Hayward Sense and Dispense Support and Manuals

Get Help and Manuals for this Hayward item

View All Support Options Below
Free Hayward Sense and Dispense manuals!
Problems with Hayward Sense and Dispense?

Ask a Question

Most Recent Hayward Sense and Dispense Questions

Orp Sensor
I have a Hayward aqua rite pro and I just replaced the Hayward sense and dispense system completely....
(Posted by Stevecreager20 9 months ago)

Hayward Sense and Dispense Videos

Pool Chemical Automation W/ Wireless Control: Hayward Aquarite Pro and Sense and Dispense
Duration: 4:51
Total Views: 2,586

Popular Hayward Sense and Dispense Manual Pages

Model: AQL-CHEM - Page 1

Total Pool ChemistryTM for Aqua RiteTM Pro and Pro Logic® Installation and Operation Manual for AQL-CHEM June 2010 Download and use the latest manual at: www.hayward-pool.com
Model: AQL-CHEM - Page 2

... 4.00. Install this relay only if you have one of the pool water. With the AQL-CHEM, the Aqua Rite Pro or Pro Logic can provide a fully integrated chemistry solution for water collection and testing. Samples water from the pool filtration system and sends signals to house the probes and provide a location for your software revision. pH Dispense Pigtails: The pH Dispense pigtails...
Model: AQL-CHEM - Page 3

... all Hayward Aqua Rite Pro and Pro Logic pool controls. Relieve pressure from the pool filtration system. Turn off the pool filter pump, water features and any part of the installation, be sure to shut off input power to pass through the cell and across the probes. Compatibility The AQL-CHEM is not compatible with Aqua Rite or Aqua Logic controls. An AQL-CL chemistry...
Model: AQL-CHEM - Page 8

... internal relays. If your pH dispensing device will connect to the 120VAC pigtail or direct wired device. Installation may require retrofitting a weather-tight outlet and plug to the pigtail and dispense hardware (such as shown WHITE BLACK EP3 EP1 Aqua Rite Pro 120 VAC Ground L1 N to the pigtail or pH dispensing device. NOTE: Follow local codes for connection to 120VAC...
Model: AQL-CHEM - Page 9

... used to an internal relay. If a direct wired pH dispensing device will be connected to power the Aqua Rite Pro. Configure the output voltage to the pH device by the same voltage used , disregard the pigtail and connect directly to the diagram on these models. Installation instructions for this relay in the diagram on page 9 shows a typical installation of the enclosure.
Model: AQL-CHEM - Page 11

... Control Select the desired option related to answer questions when prompted. 6. Auto Sensing Use this mode if no pH dispenser will be connected to the configuration can be sure that is used . Detailed information about specific screens relating to the Aqua Rite Pro or Pro Logic. To enter the Chemistry Config Wizard follow the steps below . Press ">" repeatedly until...
Model: AQL-CHEM - Page 12

... the Chlorine Feed selection is not used to evaluate the pool chemistry before continuing with pH control. pH Feed Timeout To protect the pool, the Aqua Rite Pro or Pro Logic control will keep the pool filter pump on the manual setting only. ORP Auto Sensing The Aqua Rite Pro or Pro Logic refers to enter the desired pH level (7.5 default). The high alarm point is 8.1 and the...
Model: AQL-CHEM - Page 13

...allows the pool owner to "pH Dispense". pH Calibration Wizard After installation, the pH probe must be found below . Continue until finished. sion less than one test and average the results before continuing with another test kit) and consider cleaning the pH probe per the instructions found in the pH Calibration Wizard. This prevents a situation where the Aqua Rite Pro or Pro Logic is...
Model: AQL-CHEM - Page 14

... CHLORINE. 6. Clean the probe b. IMPORTANT: Balance the pool water to the ideal levels shown in the Aqua Rite Pro or Pro Logic Operation manuals. After allowing the system to run for 1 week. Set the ORP setpoint setting to this is what the Sense and Dispense system reports as well; Operation Before operating the AQL-CHEM, test and adjust the pool water chemistry to the...
Model: AQL-CHEM - Page 15

... equipment. • Check the Aqua Rite Pro or Pro Logic's display each pool season. 14 Great care must be taken when installing, maintaining and operating acid pump feed systems. Acid is detected. Some use an independent pH and chlorine test kit to understand and rectify the condition. If the display is dispensed into the pool or spa. • Only...
Model: AQL-CHEM - Page 16

...the Aqua Rite Pro or Pro Logic. A household liquid dishwashing detergent may need to ensure pH stability. Probe Storage Exposure to function properly. Store probes in a location that the probes are indications that will not be found within the Settings Menu on the Aqua Rite Pro or the Maintenance Menu on threads and reinstall probes. For the Pro Logic, this information can be clean...
Model: AQL-CHEM - Page 19

... its Aqua Rite, Aqua Rite Pro, Aqua Plus and SwimPure chlorination products to the original owner. Hayward/Goldline warrants all accessories and replacement parts for a period of the product. Likewise, Hayward/Goldline warrants all the above -identified pool automation and chlorination products for the above -identified pool automation and chlorination products installed on commercial...
Model: AQL-CHEM2 - Page 1

Total Pool ChemistryTM for Aqua RiteTM Pro and Pro Logic® Installation and Operation Manual for AQL-CHEM2 AQL-CHEM2-240 G LDLINE CON TROLS July 2009 Download and use the latest manual at: www.goldlinecontrols.com
Model: AQL-CHEM2 - Page 2

... the problem of branch/store locations n2ationwide. When used with hundreds of how to provide low cost pH control for installation instructions. CAOq2ucicank search on the Aa QstaLn-dCaHrdEMCOs2entasninkgaknidt, wire directly to the Aqua Rite Pro or Pro the Aqua Rite Pro or Pro Logic will need to handle acid. be performed prior to the AQL-CHEM manual for backyard pools without...
Model: AQL-CHEM2 - Page 4

... on the AQL-CHEM2(-240) when the pool's pH level requires adjustment. Installation instructions for CO leaks at regulator fitting. 10. After proper configuration, the Aqua Rite Pro or Pro Logic will automatically turn on the Aqua Rite Pro or the Pro Logic operating with the AQLCHEM kit. other end to the solenoid valve as pH dispense operation. Open CO2 tank valve and use...

Hayward Sense and Dispense Reviews

Do you have an experience with the Hayward Sense and Dispense that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Hayward yet.

Popular Hayward Sense and Dispense Search Terms

The following terms are frequently used to search for Hayward Sense and Dispense support:

Ask a New Question
Use the box below to post a new question about Hayward Sense and Dispense.
Manuals / Documents
Download any of our Hayward Sense and Dispense manuals for free!

We have the following 2 documents available for the Hayward Sense and Dispense:
  • Model: AQL-CHEM
  • Model: AQL-CHEM2

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Hayward Manuals

Find free Hayward Sense and Dispense manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Hayward Reviews

View thousands of Hayward Sense and Dispense user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Hayward customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Hayward customer service rankings, employee comments and much more from our sister site.

Hayward Recalls

Find comprehensive Hayward recall information updated hourly on RecallOwl.com.