Fluke 726 Process Calibrator Datasheet
Page 1
... for certified RTD probes for enhanced temperature measurement. • New voltage input protection design for later analysis. The Fluke 726 Precision Multifunction Process Calibrator is designed specifically for the Process industry with broad workload coverage, calibration power and unsurpassed accuracy in mA measure and source for compatibility with HART instrumentation • Integrated pressure switch test allows you to...
... for certified RTD probes for enhanced temperature measurement. • New voltage input protection design for later analysis. The Fluke 726 Precision Multifunction Process Calibrator is designed specifically for the Process industry with broad workload coverage, calibration power and unsurpassed accuracy in mA measure and source for compatibility with HART instrumentation • Integrated pressure switch test allows you to...
Fluke 726 Process Calibrator Datasheet
Page 2
..., 1 mA 0.01 % Rdg + 2 LSD Max load, 1000 Ω 0.01 % of stackable test leads, product overview manual (print) and user's manual (CD-ROM) in14 languages. 2 Fluke Corporation 726 Precision Multifunction Process Calibrator Fluke. Keeping your world up and running. Printed in ) Weight: 650 g (23 oz) Battery: Four AA alkaline batteries Battery life: 25 hours typical Warranty: Three-years...
..., 1 mA 0.01 % Rdg + 2 LSD Max load, 1000 Ω 0.01 % of stackable test leads, product overview manual (print) and user's manual (CD-ROM) in14 languages. 2 Fluke Corporation 726 Precision Multifunction Process Calibrator Fluke. Keeping your world up and running. Printed in ) Weight: 650 g (23 oz) Battery: Four AA alkaline batteries Battery life: 25 hours typical Warranty: Three-years...
FE 726 Users Manual
Page 27
Voltage-to-Voltage Test bec39f.eps 17 Multifunction Process Calibrator Getting Started 726 PRECISION CALIBRATOR %Error V mA LOOP ZERO 3 Seconds OPEN/CLOSE STWEISTTCH MEAS SOURCE CONFIG SELECTION SAVE RECALL ENTER TRIGGER/STOP HART V mA TC RTD FREQ PULSE EXIT CONFIG 100% 25% 25% 0% Figure 6.
Voltage-to-Voltage Test bec39f.eps 17 Multifunction Process Calibrator Getting Started 726 PRECISION CALIBRATOR %Error V mA LOOP ZERO 3 Seconds OPEN/CLOSE STWEISTTCH MEAS SOURCE CONFIG SELECTION SAVE RECALL ENTER TRIGGER/STOP HART V mA TC RTD FREQ PULSE EXIT CONFIG 100% 25% 25% 0% Figure 6.
FE 726 Users Manual
Page 29
Multifunction Process Calibrator Using Measure Mode 726 PRECISION CALIBRATOR %Error V mA LOOP ZERO 3 Seconds OPEN/CLOSE SWITCH TEST MEAS SOURCE HART V mA TC RTD FREQ PULSE CONFIG SELECTION SAVE RECALL ENTER TRIGGER/STOP Return to Recall EXIT CONFIG 100% 25% 25% 0% Red HART Communicator TEST DC PWR - ++ - +- Black Figure 8. Connections for Supplying Loop Power bec18f.eps 19
Multifunction Process Calibrator Using Measure Mode 726 PRECISION CALIBRATOR %Error V mA LOOP ZERO 3 Seconds OPEN/CLOSE SWITCH TEST MEAS SOURCE HART V mA TC RTD FREQ PULSE CONFIG SELECTION SAVE RECALL ENTER TRIGGER/STOP Return to Recall EXIT CONFIG 100% 25% 25% 0% Red HART Communicator TEST DC PWR - ++ - +- Black Figure 8. Connections for Supplying Loop Power bec18f.eps 19
FE 726 Users Manual
Page 39
726 PRECISION CALIBRATOR %Error V mA LOOP ZERO 3 Seconds OPEN/CLOSE SWITCH TEST MEAS SOURCE HART V mA TC RTD FREQ PULSE CONFIG SELECTION SAVE RECALL ENTER TRIGGER/STOP Return to Recall EXIT CONFIG 100% 25% 25% 0% Multifunction Process Calibrator Using Measure Mode Gage Module Isolation Valve Differential Module L H Tank Figure 13. Connections for Measuring Pressure bec37f.eps 29
726 PRECISION CALIBRATOR %Error V mA LOOP ZERO 3 Seconds OPEN/CLOSE SWITCH TEST MEAS SOURCE HART V mA TC RTD FREQ PULSE CONFIG SELECTION SAVE RECALL ENTER TRIGGER/STOP Return to Recall EXIT CONFIG 100% 25% 25% 0% Multifunction Process Calibrator Using Measure Mode Gage Module Isolation Valve Differential Module L H Tank Figure 13. Connections for Measuring Pressure bec37f.eps 29
FE 726 Users Manual
Page 41
Connections for Simulating a 4- to Recall EXIT CONFIG 100% 25% 25% 0% Black - Figure 14. 726 PRECISION CALIBRATOR Multifunction Process Calibrator Using Source Mode Red + +24 V Loop Power Supply %Error V mA LOOP ZERO 3 Seconds OPEN/CLOSE SWITCH TEST MEAS SOURCE HART V mA TC RTD FREQ PULSE CONFIG SELECTION SAVE RECALL ENTER TRIGGER/STOP Return to 20-mA Transmitter Readout or Controller bec17f.eps 31
Connections for Simulating a 4- to Recall EXIT CONFIG 100% 25% 25% 0% Black - Figure 14. 726 PRECISION CALIBRATOR Multifunction Process Calibrator Using Source Mode Red + +24 V Loop Power Supply %Error V mA LOOP ZERO 3 Seconds OPEN/CLOSE SWITCH TEST MEAS SOURCE HART V mA TC RTD FREQ PULSE CONFIG SELECTION SAVE RECALL ENTER TRIGGER/STOP Return to 20-mA Transmitter Readout or Controller bec17f.eps 31
FE 726 Users Manual
Page 45
TC Miniplug Figure 16. Connections for Simulating a Thermocouple bec20f.eps 35 Multifunction Process Calibrator Using Source Mode 726 PRECISION CALIBRATOR %Error V mA LOOP ZERO 3 Seconds OPEN/CLOSE SWITCH TEST MEAS SOURCE HART V mA TC RTD FREQ PULSE CONFIG SELECTION SAVE RECALL ENTER TRIGGER/STOP Return to Recall EXIT CONFIG 100% 25% 25% 0% Color depends on type of TC TEST DC PWR - ++ +-
TC Miniplug Figure 16. Connections for Simulating a Thermocouple bec20f.eps 35 Multifunction Process Calibrator Using Source Mode 726 PRECISION CALIBRATOR %Error V mA LOOP ZERO 3 Seconds OPEN/CLOSE SWITCH TEST MEAS SOURCE HART V mA TC RTD FREQ PULSE CONFIG SELECTION SAVE RECALL ENTER TRIGGER/STOP Return to Recall EXIT CONFIG 100% 25% 25% 0% Color depends on type of TC TEST DC PWR - ++ +-
FE 726 Users Manual
Page 47
Connections for Simulating 3- and 4-Wire RTD bec40f.eps 37 Multifunction Process Calibrator Using Source Mode 726 PRECISION CALIBRATOR %Error V mA LOOP ZERO 3 Seconds OPEN/CLOSE SWITCH TEST MEAS SOURCE CONFIG SELECTION SAVE RECALL ENTER HART V mA TC RTD FREQ PULSE EXIT CONFIG 100% 25% TRIGGER/STOP 25% Return to 0% Recall RED 1 4 SENSOR TERMINALS 3 2 BLACK Figure 17.
Connections for Simulating 3- and 4-Wire RTD bec40f.eps 37 Multifunction Process Calibrator Using Source Mode 726 PRECISION CALIBRATOR %Error V mA LOOP ZERO 3 Seconds OPEN/CLOSE SWITCH TEST MEAS SOURCE CONFIG SELECTION SAVE RECALL ENTER HART V mA TC RTD FREQ PULSE EXIT CONFIG 100% 25% TRIGGER/STOP 25% Return to 0% Recall RED 1 4 SENSOR TERMINALS 3 2 BLACK Figure 17.