Hayward Sense and Dispense Support Question
Find answers below for this question about Hayward Sense and Dispense.Need a Hayward Sense and Dispense manual? We have 2 online manuals for this item!
Question posted by Stevecreager20 on June 28th, 2023
Orp Sensor
I have a Hayward aqua rite pro and I just replaced the Hayward sense and dispense system completely. Now the system tells me that the orp sensing button is inactive. Can anyone tell me what th
Current Answers
Answer #1: Posted by SonuKumar on June 29th, 2023 3:55 AM
- Check sensor connections: Ensure that the ORP sensor is properly connected to the Aqua Rite Pro system. Verify that the sensor cable is securely plugged into the appropriate port on the system and that there are no loose or damaged connections.
- Inspect sensor wiring: Examine the wiring of the ORP sensor for any signs of damage, such as cuts, frayed wires, or corrosion. If you notice any issues, repair or replace the sensor wiring as necessary.
- Clean the ORP sensor: Over time, the ORP sensor can accumulate debris or residue, which can affect its functionality. Clean the sensor using a mild solution of water and vinegar or a specialized sensor cleaning solution. Gently scrub the sensor with a soft brush or cloth to remove any buildup. Rinse it thoroughly with clean water afterward.
- Calibrate the ORP sensor: If the previous steps don't resolve the issue, you may need to calibrate the ORP sensor. Consult the user manual or manufacturer's instructions for your specific Aqua Rite Pro system to learn the calibration procedure. Follow the provided steps carefully to ensure accurate calibration.
Please respond to my effort to provide you with the best possible solution by using the "Acceptable Solution" and/or the "Helpful" buttons when the answer has proven to be helpful.
Regards,
Sonu
Your search handyman for all e-support needs!!
Related Hayward Sense and Dispense Manual Pages
Similar Questions
Aqua Rite Pro Sense And Dispense 'check System' Error.
Buttons are unresponsive. Tried unplugging to restart system to no avail. Please advise.
Buttons are unresponsive. Tried unplugging to restart system to no avail. Please advise.
(Posted by Stephenmatus 1 year ago)
How Do I Reset The Flow Sensor Connector On The Aqua Rite Chlorine Generator
(Posted by safMiTCH 10 years ago)
Aqua Rite Pro
my aqua rite pro logic is showing high temp and not generating yet the pool temp reads at 72.
my aqua rite pro logic is showing high temp and not generating yet the pool temp reads at 72.
(Posted by trueblueservice 10 years ago)
Dual Pool Spa System But The Settings Menu Doesn't Show Pool Heater Only Spa Hea
(Posted by Anonymous-39619 12 years ago)