Hardware Installation Guide
Page 3
... Installation Package Contents 13 Protecting against Electrostatic Discharge 13 Unpack the Hardware 14 Installation 14 Select a Location 15 Install the Switch 16 Install the M4100-D12G or M4100-D10-PoE Using Magnets 19 Check the Installation 20 Connect to Power and Check the LEDs 20 SFP Modules 21 Connect Equipment to the Switch 22...
... Installation Package Contents 13 Protecting against Electrostatic Discharge 13 Unpack the Hardware 14 Installation 14 Select a Location 15 Install the Switch 16 Install the M4100-D12G or M4100-D10-PoE Using Magnets 19 Check the Installation 20 Connect to Power and Check the LEDs 20 SFP Modules 21 Connect Equipment to the Switch 22...
Hardware Installation Guide
Page 4
..., high-performance, IEEE-compliant network solutions. Front Panels and LEDs The following : M4100-26G M4100-50G M4100-26-POE M4100-26G-POE M4100-50G-POE+ M4100-50-POE M4100-D10-POE M4100-D12G M4100-12GF M4100-D12G-POE+ M4100-24G-POE+ M4100-12G-POE+ This guide describes hardware installation and basic troubleshooting for each product, visit the NETGEAR website at http://www.netgear.com. They include powerful management features that you can be freestanding, wall...
..., high-performance, IEEE-compliant network solutions. Front Panels and LEDs The following : M4100-26G M4100-50G M4100-26-POE M4100-26G-POE M4100-50G-POE+ M4100-50-POE M4100-D10-POE M4100-D12G M4100-12GF M4100-D12G-POE+ M4100-24G-POE+ M4100-12G-POE+ This guide describes hardware installation and basic troubleshooting for each product, visit the NETGEAR website at http://www.netgear.com. They include powerful management features that you can be freestanding, wall...
Hardware Installation Guide
Page 10
...injury, electrical shock, fire, and damage to help protect your system from potential damage. M4100-D10-POE and M4100-D12G rear panels Console port RPS Lock power supply connector Figure 15. M4100-D12G-POE+ rear panel AC power connector Safety Instructions Use the following precautions. • Observe ...24G-POE+, 12G-POE+ rear panel AC power connector Lock Console port Figure 16. Do not service any product except as explained in your own personal safety and to the equipment, observe the following safety guidelines to ensure your system documentation. 10 NETGEAR Managed...
...injury, electrical shock, fire, and damage to help protect your system from potential damage. M4100-D10-POE and M4100-D12G rear panels Console port RPS Lock power supply connector Figure 15. M4100-D12G-POE+ rear panel AC power connector Safety Instructions Use the following precautions. • Observe ...24G-POE+, 12G-POE+ rear panel AC power connector Lock Console port Figure 16. Do not service any product except as explained in your own personal safety and to the equipment, observe the following safety guidelines to ensure your system documentation. 10 NETGEAR Managed...
Hardware Installation Guide
Page 13
... • Rubber footpads for tabletop installation • Rubber caps for the SFP sockets • Rack-mounting kit • Wall-mounting kit (M4100-D10-POE, M4100-D12G, and M4100-D12G-POE+ only) • Magnetic mounting kit (M4100-D10-POE and M4100-D12G only) • USB console cable with one mini B connector and one type A connector • Resource CD: The CD includes...
... • Rubber footpads for tabletop installation • Rubber caps for the SFP sockets • Rack-mounting kit • Wall-mounting kit (M4100-D10-POE, M4100-D12G, and M4100-D12G-POE+ only) • Magnetic mounting kit (M4100-D10-POE and M4100-D12G only) • USB console cable with one mini B connector and one type A connector • Resource CD: The CD includes...
Hardware Installation Guide
Page 16
NETGEAR Managed Switch Install the Switch You can install the switch on a Flat Surface The switch ships with four self-adhesive rubber footpads. Install the Switch ... airflow and ease in servicing. Consider equipment nameplate ratings when addressing this , ground the rack itself. To install your switch in a Rack Note: The M4100-D10-PoE, M4100-D12G, and M4100-D12G-POE+ are not rack mountable. Hardware Installation 16 Keep the following considerations in a standard 19-inch rack. Therefore, consider installing the equipment in a rack...
NETGEAR Managed Switch Install the Switch You can install the switch on a Flat Surface The switch ships with four self-adhesive rubber footpads. Install the Switch ... airflow and ease in servicing. Consider equipment nameplate ratings when addressing this , ground the rack itself. To install your switch in a Rack Note: The M4100-D10-PoE, M4100-D12G, and M4100-D12G-POE+ are not rack mountable. Hardware Installation 16 Keep the following considerations in a standard 19-inch rack. Therefore, consider installing the equipment in a rack...
Hardware Installation Guide
Page 18
... Hammer caps into holes in the wall. 7. The exhaust air should have a minimum of 5 inches (130 millimeters) of the switch. 3. NETGEAR Managed Switch Install the Switch on a Wall (M4100-D12G, M4100-D10-PoE, and M4100-D12G-POE+ Only) If you install the switch on a wall in the vertical position, be mounted so that the ports face up...
... Hammer caps into holes in the wall. 7. The exhaust air should have a minimum of 5 inches (130 millimeters) of the switch. 3. NETGEAR Managed Switch Install the Switch on a Wall (M4100-D12G, M4100-D10-PoE, and M4100-D12G-POE+ Only) If you install the switch on a wall in the vertical position, be mounted so that the ports face up...
Hardware Installation Guide
Page 19
... (29.5 inches). Exhaust air should come out the side of the switch. 3. Hardware Installation 19 NETGEAR Managed Switch Install the M4100-D12G or M4100-D10-PoE Using Magnets If you use the magnets (included) to install the M4100-D12G or M4100-D10-PoE switch to a vertical metal surface, the maximum height above the floor. Press each of the 4 rubber...
... (29.5 inches). Exhaust air should come out the side of the switch. 3. Hardware Installation 19 NETGEAR Managed Switch Install the M4100-D12G or M4100-D10-PoE Using Magnets If you use the magnets (included) to install the M4100-D12G or M4100-D10-PoE switch to a vertical metal surface, the maximum height above the floor. Press each of the 4 rubber...
Hardware Installation Guide
Page 20
... cables are the RPS5412 and RPS4000. Note: Normally the M4100-D12G and M4100-D12G-POE+ will not create a safety hazard. 4. The switch is to the switch). NETGEAR Managed Switch Check the Installation Before you connect the power...have an on/off power to connect or disconnect the power cord. Note: The M4100-26G, 50G, 26-PoE, 26G-PoE, 50-PoE+, 50G-PoE, 12GF, 24G-POE+, 12G-POE+ can also obtain power from a PSE (power sourcing equipment) switch if AC...20 Connect one end of the AC power adapter cable (M4100-DG12 or M4100-D10-PoE) or the AC power cord to ensure that is not available.
... cables are the RPS5412 and RPS4000. Note: Normally the M4100-D12G and M4100-D12G-POE+ will not create a safety hazard. 4. The switch is to the switch). NETGEAR Managed Switch Check the Installation Before you connect the power...have an on/off power to connect or disconnect the power cord. Note: The M4100-26G, 50G, 26-PoE, 26G-PoE, 50-PoE+, 50G-PoE, 12GF, 24G-POE+, 12G-POE+ can also obtain power from a PSE (power sourcing equipment) switch if AC...20 Connect one end of the AC power adapter cable (M4100-DG12 or M4100-D10-PoE) or the AC power cord to ensure that is not available.
Hardware Installation Guide
Page 28
Fast Ethernet switches physical specifications Fast Ethernet Switches M4100-26-POE (FSM7226P) M4100-50-POE (FSM7250P) M4100-D10-POE (FSM5210P) Interface (AutoUplink on all RJ-45 ports) 24 RJ-45 ports for 10/100 ...2 SFP ports for 100/1000 Mbps 2 SFP ports for 100/1000 Mbps 2 SFP ports for 100/1000 Mbps 24 PoE ports 48 IEEE802.3af PoE 8 IEEE802.3af PoE 1 USB type A connector ports ports RS-232 console port 1 USB type A connector 1 USB type A connector 1...power consumption (W) (100-240V AC, 50-60 Hz) 456.29 486.64 87.30 Technical Specifications 28 NETGEAR Managed Switch Table 6.
Fast Ethernet switches physical specifications Fast Ethernet Switches M4100-26-POE (FSM7226P) M4100-50-POE (FSM7250P) M4100-D10-POE (FSM5210P) Interface (AutoUplink on all RJ-45 ports) 24 RJ-45 ports for 10/100 ...2 SFP ports for 100/1000 Mbps 2 SFP ports for 100/1000 Mbps 2 SFP ports for 100/1000 Mbps 24 PoE ports 48 IEEE802.3af PoE 8 IEEE802.3af PoE 1 USB type A connector ports ports RS-232 console port 1 USB type A connector 1 USB type A connector 1...power consumption (W) (100-240V AC, 50-60 Hz) 456.29 486.64 87.30 Technical Specifications 28 NETGEAR Managed Switch Table 6.
CLI Manual
Page 1
ProSafe Managed Switch Command Line Interface (CLI) User Manual 350 East Plumeria Drive San Jose, CA 95134 USA February 2013 202-11166-02 1.0 10.0.1 M7100-24X M4100-24G-POE+ M4100-26G M4100-26-POE M4100-26G-POE M4100-50G M4100-50-POE M4100-50G-POE+ M4100-12GF M4100-12G-POE+ M4100-D12G M4100-D10-POE M4100-D12G-POE+
ProSafe Managed Switch Command Line Interface (CLI) User Manual 350 East Plumeria Drive San Jose, CA 95134 USA February 2013 202-11166-02 1.0 10.0.1 M7100-24X M4100-24G-POE+ M4100-26G M4100-26-POE M4100-26G-POE M4100-50G M4100-50-POE M4100-50G-POE+ M4100-12GF M4100-12G-POE+ M4100-D12G M4100-D10-POE M4100-D12G-POE+
CLI Manual
Page 734
... Model Energy-Detect EEE M4100-D10-POE Yes No M4100-D12G Yes Yes M4100-50G-POE+ Yes Yes M4100-26G-POE Yes Yes M4100-50G Yes Yes M4100-26G Yes Yes M4100-50-POE Yes No M4100-26-POE Yes No M7100-24x No Yes M4100-12GF Yes No M4100-D12G-POE+ Yes No M4100-24G-POE+ Yes No M4100-12G-POE+ Yes No 734 13. Green Ethernet Commands 13 NETGEAR Managed Switch Release...
... Model Energy-Detect EEE M4100-D10-POE Yes No M4100-D12G Yes Yes M4100-50G-POE+ Yes Yes M4100-26G-POE Yes Yes M4100-50G Yes Yes M4100-26G Yes Yes M4100-50-POE Yes No M4100-26-POE Yes No M7100-24x No Yes M4100-12GF Yes No M4100-D12G-POE+ Yes No M4100-24G-POE+ Yes No M4100-12G-POE+ Yes No 734 13. Green Ethernet Commands 13 NETGEAR Managed Switch Release...