) for the PDW510/530, 25 fps for the PDW-510P/530P). • With the optional ...
Operation Manual
Page 10
...disc or battery capacity is low, notication is provided by a menu operation. Color bars for maintenance and service (option) The SNMP-compliant Sony Remote Maintenance and Monitoring Software can be improved by the ability to use FTP commands to transfer files to remote locations over networks. 1-1-5 Other...panel The side of the unit has an LCD that can be assigned to any functions, by warning indicators and audible alarms. SMPTE (PDW-510/530)/EBU (PDW-510P/ 530P) color bars, and 1 kHz reference signal output Adjustment of a color monitor or external audio device is increased, making ...
...disc or battery capacity is low, notication is provided by a menu operation. Color bars for maintenance and service (option) The SNMP-compliant Sony Remote Maintenance and Monitoring Software can be improved by the ability to use FTP commands to transfer files to remote locations over networks. 1-1-5 Other...panel The side of the unit has an LCD that can be assigned to any functions, by warning indicators and audible alarms. SMPTE (PDW-510/530)/EBU (PDW-510P/ 530P) color bars, and 1 kHz reference signal output Adjustment of a color monitor or external audio device is increased, making ...
Operation Manual
Page 11
... SDI Output Board CBK-SD01 Composite Input Board CBK-SC01 Pull Down Board Network Adaptor CBK-FC01 2) CBK-NC01 Memory Card Adaptor CBK-PC01 2) For PDW-510/530 only Audio signal source External microphone ECM-670/678 or similar microphone CAC-12 Microphone Holder Audio equipment WRR-861/862 series UHF Portable...
... SDI Output Board CBK-SD01 Composite Input Board CBK-SC01 Pull Down Board Network Adaptor CBK-FC01 2) CBK-NC01 Memory Card Adaptor CBK-PC01 2) For PDW-510/530 only Audio signal source External microphone ECM-670/678 or similar microphone CAC-12 Microphone Holder Audio equipment WRR-861/862 series UHF Portable...
Operation Manual
Page 20
j Viewfinder left-right positioning ring Loosen this lever and the LOCK knob. For the PDW-510/510P FILTER selector setting and filter selection FILTER selector setting 1 2 3 4 Filter selection 3200 K 5600 K + 1/8 ND 5600 K 5600 K + 1/64 ND Examples of the ...follows. For details, see 7-2-4 "Setting the Marker Display" on the viewfinder screen for about 3 seconds. (e.g.: FILTER: 3) The PDW-510/510P has one switchable filter, and the PDW-530/530P has two switchable filters. i Viewfinder front-rear positioning lever To adjust the viewfinder position in black and white while shooting...
j Viewfinder left-right positioning ring Loosen this lever and the LOCK knob. For the PDW-510/510P FILTER selector setting and filter selection FILTER selector setting 1 2 3 4 Filter selection 3200 K 5600 K + 1/8 ND 5600 K 5600 K + 1/64 ND Examples of the ...follows. For details, see 7-2-4 "Setting the Marker Display" on the viewfinder screen for about 3 seconds. (e.g.: FILTER: 3) The PDW-510/510P has one switchable filter, and the PDW-530/530P has two switchable filters. i Viewfinder front-rear positioning lever To adjust the viewfinder position in black and white while shooting...
Operation Manual
Page 34
Lights in non-drop frame mode. (PDW-510/530 only) Lights when the camcorder is displayed. Lights when the HOLD button is pressed 1) Lights when the time code or real time is synchronized ...
Lights in non-drop frame mode. (PDW-510/530 only) Lights when the camcorder is displayed. Lights when the HOLD button is pressed 1) Lights when the time code or real time is synchronized ...
Operation Manual
Page 41
... processing for recording may not finish properly, which may cause the last few seconds of the FILTER knob. • For the PDW-530/530P: B: 3200 K, C: 4300 K, D: 6300 K • For the PDW-510/510P: 1: 3200 K, 3: 5600 K For details, see 5-3 "Setting the Electronic Shutter" on page 88. 5 To start recording, press the REC START button...
... processing for recording may not finish properly, which may cause the last few seconds of the FILTER knob. • For the PDW-530/530P: B: 3200 K, C: 4300 K, D: 6300 K • For the PDW-510/510P: 1: 3200 K, 3: 5600 K For details, see 5-3 "Setting the Electronic Shutter" on page 88. 5 To start recording, press the REC START button...
Operation Manual
Page 62
... the VIDEO OUT connector of the Recording - By pressing the PLAY/ PAUSE button, you can view the recorded picture. Color video monitor VIDEO IN connector 1) PDW-510/510P/530/530P SDI IN connector 2) VIDEO OUT connector 1) When VBS is selected as the output signal of the VIDEO OUT connector 2) When SDI is...
... the VIDEO OUT connector of the Recording - By pressing the PLAY/ PAUSE button, you can view the recorded picture. Color video monitor VIDEO IN connector 1) PDW-510/510P/530/530P SDI IN connector 2) VIDEO OUT connector 1) When VBS is selected as the output signal of the VIDEO OUT connector 2) When SDI is...
Operation Manual
Page 71
Chapter 4 Scene Selection Flow of scene selection editing Record material or insert disc containing recorded material into this unit To edit a clip list Disc PDW-510/510P/530/530P Load clip lists (see page 78) Create and edit a clip list • Selecting clips (see page 73) • Reordering sub clips (see ... 77) Clip 1 Clip 2 Clip 3 Clip list 1 Disc Play back the clip list (see page 64) Sub Clip Sub Sub 1 Clip 2 Clip 3 Play back clip list PDW-510/510P/530/530P 71 4-1 Overview
Chapter 4 Scene Selection Flow of scene selection editing Record material or insert disc containing recorded material into this unit To edit a clip list Disc PDW-510/510P/530/530P Load clip lists (see page 78) Create and edit a clip list • Selecting clips (see page 73) • Reordering sub clips (see ... 77) Clip 1 Clip 2 Clip 3 Clip list 1 Disc Play back the clip list (see page 64) Sub Clip Sub Sub 1 Clip 2 Clip 3 Play back clip list PDW-510/510P/530/530P 71 4-1 Overview
Operation Manual
Page 86
... 5 Adjustments and Settings for Recording FILTER selector (inner knob) setting and ND filter selection FILTER selector (inner knob) ND filter setting 4 1/64 ND For the PDW-510/510P: FILTER selector setting and filter selection FILTER selector setting Filter selection 1 3200 K 2 5600 K + 1/8 ND 3 5600 K 4 5600 K + 1/64 ND If the setting of the FILTER...
... 5 Adjustments and Settings for Recording FILTER selector (inner knob) setting and ND filter selection FILTER selector (inner knob) ND filter setting 4 1/64 ND For the PDW-510/510P: FILTER selector setting and filter selection FILTER selector setting Filter selection 1 3200 K 2 5600 K + 1/8 ND 3 5600 K 4 5600 K + 1/64 ND If the setting of the FILTER...
Operation Manual
Page 87
...Balance and the White Balance The color temperature is necessary. If the error message occurs again, an internal check is too low. Contact your Sony representative if this internal check, refer to the setting (A or B) of A and B can be stored. White balance memory Values stored...of memories allocated to PRST. If the WHITE BAL switch is set to B, and on the FILTER selector setting. • PDW-530/530P: B: 3200K, C: 4300 K, D: 6300K • PDW-510/510P: 1: 3200 K, 3: 5600 K For details about this message continues to appear even after the white balance and black ...
...Balance and the White Balance The color temperature is necessary. If the error message occurs again, an internal check is too low. Contact your Sony representative if this internal check, refer to the setting (A or B) of A and B can be stored. White balance memory Values stored...of memories allocated to PRST. If the WHITE BAL switch is set to B, and on the FILTER selector setting. • PDW-530/530P: B: 3200K, C: 4300 K, D: 6300K • PDW-510/510P: 1: 3200 K, 3: 5600 K For details about this message continues to appear even after the white balance and black ...
Operation Manual
Page 88
...Shutter Scan Mode:24P 1) when shooting 24.0 Hz to happen when the power supply frequency is 60 Hz (with the PDW-510/530) or 50 Hz (with the PDW-510P/530P). Notes • Whatever the operating mode of the electronic shutter, the sensitivity of the CCD decreases with increasing... of the PAINT menu. 5-3-2 Selecting the Shutter Mode and Shutter Speed Use the SHUTTER selector to 8, 16 frames (1/2 sec for PDW-510/530, 2/3 sec for PDW-510P/530P) For shooting subjects in low level lighting conditions Shutter mode Shutter speed EVS (Enhanced Vertical definition System) Shutter speed currently ...
...Shutter Scan Mode:24P 1) when shooting 24.0 Hz to happen when the power supply frequency is 60 Hz (with the PDW-510/530) or 50 Hz (with the PDW-510P/530P). Notes • Whatever the operating mode of the electronic shutter, the sensitivity of the CCD decreases with increasing... of the PAINT menu. 5-3-2 Selecting the Shutter Mode and Shutter Speed Use the SHUTTER selector to 8, 16 frames (1/2 sec for PDW-510/530, 2/3 sec for PDW-510P/530P) For shooting subjects in low level lighting conditions Shutter mode Shutter speed EVS (Enhanced Vertical definition System) Shutter speed currently ...
Operation Manual
Page 89
.../530P ECS mode Shutter speeds in standard mode can be switched to ECS. Standard mode (with scan mode:I) SLS mode 1/100: for PDW-510/530 1/60: for the frequency range which can also be changed. 89 5-3 Setting the Electronic Shutter By factory default, all standard-mode speeds listed in ...
.../530P ECS mode Shutter speeds in standard mode can be switched to ECS. Standard mode (with scan mode:I) SLS mode 1/100: for PDW-510/530 1/60: for the frequency range which can also be changed. 89 5-3 Setting the Electronic Shutter By factory default, all standard-mode speeds listed in ...
Operation Manual
Page 90
... connected You can be set the shutter speed of ECS with the rotary encoder of the OPERATION menu appears. The TOP menu appears. For the PDW-510P/530P, "SHUTTER 1/60" is the first time the OPERATION menu has been displayed, the CONTENTS page of the RM-B150. MENU knob MENU ON... shutter speed in the range 1 to 8, and 16. (1 frame nearly equals to ON while holding down the MENU knob. Chapter 5 Adjustments and Settings for the PDW-510/530. SLS: 1/30 : 1FRAME Example of shutter mode and speed settings 1 Set the MENU ON/OFF switch to 1/30 second...
... connected You can be set the shutter speed of ECS with the rotary encoder of the OPERATION menu appears. The TOP menu appears. For the PDW-510P/530P, "SHUTTER 1/60" is the first time the OPERATION menu has been displayed, the CONTENTS page of the RM-B150. MENU knob MENU ON... shutter speed in the range 1 to 8, and 16. (1 frame nearly equals to ON while holding down the MENU knob. Chapter 5 Adjustments and Settings for the PDW-510/530. SLS: 1/30 : 1FRAME Example of shutter mode and speed settings 1 Set the MENU ON/OFF switch to 1/30 second...
Operation Manual
Page 96
...in the Time Code Setting the PRESET/REGEN/CLOCK switch to 23 : 59 : 59 : 24 for the PDW-510P/530P. For details, see 7-3-6 "Setting the Date/Time of the Internal Clock" on the disc normally... produces consecutive time code. To set the drop frame mode/non-drop frame mode (only for the PDW-510/530) You can record user information such as follows. 1 RESET button 4 2 3 THUMBNAIL SEL/SET ...: 00 : 00 : 00 to 23 : 59 : 59 : 29 (hours : minutes : seconds : frames) for the PDW-510/530, and from 00 : 00 : 00 : 00 to CLOCK saves the actual time in the time code. R-RUN: Recording...
...in the Time Code Setting the PRESET/REGEN/CLOCK switch to 23 : 59 : 59 : 24 for the PDW-510P/530P. For details, see 7-3-6 "Setting the Date/Time of the Internal Clock" on the disc normally... produces consecutive time code. To set the drop frame mode/non-drop frame mode (only for the PDW-510/530) You can record user information such as follows. 1 RESET button 4 2 3 THUMBNAIL SEL/SET ...: 00 : 00 : 00 to 23 : 59 : 59 : 29 (hours : minutes : seconds : frames) for the PDW-510/530, and from 00 : 00 : 00 : 00 to CLOCK saves the actual time in the time code. R-RUN: Recording...
Operation Manual
Page 98
.../R-RUN switch to F-RUN. 4 Set the DISPLAY switch to TC. 5 Supply a time code signal and a reference video signal complying with the SMPTE (for PDW-510/530) or EBU (for PDW-510P/530P) standard and in proper phase relationship, to the TC IN connector and to R-RUN. This operation synchronizes the internal time code...
.../R-RUN switch to F-RUN. 4 Set the DISPLAY switch to TC. 5 Supply a time code signal and a reference video signal complying with the SMPTE (for PDW-510/530) or EBU (for PDW-510P/530P) standard and in proper phase relationship, to the TC IN connector and to R-RUN. This operation synchronizes the internal time code...
Operation Manual
Page 104
... 57): OFF • Unsaved current clip list: Save or clear 2 If this unit is confirmed. Note You will differ depending on the number of files PDW-510/510P/ 530/530P Laptop computer, etc. 4 Turn the MENU knob to the i.LINK (IEEE1394) connector on files Proceed as follows. 1 If there is a disc loaded...
... 57): OFF • Unsaved current clip list: Save or clear 2 If this unit is confirmed. Note You will differ depending on the number of files PDW-510/510P/ 530/530P Laptop computer, etc. 4 Turn the MENU knob to the i.LINK (IEEE1394) connector on files Proceed as follows. 1 If there is a disc loaded...
Operation Manual
Page 106
... enter a user name. 4 Enter the user name "admin" and press the Enter key. File data PDW-510/510P/ 530/530P Transfer of this unit is verified, your system. When the user name is set to "pdw-530 (or 510)" when the unit is connected to NETWORK. 6-3-1 Making FTP connections FTP connections between this unit...
... enter a user name. 4 Enter the user name "admin" and press the Enter key. File data PDW-510/510P/ 530/530P Transfer of this unit is verified, your system. When the user name is set to "pdw-530 (or 510)" when the unit is connected to NETWORK. 6-3-1 Making FTP connections FTP connections between this unit...
Operation Manual
Page 122
...input. The peak indication of recording, which are recorded on . However, if the SHUTTER selector is set to OFF, nothing is displayed. 1/100 (PDW-510/530) or 1/60 (PDW-510P/530P), 1/125, 1/250, 1/500, 1/1000, 1/2000: Shutter speed (in seconds) in standard mode (scan mode:I) 1/40, 1/60, 1/120... (PDW-510/530) or 1/33, 1/50, 1/100 (PDW-510P/530P), 1/125, 1/250, 1/500, 1/1000, 1/ 2000: Shutter speed (in seconds) in standard mode (scan mode:PsF) ECS: ECS mode EVS: EVS ...
...input. The peak indication of recording, which are recorded on . However, if the SHUTTER selector is set to OFF, nothing is displayed. 1/100 (PDW-510/530) or 1/60 (PDW-510P/530P), 1/125, 1/250, 1/500, 1/1000, 1/2000: Shutter speed (in seconds) in standard mode (scan mode:I) 1/40, 1/60, 1/120... (PDW-510/530) or 1/33, 1/50, 1/100 (PDW-510P/530P), 1/125, 1/250, 1/500, 1/1000, 1/ 2000: Shutter speed (in seconds) in standard mode (scan mode:PsF) ECS: ECS mode EVS: EVS ...