Fluke 381 Users Manual
Page 1
Printed in China. Specifications are trademarks of their respective companies. All product names are subject to change without notice. 381 Remote Display True-rms Clamp Meter Users Manual PN 3538357 July 2010 © 2010 Fluke Corporation. All rights reserved.
Printed in China. Specifications are trademarks of their respective companies. All product names are subject to change without notice. 381 Remote Display True-rms Clamp Meter Users Manual PN 3538357 July 2010 © 2010 Fluke Corporation. All rights reserved.
Fluke 381 Users Manual
Page 9
Important information. See Manual. ) Conforms to Fluke's website for recycling information. 5 Low battery when shown. Go to relevant North American Safety Standards. X Hazardous voltage P Conforms to European Union directives. W Risk of this product as unsorted municipal waste. Symbols Symbol B F Meaning AC (Alternating Current) DC (Direct Current) Symbol J P Meaning Earth ground AC and dc current. Remote Display True-rms Clamp Meter Safety Information Table 1. T Double insulated ~ Do not dispose of Danger. B Battery.
Important information. See Manual. ) Conforms to Fluke's website for recycling information. 5 Low battery when shown. Go to relevant North American Safety Standards. X Hazardous voltage P Conforms to European Union directives. W Risk of this product as unsorted municipal waste. Symbols Symbol B F Meaning AC (Alternating Current) DC (Direct Current) Symbol J P Meaning Earth ground AC and dc current. Remote Display True-rms Clamp Meter Safety Information Table 1. T Double insulated ~ Do not dispose of Danger. B Battery.
Fluke 381 Users Manual
Page 10
...and lighting systems in fixed-equipment installations, such as an electricity Meter or an overhead or underground utility service. ® Examined and licensed by TÜV Product Services. ; 381 Users Manual Symbol Meaning Symbol Meaning CAT III IEC Measurement Category III CAT ...III equipment has protection against transients from HAZARDOUS LIVE conductors is the LOWEST rating of test probe, test probe accessory, current clamp accessory, and the Meter is permitted....
...and lighting systems in fixed-equipment installations, such as an electricity Meter or an overhead or underground utility service. ® Examined and licensed by TÜV Product Services. ; 381 Users Manual Symbol Meaning Symbol Meaning CAT III IEC Measurement Category III CAT ...III equipment has protection against transients from HAZARDOUS LIVE conductors is the LOWEST rating of test probe, test probe accessory, current clamp accessory, and the Meter is permitted....
Fluke 381 Users Manual
Page 24
... Release and insert the conductor into the clamp at a time. If current is no conductor inside the Jaw. See Figure 4. Note When the measured current is coming from the Jaw. See Figure 4. 20 View the reading on and off. 381 Users Manual Note Before zeroing the Meter, make sure the Jaws are closed and...
... Release and insert the conductor into the clamp at a time. If current is no conductor inside the Jaw. See Figure 4. Note When the measured current is coming from the Jaw. See Figure 4. 20 View the reading on and off. 381 Users Manual Note Before zeroing the Meter, make sure the Jaws are closed and...
Fluke 381 Users Manual
Page 35
Meter Base 1 3766406 Fluke 381 Remote Display 1 3766445 Soft Case 1 3752973 User Manual 1 3538357 31 Display Module 1 3625529 Battery Door - User-Replaceable Parts Description Qty. Fluke Part Number Battery, AAA 1.5 V 5 2838018 Battery Door - Remote Display True-rms Clamp Meter User-Replaceable Parts User-Replaceable Parts Table 5.
Meter Base 1 3766406 Fluke 381 Remote Display 1 3766445 Soft Case 1 3752973 User Manual 1 3538357 31 Display Module 1 3625529 Battery Door - User-Replaceable Parts Description Qty. Fluke Part Number Battery, AAA 1.5 V 5 2838018 Battery Door - Remote Display True-rms Clamp Meter User-Replaceable Parts User-Replaceable Parts Table 5.