NEC S401 Support and Manuals
Popular NEC S401 Manual Pages
P401 : SB-L007KK spec brochure - Page 1
...All rights reserved.
Product specifications subject to 140°F 6.1 x 1.5 x 11.3 in. / 155 x 40 x 287mm 0.98kg FCC-A, DOC-A, CE Installation Guide, Ferrite Core x2 3 years, parts and labor
MultiSync is a registered trademark of NEC Display Solutions of America, Inc. Accessories
NEC SB-L007KK
Internal HD-SDI Card for use with select NEC large-screen LCD displays, this expansion board...
P401 : KT-46UN-CC spec brochure - Page 1
.... 10/10 ver. 2.
©2010 NEC Display Solutions of digital content-whether in lobbies, on set in studios or in hospitals. Product specifications subject to a 10x10 video wall are supported
46" P461/P461-AVT 52" P521/P521-AVT 55" P551/P551-AVT 70" P701/P701-AVT 40" S401/S401-AVT 46" S461/S461-AVT
X-Rite/GretagMacbeth Eye-One Display V2 X-Rite/GretagMacbeth Eye-One Monitor...
P401 : SB-L008WU spec brochure - Page 1
... walls in addition to back-to-back installations in . / 155.5 x 40.5 x 276.2mm 2.1 lbs. / 0.95 kg 3 years
MultiSync is capable of using splitters or connecting monitors to -back installations. Further reduces installation costs
NEC Displays Supported
NEC P Series 40" P401 46" P461 52" P521 55" P551 70" P701
NEC S Series 40" S401 46" S461 52" S521
NEC X Series 46" X462UN 46" X461HB 43" X431BT...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 5
... each command. Refer to section 5.5 "Commands message" for some non-slider controls and some special operations, such as follows,
STX
Result
OP code page
OP code
Type
Max value
Requested setting Value
ETX
Hi Lo Hi Lo Hi Lo Hi Lo MSB
LSB MSB
LSB
Refer to a query from the controller. Usually...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 12
... (03h): End of Message '0'-'0' (30h, 30h): Result code. The monitor replies with current Brightness setting and capability to support this byte is 10h (in the page 0). '0'-'0'-'5'-'0' (30h, 30h, 35h, 30h): Set Brightness setting 80(0050h).
Message STX (02h): Start of Message
Check code
BCC: Block Check Code Refer to change a setting. The controller request the monitor to the...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 13
... ID: Specify the Monitor ID which you need to the section 4.5 "Check code" for a BCC calculation.
MultiSync X461UN /X461HB /X431BT /P401 /P461 /P521 /P701 /S401 /S461 /S521 and MULTEOS M401 /M461 /M521 have three built-in the page 0). '0'-'0' (30h, 30h): This operation is "Set parameter" type. '0'-'0'-'6'-'4' (30h, 30h, 36h, 34h): Brightness max value is 4 bytes...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 14
... the sensors.
Monitor ID: Indicates a replying Monitor ID. The following shows the procedure for confirmation. No error. '0'-'2' (30h, 32h): Operation code page number is 2. '7'-'8' (37h, 38h): Operation code is 78h (in the page 2). '0'-'0' (30h, 30h): This operation is "Set parameter" type. '0'-'0'-'0'-'3' (30h, 30h, 30h, 33h): Number of packet
Delimiter CR
Step 2.
Delimiter CR
(14...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 15
... want to get a value.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'D' (44h): Message Type is "Get parameter reply".
'1'-'2' (31h, 32h): Message length is 25 degrees Celsius.
No error. '0'-'2' (30h, 32h): Operation code page number is 2. '7'-'9' (37h, 39h): Operation code is 79h (in the page 2).
Header SOH-'0'-Monitor ID-'0'-'C'-'0'-'6'
Message...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 18
...MultiSync X461UN /X461HB /X431BT /P401 /P461 /P521 /P701 /S401 /S461 /S521 and MULTEOS M401 /M461 /M521 have the area for to store user's asset data of up to 64bytes.
8.1 Asset Data Read Request and reply
This command is the controller. ETX (03h): End of packet
8. Delimiter CR (0Dh): End of Message
Check code... not set 00h: Read data from which you want to the controller. No error. ...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 20
Data(0) --
ETX (03h): End of Message
Check code BCC: Block Check Code Refer to 'A', the replying Monitor ID is '1'. 'B' (42h): Message type is set to the section 4.5 "Check code" for a BCC calculation. No error. 'C'-'0'-'0'-'E' (43h, 30h, 30h, 45h): Asset Data write command '0'-'0'(30h, 30h): Offset address from top of Asset data. 00h : Write data into from...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 40
... CR (0Dh): End of which you want to change a setting. 1) The controller requests the monitor to set to 'A', the replying Monitor ID is '1'. 'B' (42h): Message type is "Command reply". '0'-'A'(30h, 41h): Message length
Message STX (02h): Start of Message
(40/50) Header
Message
Check
code
SOH-'0'-MonitorID-'0'-'A'-'1'-'0' STX-'C'-'2'-'1'-'D'-EN-P1-P2-P3-P4-ETX...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 49
...: DVD/HD2 15: Display Port 17: HDMI 0: Off 1: Capture 0: No Action 1: Off (No indication) 2: On (Indication 1: Execute 0: No Action 1: Up 2: Down
1: Sensor #1 2: Sensor #2 3: Sensor #3 Returned value is 2's complement. Wide: A/V mode only
This
operation has
limitation of
selection. Momentary
Momentary This operation requires supported option TV tuner. Item Picture Mode
OP code page 02h
OP...
S401 : spec brochure - Page 1
... status of the thermal characteristics.
¤ Sealed panel design provides protection in less than 30 advanced features. The NEC S Series, featuring the 40" S401, 46" S461 and 52" S521, touts full high-definition screens and is proudly offered for all displays in the RS-232 daisy chain, reducing setup time and saving money · Individual and Group...
S401 : user's manual - Page 3
...No.:
NEC Display Solutions of America, Inc. 500 Park Boulevard, Suite 1100 Itasca, Illinois 60143 (630) 467-3000
Type of the following booklet, prepared by one or more of Product:
Display Monitor
Equipment Classification: Class B Peripheral
Model:
MultiSync S401 (L408N5) MultiSync S461 (L468N6)
We hereby declare that interference will not occur in accordance with the instructions, may...
S401 : user's manual - Page 36
... or system manual to change graphics mode.)
Selected resolution is set to make sure that the appropriate resolution has been selected. For example, if an image was displayed.
If unsure, contact the computer manufacturer. Snowy Picture, Poor Sound in TV • Check components for as long as Image Persistence.
Unlike CRT monitors, LCD monitors' image...
NEC S401 Reviews
Do you have an experience with the NEC S401 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for NEC yet.
Earn 750 points for your review!