GS108T/ GS110TP Smart Switch Software Administration Manual
Page 2
...product updates, or get support online, visit us at http://support.netgear.com. Other brand and product names are registered trademarks or trademarks of Microsoft Corporation. GS108T and GS110TP Smart Switch Software Administration Manual ©2010 NETGEAR, Inc. NETGEAR does not assume any ...form or by any means without notice. Technical Support Thank you for choosing NETGEAR. Microsoft, Windows, Windows NT, and Vista are trademarks or registered trademarks of NETGEAR, Inc. Trademarks NETGEAR, the NETGEAR logo, ReadyNAS, ProSafe, Smart Control Center, Auto Uplink, X-RAID2, and...
...product updates, or get support online, visit us at http://support.netgear.com. Other brand and product names are registered trademarks or trademarks of Microsoft Corporation. GS108T and GS110TP Smart Switch Software Administration Manual ©2010 NETGEAR, Inc. NETGEAR does not assume any ...form or by any means without notice. Technical Support Thank you for choosing NETGEAR. Microsoft, Windows, Windows NT, and Vista are trademarks or registered trademarks of NETGEAR, Inc. Trademarks NETGEAR, the NETGEAR logo, ReadyNAS, ProSafe, Smart Control Center, Auto Uplink, X-RAID2, and...
GS108T/ GS110TP Smart Switch Software Administration Manual
Page 6
GS108T and GS110TP Smart Switch Software Administration Manual MAC Binding Configuration 184 MAC Binding Table 186 IP ACL 187 IP Rules 188 IP Extended Rule 189 IP Binding Configuration 193 IP Binding Table 194 Chapter 6 Monitoring the System Ports 196 Switch Statistics 196 Port Statistics 198 Port ...Multiple Port Mirroring 216 Chapter 7 Maintaining the System Reset 220 Device Reboot 220 Factory Default 221 Upload File From Switch 222 Download File To Switch 223 TFTP File Download 223 HTTP File Download 225 File Management 228 Dual Image Configuration 228 Dual Image Status ...
GS108T and GS110TP Smart Switch Software Administration Manual MAC Binding Configuration 184 MAC Binding Table 186 IP ACL 187 IP Rules 188 IP Extended Rule 189 IP Binding Configuration 193 IP Binding Table 194 Chapter 6 Monitoring the System Ports 196 Switch Statistics 196 Port Statistics 198 Port ...Multiple Port Mirroring 216 Chapter 7 Maintaining the System Reset 220 Device Reboot 220 Factory Default 221 Upload File From Switch 222 Download File To Switch 223 TFTP File Download 223 HTTP File Download 225 File Management 228 Dual Image Configuration 228 Dual Image Status ...
GS108T/ GS110TP Smart Switch Software Administration Manual
Page 29
...that can be created or modified. The main object for authentication and encryption, the switch supports only one profile that can manage traps that support additional switch functionality. To enable authentication, select an Authentication Protocol option, which is the page ... manager to the System SNMP SNMPv3 User Configuration page. 2. GS108T and GS110TP Smart Switch Software Administration Manual Using SNMP The switch software supports the configuration of eight or more alphanumeric characters in the Encryption Key field. 4. All private MIBs begin with...
...that can be created or modified. The main object for authentication and encryption, the switch supports only one profile that can manage traps that support additional switch functionality. To enable authentication, select an Authentication Protocol option, which is the page ... manager to the System SNMP SNMPv3 User Configuration page. 2. GS108T and GS110TP Smart Switch Software Administration Manual Using SNMP The switch software supports the configuration of eight or more alphanumeric characters in the Encryption Key field. 4. All private MIBs begin with...
GS108T/ GS110TP Smart Switch Software Administration Manual
Page 30
... MAC address. g1, g2, g3 LAG interfaces are logical interfaces that are numbered on the switch. GS108T and GS110TP Smart Switch Software Administration Manual Interface Naming Convention The switch support physical and logical interfaces. The physical ports are gigabit interfaces and are only used for all interfaces available on the front panel. Interface Physical Link Aggregation Group...
... MAC address. g1, g2, g3 LAG interfaces are logical interfaces that are numbered on the switch. GS108T and GS110TP Smart Switch Software Administration Manual Interface Naming Convention The switch support physical and logical interfaces. The physical ports are gigabit interfaces and are only used for all interfaces available on the front panel. Interface Physical Link Aggregation Group...
GS108T/ GS110TP Smart Switch Software Administration Manual
Page 36
GS108T and GS110TP Smart Switch Software Administration Manual port VLAN ID (PVID) of the VLAN ... zero is distanced from stratum 1 and above since it is performed by Stratums. Stratums define the accuracy of the switch. Stratum 1 time servers provide primary network time standards. • Stratum 2: The time source is the highest), ... configured as an SNTP client and cannot provide time services to the latest value of the reference clock. Time switch software supports the Simple Network Time Protocol (SNTP). Information received from a Stratum 1 server. You can be the same ...
GS108T and GS110TP Smart Switch Software Administration Manual port VLAN ID (PVID) of the VLAN ... zero is distanced from stratum 1 and above since it is performed by Stratums. Stratums define the accuracy of the switch. Stratum 1 time servers provide primary network time standards. • Stratum 2: The time source is the highest), ... configured as an SNTP client and cannot provide time services to the latest value of the reference clock. Time switch software supports the Simple Network Time Protocol (SNTP). Information received from a Stratum 1 server. You can be the same ...
GS108T/ GS110TP Smart Switch Software Administration Manual
Page 38
... format. To configure the time through SNTP: 1. Multiple modes may be supported by using the CPU's clock cycle. The options in SNTP Server Configuration on page 39. 5. GS108T and GS110TP Smart Switch Software Administration Manual To configure the time by a client. The switch gets the date and time from the network. 2. Configuration changes take effect...
... format. To configure the time through SNTP: 1. Multiple modes may be supported by using the CPU's clock cycle. The options in SNTP Server Configuration on page 39. 5. GS108T and GS110TP Smart Switch Software Administration Manual To configure the time by a client. The switch gets the date and time from the network. 2. Configuration changes take effect...
GS108T/ GS110TP Smart Switch Software Administration Manual
Page 39
... Date Encoded: The time provided by the SNTP server is not valid. • Version Not Supported: The SNTP version supported by the server is not compatible with the version supported by a stratum field equal to this server. Server Mode Specifies the mode of the SNTP Server...with the most current data from a server, a status of current valid unicast server entries configured for this client. GS108T and GS110TP Smart Switch Software Administration Manual Field Description Last Attempt Status Specifies the status of the server for the last received valid packet. To display the...
... Date Encoded: The time provided by the SNTP server is not valid. • Version Not Supported: The SNTP version supported by the server is not compatible with the version supported by a stratum field equal to this server. Server Mode Specifies the mode of the SNTP Server...with the most current data from a server, a status of current valid unicast server entries configured for this client. GS108T and GS110TP Smart Switch Software Administration Manual Field Description Last Attempt Status Specifies the status of the server for the last received valid packet. To display the...
GS108T/ GS110TP Smart Switch Software Administration Manual
Page 41
...a status of Other is indicated via the 'leap indicator' field on your switch. Requests Specifies the number of the following table describes the SNTP Global Status fields. GS108T and GS110TP Smart Switch Software Administration Manual The SNTP Server Status table displays status information about the SNTP ...Bad Date Encoded: The time provided by the SNTP server is not valid. • Version Not Supported: The SNTP version supported by the server is not compatible with the version supported by the client. • Server Unsynchronized: The SNTP server is indicated by a stratum field equal ...
...a status of Other is indicated via the 'leap indicator' field on your switch. Requests Specifies the number of the following table describes the SNTP Global Status fields. GS108T and GS110TP Smart Switch Software Administration Manual The SNTP Server Status table displays status information about the SNTP ...Bad Date Encoded: The time provided by the SNTP server is not valid. • Version Not Supported: The SNTP version supported by the server is not compatible with the version supported by the client. • Server Unsynchronized: The SNTP server is indicated by a stratum field equal ...
GS108T/ GS110TP Smart Switch Software Administration Manual
Page 42
... the size of ICMP Ping packets. Select a radio button to the switch. Click Apply to send the updated configuration to enable or disable Auto-DoS: • Disable. The switch software provides support for classifying and blocking specific types of Service (DoS) page to configure...Auto-DoS Configuration. You can monitor and block. To configure the Auto-DoS feature: 1. Configuration changes occur immediately. 3. GS108T and GS110TP Smart Switch Software Administration Manual Denial of Service Use the Denial of DoS attacks. To access the Auto-DoS Configuration page, click System ...
... the size of ICMP Ping packets. Select a radio button to the switch. Click Apply to send the updated configuration to enable or disable Auto-DoS: • Disable. The switch software provides support for classifying and blocking specific types of Service (DoS) page to configure...Auto-DoS Configuration. You can monitor and block. To configure the Auto-DoS feature: 1. Configuration changes occur immediately. 3. GS108T and GS110TP Smart Switch Software Administration Manual Denial of Service Use the Denial of DoS attacks. To access the Auto-DoS Configuration page, click System ...
GS108T/ GS110TP Smart Switch Software Administration Manual
Page 66
... possible values are True (enabled) or False (disabled). Auto-Negotiation Enabled Displays the port speed auto-negotiation support status. The possible values are True or False. The MAU performs physical layer functions, including digital data conversion...subtype. The following table describes the detailed local information that identifies the port. MAC/PHY Details Auto-Negotiation Supported Specifies whether the interface supports port-speed auto-negotiation. GS108T and GS110TP Smart Switch Software Administration Manual A popup window displays information for the selected port.
... possible values are True (enabled) or False (disabled). Auto-Negotiation Enabled Displays the port speed auto-negotiation support status. The possible values are True or False. The MAU performs physical layer functions, including digital data conversion...subtype. The following table describes the detailed local information that identifies the port. MAC/PHY Details Auto-Negotiation Supported Specifies whether the interface supports port-speed auto-negotiation. GS108T and GS110TP Smart Switch Software Administration Manual A popup window displays information for the selected port.
GS108T/ GS110TP Smart Switch Software Administration Manual
Page 67
GS108T and GS110TP Smart Switch Software Administration Manual Field MED Details Capabilities Supported Current Capabilities Device Class Network Policies Application Type VLAN ID VLAN Type User Priority DSCP Description Displays the MED capabilities enabled on the port. Specifies ...
GS108T and GS110TP Smart Switch Software Administration Manual Field MED Details Capabilities Supported Current Capabilities Device Class Network Policies Application Type VLAN ID VLAN Type User Priority DSCP Description Displays the MED capabilities enabled on the port. Specifies ...
GS108T/ GS110TP Smart Switch Software Administration Manual
Page 69
... (MSAP) entry number for the remote device. Port ID Identifies the physical address of the management address. GS108T and GS110TP Smart Switch Software Administration Manual Field Description Port Details Local Port Displays the interface on the local system that sent the information. The... the data was sent. The possible values are True or False Auto-Negotiation Enabled Displays the port speed auto-negotiation support status. The possible values are True or False Auto Negotiation Advertised Displays the port speed auto-negotiation capabilities. Address Specifies...
... (MSAP) entry number for the remote device. Port ID Identifies the physical address of the management address. GS108T and GS110TP Smart Switch Software Administration Manual Field Description Port Details Local Port Displays the interface on the local system that sent the information. The... the data was sent. The possible values are True or False Auto-Negotiation Enabled Displays the port speed auto-negotiation support status. The possible values are True or False Auto Negotiation Advertised Displays the port speed auto-negotiation capabilities. Address Specifies...
GS108T/ GS110TP Smart Switch Software Administration Manual
Page 70
...GS110TP Smart Switch Software Administration Manual Field MED Details Capabilities Supported Current Capabilities Device Class PoE Device Type PoE Power Source PoE Power Priority PoE Power Value Hardware Revision Firmware Revision Software Revision Serial Number Model Name Asset ID Location Information Civic Coordinates ECS ELIN Unknown Description Specifies the supported...device class, offering all Class 1 and Class 2 features plus location, 911, Layer 2 switch support and device information management capabilities. Displays the location map coordinates the remote device has advertised in...
...GS110TP Smart Switch Software Administration Manual Field MED Details Capabilities Supported Current Capabilities Device Class PoE Device Type PoE Power Source PoE Power Priority PoE Power Value Hardware Revision Firmware Revision Software Revision Serial Number Model Name Asset ID Location Information Civic Coordinates ECS ELIN Unknown Description Specifies the supported...device class, offering all Class 1 and Class 2 features plus location, 911, Layer 2 switch support and device information management capabilities. Displays the location map coordinates the remote device has advertised in...
GS108T/ GS110TP Smart Switch Software Administration Manual
Page 77
... • Disable: The port does not participate in SNMP. • ifIndex. Specify the maximum Ethernet frame size the interface supports or is used to support. Displays the bit offset value which can be one of the following : • Enable: Specifies that when the port link... to cancel the configuration on the screen and reset the data on the screen to the system. 10 | Chapter 3: Configuring Switching Information GS108T and GS110TP Smart Switch Software Administration Manual • Port Speed. Indicates the physical port's speed and duplex mode • Link Status. If you ...
... • Disable: The port does not participate in SNMP. • ifIndex. Specify the maximum Ethernet frame size the interface supports or is used to support. Displays the bit offset value which can be one of the following : • Enable: Specifies that when the port link... to cancel the configuration on the screen and reset the data on the screen to the system. 10 | Chapter 3: Configuring Switching Information GS108T and GS110TP Smart Switch Software Administration Manual • Port Speed. Indicates the physical port's speed and duplex mode • Link Status. If you ...
GS108T/ GS110TP Smart Switch Software Administration Manual
Page 79
... interface does not require a partner system to combine multiple full-duplex Ethernet links into a single logical link. The GS108T and GS110TP Smart Switches each support four LAGs. The LAG by default becomes a member of a LAG must participate in the same protocols. From the LAGs link..., you create a LAG. GS108T and GS110TP Smart Switch Software Administration Manual Link Aggregation Groups Link aggregation groups (LAGs), which are supported. Network devices treat the aggregation as if it neither transmits nor receives LAGPDUs. You ...
... interface does not require a partner system to combine multiple full-duplex Ethernet links into a single logical link. The GS108T and GS110TP Smart Switches each support four LAGs. The LAG by default becomes a member of a LAG must participate in the same protocols. From the LAGs link..., you create a LAG. GS108T and GS110TP Smart Switch Software Administration Manual Link Aggregation Groups Link aggregation groups (LAGs), which are supported. Network devices treat the aggregation as if it neither transmits nor receives LAGPDUs. You ...
GS108T/ GS110TP Smart Switch Software Administration Manual
Page 84
... or insert a tag using its default VLAN ID. To display the VLAN Configuration page, lick Switching VLAN Basic VLAN Configuration. GS108T and GS110TP Smart Switch Software Administration Manual VLANs Adding Virtual LAN (VLAN) support to a Layer 2 switch offers some of the benefits of multicast traffic. When you can access the following pages...
... or insert a tag using its default VLAN ID. To display the VLAN Configuration page, lick Switching VLAN Basic VLAN Configuration. GS108T and GS110TP Smart Switch Software Administration Manual VLANs Adding Virtual LAN (VLAN) support to a Layer 2 switch offers some of the benefits of multicast traffic. When you can access the following pages...
GS108T/ GS110TP Smart Switch Software Administration Manual
Page 94
...to behave entirely as a RSTP bridge or a STP bridge. The difference between end stations, avoiding and eliminating loops. GS108T and GS110TP Smart Switch Software Administration Manual Spanning Tree Protocol The Spanning Tree Protocol (STP) provides a tree topology for any arrangement of the Spanning Tree behaves...Rapid Spanning Tree (RSTP), with slight modifications in the same region, the force version should match. Spanning tree versions supported include Common STP, Multiple STP, and Rapid STP. For information on configuring Common STP, see CST Port Configuration on page 39 ...
...to behave entirely as a RSTP bridge or a STP bridge. The difference between end stations, avoiding and eliminating loops. GS108T and GS110TP Smart Switch Software Administration Manual Spanning Tree Protocol The Spanning Tree Protocol (STP) provides a tree topology for any arrangement of the Spanning Tree behaves...Rapid Spanning Tree (RSTP), with slight modifications in the same region, the force version should match. Spanning tree versions supported include Common STP, Multiple STP, and Rapid STP. For information on configuring Common STP, see CST Port Configuration on page 39 ...
GS108T/ GS110TP Smart Switch Software Administration Manual
Page 108
...• IGMP Snooping on page 42 • IGMP Snooping Querier on the screen to the latest value of the switch Chapter 3: Configuring Switching Information | 41 Click Apply to send the updated configuration to 239.255.255.255. To configure the Auto-Video feature...Video Configuration The Auto-Video feature simplifies IGMP Snooping Querier configuration if the switch supports devices or applications running multicast traffic, such as video surveillance cameras. GS108T and GS110TP Smart Switch Software Administration Manual Multicast Multicast IP traffic is traffic that is automatically ...
...• IGMP Snooping on page 42 • IGMP Snooping Querier on the screen to the latest value of the switch Chapter 3: Configuring Switching Information | 41 Click Apply to send the updated configuration to 239.255.255.255. To configure the Auto-Video feature...Video Configuration The Auto-Video feature simplifies IGMP Snooping Querier configuration if the switch supports devices or applications running multicast traffic, such as video surveillance cameras. GS108T and GS110TP Smart Switch Software Administration Manual Multicast Multicast IP traffic is traffic that is automatically ...
GS108T/ GS110TP Smart Switch Software Administration Manual
Page 117
GS108T and GS110TP Smart Switch Software Administration Manual inadvertent dropping of time in seconds that a switch will wait after sending a query on the VLAN because it did not receive a report for a particular group in that interface. Enter ... Timeout value. • MRouter Timeout. The default is supported only with the current multicast group membership on VLANs. To modify IGMP snooping settings for group membership interval of the switch. 3. IGMP Snooping Querier IGMP snooping requires that a switch will stop forwarding multicasts to configure and display information on ...
GS108T and GS110TP Smart Switch Software Administration Manual inadvertent dropping of time in seconds that a switch will wait after sending a query on the VLAN because it did not receive a report for a particular group in that interface. Enter ... Timeout value. • MRouter Timeout. The default is supported only with the current multicast group membership on VLANs. To modify IGMP snooping settings for group membership interval of the switch. 3. IGMP Snooping Querier IGMP snooping requires that a switch will stop forwarding multicasts to configure and display information on ...
GS108T/ GS110TP Smart Switch Software Administration Manual
Page 126
GS108T and GS110TP Smart Switch Software Administration Manual Class of Service The Class of Service (CoS) queueing ...default priority as untrusted, it uses a mapping table appropriate for different types of network traffic when the complexities of switch queueing. This process is also used for the mapping table to be configured to the appropriate outbound CoS queue through...on the appropriate egress port(s). Of course, the trusted field must exist in the switch can be forwarded on the appropriate egress port(s), in accordance with the configured default priority of any use, ...
GS108T and GS110TP Smart Switch Software Administration Manual Class of Service The Class of Service (CoS) queueing ...default priority as untrusted, it uses a mapping table appropriate for different types of network traffic when the complexities of switch queueing. This process is also used for the mapping table to be configured to the appropriate outbound CoS queue through...on the appropriate egress port(s). Of course, the trusted field must exist in the switch can be forwarded on the appropriate egress port(s), in accordance with the configured default priority of any use, ...