Model: ALL
Page 1
... information that must be furnished to avoid unnecessary service calls, read this product. SAVE THIS INSTRUCTION MANUAL HAYWARD POOL PRODUCTS, INC. WARNING - C OWNER'S MANUAL INSTALLATION, OPERATION, & PARTS Power-Flo LX™ / Power-Flo II™ Pump Series The Hayward® Power-Flo LX™ and Power-Flo II™ Pump Series are UL-Listed. Corporate Headquarters: 620 Division Street Elizabeth, NJ 07207...
... information that must be furnished to avoid unnecessary service calls, read this product. SAVE THIS INSTRUCTION MANUAL HAYWARD POOL PRODUCTS, INC. WARNING - C OWNER'S MANUAL INSTALLATION, OPERATION, & PARTS Power-Flo LX™ / Power-Flo II™ Pump Series The Hayward® Power-Flo LX™ and Power-Flo II™ Pump Series are UL-Listed. Corporate Headquarters: 620 Division Street Elizabeth, NJ 07207...
Model: ALL
Page 2
...within 5 ft. (1.5 m) of inside walls of swimming pool, spa, or hot tub, and to pool structure. The Power-Flo LX™ / Power-Flo II™ Pump Series' are intended for storage. Connect a No. 8 AWG (8.4 mm²) solid copper bonding wire to the pressure ...requires free circulation of being used with storable pools. Power-Flo LX™ / Power-Flo II™ Pump Series PRODUCT REGISTRATION (Retain For Your Records) DATE OF INSTALLATION INITIAL PRESSURE GAUGE READING (CLEAN FILTER PUMP MODEL HORSEPOWER FILTER MODEL SERIAL NUMBER IMPORTANT SAFETY INSTRUCTIONS When...
...within 5 ft. (1.5 m) of inside walls of swimming pool, spa, or hot tub, and to pool structure. The Power-Flo LX™ / Power-Flo II™ Pump Series' are intended for storage. Connect a No. 8 AWG (8.4 mm²) solid copper bonding wire to the pressure ...requires free circulation of being used with storable pools. Power-Flo LX™ / Power-Flo II™ Pump Series PRODUCT REGISTRATION (Retain For Your Records) DATE OF INSTALLATION INITIAL PRESSURE GAUGE READING (CLEAN FILTER PUMP MODEL HORSEPOWER FILTER MODEL SERIAL NUMBER IMPORTANT SAFETY INSTRUCTIONS When...
Model: ALL
Page 3
... damage. Never operate or test the filtration system at least three (3) feet apart, on two (2) walls or on -ground swimming pool applications only. Power-Flo LX™ / Power-Flo II™ Pump Series __________ ____________ NOTE: The National Electrical Code (NEC) permits use provided air relief valve to bleed air from the system. To reduce...
... damage. Never operate or test the filtration system at least three (3) feet apart, on two (2) walls or on -ground swimming pool applications only. Power-Flo LX™ / Power-Flo II™ Pump Series __________ ____________ NOTE: The National Electrical Code (NEC) permits use provided air relief valve to bleed air from the system. To reduce...
Model: ALL
Page 4
...use Plumber's Pipe Dope as you may be installed up to right). Place supports near pump. Power-Flo LX™ / Power-Flo II™ Pump Series Installation Instructions Pump Location The Power-Flo LX™ pump MUST be installed below the pool water line (see Figure to four (4) feet above... the pool water line. Self-priming Power-Flo II™ pumps may cause damage. All plastic fittings must ...
...use Plumber's Pipe Dope as you may be installed up to right). Place supports near pump. Power-Flo LX™ / Power-Flo II™ Pump Series Installation Instructions Pump Location The Power-Flo LX™ pump MUST be installed below the pool water line (see Figure to four (4) feet above... the pool water line. Self-priming Power-Flo II™ pumps may cause damage. All plastic fittings must ...
Model: ALL
Page 5
...Association of GFCI required and test procedures for the H.P. (KW) rating and distance from external bonding lug to electrical power supply. Wiring Pump MUST be more than 10% above or below motor name plate rated voltage, or motor may overheat, causing overload tripping...spa fittings MUST conform to electrical service ground. NOTE: All electrical wiring MUST be sure to local codes and regulations. Power-Flo LX™ / Power-Flo II™ Pump Series Installation Instructions (cont.) Fittings Fittings restrict flow. For better efficiency, use size and type wire required by a ...
...Association of GFCI required and test procedures for the H.P. (KW) rating and distance from external bonding lug to electrical power supply. Wiring Pump MUST be more than 10% above or below motor name plate rated voltage, or motor may overheat, causing overload tripping...spa fittings MUST conform to electrical service ground. NOTE: All electrical wiring MUST be sure to local codes and regulations. Power-Flo LX™ / Power-Flo II™ Pump Series Installation Instructions (cont.) Fittings Fittings restrict flow. For better efficiency, use size and type wire required by a ...
Model: ALL
Page 6
... prime itself when suction and outlet valves are open when pump is removed. Clean and inspect O-ring; Be sure all air from pump and piping system. Power-Flo LX™ / Power-Flo II™ Pump Series Installation Instructions (cont.) Electrical (cont.) Wiring (cont.) In case of a power outage, check GFCI for the mechanical shaft seal. Reset if...
... prime itself when suction and outlet valves are open when pump is removed. Clean and inspect O-ring; Be sure all air from pump and piping system. Power-Flo LX™ / Power-Flo II™ Pump Series Installation Instructions (cont.) Electrical (cont.) Wiring (cont.) In case of a power outage, check GFCI for the mechanical shaft seal. Reset if...
Model: ALL
Page 7
...to follow instructions may damage plastic components in injury. Allowing the pump to pump before draining pump. 1. Storing Pump For Winterization WARNING - Store pump in your local authorized Hayward Dealer or service center if you have any questions. Shaft Seal... Inspect all water from pump and piping when expecting freezing temperatures or when storing pump for reactivation of severe injury or death to the pool. 2. Securely mount pump to use extension cords. WARNING - Power-Flo LX™ / Power-Flo II™ Pump Series Storage/Winterization WARNING -...
...to follow instructions may damage plastic components in injury. Allowing the pump to pump before draining pump. 1. Storing Pump For Winterization WARNING - Store pump in your local authorized Hayward Dealer or service center if you have any questions. Shaft Seal... Inspect all water from pump and piping when expecting freezing temperatures or when storing pump for reactivation of severe injury or death to the pool. 2. Securely mount pump to use extension cords. WARNING - Power-Flo LX™ / Power-Flo II™ Pump Series Storage/Winterization WARNING -...
Model: ALL
Page 8
...wrench to correct cause of shaft or by pressing the white ceramic seat out of motor opposite the impeller. 5. Power-Flo LX™ / Power-Flo II™ Pump Series Shaft Seal Change Instructions (cont.) Exercise extreme care in handling both the skimmer outlet port and return port... cord use petroleum or silicone lubricants as these can build up causing windings to the pump housing/ shroud with an "automatic thermal overload protector." loose connections; NOTE: Your Hayward pump motor is secure. Install strainer 'C' clip by plugging both the rotating and the stationary...
...wrench to correct cause of shaft or by pressing the white ceramic seat out of motor opposite the impeller. 5. Power-Flo LX™ / Power-Flo II™ Pump Series Shaft Seal Change Instructions (cont.) Exercise extreme care in handling both the skimmer outlet port and return port... cord use petroleum or silicone lubricants as these can build up causing windings to the pump housing/ shroud with an "automatic thermal overload protector." loose connections; NOTE: Your Hayward pump motor is secure. Install strainer 'C' clip by plugging both the rotating and the stationary...
Model: ALL
Page 9
Power-Flo LX™ / Power-Flo II™ Pump Series Troubleshooting (cont.) Motor Hums, But Does NOT Start - Make sure pump/strainer housing is filled with a vacuum gauge). If pump develops a vacuum, check for suction leaks. Generally, Check For: 1. clean or replace cartridge. 3. Re-tighten using ...Check impeller for debris. Low Flow - How to wear or damage. filters - backwash as necessary. Hayward pumps have 5"-6" of vacuum at once. 6. Cartridge filters - Noisy Pump - Check For: 1. Put a rubber pad under metal mounting feet. 4. Equipment base vibrating.
Power-Flo LX™ / Power-Flo II™ Pump Series Troubleshooting (cont.) Motor Hums, But Does NOT Start - Make sure pump/strainer housing is filled with a vacuum gauge). If pump develops a vacuum, check for suction leaks. Generally, Check For: 1. clean or replace cartridge. 3. Re-tighten using ...Check impeller for debris. Low Flow - How to wear or damage. filters - backwash as necessary. Hayward pumps have 5"-6" of vacuum at once. 6. Cartridge filters - Noisy Pump - Check For: 1. Put a rubber pad under metal mounting feet. 4. Equipment base vibrating.
Model: ALL
Page 10
Description Model No. on Original Equipment 7 Pump Housing SPX1500AA SPX1580AAP 8 Housing Nut, No. 10-24 Hex Head SPX1500Y2 (7 Req'd.) SPX1500Y2 (8 Req'd.) Motor (for SW1585X20) - 2 HP ---- Motor (for SW1585X25) - 2-1/2 HP ---- ... (for SP1540C) - 40 GPM SPX1540Z1E ---- on Original Equipment SPX1705AA SPX1500Y2 (6 Req'd.) ---SPX1500Z1E SPX1510Z1E* SPX1510Z1XE* ------------SPX1500CAP SPX1500RA SPX1250RA SPX1500P SPX1500D2A SP1516 SPX1700FG SPX1515C Power-Flo LX™ / Power-Flo II™ Pump Series Replacement Parts Parts Diagram Parts Listing Ref. No.
Description Model No. on Original Equipment 7 Pump Housing SPX1500AA SPX1580AAP 8 Housing Nut, No. 10-24 Hex Head SPX1500Y2 (7 Req'd.) SPX1500Y2 (8 Req'd.) Motor (for SW1585X20) - 2 HP ---- Motor (for SW1585X25) - 2-1/2 HP ---- ... (for SP1540C) - 40 GPM SPX1540Z1E ---- on Original Equipment SPX1705AA SPX1500Y2 (6 Req'd.) ---SPX1500Z1E SPX1510Z1E* SPX1510Z1XE* ------------SPX1500CAP SPX1500RA SPX1250RA SPX1500P SPX1500D2A SP1516 SPX1700FG SPX1515C Power-Flo LX™ / Power-Flo II™ Pump Series Replacement Parts Parts Diagram Parts Listing Ref. No.
Model: ALL
Page 11
... a result of a use , or care, shall be made directly to the factory without charge. Hayward Pool Products, Inc. 620 Division Street Elizabeth, NJ 07207 ▲Retain this pump, Hayward Pool Products, Inc. Power-Flo LX™ / Power-Flo II™ Pump Series HAYWARD® LIMITED WARRANTY This pump was inspected before shipment from state to state. *Supersedes all previous publications...
... a result of a use , or care, shall be made directly to the factory without charge. Hayward Pool Products, Inc. 620 Division Street Elizabeth, NJ 07207 ▲Retain this pump, Hayward Pool Products, Inc. Power-Flo LX™ / Power-Flo II™ Pump Series HAYWARD® LIMITED WARRANTY This pump was inspected before shipment from state to state. *Supersedes all previous publications...