...specifically engineered for the demanding requirements of this product. Corporate Headquarters: 620 Division Street Elizabeth, NJ 07207 U.S.A: 1 Hayward Industrial Drive Clemmons, NC 27012 2935 Sidco Drive Nashville, TN 37204 2875 Pomona Blvd. To prevent potential injury and...des chênes 01150 St Vulbas France SAVE THIS INSTRUCTION MANUAL HAYWARD POOL PRODUCTS, INC. C OWNER'S MANUAL INSTALLATION, OPERATION, & PARTS Power-Flo LX™ / Power-Flo II™ Pump Series The Hayward® Power-Flo LX™ and Power-Flo II™ Pump Series are UL-Listed. ISPF SERIES Rev.
...specifically engineered for the demanding requirements of this product. Corporate Headquarters: 620 Division Street Elizabeth, NJ 07207 U.S.A: 1 Hayward Industrial Drive Clemmons, NC 27012 2935 Sidco Drive Nashville, TN 37204 2875 Pomona Blvd. To prevent potential injury and...des chênes 01150 St Vulbas France SAVE THIS INSTRUCTION MANUAL HAYWARD POOL PRODUCTS, INC. C OWNER'S MANUAL INSTALLATION, OPERATION, & PARTS Power-Flo LX™ / Power-Flo II™ Pump Series The Hayward® Power-Flo LX™ and Power-Flo II™ Pump Series are UL-Listed. ISPF SERIES Rev.
Model: ALL
Page 2
... to the pool by young children. Power-Flo LX™ / Power-Flo II™ Pump Series PRODUCT REGISTRATION (Retain For Your Records) DATE OF INSTALLATION INITIAL PRESSURE GAUGE READING (CLEAN FILTER PUMP MODEL HORSEPOWER FILTER MODEL SERIAL NUMBER IMPORTANT SAFETY INSTRUCTIONS When installing and using this product. The Power-Flo LX™ / Power-Flo II™ Pump Series' are intended for use or...
... to the pool by young children. Power-Flo LX™ / Power-Flo II™ Pump Series PRODUCT REGISTRATION (Retain For Your Records) DATE OF INSTALLATION INITIAL PRESSURE GAUGE READING (CLEAN FILTER PUMP MODEL HORSEPOWER FILTER MODEL SERIAL NUMBER IMPORTANT SAFETY INSTRUCTIONS When installing and using this product. The Power-Flo LX™ / Power-Flo II™ Pump Series' are intended for use or...
Model: ALL
Page 3
.... Suction Entrapment Hazard. WARNING - WARNING - Do NOT bury cord. Never use an extension cord to connect unit to electric supply. Pumps, filters, and other equipment. Never operate or test the filtration system at least three (3) feet apart, on two (2) walls or ..., severe injury, and death. CAUTION - If screws are lost, order replacement parts from your pump is protected by a Ground Fault Circuit Interrupter (GFCI). Power-Flo LX™ / Power-Flo II™ Pump Series __________ ____________ NOTE: The National Electrical Code (NEC) permits use provided air relief valve to...
.... Suction Entrapment Hazard. WARNING - WARNING - Do NOT bury cord. Never use an extension cord to connect unit to electric supply. Pumps, filters, and other equipment. Never operate or test the filtration system at least three (3) feet apart, on two (2) walls or ..., severe injury, and death. CAUTION - If screws are lost, order replacement parts from your pump is protected by a Ground Fault Circuit Interrupter (GFCI). Power-Flo LX™ / Power-Flo II™ Pump Series __________ ____________ NOTE: The National Electrical Code (NEC) permits use provided air relief valve to...
Model: ALL
Page 4
... components. To avoid strain left by hand and then use of the fitting. Self-priming Power-Flo II™ pumps may cause damage. Though the pump is designed for cooling. Power-Flo LX™ / Power-Flo II™ Pump Series Installation Instructions Pump Location The Power-Flo LX™ pump MUST be installed below the pool water line (see Figure to force hose connector fitting...
... components. To avoid strain left by hand and then use of the fitting. Self-priming Power-Flo II™ pumps may cause damage. Though the pump is designed for cooling. Power-Flo LX™ / Power-Flo II™ Pump Series Installation Instructions Pump Location The Power-Flo LX™ pump MUST be installed below the pool water line (see Figure to force hose connector fitting...
Model: ALL
Page 5
... connecting to electrical service ground. Voltage Voltage at full load, consult power company. If other lights or appliances are also on the same circuit, be performed by code. Power-Flo LX™ / Power-Flo II™ Pump Series Installation Instructions (cont.) Fittings Fittings restrict flow. Pool and spa...Use green ground terminal provided under motor canopy or access place; use the fewest possible fittings. Run wire from the power source. Wiring Pump MUST be more than 10% above or below motor name plate rated voltage, or motor may overheat, causing overload tripping...
... connecting to electrical service ground. Voltage Voltage at full load, consult power company. If other lights or appliances are also on the same circuit, be performed by code. Power-Flo LX™ / Power-Flo II™ Pump Series Installation Instructions (cont.) Fittings Fittings restrict flow. Pool and spa...Use green ground terminal provided under motor canopy or access place; use the fewest possible fittings. Run wire from the power source. Wiring Pump MUST be more than 10% above or below motor name plate rated voltage, or motor may overheat, causing overload tripping...
Model: ALL
Page 6
... by hand only (no wrenches) ¼ turn clockwise to pool/spa system directly in suction and outlet pipes. 3. Power-Flo LX™ / Power-Flo II™ Pump Series Installation Instructions (cont.) Electrical (cont.) Wiring (cont.) In case of a power outage, check GFCI for the mechanical shaft seal. Start-Up & Operation Prior to Start-Up Fill strainer housing...
... by hand only (no wrenches) ¼ turn clockwise to pool/spa system directly in suction and outlet pipes. 3. Power-Flo LX™ / Power-Flo II™ Pump Series Installation Instructions (cont.) Electrical (cont.) Wiring (cont.) In case of a power outage, check GFCI for the mechanical shaft seal. Start-Up & Operation Prior to Start-Up Fill strainer housing...
Model: ALL
Page 7
... plastic components in your local authorized Hayward Dealer or service center if you have any questions. The National Electrical Code requires either a three (3) foot maximum twist-lock cord set with plastic film or bags. Do not use this product. SAVE THESE INSTRUCTIONS Power-Flo LX™ / Power-Flo II™ Pump Series Storage/Winterization WARNING - Use only...
... plastic components in your local authorized Hayward Dealer or service center if you have any questions. The National Electrical Code requires either a three (3) foot maximum twist-lock cord set with plastic film or bags. Do not use this product. SAVE THESE INSTRUCTIONS Power-Flo LX™ / Power-Flo II™ Pump Series Storage/Winterization WARNING - Use only...
Model: ALL
Page 8
...rotation of motor shaft for free movement and lack of obstruction. (See steps 4 & 5 of overheating. NOTE: Your Hayward pump motor is positioned on impeller hub and remove it if necessary. Hold the motor shaft securely by either inserting a screwdriver in...or loose wiring connections; Bypass it by pulling from the impeller. 11. etc. 2. Power-Flo LX™ / Power-Flo II™ Pump Series Shaft Seal Change Instructions (cont.) Exercise extreme care in slot at motor or power drop (frequently caused by undersized wiring or extension cord use petroleum or silicone lubricants as ...
...rotation of motor shaft for free movement and lack of obstruction. (See steps 4 & 5 of overheating. NOTE: Your Hayward pump motor is positioned on impeller hub and remove it if necessary. Hold the motor shaft securely by either inserting a screwdriver in...or loose wiring connections; Bypass it by pulling from the impeller. 11. etc. 2. Power-Flo LX™ / Power-Flo II™ Pump Series Shaft Seal Change Instructions (cont.) Exercise extreme care in slot at motor or power drop (frequently caused by undersized wiring or extension cord use petroleum or silicone lubricants as ...
Model: ALL
Page 9
... pool dealer can confirm this manual. Correct suction condition or throttle return lines, if practical. Foreign matter in suction. Insure air vents are tight. Power-Flo LX™ / Power-Flo II™ Pump Series Troubleshooting (cont.) Motor Hums, But Does NOT Start - a. Check if all hose clamps are free from obstruction. Occasionally, shaft seals must...hand over return fitting will sometimes prove this point or putting in a smaller eyeball fitting. 3. Inspect strainer cover gasket regularly and replace as necessary. Hayward pumps have 5"-6" of motor shaft.
... pool dealer can confirm this manual. Correct suction condition or throttle return lines, if practical. Foreign matter in suction. Insure air vents are tight. Power-Flo LX™ / Power-Flo II™ Pump Series Troubleshooting (cont.) Motor Hums, But Does NOT Start - a. Check if all hose clamps are free from obstruction. Occasionally, shaft seals must...hand over return fitting will sometimes prove this point or putting in a smaller eyeball fitting. 3. Inspect strainer cover gasket regularly and replace as necessary. Hayward pumps have 5"-6" of motor shaft.
Model: ALL
Page 10
... Req'd.) SPX1705B SPX1580Z1 SPX1500H SPX1500KA Refer to Part No. Motor (for SW1585X20) - 2 HP ---- on Original Equipment Refer to Part No. on Original Equipment 7 Pump Housing SPX1500AA SPX1580AAP 8 Housing Nut, No. 10-24 Hex Head SPX1500Y2 (7 Req'd.) SPX1500Y2 (8 Req'd.) Motor (for SP1580X15) - 1-1/2 HP ---- SP1580, SP1580X15 SW1585X20...C-Clip SPX1515C SPX1515C * To order 2-speed motor, change "1" in suffix of model number to Part No. Power-Flo LX™ / Power-Flo II™ Pump Series Replacement Parts Parts Diagram Parts Listing Ref. Description Model No.
... Req'd.) SPX1705B SPX1580Z1 SPX1500H SPX1500KA Refer to Part No. Motor (for SW1585X20) - 2 HP ---- on Original Equipment Refer to Part No. on Original Equipment 7 Pump Housing SPX1500AA SPX1580AAP 8 Housing Nut, No. 10-24 Hex Head SPX1500Y2 (7 Req'd.) SPX1500Y2 (8 Req'd.) Motor (for SP1580X15) - 1-1/2 HP ---- SP1580, SP1580X15 SW1585X20...C-Clip SPX1515C SPX1515C * To order 2-speed motor, change "1" in suffix of model number to Part No. Power-Flo LX™ / Power-Flo II™ Pump Series Replacement Parts Parts Diagram Parts Listing Ref. Description Model No.
Model: ALL
Page 11
... for cartage, removal and/or reinstallation labor or any other conditions and terms of a use , or care, shall be repaired, at our option, without charge. Power-Flo LX™ / Power-Flo II™ Pump Series HAYWARD® LIMITED WARRANTY This pump was inspected before shipment from state to state. *Supersedes all previous publications. To original purchasers of this...
... for cartage, removal and/or reinstallation labor or any other conditions and terms of a use , or care, shall be repaired, at our option, without charge. Power-Flo LX™ / Power-Flo II™ Pump Series HAYWARD® LIMITED WARRANTY This pump was inspected before shipment from state to state. *Supersedes all previous publications. To original purchasers of this...