Fluke 726 Process Calibrator Datasheet
Page 2
... T, E, R, S, B, M, L, U, N, C, BP, XK RTD Ni120; Fluke Corporation PO Box 9090, Everett, WA USA 98206 Fluke Europe B.V. Pt100 (JIS); Squarewave, 1 CPM to10 kHz; Pt100, 200, 500, 1000 (385), Cu 10 Pressure (requires Fluke 700PXX Modules) Frequency; PO Box 1186, 5602 BD Eindhoven, The Netherlands For more ... in ) Weight: 650 g (23 oz) Battery: Four AA alkaline batteries Battery life: 25 hours typical Warranty: Three-years Ordering Information Fluke-726 Precision Multifunction Process Calibrator Included TL75 Test Leads, AC72 Test Clips, one pair of range + 1 LSD 0.015 % ± 0.05 ...
... T, E, R, S, B, M, L, U, N, C, BP, XK RTD Ni120; Fluke Corporation PO Box 9090, Everett, WA USA 98206 Fluke Europe B.V. Pt100 (JIS); Squarewave, 1 CPM to10 kHz; Pt100, 200, 500, 1000 (385), Cu 10 Pressure (requires Fluke 700PXX Modules) Frequency; PO Box 1186, 5602 BD Eindhoven, The Netherlands For more ... in ) Weight: 650 g (23 oz) Battery: Four AA alkaline batteries Battery life: 25 hours typical Warranty: Three-years Ordering Information Fluke-726 Precision Multifunction Process Calibrator Included TL75 Test Leads, AC72 Test Clips, one pair of range + 1 LSD 0.015 % ± 0.05 ...
FE 726 Users Manual
Page 12
..., cold junction compensation H2O to 10,000 psi 1-100,000 Freqency Max 10 kHz 1-10,000 Frequency Range 2 CPM to 4000 Ω Types E, J, K, T, B, R, S, L, U, N, C, XK, BP Pt100 Ω (385) Pt100 Ω (3926) Pt100 Ω (3916) Pt200 Ω (385) Pt500 Ω (385) Pt1000 Ω (385) Ni120 (672) CU10 29 modules ranging from 1.0 in...
..., cold junction compensation H2O to 10,000 psi 1-100,000 Freqency Max 10 kHz 1-10,000 Frequency Range 2 CPM to 4000 Ω Types E, J, K, T, B, R, S, L, U, N, C, XK, BP Pt100 Ω (385) Pt100 Ω (3926) Pt100 Ω (3916) Pt200 Ω (385) Pt500 Ω (385) Pt1000 Ω (385) Ni120 (672) CU10 29 modules ranging from 1.0 in...
FE 726 Users Manual
Page 35
... also designated as JIS curve. RTD Types Accepted RTD Type Ice Point (R ) 0 Material α Range (°C) Pt100 (3926) 100 Ω Platinum 0.003926 Ω/°C -200 to 630 Pt100 (385) 100 Ω Platinum 0.00385 Ω/°C -200 to 800 Ni120 (672) 120 Ω Nickel 0.... Ω Platinum 0.00385 Ω/°C -200 to 630 Pt1000 (385) 1000 Ω Platinum 0.00385 Ω/°C -200 to 630 Pt100 (3916) 100 Ω Platinum 0.003916 Ω/°C -200 to 630 The IEC standard RTD commonly used in U.S. Multifunction Process Calibrator Using Measure...
... also designated as JIS curve. RTD Types Accepted RTD Type Ice Point (R ) 0 Material α Range (°C) Pt100 (3926) 100 Ω Platinum 0.003926 Ω/°C -200 to 630 Pt100 (385) 100 Ω Platinum 0.00385 Ω/°C -200 to 800 Ni120 (672) 120 Ω Nickel 0.... Ω Platinum 0.00385 Ω/°C -200 to 630 Pt1000 (385) 1000 Ω Platinum 0.00385 Ω/°C -200 to 630 Pt100 (3916) 100 Ω Platinum 0.003916 Ω/°C -200 to 630 The IEC standard RTD commonly used in U.S. Multifunction Process Calibrator Using Measure...
FE 726 Users Manual
Page 73
... Accuracy Ni120 (672) -80.00 260.00 0.15 -200.00 100.00 0.15 100.00 300.00 0.25 Pt100 (385) 300.00 600.00 0.35 600.00 800.00 0.45 -200.00 100.00 0.15 Pt100 (3926) 100.00 300.00 0.25 300.00 630.00 0.35 -200.00 100.00 0.15... Pt100 (3916) 100.00 300.00 0.25 300.00 630.00 0.35 -200.00 100.00 0.75 Pt200 (385) 100...
... Accuracy Ni120 (672) -80.00 260.00 0.15 -200.00 100.00 0.15 100.00 300.00 0.25 Pt100 (385) 300.00 600.00 0.35 600.00 800.00 0.45 -200.00 100.00 0.15 Pt100 (3926) 100.00 300.00 0.25 300.00 630.00 0.35 -200.00 100.00 0.15... Pt100 (3916) 100.00 300.00 0.25 300.00 630.00 0.35 -200.00 100.00 0.75 Pt200 (385) 100...