FE 51 & 52 II Users Manual
Page 1
Printed in USA All product names are trademarks of their respective companies. Users Manual ® 51 & 52 Series II Thermometer English September 1999 Rev.1, 6/01 © 1999-2001 Fluke Corporation, All rights reserved.
Printed in USA All product names are trademarks of their respective companies. Users Manual ® 51 & 52 Series II Thermometer English September 1999 Rev.1, 6/01 © 1999-2001 Fluke Corporation, All rights reserved.
FE 51 & 52 II Users Manual
Page 4
51 & 52 Series II Users Manual Maintenance...13 Replacing the Batteries 13 Cleaning the Case and Holster 13 Calibration ...13 Specifications ...13 Environmental...13 General...14 80 PK-1 Thermocouple (supplied with thermometer 14 Electrical...14 Replacement Parts and Accessories 15 ii
51 & 52 Series II Users Manual Maintenance...13 Replacing the Batteries 13 Cleaning the Case and Holster 13 Calibration ...13 Specifications ...13 Environmental...13 General...14 80 PK-1 Thermocouple (supplied with thermometer 14 Electrical...14 Replacement Parts and Accessories 15 ii
FE 51 & 52 II Users Manual
Page 5
...425-446-5500 from other countries Address correspondence to safety information in Table 1 and meter symbols in this manual. P.O. Refer to : Fluke Corporation P.O. Box 1186 5602 BD Eindhoven The Netherlands Visit us on the World Wide Web at: www....fluke.com To register your product, visit www.fluke-warranty.com 1 Box 9090 Everett, WA 98206-9090 USA Fluke Europe B.V. Otherwise, the protection provided by the meter may be impaired. 51 & 52 Series II Introduction The Fluke Model 51 and Model 52 Thermometers ("the thermometer") are microprocessor-based, digital thermometers designed...
...425-446-5500 from other countries Address correspondence to safety information in Table 1 and meter symbols in this manual. P.O. Refer to : Fluke Corporation P.O. Box 1186 5602 BD Eindhoven The Netherlands Visit us on the World Wide Web at: www....fluke.com To register your product, visit www.fluke-warranty.com 1 Box 9090 Everett, WA 98206-9090 USA Fluke Europe B.V. Otherwise, the protection provided by the meter may be impaired. 51 & 52 Series II Introduction The Fluke Model 51 and Model 52 Thermometers ("the thermometer") are microprocessor-based, digital thermometers designed...
FE 51 & 52 II Users Manual
Page 6
...be impaired. To avoid electrical shock or personal injury, follow these guidelines: • Before using the thermometer inspect the case. Look for cracks or missing plastic. Safety Information WWarning A Warning identifies conditions and ...thermometer serviced. • Do not operate the thermometer around the connectors. • Disconnect the thermocouple(s) from the thermometer before opening the case. • Replace the batteries as soon as marked on the thermometer, between the thermocouple(s), or between any thermocouple and earth ground. 2 51 & 52 Series II Users Manual...
...be impaired. To avoid electrical shock or personal injury, follow these guidelines: • Before using the thermometer inspect the case. Look for cracks or missing plastic. Safety Information WWarning A Warning identifies conditions and ...thermometer serviced. • Do not operate the thermometer around the connectors. • Disconnect the thermocouple(s) from the thermometer before opening the case. • Replace the batteries as soon as marked on the thermometer, between the thermocouple(s), or between any thermocouple and earth ground. 2 51 & 52 Series II Users Manual...
FE 51 & 52 II Users Manual
Page 8
51 & 52 Series II Users Manual Table 2. Battery. To become familiar with relevant Canadian Standards Association directives. Complies with the thermometer, study the following sections. 4 Then read the following : • Figure 1 and Table 3 describe the components. • Figure 2 and Table 4 describe the display. • Table 5 describes ...
51 & 52 Series II Users Manual Table 2. Battery. To become familiar with relevant Canadian Standards Association directives. Complies with the thermometer, study the following sections. 4 Then read the following : • Figure 1 and Table 3 describe the components. • Figure 2 and Table 4 describe the display. • Table 5 describes ...
FE 51 & 52 II Users Manual
Page 14
51 & 52 Series II Users Manual Changing a Setup Option 1. Press K or N until the setting you turn on the display. 4. Remember to reset the offset to 0.0 when it to change. 2. Model 52: ... want to change the thermocouple type. The offset automatically resets to 0.0 when you want to use appears on the thermometer and is automatically disabled in MIN MAX mode. Pressing any button wakes the thermometer and returns it is disabled in memory. Press E to the setup option you change this setting. 3. Offset: The...
51 & 52 Series II Users Manual Changing a Setup Option 1. Press K or N until the setting you turn on the display. 4. Remember to reset the offset to 0.0 when it to change. 2. Model 52: ... want to change the thermocouple type. The offset automatically resets to 0.0 when you want to use appears on the thermometer and is automatically disabled in MIN MAX mode. Pressing any button wakes the thermometer and returns it is disabled in memory. Press E to the setup option you change this setting. 3. Offset: The...
FE 51 & 52 II Users Manual
Page 16
.... 3. The allowable adjustment range is ± 5.0 oC or K, and ± 9.0 oF. 1. Place the thermocouple in Setup to adjust the thermometer's readings to stabilize. 4. In Setup change the offset until the primary display reading matches the calibration temperature. (See "Changing Setup Options.") 12 The ... into the input connector. 2. Press h again to exit MIN MAX mode. Viewing the MIN, MAX, and AVG Readings 1. 51 & 52 Series II Users Manual Holding the Displayed Readings 1. Allow the readings to compensate for the errors of a specific thermocouple. Using the Offset to Adjust for...
.... 3. The allowable adjustment range is ± 5.0 oC or K, and ± 9.0 oF. 1. Place the thermocouple in Setup to adjust the thermometer's readings to stabilize. 4. In Setup change the offset until the primary display reading matches the calibration temperature. (See "Changing Setup Options.") 12 The ... into the input connector. 2. Press h again to exit MIN MAX mode. Viewing the MIN, MAX, and AVG Readings 1. 51 & 52 Series II Users Manual Holding the Displayed Readings 1. Allow the readings to compensate for the errors of a specific thermocouple. Using the Offset to Adjust for...
FE 51 & 52 II Users Manual
Page 17
... oC Temperature (−40 oF to its accuracy specifications, Fluke recommends that the thermometer performs to +140 oF) Humidity Non condensing Wipe with a damp sponge or soft rag. 51 & 52 Series II Maintenance Calibration To ensure that you or... follow the calibration procedure in the service manual listed in Table 1 before replacing the batteries. 1. Replace the three AA batteries. 4. Cleaning the Case and Holster Use soap and water or a mild commercial cleaner. To calibrate the thermometer, contact Fluke...
... oC Temperature (−40 oF to its accuracy specifications, Fluke recommends that the thermometer performs to +140 oF) Humidity Non condensing Wipe with a damp sponge or soft rag. 51 & 52 Series II Maintenance Calibration To ensure that you or... follow the calibration procedure in the service manual listed in Table 1 before replacing the batteries. 1. Replace the three AA batteries. 4. Cleaning the Case and Holster Use soap and water or a mild commercial cleaner. To calibrate the thermometer, contact Fluke...
FE 51 & 52 II Users Manual
Page 18
...Degree 2 per IEC1010-1* * Refers to the level of Impulse Withstand Voltage protection provided. Example include protect electronic circuits. 80 PK-1 Thermocouple (supplied with thermometer) Type Temperature Range Accuracy Type K, Chromel Alumel, bead style −40 oC to +260 oC (−40 oF to +500 oF) ± ...8722;150 oC to +1000 oC (−238 oF to +1832 oF) 0.1 oC / oF / K < 1000o 1.0 oC / oF / K ≥ 1000o 14 51 & 52 Series II Users Manual General Weight 280 g (10 oz) Dimensions (without holster) 2.8 cm × 7.8 cm × 16.2 cm (1.1 in × 3 in × 6.4 in ...
...Degree 2 per IEC1010-1* * Refers to the level of Impulse Withstand Voltage protection provided. Example include protect electronic circuits. 80 PK-1 Thermocouple (supplied with thermometer) Type Temperature Range Accuracy Type K, Chromel Alumel, bead style −40 oC to +260 oC (−40 oF to +500 oF) ± ...8722;150 oC to +1000 oC (−238 oF to +1832 oF) 0.1 oC / oF / K < 1000o 1.0 oC / oF / K ≥ 1000o 14 51 & 52 Series II Users Manual General Weight 280 g (10 oz) Dimensions (without holster) 2.8 cm × 7.8 cm × 16.2 cm (1.1 in × 3 in × 6.4 in ...