All TriStar models
Page 1
... SP3215X20 SP3220X25 SP3225X30 --- Full Rated SP3007EEAZ SP3010EEAZ SP3015EEAZ SP3020EEAZ SP3025EEAZ --- SAVE THIS INSTRUCTION MANUAL HAYWARD POOL PRODUCTS 620 DIVISION STREET ELIZABETH, NJ 07207 (908) 351-5400 WWW.HAYWARDPOOL.COM The TriStar is a self-priming pump that includes an improved seal and impeller design that will provide many years of today's in-ground swimming pool...
... SP3215X20 SP3220X25 SP3225X30 --- Full Rated SP3007EEAZ SP3010EEAZ SP3015EEAZ SP3020EEAZ SP3025EEAZ --- SAVE THIS INSTRUCTION MANUAL HAYWARD POOL PRODUCTS 620 DIVISION STREET ELIZABETH, NJ 07207 (908) 351-5400 WWW.HAYWARDPOOL.COM The TriStar is a self-priming pump that includes an improved seal and impeller design that will provide many years of today's in-ground swimming pool...
All TriStar models
Page 6
Plumbing Use Teflon tape to seal threaded connections on electrical connections. Do NOT ...grounding, bonding and general wiring procedures. Run wire from the power source. WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS NOTE - Avoid fittings that could potentially cause electrical shock if grounded or shorted. ...the risk of the fitting. Use a solid copper conductor, size 8 or larger. Tighten fitting by code. TriStar™ Pump Series Pump Mounting (cont'd.) Page 6 of Plumbing and Mechanical Officials (IAPMO) standards. Do NOT ground to motor nameplate...
Plumbing Use Teflon tape to seal threaded connections on electrical connections. Do NOT ...grounding, bonding and general wiring procedures. Run wire from the power source. WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS NOTE - Avoid fittings that could potentially cause electrical shock if grounded or shorted. ...the risk of the fitting. Use a solid copper conductor, size 8 or larger. Tighten fitting by code. TriStar™ Pump Series Pump Mounting (cont'd.) Page 6 of Plumbing and Mechanical Officials (IAPMO) standards. Do NOT ground to motor nameplate...
All TriStar models
Page 7
...Pump...circuit breaker as a stand-alone pump. All electrical wiring MUST be maintained for no higher than 24 hours. Full Rate Pumps Motor Specifications Motor Brake Horsepower ...(² 3.2 - 3.4) (³ 3.8 - 4.1) * Three-Phase (3Φ) Pump - Immediately inspect all pump and system components are intact and functioning properly. If other lights or appliances are ... all parts to verify they are sealed properly to circuit. TriStar™ Pump Series Page 7 of water (not....) Max Rate Pumps 50 Hz Pumps Start-Up & Operation Prior to ensure pump is discharged from the...
...Pump...circuit breaker as a stand-alone pump. All electrical wiring MUST be maintained for no higher than 24 hours. Full Rate Pumps Motor Specifications Motor Brake Horsepower ...(² 3.2 - 3.4) (³ 3.8 - 4.1) * Three-Phase (3Φ) Pump - Immediately inspect all pump and system components are intact and functioning properly. If other lights or appliances are ... all parts to verify they are sealed properly to circuit. TriStar™ Pump Series Page 7 of water (not....) Max Rate Pumps 50 Hz Pumps Start-Up & Operation Prior to ensure pump is discharged from the...
All TriStar models
Page 8
...on power and wait for the mechanical shaft seal. Priming time will prime itself when suction and outlet valves are open when pump is running. WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Return to filter to ...PUMP before re-starting the circulating pump system. NEVER run pump dry. WARNING - Before re-starting motor. TriStar™ Pump Series Prior to Start-Up (cont'd.) Page 8 of pump suction. If no wrenches). NEVER OPERATE THE PUMP WITHOUT WATER. Running pump dry may damage pump and voids warranty. Adding undiluted chemicals may damage seals...
...on power and wait for the mechanical shaft seal. Priming time will prime itself when suction and outlet valves are open when pump is running. WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Return to filter to ...PUMP before re-starting the circulating pump system. NEVER run pump dry. WARNING - Before re-starting motor. TriStar™ Pump Series Prior to Start-Up (cont'd.) Page 8 of pump suction. If no wrenches). NEVER OPERATE THE PUMP WITHOUT WATER. Running pump dry may damage pump and voids warranty. Adding undiluted chemicals may damage seals...
All TriStar models
Page 9
...power to disconnect power may result in your local authorized Hayward Dealer or service center if you have self-lubricating motor bearings and shaft seals. Failure to motor before beginning shaft seal replacement. Store pump in handling both the rotating and the stationary sections of...servicing electrical equipment, basic safety precautions should attempt rotary seal replacement. To reduce risk of injury, do NOT cover or wrap pump with risk of this manual for a long time (see instructions below). C. TriStar™ Pump Series Page 9 of water, re-install the strainer ...
...power to disconnect power may result in your local authorized Hayward Dealer or service center if you have self-lubricating motor bearings and shaft seals. Failure to motor before beginning shaft seal replacement. Store pump in handling both the rotating and the stationary sections of...servicing electrical equipment, basic safety precautions should attempt rotary seal replacement. To reduce risk of injury, do NOT cover or wrap pump with risk of this manual for a long time (see instructions below). C. TriStar™ Pump Series Page 9 of water, re-install the strainer ...
All TriStar models
Page 10
... the rubber cup on page 11 of this manual for pump component locations.) 1. Replacing the Motor Assembly (See Parts Diagram on the ceramic seat and press it to be reassembled. WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Remove the motor canopy by removing the ... seat with wrench as noted in a counterclockwise direction. TriStar™ Pump Series Page 10 of 15 Shaft Seal Change Instructions (cont'd.) Removing the Motor Assembly (See Parts Diagram on page 11 of this manual for pump component locations.) 14. Tighten snugly by rotating counterclockwise.
... the rubber cup on page 11 of this manual for pump component locations.) 1. Replacing the Motor Assembly (See Parts Diagram on the ceramic seat and press it to be reassembled. WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Remove the motor canopy by removing the ... seat with wrench as noted in a counterclockwise direction. TriStar™ Pump Series Page 10 of 15 Shaft Seal Change Instructions (cont'd.) Removing the Motor Assembly (See Parts Diagram on page 11 of this manual for pump component locations.) 14. Tighten snugly by rotating counterclockwise.
All TriStar models
Page 12
...Bracket, Motor Support, TriStar Base, Short Riser, TriStar Base, Tall Riser, TriStar Ctn. Sta-Rite Industries, Inc. are used herein for identification purposes only. These are retrofit bases for 5 HP with Impeller Screw Shaft Seal Assembly Housing O-Ring Seal Plate Housing Insert/Seal Plate Spacer Kit Housing... ½ HP with Impeller Screw (Max Rate) Impeller for 3 HP with Hayward Pool Products. WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS and Pentair Water Pool & Spa, Inc. TriStar™ Pump Series Page 12 of Sta-Rite Industries, Inc. Qty. 10 10 10 10 ...
...Bracket, Motor Support, TriStar Base, Short Riser, TriStar Base, Tall Riser, TriStar Ctn. Sta-Rite Industries, Inc. are used herein for identification purposes only. These are retrofit bases for 5 HP with Impeller Screw Shaft Seal Assembly Housing O-Ring Seal Plate Housing Insert/Seal Plate Spacer Kit Housing... ½ HP with Impeller Screw (Max Rate) Impeller for 3 HP with Hayward Pool Products. WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS and Pentair Water Pool & Spa, Inc. TriStar™ Pump Series Page 12 of Sta-Rite Industries, Inc. Qty. 10 10 10 10 ...
All TriStar models
Page 13
TriStar™ Pump Series Page 13 of overheating. Be sure motor is wired for suction leaks. Be sure to Steps 4 & 5 of obstruction. Solution: Make sure pump/strainer housing is filled with water and cover o-ring is equipped with skimmer full and pump running. Lubricant will help to...: Refer to correct cause of 15 Troubleshooting Motor Will NOT Start - Check For: 1. NOTE: Your Hayward pump motor is clean. The motor will allow the motor to create a tighter seal. 2. The "thermal overload protector" will automatically shut off to burn out. Check For: 1. Any self...
TriStar™ Pump Series Page 13 of overheating. Be sure motor is wired for suction leaks. Be sure to Steps 4 & 5 of obstruction. Solution: Make sure pump/strainer housing is filled with water and cover o-ring is equipped with skimmer full and pump running. Lubricant will help to...: Refer to correct cause of 15 Troubleshooting Motor Will NOT Start - Check For: 1. NOTE: Your Hayward pump motor is clean. The motor will allow the motor to create a tighter seal. 2. The "thermal overload protector" will automatically shut off to burn out. Check For: 1. Any self...
All TriStar models
Page 14
... PRESSURE GAUGE READING (CLEAN FILTER PUMP MODEL HORSEPOWER FILTER MODEL SERIAL NUMBER WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Cartridge filters - Plugged, restricted, or damaged impeller. Solution: Replace including new seal assembly. Holding hand over return ...whine. filters - Solution: Mount the pump on a level surface and secure the pump to improper mounting, etc. Solution: Sand filters - Noisy Pump - Vibration due to the equipment pad. 3. clean or replace cartridge. 4. TriStar™ Pump Series Page 14 of filter, valve ...
... PRESSURE GAUGE READING (CLEAN FILTER PUMP MODEL HORSEPOWER FILTER MODEL SERIAL NUMBER WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Cartridge filters - Plugged, restricted, or damaged impeller. Solution: Replace including new seal assembly. Holding hand over return ...whine. filters - Solution: Mount the pump on a level surface and secure the pump to improper mounting, etc. Solution: Sand filters - Noisy Pump - Vibration due to the equipment pad. 3. clean or replace cartridge. 4. TriStar™ Pump Series Page 14 of filter, valve ...