FE 51 & 52 II Users Manual
Page 1
® 51 & 52 Series II Thermometer English September 1999 Rev.1, 6/01 © 1999-2001 Fluke Corporation, All rights reserved. Users Manual Printed in USA All product names are trademarks of their respective companies.
® 51 & 52 Series II Thermometer English September 1999 Rev.1, 6/01 © 1999-2001 Fluke Corporation, All rights reserved. Users Manual Printed in USA All product names are trademarks of their respective companies.
FE 51 & 52 II Users Manual
Page 4
51 & 52 Series II Users Manual Maintenance...13 Replacing the Batteries 13 Cleaning the Case and Holster 13 Calibration ...13 Specifications ...13 Environmental...13 General...14 80 PK-1 Thermocouple (supplied with thermometer 14 Electrical...14 Replacement Parts and Accessories 15 ii
51 & 52 Series II Users Manual Maintenance...13 Replacing the Batteries 13 Cleaning the Case and Holster 13 Calibration ...13 Specifications ...13 Environmental...13 General...14 80 PK-1 Thermocouple (supplied with thermometer 14 Electrical...14 Replacement Parts and Accessories 15 ii
FE 51 & 52 II Users Manual
Page 5
... this manual. Box 1186 5602 BD Eindhoven The Netherlands Visit us on the World Wide Web at: www.fluke.com To register your product, visit www.fluke-warranty.com 1 P.O. Box 9090 Everett, WA 98206-9090 USA Fluke Europe B.V. Use the thermometer only as temperature sensors. 51 & 52 Series II Introduction The Fluke Model 51 and Model 52 Thermometers ("the thermometer") are...
... this manual. Box 1186 5602 BD Eindhoven The Netherlands Visit us on the World Wide Web at: www.fluke.com To register your product, visit www.fluke-warranty.com 1 P.O. Box 9090 Everett, WA 98206-9090 USA Fluke Europe B.V. Use the thermometer only as temperature sensors. 51 & 52 Series II Introduction The Fluke Model 51 and Model 52 Thermometers ("the thermometer") are...
FE 51 & 52 II Users Manual
Page 6
... false readings can lead to personal injury. • Do not use the thermometer if it operates abnormally. Protection may be impaired. 51 & 52 Series II Users Manual Table 1. Pay particular attention to the user. When in doubt, have the thermometer serviced. • Do not operate the thermometer around the connectors. • Disconnect the thermocouple(s) from the...
... false readings can lead to personal injury. • Do not use the thermometer if it operates abnormally. Protection may be impaired. 51 & 52 Series II Users Manual Table 1. Pay particular attention to the user. When in doubt, have the thermometer serviced. • Do not operate the thermometer around the connectors. • Disconnect the thermocouple(s) from the...
FE 51 & 52 II Users Manual
Page 8
... 2 and Table 4 describe the display. • Table 5 describes the functions of the buttons. P Complies with relevant Canadian Standards Association directives. International Symbols W M Refer to Models 51 and 52 unless otherwise indicated. To become familiar with the thermometer, study the following sections. 4 51 & 52 Series II Users Manual Table 2.
... 2 and Table 4 describe the display. • Table 5 describes the functions of the buttons. P Complies with relevant Canadian Standards Association directives. International Symbols W M Refer to Models 51 and 52 unless otherwise indicated. To become familiar with the thermometer, study the following sections. 4 51 & 52 Series II Users Manual Table 2.
FE 51 & 52 II Users Manual
Page 14
Notes Setup is automatically disabled in MIN MAX mode. Line frequency: For optimum rejection of line noise, the thermometer must be set for T1 and T2. 51 & 52 Series II Users Manual Changing a Setup Option 1. The offset automatically resets to store the new setting in MIN MAX mode. Sleep mode becomes enabled each time you...
Notes Setup is automatically disabled in MIN MAX mode. Line frequency: For optimum rejection of line noise, the thermometer must be set for T1 and T2. 51 & 52 Series II Users Manual Changing a Setup Option 1. The offset automatically resets to store the new setting in MIN MAX mode. Sleep mode becomes enabled each time you...
FE 51 & 52 II Users Manual
Page 16
... shows H. 2. Press M to exit MIN MAX mode. Model 52: Press T to toggle showing the T1, T2, or T1-T2 readings in Setup to adjust the thermometer's readings to freeze the readings on the display. 2. Press G, M (CANCEL) to step through the maximum (MAX), minimum (MIN), or the average (AVG) readings. Plug the... the thermocouple in a known, stable temperature environment (such as an ice bath or a dry well calibrator). 3. Press h to compensate for the errors of a specific thermocouple. 51 & 52 Series II Users Manual Holding the Displayed Readings 1.
... shows H. 2. Press M to exit MIN MAX mode. Model 52: Press T to toggle showing the T1, T2, or T1-T2 readings in Setup to adjust the thermometer's readings to freeze the readings on the display. 2. Press G, M (CANCEL) to step through the maximum (MAX), minimum (MIN), or the average (AVG) readings. Plug the... the thermocouple in a known, stable temperature environment (such as an ice bath or a dry well calibrator). 3. Press h to compensate for the errors of a specific thermocouple. 51 & 52 Series II Users Manual Holding the Displayed Readings 1.
FE 51 & 52 II Users Manual
Page 17
...cleaner. Loosen the screw and remove the battery door. 3. Turn off the thermometer if necessary. 2. To calibrate the thermometer, contact Fluke for the Service Center nearest you calibrate the thermometer annually, starting one year after purchase. Replace the three AA batteries. 4. Specifications...Wipe with a damp sponge or soft rag. 51 & 52 Series II Maintenance Calibration To ensure that the thermometer performs to its accuracy specifications, Fluke recommends that you or follow the calibration procedure in the service manual listed in Table 1 before replacing the batteries. ...
...cleaner. Loosen the screw and remove the battery door. 3. Turn off the thermometer if necessary. 2. To calibrate the thermometer, contact Fluke for the Service Center nearest you calibrate the thermometer annually, starting one year after purchase. Replace the three AA batteries. 4. Specifications...Wipe with a damp sponge or soft rag. 51 & 52 Series II Maintenance Calibration To ensure that the thermometer performs to its accuracy specifications, Fluke recommends that you or follow the calibration procedure in the service manual listed in Table 1 before replacing the batteries. ...
FE 51 & 52 II Users Manual
Page 18
Example include protect electronic circuits. 80 PK-1 Thermocouple (supplied with thermometer) Type Temperature Range Accuracy Type K, Chromel Alumel, bead style −40 oC to +260 oC (−40 oF to +500 oF) ± 1.1... 1000o 1.0 oC / oF / K ≥ 1000o 14 Equipment of OVERVOLTAGE CATEGORY I , Pollution Degree 2 per IEC1010-1* * Refers to the level of Impulse Withstand Voltage protection provided. 51 & 52 Series II Users Manual General Weight 280 g (10 oz) Dimensions (without holster) 2.8 cm × 7.8 cm × 16.2 cm (1.1 in × 3 in × 6.4 in) Battery Certification...
Example include protect electronic circuits. 80 PK-1 Thermocouple (supplied with thermometer) Type Temperature Range Accuracy Type K, Chromel Alumel, bead style −40 oC to +260 oC (−40 oF to +500 oF) ± 1.1... 1000o 1.0 oC / oF / K ≥ 1000o 14 Equipment of OVERVOLTAGE CATEGORY I , Pollution Degree 2 per IEC1010-1* * Refers to the level of Impulse Withstand Voltage protection provided. 51 & 52 Series II Users Manual General Weight 280 g (10 oz) Dimensions (without holster) 2.8 cm × 7.8 cm × 16.2 cm (1.1 in × 3 in × 6.4 in) Battery Certification...