Page 2
...is provided in connection with Intel® products. Except as the property of Intel Corporation or its subsidiaries in the United States and other countries. * Other names and brands may be held responsible if components fail or the server board does not operate correctly when... or otherwise, to meet the intended thermal requirements of their specific application and environmental conditions. Copyright © 2007-2008, Intel Corporation. Intel® server boards contain a number of high-density VLSI and power delivery components that chooses not to use in any medical, life saving...
...is provided in connection with Intel® products. Except as the property of Intel Corporation or its subsidiaries in the United States and other countries. * Other names and brands may be held responsible if components fail or the server board does not operate correctly when... or otherwise, to meet the intended thermal requirements of their specific application and environmental conditions. Copyright © 2007-2008, Intel Corporation. Intel® server boards contain a number of high-density VLSI and power delivery components that chooses not to use in any medical, life saving...
User Guide
Page 3
... toute instruction. Vea Intel® Server Boards and Server Chassis Safety Information en http://support.intel.com/support/motherboards/server/sb/cs-010770.htm. See also Intel® Server Boards and Server Chassis Safety Information at http://support.intel.com/support/motherboards/server/sb/cs-010770.htm. Intel® Compute Module MFS5000SI User Guide iii Beachten Sie hierzu auch die Intel® Server Boards and Server Chassis Safety Information unter...
... toute instruction. Vea Intel® Server Boards and Server Chassis Safety Information en http://support.intel.com/support/motherboards/server/sb/cs-010770.htm. See also Intel® Server Boards and Server Chassis Safety Information at http://support.intel.com/support/motherboards/server/sb/cs-010770.htm. Intel® Compute Module MFS5000SI User Guide iii Beachten Sie hierzu auch die Intel® Server Boards and Server Chassis Safety Information unter...
User Guide
Page 4
..., devices and cables: Hazardous electrical conditions may bend or break the pins on your server product, whether you are using needle nosed pliers to remove or install a jumper;... before you open the chassis, add, or remove any unpainted metal surface) on the board. Turn off the system AC power. Installing or removing jumpers: A jumper is not... protect internal components and for proper cooling and airflow, the compute module should maintain or configure the system. iv Intel® Compute Module MFS5000SI User Guide System power on power, telephone, and communication cables...
..., devices and cables: Hazardous electrical conditions may bend or break the pins on your server product, whether you are using needle nosed pliers to remove or install a jumper;... before you open the chassis, add, or remove any unpainted metal surface) on the board. Turn off the system AC power. Installing or removing jumpers: A jumper is not... protect internal components and for proper cooling and airflow, the compute module should maintain or configure the system. iv Intel® Compute Module MFS5000SI User Guide System power on power, telephone, and communication cables...
User Guide
Page 11
...Card 36 Figure 40. Securing Mezzanine Card to Standoffs 35 Figure 39. CMOS Battery Location 40 Intel® Compute Module MFS5000SI User Guide xi Front Panel Connectors and Indicators 5 Figure 6. Removing Socket Protective Cover 14 ...Intel® Compute Module MFS5000SI 1 Figure 2. Removing Top Cover 9 Figure 7. Lifting Processor Socket Handle 12 Figure 10. Removing Protective Shipping Cover 13 Figure 12. Removing Second Processor Air Baffle 16 Figure 17. Re-installing Heatsink 22 Figure 27. Reinstalling Processor Air Duct 31 Figure 35. Removing Screws from Server Board...
...Card 36 Figure 40. Securing Mezzanine Card to Standoffs 35 Figure 39. CMOS Battery Location 40 Intel® Compute Module MFS5000SI User Guide xi Front Panel Connectors and Indicators 5 Figure 6. Removing Socket Protective Cover 14 ...Intel® Compute Module MFS5000SI 1 Figure 2. Removing Top Cover 9 Figure 7. Lifting Processor Socket Handle 12 Figure 10. Removing Protective Shipping Cover 13 Figure 12. Removing Second Processor Air Baffle 16 Figure 17. Re-installing Heatsink 22 Figure 27. Reinstalling Processor Air Duct 31 Figure 35. Removing Screws from Server Board...
User Guide
Page 13
1 Compute Module Features This chapter briefly describes the main features of the Intel® Compute Module MFS5000SI, as well as provides illustrations showing the location of important components and connections on the compute module. Server Board Intel® Compute Module MFS5000SI User Guide 1 The Intel® Compute Module MFS5000SI is shown in the following pictures. Figure 1. Intel® Compute Module MFS5000SI Figure 2.
1 Compute Module Features This chapter briefly describes the main features of the Intel® Compute Module MFS5000SI, as well as provides illustrations showing the location of important components and connections on the compute module. Server Board Intel® Compute Module MFS5000SI User Guide 1 The Intel® Compute Module MFS5000SI is shown in the following pictures. Figure 1. Intel® Compute Module MFS5000SI Figure 2.
User Guide
Page 14
... mirroring Intel® 5000P chipset, consisting of the server board. Table 1. Compute Module Features Feature Processors Memory Chipset Peripheral Interfaces Video Hard Drive LAN Trusted Computing Description Support for up to two Dual-Core Intel®... Xeon® processors 5000 sequence Support for up to the chassis I/O mezzanine card ATI* ES1000 controller with 16MB onboard memory LSI* 1064e SAS controller Intel® 8256EB dual port controller Trusted Platform Module, version 1.2 2 Intel® Compute Module MFS5000SI...
... mirroring Intel® 5000P chipset, consisting of the server board. Table 1. Compute Module Features Feature Processors Memory Chipset Peripheral Interfaces Video Hard Drive LAN Trusted Computing Description Support for up to two Dual-Core Intel®... Xeon® processors 5000 sequence Support for up to the chassis I/O mezzanine card ATI* ES1000 controller with 16MB onboard memory LSI* 1064e SAS controller Intel® 8256EB dual port controller Trusted Platform Module, version 1.2 2 Intel® Compute Module MFS5000SI...
User Guide
Page 36
...mirroring and memory on -line sparing. See the Intel® Compute Module MFS5000SI Technical Product Specification for additional information regarding the memory sub-system. 24 Intel® Compute Module MFS5000SI User Guide Installing and Removing Memory Modules Supported Memory The server board provides support for eight DDR2-667 fully-buffered DIMM...the primary and the mirrored copy of all DIMMs with DDR2 DRAM technology. • Use only DDR2-667 stacked FB-DIMM modules. and channel D consists of slots C1 and C2; DIMMs must meet the following requirements: • Use only fully-...
...mirroring and memory on -line sparing. See the Intel® Compute Module MFS5000SI Technical Product Specification for additional information regarding the memory sub-system. 24 Intel® Compute Module MFS5000SI User Guide Installing and Removing Memory Modules Supported Memory The server board provides support for eight DDR2-667 fully-buffered DIMM...the primary and the mirrored copy of all DIMMs with DDR2 DRAM technology. • Use only DDR2-667 stacked FB-DIMM modules. and channel D consists of slots C1 and C2; DIMMs must meet the following requirements: • Use only fully-...
User Guide
Page 44
... 35. Installing and Removing Mezzanine Card Installing the Mezzanine Card 1. If the compute module is installed in the appendices. 2. Holding the mezzanine card by its edges, remove it from Server Board AF002456 32 Intel® Compute Module MFS5000SI User Guide Locate the mezzanine card socket on the server board. 6. Removing Screws from the packaging. Observe the safety and ESD information...
... 35. Installing and Removing Mezzanine Card Installing the Mezzanine Card 1. If the compute module is installed in the appendices. 2. Holding the mezzanine card by its edges, remove it from Server Board AF002456 32 Intel® Compute Module MFS5000SI User Guide Locate the mezzanine card socket on the server board. 6. Removing Screws from the packaging. Observe the safety and ESD information...
User Guide
Page 46
Installing Mezzanine Card AF002407 34 Intel® Compute Module MFS5000SI User Guide Position the mezzanine card above the mezzanine card socket and align the four screw holes with the standoffs taking care to position the connector housing on the mezzanine card with the connector on the standoff supports. 1 I/O 2 1 2 ID Figure 37. Carefully press the mezzanine card into place until it is fully seated in the socket and resting on the server board. 8.
Installing Mezzanine Card AF002407 34 Intel® Compute Module MFS5000SI User Guide Position the mezzanine card above the mezzanine card socket and align the four screw holes with the standoffs taking care to position the connector housing on the mezzanine card with the connector on the standoff supports. 1 I/O 2 1 2 ID Figure 37. Carefully press the mezzanine card into place until it is fully seated in the socket and resting on the server board. 8.
User Guide
Page 51
..., see "Removing a Compute Module from the Server System" on the server board powers the RTC for up to 10 years in the absence of power. When the battery starts to manufacturer's instructions. Udskiftning må kun ske med batteri af samme fabrikat og type. Ved utskifting benyttes kun batteri som anbefalt av apparatfabrikanten. Intel® Compute Module MFS5000SI User Guide...
..., see "Removing a Compute Module from the Server System" on the server board powers the RTC for up to 10 years in the absence of power. When the battery starts to manufacturer's instructions. Udskiftning må kun ske med batteri af samme fabrikat og type. Ved utskifting benyttes kun batteri som anbefalt av apparatfabrikanten. Intel® Compute Module MFS5000SI User Guide...
User Guide
Page 53
... settings on the server board correct? • Are the configuration settings defined in their sockets on . Before performing extensive troubleshooting steps, ensure that the system BIOS and BMC firmware code, and device drivers are up to all installed components and the installed operating system listed in troubleshooting the Intel® Compute Module MFS5000SI. try resetting your...
... settings on the server board correct? • Are the configuration settings defined in their sockets on . Before performing extensive troubleshooting steps, ensure that the system BIOS and BMC firmware code, and device drivers are up to all installed components and the installed operating system listed in troubleshooting the Intel® Compute Module MFS5000SI. try resetting your...
User Guide
Page 73
...must adhere to disconnect AC power Please recycle battery Intel® Compute Module MFS5000SI User Guide 61 D Safety Information English Server Safety Information This document applies to ensure and ...Intel® server product. Indicates hot components or surfaces. CAUTION WARNING Indicates the presence of a conflict between the information in this guide and the assembly instructions in injury. Safety Warnings and Cautions To avoid personal injury or property damage, before installing or maintaining your server manuals to Intel® server boards, Intel® server...
...must adhere to disconnect AC power Please recycle battery Intel® Compute Module MFS5000SI User Guide 61 D Safety Information English Server Safety Information This document applies to ensure and ...Intel® server product. Indicates hot components or surfaces. CAUTION WARNING Indicates the presence of a conflict between the information in this guide and the assembly instructions in injury. Safety Warnings and Cautions To avoid personal injury or property damage, before installing or maintaining your server manuals to Intel® server boards, Intel® server...
User Guide
Page 76
...ESD can be careful when removing or installing the hot-plug component(s). Use a 64 Intel® Compute Module MFS5000SI User Guide on a grounded, static free surface. Always handle boards carefully. Caution: If the server has been running, any installed processor(s) and heat sink(s) may be labeled as controlling...only one is supplied with hot component(s) during a hot-plug installation, be extremely sensitive to the server(s). If one piece of equipment from the server, place the board component side up , with original screws or fasteners. • Do not access the inside of...
...ESD can be careful when removing or installing the hot-plug component(s). Use a 64 Intel® Compute Module MFS5000SI User Guide on a grounded, static free surface. Always handle boards carefully. Caution: If the server has been running, any installed processor(s) and heat sink(s) may be labeled as controlling...only one is supplied with hot component(s) during a hot-plug installation, be extremely sensitive to the server(s). If one piece of equipment from the server, place the board component side up , with original screws or fasteners. • Do not access the inside of...