Manual
Page 2
GIGA -BYTE TECHNOLOGY CO., LTD. [3] Open Windows IE and connect to target system BMC Web UI for logon to system. [4] Power off the target system [5] Update BIOS (1.) Select Update page (2.) Select Firmware Type to "BIOS & ME" (3.) Select File Path of "image.RBU" (4.) Click Upload button
GIGA -BYTE TECHNOLOGY CO., LTD. [3] Open Windows IE and connect to target system BMC Web UI for logon to system. [4] Power off the target system [5] Update BIOS (1.) Select Update page (2.) Select Firmware Type to "BIOS & ME" (3.) Select File Path of "image.RBU" (4.) Click Upload button
Manual
Page 6
GIGA -BYTE TECHNOLOGY CO., LTD. 2. BMC command format table Preparation [1] Get BIOS image file "image.RBU" of target system. [2] Make sure target system BMC is live. [3] Get BMC IP address of target system. [4] Download TFTP service application for Linux client PC (Please users set up their own TFTP server.). [6] Get ipmitool. 2.2. Tftpd64.exe/Tftpd32.exe through BMC Command-line interface 2.1. Update BIOS through free download). [5] Setup TFTP server for Windows client PC (e.g.
GIGA -BYTE TECHNOLOGY CO., LTD. 2. BMC command format table Preparation [1] Get BIOS image file "image.RBU" of target system. [2] Make sure target system BMC is live. [3] Get BMC IP address of target system. [4] Download TFTP service application for Linux client PC (Please users set up their own TFTP server.). [6] Get ipmitool. 2.2. Tftpd64.exe/Tftpd32.exe through BMC Command-line interface 2.1. Update BIOS through free download). [5] Setup TFTP server for Windows client PC (e.g.
Manual
Page 8
e.g. Use command 0x06 0x01 to target system BMC through ipmitool. Update BIOS (Sample on Windows client PC) [1] Set up TFTP service application Execute Tftpd64.exe Set Current Directory to file path of "image.RBU" GIGA -BYTE TECHNOLOGY CO., LTD. [2] Execute cmd.exe and connect to check connect BMC is success or not. 2.3. ipmitool -H 10.1.27.150 -U admin -P password raw 0x06 0x01
e.g. Use command 0x06 0x01 to target system BMC through ipmitool. Update BIOS (Sample on Windows client PC) [1] Set up TFTP service application Execute Tftpd64.exe Set Current Directory to file path of "image.RBU" GIGA -BYTE TECHNOLOGY CO., LTD. [2] Execute cmd.exe and connect to check connect BMC is success or not. 2.3. ipmitool -H 10.1.27.150 -U admin -P password raw 0x06 0x01
Manual
Page 10
GIGA -BYTE TECHNOLOGY CO., LTD. [4] Upload "image.RBU" through TFTP service application. ipmitool -H 10.1.27.150 -U admin -P password raw 0x2e 0x20 0x0a 0x3c 0x00 0x0e 0x00 0x00 0x0a 0x01 0x1b 0x34 0x69 0x6d 0x61 0x67 0x65 0x2e 0x52 0x42 0x55 Command format: raw...0x65 0x2e 0x52 0x42 0x55 = image.RBU [5] Check upload status e.g. e.g. ipmitool -H 10.1.27.150 -U admin -P password raw 0x2e 0x21 0x0a 0x3c 0x00 0x0e Response: 0a 3c 00 01 00 Byte 1 = 00h : Command Completed Normally Byte 2 = 01h : Copying To Scratch Byte 3 = 00h : Update Progress (If byte 2 is 06, this data is available.)
GIGA -BYTE TECHNOLOGY CO., LTD. [4] Upload "image.RBU" through TFTP service application. ipmitool -H 10.1.27.150 -U admin -P password raw 0x2e 0x20 0x0a 0x3c 0x00 0x0e 0x00 0x00 0x0a 0x01 0x1b 0x34 0x69 0x6d 0x61 0x67 0x65 0x2e 0x52 0x42 0x55 Command format: raw...0x65 0x2e 0x52 0x42 0x55 = image.RBU [5] Check upload status e.g. e.g. ipmitool -H 10.1.27.150 -U admin -P password raw 0x2e 0x21 0x0a 0x3c 0x00 0x0e Response: 0a 3c 00 01 00 Byte 1 = 00h : Command Completed Normally Byte 2 = 01h : Copying To Scratch Byte 3 = 00h : Update Progress (If byte 2 is 06, this data is available.)
Manual
Page 2
... 4 Software Install ...5 Prerequisites on remote management PC 5 Install Java Tool ...5 Gigabyte Content Management Network Configuration 6 Using the Web UI...8 Gigabyte Content Management System Console Overview 9 Enter Gigabyte Content Management System Console 10 Properties ...10 Configuration ...11 Network...11 Network Security ...12 Security ...13 Users ...14 Services ...15 IPMI ...16 Time Setting ...18 Language ...19 Sessions ...20 LDAP ...21 Updates ...22 Utilities ...23 Server Information ...24 General Setting...24 Power Control ...25 Power...
... 4 Software Install ...5 Prerequisites on remote management PC 5 Install Java Tool ...5 Gigabyte Content Management Network Configuration 6 Using the Web UI...8 Gigabyte Content Management System Console Overview 9 Enter Gigabyte Content Management System Console 10 Properties ...10 Configuration ...11 Network...11 Network Security ...12 Security ...13 Users ...14 Services ...15 IPMI ...16 Time Setting ...18 Language ...19 Sessions ...20 LDAP ...21 Updates ...22 Utilities ...23 Server Information ...24 General Setting...24 Power Control ...25 Power...
Manual
Page 5
... LAN. FRU information report includes main board part number, product name, and manufacturer, etc.) Health status/Hardware monitoring report. Events log, view, and clear. Event notification via PET (Platform Event Trap). Platform Event Filtering (PEF) to take selected action for selected events. Chassis management includes power control and status report, front panel buttons and LEDs control. Support...
... LAN. FRU information report includes main board part number, product name, and manufacturer, etc.) Health status/Hardware monitoring report. Events log, view, and clear. Event notification via PET (Platform Event Trap). Platform Event Filtering (PEF) to take selected action for selected events. Chassis management includes power control and status report, front panel buttons and LEDs control. Support...
Manual
Page 6
... your system for the following required configuration requirements: Supported Browsers: Internet Explorer 8~12 Google chrome Version 29.0.1547.66m Firefox 2.0 JAVA Recommended Version 8 Update 25 or later version (file size: ~ 623KB) Install Java Tool Please follow the instruction to http://www.java.com 2. Choose the folder location. (Save the file to a known location on Agree and Start Free Download 4. Click Save. 8.
... your system for the following required configuration requirements: Supported Browsers: Internet Explorer 8~12 Google chrome Version 29.0.1547.66m Firefox 2.0 JAVA Recommended Version 8 Update 25 or later version (file size: ~ 623KB) Install Java Tool Please follow the instruction to http://www.java.com 2. Choose the folder location. (Save the file to a known location on Agree and Start Free Download 4. Click Save. 8.
Manual
Page 7
Select Server Management. 3. Save and Exit. 6. Define Configuration Address source to BIOS setup menu. 2. The BMC IP Address will appear on the IPv4 Address parameter. 6 Go to DynamicBmcDhcp or Static. 5. Select BMC network Configuration 4. Gigabyte Content Management Network Configuration Please follow the instruction to enable the console redirection function. 1.
Select Server Management. 3. Save and Exit. 6. Define Configuration Address source to BIOS setup menu. 2. The BMC IP Address will appear on the IPv4 Address parameter. 6 Go to DynamicBmcDhcp or Static. 5. Select BMC network Configuration 4. Gigabyte Content Management Network Configuration Please follow the instruction to enable the console redirection function. 1.
Manual
Page 10
... Intel C20x series chipset, please enter the following values: Username: admin Password: password If your identified IP. The IP address can be found using the root user name and password, you log in your motherboard is advised that once you have full administrative powers. Enter the following values: Username: root Password: superuser The default user name and password are in using your DHCP server. 2. Gigabyte Content Management...
... Intel C20x series chipset, please enter the following values: Username: admin Password: password If your identified IP. The IP address can be found using the root user name and password, you log in your motherboard is advised that once you have full administrative powers. Enter the following values: Username: root Password: superuser The default user name and password are in using your DHCP server. 2. Gigabyte Content Management...
Manual
Page 12
... list. 1. Shared Mode When set to Failover Mode, you can configure the BMC related settings through the NIC2 port. (Shared NIC Mode) 3. Failover Mode When set to take effect immediately, click "Refresh" to Dedicate Mode, you finish configuration, click Apply Change. Configuration Network You can configure the BMC related settings through the BMC port. 2. Please note that the changes may not take effect of changes. 11 Dedicate Mode When set to Shared Mode...
... list. 1. Shared Mode When set to Failover Mode, you can configure the BMC related settings through the NIC2 port. (Shared NIC Mode) 3. Failover Mode When set to take effect immediately, click "Refresh" to Dedicate Mode, you finish configuration, click Apply Change. Configuration Network You can configure the BMC related settings through the BMC port. 2. Please note that the changes may not take effect of changes. 11 Dedicate Mode When set to Shared Mode...
Manual
Page 17
... list. Privilege levels tell the BMC which commands are allowed, except for configuration commands that the Administrator is set, select the Baud Rate and Flow Control from a remote location. IPMI This screen contains two sections: IPMI Serial and IPMI Settings. With Channel Privilege Level Limit, users can change user access privileges. Administrator All BMC commands are four serial configuration in IPMI Serial: Connection Mode Settings, Baud Rate, Flow Control, and Channel...
... list. Privilege levels tell the BMC which commands are allowed, except for configuration commands that the Administrator is set, select the Baud Rate and Flow Control from a remote location. IPMI This screen contains two sections: IPMI Serial and IPMI Settings. With Channel Privilege Level Limit, users can change user access privileges. Administrator All BMC commands are four serial configuration in IPMI Serial: Connection Mode Settings, Baud Rate, Flow Control, and Channel...
Manual
Page 18
IPMI Settings IPMI Settings provides remote configuration over LAN. To activate IPMI remote configuration by LAN, check Enable IPMI Over LAN option, define the Channel Privilege Level Limit, and enter the Encryption Key. When you finish the configuration, click "Apply Changes". 17
IPMI Settings IPMI Settings provides remote configuration over LAN. To activate IPMI remote configuration by LAN, check Enable IPMI Over LAN option, define the Channel Privilege Level Limit, and enter the Encryption Key. When you finish the configuration, click "Apply Changes". 17
Manual
Page 19
... Step mode to configure the Network Time acquisition method. With Administrator or Operator privilege level, you can request an immediate clock synchronization with the NTP server; Time Setting This page provides the mechanism to aggressively change the time using settimeofday() system call. 18 Select Slew mode when you can modify configuration settings and click the Apply Changes button to execute the settings, as...
... Step mode to configure the Network Time acquisition method. With Administrator or Operator privilege level, you can request an immediate clock synchronization with the NTP server; Time Setting This page provides the mechanism to aggressively change the time using settimeofday() system call. 18 Select Slew mode when you can modify configuration settings and click the Apply Changes button to execute the settings, as...
Manual
Page 25
Click Refresh to update current health status for Voltage, Power Supplies, Fans and Temperatures. 24 Define Auto Refresh Interval and Sensor Type form the drop-down list, and select Display Type. Server Information General Setting This page displays a real-time record of the system health related information such as Voltage, Power Supplies, Fans and Temperatures.
Click Refresh to update current health status for Voltage, Power Supplies, Fans and Temperatures. 24 Define Auto Refresh Interval and Sensor Type form the drop-down list, and select Display Type. Server Information General Setting This page displays a real-time record of the system health related information such as Voltage, Power Supplies, Fans and Temperatures.
Manual
Page 3
... 1-5-4 pgadminIII Installation Procedure (Optional 15 1-5-5 Login Gigabyte Server Management Console 16 Chapter 2 Gigabyte Server Management Console 17 2-1 Overview...17 2-2 Enter Gigabyte Server Management Console 18 2-2-1 Node Info...18 2-2-1-1 Node ID...20 Power Consumption...20 SEL ...21 Node Detail...21 Chassis ...22 Sensor ...23 Trap IP Destination List...24 Platform Events...25 BMC Update...26 BIOS Update...26 Power Limit...27 IP Configuration...27 CPU Utilization...27...
... 1-5-4 pgadminIII Installation Procedure (Optional 15 1-5-5 Login Gigabyte Server Management Console 16 Chapter 2 Gigabyte Server Management Console 17 2-1 Overview...17 2-2 Enter Gigabyte Server Management Console 18 2-2-1 Node Info...18 2-2-1-1 Node ID...20 Power Consumption...20 SEL ...21 Node Detail...21 Chassis ...22 Sensor ...23 Trap IP Destination List...24 Platform Events...25 BMC Update...26 BIOS Update...26 Power Limit...27 IP Configuration...27 CPU Utilization...27...
Manual
Page 5
... required configuration requirements: • System Processor: 2 GHz and above • System Memory: Minimum 4 GB RAM • Free Disk Space: 1000 GB at least • Node servers : 255 maximum 1-3 Software Requirement 1-3-1 Prerequisites on remote management server Supported Browsers: • Internet Explorer 9 or later • Google Chrome 39.0.2171.65 m or later • Mozilla Firefox 33.1.1 Operating System: • Windows 2008...
... required configuration requirements: • System Processor: 2 GHz and above • System Memory: Minimum 4 GB RAM • Free Disk Space: 1000 GB at least • Node servers : 255 maximum 1-3 Software Requirement 1-3-1 Prerequisites on remote management server Supported Browsers: • Internet Explorer 9 or later • Google Chrome 39.0.2171.65 m or later • Mozilla Firefox 33.1.1 Operating System: • Windows 2008...
Manual
Page 16
Enter Database User Name postgres • This utility supported CentOS 6.3 or later version. • PostgreSQL must be execute in root authority. • In Fedora 19, you have to install package in the following: Locate and edit your distributions .repo file, located: vi /etc/yum.repos.d/fedora.repo and /etc/yum.repos.d/fedora-updates.repo ([fedora] sections) Install PGDG RPM file: curl -O http://yum...
Enter Database User Name postgres • This utility supported CentOS 6.3 or later version. • PostgreSQL must be execute in root authority. • In Fedora 19, you have to install package in the following: Locate and edit your distributions .repo file, located: vi /etc/yum.repos.d/fedora.repo and /etc/yum.repos.d/fedora-updates.repo ([fedora] sections) Install PGDG RPM file: curl -O http://yum...
Manual
Page 31
... information. Displays the connected Node SEL information. Click Refresh to update current Node FRU LIST. Click Refresh to update current group SEL. Set Chassis Identify: Define timeout to power on selected ID to power off /cycle and hard reset the remote host system. Define the timeout from the drop-down list, when you finish the configuration, click Apply. Click Clear to update current system power control status...
... information. Displays the connected Node SEL information. Click Refresh to update current Node FRU LIST. Click Refresh to update current group SEL. Set Chassis Identify: Define timeout to power on selected ID to power off /cycle and hard reset the remote host system. Define the timeout from the drop-down list, when you finish the configuration, click Apply. Click Clear to update current system power control status...
Manual
Page 32
... IPv4 uses only 32 bits. Click Upload to update to be updated remotely. When you finish the configuration, click Update. Enable/Disable IPv6 Configuration. Sensor Trap IP Destination Platform Events BMC Update BIOS Update Power Limit IPv6 Configuration Displays the status of firmware. To update the Trap IP Destination List, click Refresh. For each PEF, you can choose the action to the new version of node power consumption/fan speed/temperature. BMC Update Guide in...
... IPv4 uses only 32 bits. Click Upload to update to be updated remotely. When you finish the configuration, click Update. Enable/Disable IPv6 Configuration. Sensor Trap IP Destination Platform Events BMC Update BIOS Update Power Limit IPv6 Configuration Displays the status of firmware. To update the Trap IP Destination List, click Refresh. For each PEF, you can choose the action to the new version of node power consumption/fan speed/temperature. BMC Update Guide in...
Manual
Page 38
... catalina file fail Close file channel fail Get power status fail Send chassis command fail Set IPv6 enable/disable configuration fail Get power reading fail Get CPU temperature fail Set boot option fail Set chassis identify fail Power limit deactivate Description Network is not connected or BMC is busy. Network is not connected or BMC is busy. Network is not connected or BMC is busy. Network is not connected or BMC is busy. Can not access database...
... catalina file fail Close file channel fail Get power status fail Send chassis command fail Set IPv6 enable/disable configuration fail Get power reading fail Get CPU temperature fail Set boot option fail Set chassis identify fail Power limit deactivate Description Network is not connected or BMC is busy. Network is not connected or BMC is busy. Network is not connected or BMC is busy. Network is not connected or BMC is busy. Can not access database...