GS7xxTS User Manual
Page 6
GS700TS Smart Switch Software Administration Manual Chapter 3 Managing System Settings Using the System Settings Utility 3-1 Management ...3-1 System Information 3-1 IP Configuration ...3-4 Time ...3-5 Device View ...3-8 Stacking ...3-8 Operation Modes ...3-9 Understanding Stack Topology 3-9 Stacking Ports ...3-10 Stacking Members and Unit No 3-10 Removing and Replacing Stacking Members 3-11 Inserting a Stacking Member 3-12 Exchanging Stacking Members 3-12 Switching the Stacking...
GS700TS Smart Switch Software Administration Manual Chapter 3 Managing System Settings Using the System Settings Utility 3-1 Management ...3-1 System Information 3-1 IP Configuration ...3-4 Time ...3-5 Device View ...3-8 Stacking ...3-8 Operation Modes ...3-9 Understanding Stack Topology 3-9 Stacking Ports ...3-10 Stacking Members and Unit No 3-10 Removing and Replacing Stacking Members 3-11 Inserting a Stacking Member 3-12 Exchanging Stacking Members 3-12 Switching the Stacking...
GS7xxTS User Manual
Page 27
GS700TS Smart Switch Software Administration Manual Table 2-1. Selects the specified interface. Device Management Buttons Button Name Description CLEAR ALL CLEAR ALL COUNTERS CLEAR LOGS CURRENT MEMBERS DELETE GO REFRESH TAGGED PORT MEMBERS TEST UNTAGGED PORT MEMBERS Refreshes device information. Clears logs. Displays current members of a VLAN. Displays tagged port members of a LAG. Displays untagged port members of the...
GS700TS Smart Switch Software Administration Manual Table 2-1. Selects the specified interface. Device Management Buttons Button Name Description CLEAR ALL CLEAR ALL COUNTERS CLEAR LOGS CURRENT MEMBERS DELETE GO REFRESH TAGGED PORT MEMBERS TEST UNTAGGED PORT MEMBERS Refreshes device information. Clears logs. Displays current members of a VLAN. Displays tagged port members of a LAG. Displays untagged port members of the...
GS7xxTS User Manual
Page 31
GS700TS Smart Switch Software Administration Manual Deleting an Entry To delete entries from a table: 1. Click anywhere on a port level. The Unit 1 ports panel is displayed: Figure 2-10 2. Click APPLY to the Web Browser Interface 2-8 v1.0, June 2009 Special Table Options The NETGEAR web browser ...Buttons Gold Buttons provide flexibility in viewing and configuring VLANs/LAGs on the Unit 1 ports gold button. Introduction to update the device. To view the LAG configuration of the ports of Unit 1: 1. Select the Unit 1 ports to be deleted. 2. Select the entries to update...
GS700TS Smart Switch Software Administration Manual Deleting an Entry To delete entries from a table: 1. Click anywhere on a port level. The Unit 1 ports panel is displayed: Figure 2-10 2. Click APPLY to the Web Browser Interface 2-8 v1.0, June 2009 Special Table Options The NETGEAR web browser ...Buttons Gold Buttons provide flexibility in viewing and configuring VLANs/LAGs on the Unit 1 ports gold button. Introduction to update the device. To view the LAG configuration of the ports of Unit 1: 1. Select the Unit 1 ports to be deleted. 2. Select the entries to update...
GS7xxTS User Manual
Page 32
... that exist for this field. GS700TS Smart Switch Software Administration Manual Quick Boxes Quick Boxes provide users with flexibility in all the port boxes f for Unit 1, marking the ports as Tagged. To mark or unmark all ports (on a stacking unit level) or LAGs. Figure 2-11 2. Clicking on the... left of the gold button. This sets all Unit 1 ports as untagged. 2-9 Introduction to the...
... that exist for this field. GS700TS Smart Switch Software Administration Manual Quick Boxes Quick Boxes provide users with flexibility in all the port boxes f for Unit 1, marking the ports as Tagged. To mark or unmark all ports (on a stacking unit level) or LAGs. Figure 2-11 2. Clicking on the... left of the gold button. This sets all Unit 1 ports as untagged. 2-9 Introduction to the...
GS7xxTS User Manual
Page 33
... selected stacking unit. Introduction to toggle their tagged/untagged status Interface View and Selection A port or LAG interface may be selected from a table by using the interface selection row, located above the row of all ports in a stacking unit: 1. GS700TS Smart Switch Software Administration Manual Figure 2-13 4. You may click on the Unit No. Clicking...
... selected stacking unit. Introduction to toggle their tagged/untagged status Interface View and Selection A port or LAG interface may be selected from a table by using the interface selection row, located above the row of all ports in a stacking unit: 1. GS700TS Smart Switch Software Administration Manual Figure 2-13 4. You may click on the Unit No. Clicking...
GS7xxTS User Manual
Page 34
... an interface: 1. Click OK. To display the LAG table: 1. Click LAGS in the interface selection row. Click All in the interface selection row. The screen displays a table of the interface in the following example. 2-11 Introduction to the Web Browser Interface v1.0, June 2009 GS700TS Smart Switch Software Administration Manual To display all interfaces...
... an interface: 1. Click OK. To display the LAG table: 1. Click LAGS in the interface selection row. Click All in the interface selection row. The screen displays a table of the interface in the following example. 2-11 Introduction to the Web Browser Interface v1.0, June 2009 GS700TS Smart Switch Software Administration Manual To display all interfaces...
GS7xxTS User Manual
Page 94
... The navigation pane at the top of the web browser interface contains a Switching tab that follows in this chapter describes configuring and managing switching settings in the GS700TS Smart Switch. Ports The Ports menu contains the following main headings: • "Ports" • "LAG" • "VLAN" • "Voice VLAN" • "STP" • "Multicast" • "Address Table" The description that...
... The navigation pane at the top of the web browser interface contains a Switching tab that follows in this chapter describes configuring and managing switching settings in the GS700TS Smart Switch. Ports The Ports menu contains the following main headings: • "Ports" • "LAG" • "VLAN" • "Voice VLAN" • "STP" • "Multicast" • "Address Table" The description that...
GS7xxTS User Manual
Page 97
... a LAG lose their individual port configuration. LAG A Link Aggregated Group (LAG) optimizes port usage by linking a group of the same media type. • A VLAN is not configured on the port. • The port is not assigned to a different LAG. • Auto-negotiation mode is not configured on the port. • The port is applied to 16 ports, with Crossover) - GS700TS Smart Switch Software...
... a LAG lose their individual port configuration. LAG A Link Aggregated Group (LAG) optimizes port usage by linking a group of the same media type. • A VLAN is not configured on the port. • The port is not assigned to a different LAG. • Auto-negotiation mode is not configured on the port. • The port is applied to 16 ports, with Crossover) - GS700TS Smart Switch Software...
GS7xxTS User Manual
Page 98
... LAG description. • Status - GS700TS Smart Switch Software Administration Manual Basic The LAG Basic menu contains the following fields: • Interface - The system supports 8 LAGs, and each LAG can contain up to a suspended LAG. Indicates the LAG is currently not linked. • Reactivate Suspended - Select the current link operation. Displays the LAG number. • Description - Up - Down - Click Switching > LAG > Basic > LAG...
... LAG description. • Status - GS700TS Smart Switch Software Administration Manual Basic The LAG Basic menu contains the following fields: • Interface - The system supports 8 LAGs, and each LAG can contain up to a suspended LAG. Indicates the LAG is currently not linked. • Reactivate Suspended - Select the current link operation. Displays the LAG number. • Description - Up - Down - Click Switching > LAG > Basic > LAG...
GS7xxTS User Manual
Page 99
... negotiation. - Select the interface. 3. Click APPLY to its partner. GS700TS Smart Switch Software Administration Manual - Select the data transmission rate for the LAG. The possible field values are : - Indicates the LAG is enabled by default. The possible field values are : - Auto Negotiation is...Control - Select the flow control status of the LAG. The possible field values are : - Disable - Indicates the LAG is disabled by default. Indicates the interface supports transmission between two link partners that enables a port to advertise its link partner in the first row...
... negotiation. - Select the interface. 3. Click APPLY to its partner. GS700TS Smart Switch Software Administration Manual - Select the data transmission rate for the LAG. The possible field values are : - Indicates the LAG is enabled by default. The possible field values are : - Auto Negotiation is...Control - Select the flow control status of the LAG. The possible field values are : - Disable - Indicates the LAG is disabled by default. Indicates the interface supports transmission between two link partners that enables a port to advertise its link partner in the first row...
GS7xxTS User Manual
Page 100
GS700TS Smart Switch Software Administration Manual LAG Membership The Basic LAG Membership screen allows network managers to assign ports to update the device. 6. The Basic LAG Membership screen displays: Figure 4-3 The Basic LAG Membership screen contains the following fields: • LAG ID - Indicates the LAG is configured manually. - Click APPLY to LAGs. Select the LAG ID. • LAG Name - LACP - The possible field...
GS700TS Smart Switch Software Administration Manual LAG Membership The Basic LAG Membership screen allows network managers to assign ports to update the device. 6. The Basic LAG Membership screen displays: Figure 4-3 The Basic LAG Membership screen contains the following fields: • LAG ID - Indicates the LAG is configured manually. - Click APPLY to LAGs. Select the LAG ID. • LAG Name - LACP - The possible field...
GS7xxTS User Manual
Page 101
GS700TS Smart Switch Software Administration Manual Figure 4-4 Advanced The LAG Advanced menu contains the following options: • "LAG Configuration" • "LAG Membership" • "LACP Configuration" • "LACP Port Configuration" LAG Configuration The Advanced LAG Configuration screen contains fields for configuring LAG parameters. To define LAG parameters: 1. The system supports 8 LAGs, and each LAG can contain up to 8 ports. Click Switching > LAG > Advanced > LAG Configuration. The Advanced LAG Configuration...
GS700TS Smart Switch Software Administration Manual Figure 4-4 Advanced The LAG Advanced menu contains the following options: • "LAG Configuration" • "LAG Membership" • "LACP Configuration" • "LACP Port Configuration" LAG Configuration The Advanced LAG Configuration screen contains fields for configuring LAG parameters. To define LAG parameters: 1. The system supports 8 LAGs, and each LAG can contain up to 8 ports. Click Switching > LAG > Advanced > LAG Configuration. The Advanced LAG Configuration...
GS7xxTS User Manual
Page 102
... linked. • Reactivate Suspended - LACP - Up - Indicates the LAG is currently operating at 100 Mbps. 4-9 Configuring Switching Settings v1.0, June 2009 Enable - Indicates the LAG is configured manually. - Down - The LAG type determines what speed setting options are available. GS700TS Smart Switch Software Administration Manual Figure 4-5 The Advanced LAG Configuration screen contains the following fields: • Interface -
... linked. • Reactivate Suspended - LACP - Up - Indicates the LAG is currently operating at 100 Mbps. 4-9 Configuring Switching Settings v1.0, June 2009 Enable - Indicates the LAG is configured manually. - Down - The LAG type determines what speed setting options are available. GS700TS Smart Switch Software Administration Manual Figure 4-5 The Advanced LAG Configuration screen contains the following fields: • Interface -
GS7xxTS User Manual
Page 103
...v1.0, June 2009 4-10 Enter or modify the fields in full duplex mode. Click APPLY to LAGs: 1. GS700TS Smart Switch Software Administration Manual - 1000M - Displays the duplex mode of the LAG. The possible field values are: - Enables auto negotiation. - Disables auto negotiation. • Flow...- Disable - Select the flow control status of the LAG. Flow Control is not enabled on the LAG. • Auto Negotiation - Enable - Disabled - Operates when the port is enabled by default. To assign ports to update the device. Indicates the interface supports transmission...
...v1.0, June 2009 4-10 Enter or modify the fields in full duplex mode. Click APPLY to LAGs: 1. GS700TS Smart Switch Software Administration Manual - 1000M - Displays the duplex mode of the LAG. The possible field values are: - Enables auto negotiation. - Disables auto negotiation. • Flow...- Disable - Select the flow control status of the LAG. Flow Control is not enabled on the LAG. • Auto Negotiation - Enable - Disabled - Operates when the port is enabled by default. To assign ports to update the device. Indicates the interface supports transmission...
GS7xxTS User Manual
Page 104
... Displays the user-defined LAG name. • LAG Type - Static - LACP - GS700TS Smart Switch Software Administration Manual Figure 4-6 The Advanced LAG Membership screen contains the following fields: • LAG ID - The possible field values are: - Select the LAG ID and LAG Type. 3. The unit's port panel displays. 4. Select the ports to update the device. 6. Indicates the LAG is configured manually. - Click...
... Displays the user-defined LAG name. • LAG Type - Static - LACP - GS700TS Smart Switch Software Administration Manual Figure 4-6 The Advanced LAG Membership screen contains the following fields: • LAG ID - The possible field values are: - Select the LAG ID and LAG Type. 3. The unit's port panel displays. 4. Select the ports to update the device. 6. Indicates the LAG is configured manually. - Click...
GS7xxTS User Manual
Page 105
... contains a field for configuring a global LACP priority value. The LACP Configuration screen displays: Figure 4-8 Configuring Switching Settings v1.0, June 2009 4-12 Each group is comprised of ports with the same speed. Click Switching > LAG > Advanced > LACP Configuration. GS700TS Smart Switch Software Administration Manual Figure 4-7 LACP Configuration Aggregated links can be set up manually or automatically established...
... contains a field for configuring a global LACP priority value. The LACP Configuration screen displays: Figure 4-8 Configuring Switching Settings v1.0, June 2009 4-12 Each group is comprised of ports with the same speed. Click Switching > LAG > Advanced > LACP Configuration. GS700TS Smart Switch Software Administration Manual Figure 4-7 LACP Configuration Aggregated links can be set up manually or automatically established...
GS7xxTS User Manual
Page 106
... in the provided field. 3. The field range is 1-65535. This is 1. 2. GS700TS Smart Switch Software Administration Manual The LACP Configuration screen contains the following fields: • Interface - To configure LACP port priority: 1. Select the administrative LACP timeout. Click Switching > LAG > Advanced > LACP Port Configuration. The possible field values are assigned. • LACP Priority - Displays the interface...
... in the provided field. 3. The field range is 1-65535. This is 1. 2. GS700TS Smart Switch Software Administration Manual The LACP Configuration screen contains the following fields: • Interface - To configure LACP port priority: 1. Select the administrative LACP timeout. Click Switching > LAG > Advanced > LACP Port Configuration. The possible field values are assigned. • LACP Priority - Displays the interface...
GS7xxTS User Manual
Page 111
... • Group Operation - Indicates the VLAN is the default VLAN. Tag All - Click APPLY to the respective VLAN are : - Configuring Switching Settings v1.0, June 2009 4-18 Select the VLAN ID to the respective VLAN are : - VLAN ID 1 cannot be displayed and configured....- Removes all selected interfaces as tagged VLAN members. Static - Remove All - Packets belonging to update the device. Untag All - GS700TS Smart Switch Software Administration Manual Figure 4-12 The VLAN Membership screen contains the following fields: • VLAN ID - Default - Select the VLAN ID ...
... • Group Operation - Indicates the VLAN is the default VLAN. Tag All - Click APPLY to the respective VLAN are : - Configuring Switching Settings v1.0, June 2009 4-18 Select the VLAN ID to the respective VLAN are : - VLAN ID 1 cannot be displayed and configured....- Removes all selected interfaces as tagged VLAN members. Static - Remove All - Packets belonging to update the device. Untag All - GS700TS Smart Switch Software Administration Manual Figure 4-12 The VLAN Membership screen contains the following fields: • VLAN ID - Default - Select the VLAN ID ...
GS7xxTS User Manual
Page 112
GS700TS Smart Switch Software Administration Manual To tag or untag selected ports or LAGs: 1. Click Switching > VLAN > Advanced > VLAN Membership. The VLAN Membership screen displays. 2. Click APPLY to display the ports or LAGs. 3. The VLAN Membership screen displays. 2. The VLAN Membership screen displays. 2. To view VLAN tagged port members: 1. To tag or untag all the ports within a stacking unit or...
GS700TS Smart Switch Software Administration Manual To tag or untag selected ports or LAGs: 1. Click Switching > VLAN > Advanced > VLAN Membership. The VLAN Membership screen displays. 2. Click APPLY to display the ports or LAGs. 3. The VLAN Membership screen displays. 2. The VLAN Membership screen displays. 2. To view VLAN tagged port members: 1. To tag or untag all the ports within a stacking unit or...
GS7xxTS User Manual
Page 114
... deteriorate if the IP traffic is dropped from IP phones on which the PVID tag is assigned. • PVID - GS700TS Smart Switch Software Administration Manual Figure 4-15 The Port PVID Configuration screen contains the following fields: • Interface - Voice VLAN also provides QoS to carry IP Voice traffic from... the Voice VLAN in auto Voice VLAN secure mode. Select an interface. 3. Non-VoIP traffic is received unevenly. Displays the interface (port number or LAG number) to update the device. Click APPLY to which voice IP traffic is 1-4093. 2. Enter the PVID value.
... deteriorate if the IP traffic is dropped from IP phones on which the PVID tag is assigned. • PVID - GS700TS Smart Switch Software Administration Manual Figure 4-15 The Port PVID Configuration screen contains the following fields: • Interface - Voice VLAN also provides QoS to carry IP Voice traffic from... the Voice VLAN in auto Voice VLAN secure mode. Select an interface. 3. Non-VoIP traffic is received unevenly. Displays the interface (port number or LAG number) to update the device. Click APPLY to which voice IP traffic is 1-4093. 2. Enter the PVID value.