Owners Manual
Page 3
Safety Rules PLASMA Overview Safety & Handling Regulations Troubleshooting 1. Do not exceed Higher voltage than is recommended that you should be carried by two people. 6. Be careful of screws .... 3. Check the appearance of defective condition and history. Check details of Panel and boards. 2. Approximately 10 minute pre-run time is required before Requesting MODULE Repair 1. Plasma Display Panel Troubleshooting - 2007 3 Be cautious of electric shock from the PDP module since the PDP module uses high voltage, and it is required for...
Safety Rules PLASMA Overview Safety & Handling Regulations Troubleshooting 1. Do not exceed Higher voltage than is recommended that you should be carried by two people. 6. Be careful of screws .... 3. Check the appearance of defective condition and history. Check details of Panel and boards. 2. Approximately 10 minute pre-run time is required before Requesting MODULE Repair 1. Plasma Display Panel Troubleshooting - 2007 3 Be cautious of electric shock from the PDP module since the PDP module uses high voltage, and it is required for...
Owners Manual
Page 56
Make sure the Ribbon Cable is securely installed Attached particle Plasma Display Panel Troubleshooting - 2007 56 If 1 vertical line can not be resolved by this, then the defect can not be repaired and the PDP will need to be replaced. Vertical Line Troubleshooting Disconnect TCP, Check for a possible particle, if found remove with compressed air or soft fabric.
Make sure the Ribbon Cable is securely installed Attached particle Plasma Display Panel Troubleshooting - 2007 56 If 1 vertical line can not be resolved by this, then the defect can not be repaired and the PDP will need to be replaced. Vertical Line Troubleshooting Disconnect TCP, Check for a possible particle, if found remove with compressed air or soft fabric.
Owners Manual
Page 57
Root cause of TCP with X ray analyzer > < Failure viewed with microscope > Plasma Display Panel Troubleshooting - 2007 < metal particle between the electrode > 57 Troubleshooting The defect can be repaired if the vertical line is ESD or Surge. < Structure of TCP IC failure is caused by TCP IC failure. Control Board : If the buffer IC has failed, there can not be vertical lines.
Root cause of TCP with X ray analyzer > < Failure viewed with microscope > Plasma Display Panel Troubleshooting - 2007 < metal particle between the electrode > 57 Troubleshooting The defect can be repaired if the vertical line is ESD or Surge. < Structure of TCP IC failure is caused by TCP IC failure. Control Board : If the buffer IC has failed, there can not be vertical lines.