(English) Hardware Password Manager Deployment Guide
Page 39
Scenario 6 - Removing the CMOS battery will inform the user that the system board is replaced, the POP, SVP, hardware account, and server credentials no longer be retrieved using a Lenovo-supplied Hardware Password Manager DOS utility. Scenario 7 - Replace or move a hard disk drive If the hard disk of the ...exist) and clear all detected drives. In this case, you must have the HDD ID for the hard disk in order for ThinkPad systems. When an unprotected hard disk is added to a Hardware Password Manager registered system, the BIOS will recognize that the hard disk...
Scenario 6 - Removing the CMOS battery will inform the user that the system board is replaced, the POP, SVP, hardware account, and server credentials no longer be retrieved using a Lenovo-supplied Hardware Password Manager DOS utility. Scenario 7 - Replace or move a hard disk drive If the hard disk of the ...exist) and clear all detected drives. In this case, you must have the HDD ID for the hard disk in order for ThinkPad systems. When an unprotected hard disk is added to a Hardware Password Manager registered system, the BIOS will recognize that the hard disk...
Hardware Maintenance Manual
Page 5
... 58 How to remove the hard-disk password . . . . 59 Power management 60 Screen blank mode 60 Sleep (Standby) mode 60 Hibernation mode 61 © Copyright Lenovo 2008, 2011 Symptom-to-FRU index 62 Numeric error codes 62 Error messages 66 Beep symptoms 67 No-beep symptoms 67 LCD-related symptoms 68... the serial number of the system unit 80 Retaining the UUID 80 Reading or writing the ECA information . . . 81 Removing and replacing a FRU . . . . 83 1010 Battery pack 84 1020 Serial Ultrabay Slim device or Serial Ultrabay Enhanced device 85 1030 Hard disk drive (HDD) cover, HDD, and HDD...
... 58 How to remove the hard-disk password . . . . 59 Power management 60 Screen blank mode 60 Sleep (Standby) mode 60 Hibernation mode 61 © Copyright Lenovo 2008, 2011 Symptom-to-FRU index 62 Numeric error codes 62 Error messages 66 Beep symptoms 67 No-beep symptoms 67 LCD-related symptoms 68... the serial number of the system unit 80 Retaining the UUID 80 Reading or writing the ECA information . . . 81 Removing and replacing a FRU . . . . 83 1010 Battery pack 84 1020 Serial Ultrabay Slim device or Serial Ultrabay Enhanced device 85 1030 Hard disk drive (HDD) cover, HDD, and HDD...
Hardware Maintenance Manual
Page 16
... the LCD gets into your eyes or on after FRU replacement, make sure all screws, springs, and other small parts are in place and are present after washing. 8 ThinkPad T400 and R400 Hardware Maintenance Manual DANGER The battery pack contains small amounts of the battery. Do not disassemble it, throw it into fire or water...
... the LCD gets into your eyes or on after FRU replacement, make sure all screws, springs, and other small parts are in place and are present after washing. 8 ThinkPad T400 and R400 Hardware Maintenance Manual DANGER The battery pack contains small amounts of the battery. Do not disassemble it, throw it into fire or water...
Hardware Maintenance Manual
Page 17
Safety information 9 DANGER To avoid shock, do as follows before removing it: power off the computer, unplug all power cords from electrical outlets, remove the battery pack, and disconnect any interconnecting cables. DANGER Unless hot swap is allowed for the FRU being replaced, do not remove the plastic cover that protects the lower part of the inverter card. DANGER Though the main batteries have low voltage, a shorted or grounded battery can produce enough current to burn personnel or combustible materials.
Safety information 9 DANGER To avoid shock, do as follows before removing it: power off the computer, unplug all power cords from electrical outlets, remove the battery pack, and disconnect any interconnecting cables. DANGER Unless hot swap is allowed for the FRU being replaced, do not remove the plastic cover that protects the lower part of the inverter card. DANGER Though the main batteries have low voltage, a shorted or grounded battery can produce enough current to burn personnel or combustible materials.
Hardware Maintenance Manual
Page 58
... Enter to enter the BIOS Setup Utility. 4. Diagnostics --> Systemboard 3. Power Diagnostics --> ThinkPad Devices --> AC Adapter, Battery 1 (Battery2) LCD unit 1. In this test. PC Card slot ExpressCard slot Diagnostics --> Systemboard --> PCMCIA 1. Using cursor keys, select HDD diagnostic program. Interactive Tests --> Diskette 50 ThinkPad T400 and R400 Hardware Maintenance Manual Diagnostics --> Video Adapter 2. If the docking...
... Enter to enter the BIOS Setup Utility. 4. Diagnostics --> Systemboard 3. Power Diagnostics --> ThinkPad Devices --> AC Adapter, Battery 1 (Battery2) LCD unit 1. In this test. PC Card slot ExpressCard slot Diagnostics --> Systemboard --> PCMCIA 1. Using cursor keys, select HDD diagnostic program. Interactive Tests --> Diskette 50 ThinkPad T400 and R400 Hardware Maintenance Manual Diagnostics --> Video Adapter 2. If the docking...
Hardware Maintenance Manual
Page 60
... that power is supplied when you turn on the computer. 5. If the voltage is used , replace the docking station or the port replicator. Check that the battery pack supplies power when you turn on , check the power cord of the AC adapter for correct...following: 1. Unplug the ACc adapter cable from the AC adapter does not always indicate a defect. 52 ThinkPad T400 and R400 Hardware Maintenance Manual Remove the battery pack. 3. Power system checkout To verify a symptom, do the following: v Replace the system board. See the following figure: 3 2 1 (20V) Pin Voltage (V dc) 1 +...
... that power is supplied when you turn on the computer. 5. If the voltage is used , replace the docking station or the port replicator. Check that the battery pack supplies power when you turn on , check the power cord of the AC adapter for correct...following: 1. Unplug the ACc adapter cable from the AC adapter does not always indicate a defect. 52 ThinkPad T400 and R400 Hardware Maintenance Manual Remove the battery pack. 3. Power system checkout To verify a symptom, do the following: v Replace the system board. See the following figure: 3 2 1 (20V) Pin Voltage (V dc) 1 +...
Hardware Maintenance Manual
Page 61
... is more than +11.0 V dc after recharging, replace the battery. 4. Remove it is correct, replace the system board. To check the battery pack, do not click), and the percentage of its capacity. If the voltage is not correct, replace the battery pack. Power off the computer. 2. This protects the battery pack from being overcharged or from the...
... is more than +11.0 V dc after recharging, replace the battery. 4. Remove it is correct, replace the system board. To check the battery pack, do not click), and the percentage of its capacity. If the voltage is not correct, replace the battery pack. Power off the computer. 2. This protects the battery pack from being overcharged or from the...
Hardware Maintenance Manual
Page 62
... the voltage is not correct, replace the backup battery. Power off the computer, and unplug the ac adapter from it. 2. v If the voltage is correct, replace the system board. See the following : 1. Measure the voltage of the backup battery. v If the backup battery discharges quickly after replacement, replace the system board. 54 ThinkPad T400 and R400 Hardware Maintenance Manual...
... the voltage is not correct, replace the backup battery. Power off the computer, and unplug the ac adapter from it. 2. v If the voltage is correct, replace the system board. See the following : 1. Measure the voltage of the backup battery. v If the backup battery discharges quickly after replacement, replace the system board. 54 ThinkPad T400 and R400 Hardware Maintenance Manual...
Hardware Maintenance Manual
Page 66
..., neither Lenovo nor Lenovo authorized service technicians provide any services to reset either the user or the master HDP, or to the hard disk drive. If it has, it can be replaced for a scheduled fee. the system administrator enters both in the BIOS Setup Utility. Remove the battery pack. ... and go to enter BIOS Setup Utility. If the Using Passphrase item is known by the service technician: 1. Select Password. 58 ThinkPad T400 and R400 Hardware Maintenance Manual For how to remove the POP, see "How to remove the battery pack, see "1060 Backup battery" on the screen;
..., neither Lenovo nor Lenovo authorized service technicians provide any services to reset either the user or the master HDP, or to the hard disk drive. If it has, it can be replaced for a scheduled fee. the system administrator enters both in the BIOS Setup Utility. Remove the battery pack. ... and go to enter BIOS Setup Utility. If the Using Passphrase item is known by the service technician: 1. Select Password. 58 ThinkPad T400 and R400 Hardware Maintenance Manual For how to remove the POP, see "How to remove the battery pack, see "1060 Backup battery" on the screen;
Hardware Maintenance Manual
Page 72
...continued) Symptom or error FRU or action, in BIOS Setup Utility. 2. Replace the backup battery and run BIOS Setup Utility to reset the time and date. 3. CPU. 2. System board. 64 ThinkPad T400 and R400 Hardware Maintenance Manual DIMM. 3. System board. 1802 Unauthorized network... card is dead. 1. Remove Mini PCI network card. 2. Charge the backup battery for more than 8 hours by connecting the ac adapter...
...continued) Symptom or error FRU or action, in BIOS Setup Utility. 2. Replace the backup battery and run BIOS Setup Utility to reset the time and date. 3. CPU. 2. System board. 64 ThinkPad T400 and R400 Hardware Maintenance Manual DIMM. 3. System board. 1802 Unauthorized network... card is dead. 1. Remove Mini PCI network card. 2. Charge the backup battery for more than 8 hours by connecting the ac adapter...
Hardware Maintenance Manual
Page 77
...the port replicator c. If any error is detected, do not replace any damaged FRU. 3. Rerun the test to verify that no error is detected, replace the FRU shown by the computer. Turn off the computer. 2. Battery pack e. If the problem does not recur, reconnect the ...defect, such as cosmic radiation, electrostatic discharge, or software errors. External diskette drive or optical drive g. If the problem remains, replace the following devices: a. Non-ThinkPad devices b. Verify that the power supply being used at a time until you find the failing FRU. 7. Verify that all of ...
...the port replicator c. If any error is detected, do not replace any damaged FRU. 3. Rerun the test to verify that no error is detected, replace the FRU shown by the computer. Turn off the computer. 2. Battery pack e. If the problem does not recur, reconnect the ...defect, such as cosmic radiation, electrostatic discharge, or software errors. External diskette drive or optical drive g. If the problem remains, replace the following devices: a. Non-ThinkPad devices b. Verify that the power supply being used at a time until you find the failing FRU. 7. Verify that all of ...
Hardware Maintenance Manual
Page 91
... 6405959). © Copyright Lenovo 2008, 2009 83 To put the new FRU in place, reverse the removal procedure and follow any notes that all power cords from electrical outlets, remove the battery pack, and then disconnect any interconnecting cables. Attention: After replacing a FRU, do not turn... on the computer until you have been trained and certified. Verify this by the arrow in the drawing. 7. Removing and replacing a FRU This chapter presents...
... 6405959). © Copyright Lenovo 2008, 2009 83 To put the new FRU in place, reverse the removal procedure and follow any notes that all power cords from electrical outlets, remove the battery pack, and then disconnect any interconnecting cables. Attention: After replacing a FRU, do not turn... on the computer until you have been trained and certified. Verify this by the arrow in the drawing. 7. Removing and replacing a FRU This chapter presents...
Hardware Maintenance Manual
Page 92
... parts list for replacing a battery pack: ThinkVantage Toolbox (in Windows 7) and Lenovo System Toolbox (in the direction shown by arrow 3. 1 2 3 When installing: Install the battery pack along the slide rails of battery pack Unlock the battery release lever 1 . Then make sure that a physically damaged battery pack is not installed in the locked position. 84 ThinkPad T400 and R400 Hardware...
... parts list for replacing a battery pack: ThinkVantage Toolbox (in Windows 7) and Lenovo System Toolbox (in the direction shown by arrow 3. 1 2 3 When installing: Install the battery pack along the slide rails of battery pack Unlock the battery release lever 1 . Then make sure that a physically damaged battery pack is not installed in the locked position. 84 ThinkPad T400 and R400 Hardware...
Hardware Maintenance Manual
Page 93
... to release the device from the bay. 1 2 3 Removing and replacing a FRU 85 Removal steps of the following devices: v Ultrabay Plus devices v Ultrabay 2000 devices Table 10. 1020 Serial Ultrabay Slim device or Serial Ultrabay Enhanced device For access, remove this FRU: v "1010 Battery pack" on page 84 Note: Serial Ultrabay Slim does...
... to release the device from the bay. 1 2 3 Removing and replacing a FRU 85 Removal steps of the following devices: v Ultrabay Plus devices v Ultrabay 2000 devices Table 10. 1020 Serial Ultrabay Slim device or Serial Ultrabay Enhanced device For access, remove this FRU: v "1010 Battery pack" on page 84 Note: Serial Ultrabay Slim does...
Hardware Maintenance Manual
Page 96
...-coated (4) Color Black Torque 0.167 Nm (1.7 kgfcm) Color Black Torque 0.167 Nm (1.7 kgfcm) 88 ThinkPad T400 and R400 Hardware Maintenance Manual If the fingerprint reader has any defects, you can replace it by the procedures given in order: v "1010 Battery pack" on page 84 Note: In models with or without a fingerprint reader. 1040 Palm...
...-coated (4) Color Black Torque 0.167 Nm (1.7 kgfcm) Color Black Torque 0.167 Nm (1.7 kgfcm) 88 ThinkPad T400 and R400 Hardware Maintenance Manual If the fingerprint reader has any defects, you can replace it by the procedures given in order: v "1010 Battery pack" on page 84 Note: In models with or without a fingerprint reader. 1040 Palm...
Hardware Maintenance Manual
Page 99
Press the DIMM firmly, and pivot it until it is used on page 88 Table 13. 1050 DIMM For access, remove these FRUs in order: v "1010 Battery pack" on page 84 v "1040 Palm rest or palm rest with fingerprint reader" on the computer you are servicing, the card must be installed in SLOT-0 ( a ), but not in SLOT-1 ( b ). 1 b 2 a 1 When installing: Insert the notched end of dimm Note: If only one DIMM is firmly fixed in the slot and does not move easily. Removing and replacing a FRU 91 Make sure that it snaps into the socket. Removal steps of the DIMM into the place.
Press the DIMM firmly, and pivot it until it is used on page 88 Table 13. 1050 DIMM For access, remove these FRUs in order: v "1010 Battery pack" on page 84 v "1040 Palm rest or palm rest with fingerprint reader" on the computer you are servicing, the card must be installed in SLOT-0 ( a ), but not in SLOT-1 ( b ). 1 b 2 a 1 When installing: Insert the notched end of dimm Note: If only one DIMM is firmly fixed in the slot and does not move easily. Removing and replacing a FRU 91 Make sure that it snaps into the socket. Removal steps of the DIMM into the place.
Hardware Maintenance Manual
Page 101
Removal steps of keyboard 1 For T400 Step Icon 1 For R400 Step Icon 1 Screw (quantity) M2 × 14 mm, flat-head, nylon-coated (1) Screw (quantity) M2 × 17 mm, flat-head, nylon-coated (1) Color Black Torque 0.167 Nm (1.7 kgfcm) Color Black Torque 0.167 Nm (1.7 kgfcm) Lift the keyboard a little in order: v "1010 Battery pack" on page 84 v "1040 Palm rest or palm rest with fingerprint reader" on page 88 Table 15. 1070 Keyboard For access, remove these FRUs in the direction shown by arrow 2 , and then detach the connector 3 . 2 3 Removing and replacing a FRU 93
Removal steps of keyboard 1 For T400 Step Icon 1 For R400 Step Icon 1 Screw (quantity) M2 × 14 mm, flat-head, nylon-coated (1) Screw (quantity) M2 × 17 mm, flat-head, nylon-coated (1) Color Black Torque 0.167 Nm (1.7 kgfcm) Color Black Torque 0.167 Nm (1.7 kgfcm) Lift the keyboard a little in order: v "1010 Battery pack" on page 84 v "1040 Palm rest or palm rest with fingerprint reader" on page 88 Table 15. 1070 Keyboard For access, remove these FRUs in the direction shown by arrow 2 , and then detach the connector 3 . 2 3 Removing and replacing a FRU 93
Hardware Maintenance Manual
Page 103
... 16. 1080 Modem daughter card (MDC-3.0) For access, remove these FRUs in the direction shown by pulling the tab with your fingers in order: v "1010 Battery pack" on page 84 v "1040 Palm rest or palm rest with fingerprint reader" on page 88 v "1070 Keyboard" on the system board. 1 2 1 Step 1 Screw (quantity...
... 16. 1080 Modem daughter card (MDC-3.0) For access, remove these FRUs in the direction shown by pulling the tab with your fingers in order: v "1010 Battery pack" on page 84 v "1040 Palm rest or palm rest with fingerprint reader" on page 88 v "1070 Keyboard" on the system board. 1 2 1 Step 1 Screw (quantity...
Hardware Maintenance Manual
Page 105
... models might have two antenna cables in direction of PCI Express Mini Card for wireless LAN/WiMAX For access, remove these FRUs in order: v "1010 Battery pack" on page 93 Table 17. Removal steps of the arrow. 1090 PCI Express Mini Card for wireless LAN/WiMAX Full size PCI Express Mini... fingers and gently unplug them in step 1 . 2 2 1 Step 2 Screw (quantity) M2 × 3 mm, small-head, nylon-coated (2) Color Silver Torque 0.167 Nm (1.7 kgfcm) Removing and replacing a FRU 97
... models might have two antenna cables in direction of PCI Express Mini Card for wireless LAN/WiMAX For access, remove these FRUs in order: v "1010 Battery pack" on page 93 Table 17. Removal steps of the arrow. 1090 PCI Express Mini Card for wireless LAN/WiMAX Full size PCI Express Mini... fingers and gently unplug them in step 1 . 2 2 1 Step 2 Screw (quantity) M2 × 3 mm, small-head, nylon-coated (2) Color Silver Torque 0.167 Nm (1.7 kgfcm) Removing and replacing a FRU 97
Hardware Maintenance Manual
Page 113
Removing and replacing a FRU 105 Removal steps of SIM card slot (continued) Remove the SIM card from the battery pack slot in the direction of arrow 3 as shown in this figure. 2 3 Step 2 Screw (quantity) M2 × 3.5 mm, flat-head, nylon-coated (1) Color Black Torque 0.167 Nm (1.7 kgfcm) When installing: Make sure the connector 3 is attached firmly. Table 20.
Removing and replacing a FRU 105 Removal steps of SIM card slot (continued) Remove the SIM card from the battery pack slot in the direction of arrow 3 as shown in this figure. 2 3 Step 2 Screw (quantity) M2 × 3.5 mm, flat-head, nylon-coated (1) Color Black Torque 0.167 Nm (1.7 kgfcm) When installing: Make sure the connector 3 is attached firmly. Table 20.