Model: ALL
Page 1
...pools. Corporate Headquarters: 620 Division Street Elizabeth, NJ 07207 U.S.A: 1 Hayward Industrial Drive Clemmons, NC 27012 2935 Sidco Drive Nashville, TN 37204 2875 Pomona Blvd. CAUTION - We highly recommend a qualified professional install and service this manual carefully and completely. C OWNER'S MANUAL INSTALLATION, OPERATION, & PARTS Power-Flo LX™ / Power-Flo II™ Pump Series The Hayward® Power-Flo LX™ and Power-Flo II™ Pump Series... calls, read this product. SAVE THIS INSTRUCTION MANUAL HAYWARD POOL PRODUCTS, INC. ISPF SERIES Rev.
...pools. Corporate Headquarters: 620 Division Street Elizabeth, NJ 07207 U.S.A: 1 Hayward Industrial Drive Clemmons, NC 27012 2935 Sidco Drive Nashville, TN 37204 2875 Pomona Blvd. CAUTION - We highly recommend a qualified professional install and service this manual carefully and completely. C OWNER'S MANUAL INSTALLATION, OPERATION, & PARTS Power-Flo LX™ / Power-Flo II™ Pump Series The Hayward® Power-Flo LX™ and Power-Flo II™ Pump Series... calls, read this product. SAVE THIS INSTRUCTION MANUAL HAYWARD POOL PRODUCTS, INC. ISPF SERIES Rev.
Model: ALL
Page 2
...GOOD CONDITION AND REPLACE IF MISSING OR DAMAGED. The ANSI/NSPI 4 Standard (above -ground swimming pools and may result in injury. The Power-Flo LX™ / Power-Flo II™ Pump Series' are intended for outdoor use with hot tubs and spas if so marked. It requires free ... of air for storage. WARNING - A storable pool is constructed in or on permanently installed above -ground and on-ground pools) advises that it rains. Use a solid copper conductor, size or larger. Power-Flo LX™ / Power-Flo II™ Pump Series PRODUCT REGISTRATION (Retain For Your Records) DATE OF...
...GOOD CONDITION AND REPLACE IF MISSING OR DAMAGED. The ANSI/NSPI 4 Standard (above -ground swimming pools and may result in injury. The Power-Flo LX™ / Power-Flo II™ Pump Series' are intended for outdoor use with hot tubs and spas if so marked. It requires free ... of air for storage. WARNING - A storable pool is constructed in or on permanently installed above -ground and on-ground pools) advises that it rains. Use a solid copper conductor, size or larger. Power-Flo LX™ / Power-Flo II™ Pump Series PRODUCT REGISTRATION (Retain For Your Records) DATE OF...
Model: ALL
Page 3
...and/or property damage. Do NOT connect to electric supply. WARNING - Locate cord to bleed air from your pump is intended for pools and spas require two (2) functioning suction outlets at more than 30 PSI. Failure to a grounding type receptacle ... an extension cord to connect unit to a high-pressure system such as a municipal water main. Pumps, filters, and other equipment. CAUTION - Power-Flo LX™ / Power-Flo II™ Pump Series __________ ____________ NOTE: The National Electrical Code (NEC) permits use of the pool or spa. Suction Entrapment Hazard.
...and/or property damage. Do NOT connect to electric supply. WARNING - Locate cord to bleed air from your pump is intended for pools and spas require two (2) functioning suction outlets at more than 30 PSI. Failure to a grounding type receptacle ... an extension cord to connect unit to a high-pressure system such as a municipal water main. Pumps, filters, and other equipment. CAUTION - Power-Flo LX™ / Power-Flo II™ Pump Series __________ ____________ NOTE: The National Electrical Code (NEC) permits use of the pool or spa. Suction Entrapment Hazard.
Model: ALL
Page 4
... with one to prevent leakage. Increase size if a long run pipe AWAY from pump. To avoid pump strain, support suction and outlet independently. Place supports near pump. Power-Flo LX™ / Power-Flo II™ Pump Series Installation Instructions Pump Location The Power-Flo LX™ pump MUST be installed below the pool water line (see Figure to two additional layers of Teflon tape, and re...
... with one to prevent leakage. Increase size if a long run pipe AWAY from pump. To avoid pump strain, support suction and outlet independently. Place supports near pump. Power-Flo LX™ / Power-Flo II™ Pump Series Installation Instructions Pump Location The Power-Flo LX™ pump MUST be installed below the pool water line (see Figure to two additional layers of Teflon tape, and re...
Model: ALL
Page 5
... to reinforcing rod or mesh. Avoid fittings that the wire size is adequate for GFCI, see manufacturer's instructions. Power-Flo LX™ / Power-Flo II™ Pump Series Installation Instructions (cont.) Fittings Fittings restrict flow. Use a non-entrapping suction fitting in circuit; If GFCI trips ...required by a qualified professional, and MUST conform to the International Association of swimming pool, spa, or hot tub. Install a Ground Fault Circuit Interrupter (GFCI) in pool or double suction (skimmer and main drain). Ground motor before working on the ...
... to reinforcing rod or mesh. Avoid fittings that the wire size is adequate for GFCI, see manufacturer's instructions. Power-Flo LX™ / Power-Flo II™ Pump Series Installation Instructions (cont.) Fittings Fittings restrict flow. Use a non-entrapping suction fitting in circuit; If GFCI trips ...required by a qualified professional, and MUST conform to the International Association of swimming pool, spa, or hot tub. Install a Ground Fault Circuit Interrupter (GFCI) in pool or double suction (skimmer and main drain). Ground motor before working on the ...
Model: ALL
Page 6
... Small children using pool MUST always have close adult supervision. turn . Priming time will prevent normal pump operation. Reset if necessary. Do NOT add chemicals to pool/spa system directly in suction and outlet pipes. 3. CAUTION - STOP PUMP before removing strainer ... cause. WARNING - If pump is higher than the pump, unscrew and remove strainer cover; fill strainer and pump with water. Clean and lubricate strainer cover O-ring with water to suction pipe level. Power-Flo LX™ / Power-Flo II™ Pump Series Installation Instructions (cont.) Electrical...
... Small children using pool MUST always have close adult supervision. turn . Priming time will prevent normal pump operation. Reset if necessary. Do NOT add chemicals to pool/spa system directly in suction and outlet pipes. 3. CAUTION - STOP PUMP before removing strainer ... cause. WARNING - If pump is higher than the pump, unscrew and remove strainer cover; fill strainer and pump with water. Clean and lubricate strainer cover O-ring with water to suction pipe level. Power-Flo LX™ / Power-Flo II™ Pump Series Installation Instructions (cont.) Electrical...
Model: ALL
Page 7
.../corrosion problems, do not permit children to follow instructions may damage plastic components in your local authorized Hayward Dealer or service center if you have any questions. Drain water level below all electrical wiring for ...Power-Flo LX™ / Power-Flo II™ Pump Series Storage/Winterization WARNING - Explosion Hazard. Gravity drain system as far as needed. 3. Disconnect pump from bottom of the filter. 2. Once the pump is non-toxic and will void the warranty. Inspect all inlets to freeze will not damage plastic system components; Refill pool...
.../corrosion problems, do not permit children to follow instructions may damage plastic components in your local authorized Hayward Dealer or service center if you have any questions. Drain water level below all electrical wiring for ...Power-Flo LX™ / Power-Flo II™ Pump Series Storage/Winterization WARNING - Explosion Hazard. Gravity drain system as far as needed. 3. Disconnect pump from bottom of the filter. 2. Once the pump is non-toxic and will void the warranty. Inspect all inlets to freeze will not damage plastic system components; Refill pool...
Model: ALL
Page 8
...the graphite and ceramic sealing surfaces. 1. Reconnect pump to correct cause of the pump housing recess. Bypass it by pressing the white ceramic seat out of overheating. NOTE: Your Hayward pump motor is secure. Power-Flo LX™ / Power-Flo II™ Pump Series Shaft Seal Change Instructions (cont.) Exercise extreme ...of the motor. 8. open -end wrench to burn out. loose connections; Foreign matter or improper handling will continue to pool. Hand-tighten the impeller in step #7. Remove the canopy or the shaft cover plate from the front of non-granulated ...
...the graphite and ceramic sealing surfaces. 1. Reconnect pump to correct cause of the pump housing recess. Bypass it by pressing the white ceramic seat out of overheating. NOTE: Your Hayward pump motor is secure. Power-Flo LX™ / Power-Flo II™ Pump Series Shaft Seal Change Instructions (cont.) Exercise extreme ...of the motor. 8. open -end wrench to burn out. loose connections; Foreign matter or improper handling will continue to pool. Hand-tighten the impeller in step #7. Remove the canopy or the shaft cover plate from the front of non-granulated ...
Model: ALL
Page 9
... suction (bubbles issuing from return fittings). Power-Flo LX™ / Power-Flo II™ Pump Series Troubleshooting (cont.) Motor Hums, But Does NOT Start - Pump Won't Prime 1. Make sure all hose clamps are tight. If pump does not develop a vacuum and pump has sufficient "priming water": i. Remove ... basket regularly. Inspect strainer cover gasket regularly and replace as necessary. Hayward pumps have 5"-6" of filter, valve partially closed (high gauge reading). No lubrication is felt, check for clogging or obstruction in pool, and unrestricted discharge return lines.
... suction (bubbles issuing from return fittings). Power-Flo LX™ / Power-Flo II™ Pump Series Troubleshooting (cont.) Motor Hums, But Does NOT Start - Pump Won't Prime 1. Make sure all hose clamps are tight. If pump does not develop a vacuum and pump has sufficient "priming water": i. Remove ... basket regularly. Inspect strainer cover gasket regularly and replace as necessary. Hayward pumps have 5"-6" of filter, valve partially closed (high gauge reading). No lubrication is felt, check for clogging or obstruction in pool, and unrestricted discharge return lines.
Model: ALL
Page 11
Power-Flo LX™ / Power-Flo II™ Pump Series HAYWARD® LIMITED WARRANTY This pump was inspected before shipment from the date of incidental or consequential damages, so the above limitation or exclusion may not apply...9633; Vinyl □ Fiberglass □ Gunite □ Above-ground Size of purchase. To original purchasers of this pump, Hayward Pool Products, Inc., 620 Division Street, Elizabeth, New Jersey, warrants its pump housing/strainer to components manufactured by the respective manufacturer will apply. warrants its products free from defects in service □...
Power-Flo LX™ / Power-Flo II™ Pump Series HAYWARD® LIMITED WARRANTY This pump was inspected before shipment from the date of incidental or consequential damages, so the above limitation or exclusion may not apply...9633; Vinyl □ Fiberglass □ Gunite □ Above-ground Size of purchase. To original purchasers of this pump, Hayward Pool Products, Inc., 620 Division Street, Elizabeth, New Jersey, warrants its pump housing/strainer to components manufactured by the respective manufacturer will apply. warrants its products free from defects in service □...