FE 787 Users Manual
Page 4
787 Users Manual Simulate Mode ...22 Changing the Current Span 22 Producing a Steady mA Output 24 Manually Stepping the mA Output 25 Auto Ramping the mA Output 26 Power-Up Options...27 Battery Life...28 Using the Holster and Flex-Stand 28 Maintenance ...28 General Maintenance 28 Calibration...28 Replacing the Battery 30 Replacing a Fuse ...31 If the Meter does not Work 32 Replacement Parts and Accessories 33 Specifications...36 Index ii
787 Users Manual Simulate Mode ...22 Changing the Current Span 22 Producing a Steady mA Output 24 Manually Stepping the mA Output 25 Auto Ramping the mA Output 26 Power-Up Options...27 Battery Life...28 Using the Holster and Flex-Stand 28 Maintenance ...28 General Maintenance 28 Calibration...28 Replacing the Battery 30 Replacing a Fuse ...31 If the Meter does not Work 32 Replacement Parts and Accessories 33 Specifications...36 Index ii
FE 787 Users Manual
Page 8
International Symbols Meaning Alternating current Symbol Meaning Earth ground Direct current Fuse Alternating or direct current Conforms to European Union directives Refer to the supply system but less than the primary supply system (CAT IV). 4 787 Users Manual Symbol c Table 1. Mains, wall outlets, main distribution levels connected closer to the manual for information...
International Symbols Meaning Alternating current Symbol Meaning Earth ground Direct current Fuse Alternating or direct current Conforms to European Union directives Refer to the supply system but less than the primary supply system (CAT IV). 4 787 Users Manual Symbol c Table 1. Mains, wall outlets, main distribution levels connected closer to the manual for information...
FE 787 Users Manual
Page 9
...OFF OUTPUT 0-24mA SOURCE + SIMULATE + A mA COM V 0.44A (1A /30 sec) FUSED 30mA FUSED CAT 1000V Pushbuttons Input/Output Jacks Figure 1. How to Get Started If you are unfamiliar with Fluke 80 Series DMMs, or DMMs in general, read "Using the Current Output Functions," review the ...tables and figures in "Getting Acquainted with the Fluke 80 Series DMM, read "Measuring Electrical Parameters" in addition to the sections referenced in the previous paragraph. Fluke 787 ProcessMeter ee014f.eps 5 If you are familiar with the Meter," and begin...
...OFF OUTPUT 0-24mA SOURCE + SIMULATE + A mA COM V 0.44A (1A /30 sec) FUSED 30mA FUSED CAT 1000V Pushbuttons Input/Output Jacks Figure 1. How to Get Started If you are unfamiliar with Fluke 80 Series DMMs, or DMMs in general, read "Using the Current Output Functions," review the ...tables and figures in "Getting Acquainted with the Fluke 80 Series DMM, read "Measuring Electrical Parameters" in addition to the sections referenced in the previous paragraph. Fluke 787 ProcessMeter ee014f.eps 5 If you are familiar with the Meter," and begin...
FE 787 Users Manual
Page 10
787 Users Manual Getting Acquainted with the Meter To become familiar with the features and functions of the meter, study the following figures and tables. • ... Table 6 explain what all the elements of the display indicate. Input/Output Jacks ee001f.eps 6 OUTPUT 0-24mA 1 SOURCE + SIMULATE + 3 A mA COM V 0.44A (1A /30 sec) FUSED 30mA FUSED CAT 1000V 2 4 Figure 2.
787 Users Manual Getting Acquainted with the Meter To become familiar with the features and functions of the meter, study the following figures and tables. • ... Table 6 explain what all the elements of the display indicate. Input/Output Jacks ee001f.eps 6 OUTPUT 0-24mA 1 SOURCE + SIMULATE + 3 A mA COM V 0.44A (1A /30 sec) FUSED 30mA FUSED CAT 1000V 2 4 Figure 2.
FE 787 Users Manual
Page 11
... an external loop supply.) 7 Simulate Transmitter Function Output for transmitter simulation to 24 mA. (Use in series with a 440 mA fuse. COM Common for dc current to 1000V, Ω, continuity, and diode test. V Input for up to 24 mA. (Use in series with an external loop ...
... an external loop supply.) 7 Simulate Transmitter Function Output for transmitter simulation to 24 mA. (Use in series with a 440 mA fuse. COM Common for dc current to 1000V, Ω, continuity, and diode test. V Input for up to 24 mA. (Use in series with an external loop ...
FE 787 Users Manual
Page 25
Sourcing Current ee010f.eps 21 787 PROCESSMETER MIN MAX % STEP RANGE COARSE REL HOLD H FINE Hz mV V mA A OUTPUT mA V mA OFF OUTPUT 0-24mA SOURCE + SIMULATE + A mA COM V 0.44A (1A /30 sec) FUSED 30mA FUSED CAT 1000V ProcessMeter Using the Current Output Functions 40 20 60 80 0 100 Figure 7.
Sourcing Current ee010f.eps 21 787 PROCESSMETER MIN MAX % STEP RANGE COARSE REL HOLD H FINE Hz mV V mA A OUTPUT mA V mA OFF OUTPUT 0-24mA SOURCE + SIMULATE + A mA COM V 0.44A (1A /30 sec) FUSED 30mA FUSED CAT 1000V ProcessMeter Using the Current Output Functions 40 20 60 80 0 100 Figure 7.
FE 787 Users Manual
Page 27
dc V Power Supply COM +24V 787 PROCESSMETER MIN MAX % STEP RANGE COARSE REL HOLD H FINE Hz mV V mA A OUTPUT mA V mA OFF OUTPUT 0-24mA SOURCE + SIMULATE + A mA COM V 0.44A (1A /30 sec) FUSED 30mA FUSED CAT 1000V ProcessMeter Using the Current Output Functions 40 20 60 80 0 100 Figure 8. Simulating a Transmitter ee011f.eps 23
dc V Power Supply COM +24V 787 PROCESSMETER MIN MAX % STEP RANGE COARSE REL HOLD H FINE Hz mV V mA A OUTPUT mA V mA OFF OUTPUT 0-24mA SOURCE + SIMULATE + A mA COM V 0.44A (1A /30 sec) FUSED 30mA FUSED CAT 1000V ProcessMeter Using the Current Output Functions 40 20 60 80 0 100 Figure 8. Simulating a Transmitter ee011f.eps 23
FE 787 Users Manual
Page 35
... between the meter test leads. If the resistance is about 1Ω, the fuse is properly seated. 8. Replacing a Fuse ! Warning To avoid personal injury or damage to mA A L. 2. Both fuses are fused with the exact type specified: 440 mA 1000V fast-blow fuse, Fluke PN 943121. Make sure the rotary switch is good. Close the case and...
... between the meter test leads. If the resistance is about 1Ω, the fuse is properly seated. 8. Replacing a Fuse ! Warning To avoid personal injury or damage to mA A L. 2. Both fuses are fused with the exact type specified: 440 mA 1000V fast-blow fuse, Fluke PN 943121. Make sure the rotary switch is good. Close the case and...
FE 787 Users Manual
Page 36
... has lapsed, the meter will be repaired and returned for a fixed fee. 787 Users Manual If the Meter does not Work • Examine the case for information and price. 1 Figure 11. Contact a Fluke Service Center for physical damage. If there is under warranty, it will be ...repaired or replaced (at Fluke's option) and returned at no further attempt to use the meter, and contact a Fluke Service Center. • Check the battery, fuses, and test leads. • ...
... has lapsed, the meter will be repaired and returned for a fixed fee. 787 Users Manual If the Meter does not Work • Examine the case for information and price. 1 Figure 11. Contact a Fluke Service Center for physical damage. If there is under warranty, it will be ...repaired or replaced (at Fluke's option) and returned at no further attempt to use the meter, and contact a Fluke Service Center. • Check the battery, fuses, and test leads. • ...
FE 787 Users Manual
Page 37
... numbers or addresses shown on page 1 of this manual. 33 To find out how to the meter, use only the specified replacement fuse, 440 mA 1000V fast-blow, Fluke PN 943121. Warning To avoid personal injury or damage to order parts or accessories use only the replacement parts specified here. Many more...
... numbers or addresses shown on page 1 of this manual. 33 To find out how to the meter, use only the specified replacement fuse, 440 mA 1000V fast-blow, Fluke PN 943121. Warning To avoid personal injury or damage to order parts or accessories use only the replacement parts specified here. Many more...
FE 787 Users Manual
Page 38
787 Users Manual Item BT1 CG81Y ! Replacement Parts Description 9V battery, ANSI/NEDA 1604A or IEC 6LR61 Holster, Yellow Fuse, 440 mA, 1000V fast-blow Case top Case bottom Case screw Non-skid foot O-ring for input/output receptacle Battery door Battery door ... set Alligator clips for use with TL75 test lead set Industrial test lead set Product Overview Manual Users Manual (CD-ROM) Calibration Manual (not shown) Fluke PN or Model no. 614487 CG81G 943121 619962 619939 832246 824466 831933 619947 948609 646932 TL75 AC70A TL20 1586717 1586721 641891 Quantity 1 1 2 1 1 3 2 1 1 2 1 1 1 Option 1 1...
787 Users Manual Item BT1 CG81Y ! Replacement Parts Description 9V battery, ANSI/NEDA 1604A or IEC 6LR61 Holster, Yellow Fuse, 440 mA, 1000V fast-blow Case top Case bottom Case screw Non-skid foot O-ring for input/output receptacle Battery door Battery door ... set Alligator clips for use with TL75 test lead set Industrial test lead set Product Overview Manual Users Manual (CD-ROM) Calibration Manual (not shown) Fluke PN or Model no. 614487 CG81G 943121 619962 619939 832246 824466 831933 619947 948609 646932 TL75 AC70A TL20 1586717 1586721 641891 Quantity 1 1 2 1 1 3 2 1 1 2 1 1 1 Option 1 1...
FE 787 Users Manual
Page 42
...Maximum crest factor: 3 For non-sinusoidal waveforms, add ±(2% reading + 2% f.s.) typical Overload protection 440 mA, 1000V fast-blow fuse DC Current Measurement Range Resolution Accuracy, ±(% of amplitude range. 787 Users Manual AC Current Measurement Range 45 Hz to 2 kHz Resolution Accuracy, ±(% of Reading + Counts) 1.000A (Note) 0.....000 mA 0.001 mA 1.000A (Note) 0.001A Note: 440 mA continuous, 1A 30 seconds maximum Overload protection: 440 mA, 1000V fast-blow fuse 0.05% + 2 0.2% + 2 Typical Burden Voltage 1.5V/A Typical Burden Voltage 14 mV/mA 1.5V/A 38
...Maximum crest factor: 3 For non-sinusoidal waveforms, add ±(2% reading + 2% f.s.) typical Overload protection 440 mA, 1000V fast-blow fuse DC Current Measurement Range Resolution Accuracy, ±(% of amplitude range. 787 Users Manual AC Current Measurement Range 45 Hz to 2 kHz Resolution Accuracy, ±(% of Reading + Counts) 1.000A (Note) 0.....000 mA 0.001 mA 1.000A (Note) 0.001A Note: 440 mA continuous, 1A 30 seconds maximum Overload protection: 440 mA, 1000V fast-blow fuse 0.05% + 2 0.2% + 2 Typical Burden Voltage 1.5V/A Typical Burden Voltage 14 mV/mA 1.5V/A 38
FE 787 Users Manual
Page 48
Flex-Stand, 28 Freezing a reading (TouchHold), 19 Fuse, checking and replacing, 31 -H- See Current output -P- Jacks, 7 -K- Input/Output jacks, 7 -J- mA output. Offset, programming an, 19 Options, power-up options, 27 Pushbuttons, 12 See Current output Mailing address for Fluke, 2 Maintenance, 28 Malfunction, 32 Measuring, 17 MIN MAX recording, 18 -O- Loop supply, external, 22 44 M- Knob positions, 9, 11 -L- Holster, 28 -I- Parts, replacement, 34 Power-up , 27 Output. 787 Users Manual -F-
Flex-Stand, 28 Freezing a reading (TouchHold), 19 Fuse, checking and replacing, 31 -H- See Current output -P- Jacks, 7 -K- Input/Output jacks, 7 -J- mA output. Offset, programming an, 19 Options, power-up options, 27 Pushbuttons, 12 See Current output Mailing address for Fluke, 2 Maintenance, 28 Malfunction, 32 Measuring, 17 MIN MAX recording, 18 -O- Loop supply, external, 22 44 M- Knob positions, 9, 11 -L- Holster, 28 -I- Parts, replacement, 34 Power-up , 27 Output. 787 Users Manual -F-