Fluke 375 and 374 Clamp Meter Product Datasheet
Page 2
... so you do not need to change switch positions while taking a measurement • Three-year warranty • Soft carrying case Specifications Fluke 374 and 375 AC current via jaw AC current via iFlex™ (optional) DC current AC voltage DC voltage Resistance Frequency (375 ...600 V Models Old model: Fluke 337 New model: Fluke 376 Old model: Fluke 336 New model: Fluke 375 New model: Fluke 374 Old model: Fluke 335 New model: Fluke 374 New model: Fluke 373 Old model: Fluke 334 New model: Fluke 374 New model: Fluke 373 Old model: Fluke 333 New model: Fluke 373 Feature Changes Includes all 337...
... so you do not need to change switch positions while taking a measurement • Three-year warranty • Soft carrying case Specifications Fluke 374 and 375 AC current via jaw AC current via iFlex™ (optional) DC current AC voltage DC voltage Resistance Frequency (375 ...600 V Models Old model: Fluke 337 New model: Fluke 376 Old model: Fluke 336 New model: Fluke 375 New model: Fluke 374 Old model: Fluke 335 New model: Fluke 374 New model: Fluke 373 Old model: Fluke 334 New model: Fluke 374 New model: Fluke 373 Old model: Fluke 333 New model: Fluke 373 Feature Changes Includes all 337...
Fluke 374, 375, 376 Users Manual
Page 1
All product names are subject to change without notice. Specifications are trademarks of their respective companies. All rights reserved. Printed in China. 374/375/376 Clamp Meter Users Manual PN 3608883 July 2010 © 2010 Fluke Corporation.
All product names are subject to change without notice. Specifications are trademarks of their respective companies. All rights reserved. Printed in China. 374/375/376 Clamp Meter Users Manual PN 3608883 July 2010 © 2010 Fluke Corporation.
Fluke 374, 375, 376 Users Manual
Page 3
Table of Contents Title Page Introduction...1 How to Contact Fluke 2 Safety Information ...3 The Meter ...9 Specifications ...19 Electrical Specifications 19 Mechanical Specifications 26 Environmental Specifications 27 i
Table of Contents Title Page Introduction...1 How to Contact Fluke 2 Safety Information ...3 The Meter ...9 Specifications ...19 Electrical Specifications 19 Mechanical Specifications 26 Environmental Specifications 27 i
Fluke 374, 375, 376 Users Manual
Page 23
Specifications Electrical Specifications AC Current via Jaw Range 374 and 375 600.0 A 376 999.9 A Resolution 0.1 A Accuracy 2 % ± 5 digits (10-100 Hz) 2.5 % ± 5 digits (100-500 Hz) Crest Factor (50/60 Hz 3 @ 500 A (375 and 376 only) 2.5 @ 600 A 1.42 @1000 A (376 only) Add 2 % for C.F. > 2 Clamp Meters Specifications 19
Specifications Electrical Specifications AC Current via Jaw Range 374 and 375 600.0 A 376 999.9 A Resolution 0.1 A Accuracy 2 % ± 5 digits (10-100 Hz) 2.5 % ± 5 digits (100-500 Hz) Crest Factor (50/60 Hz 3 @ 500 A (375 and 376 only) 2.5 @ 600 A 1.42 @1000 A (376 only) Add 2 % for C.F. > 2 Clamp Meters Specifications 19
Fluke 374, 375, 376 Users Manual
Page 27
374 and 375 600.0 V 376 1000 V Resolution 374 and 375 0.1 V 376 0.1 V (≤ 600.0 V) 1 V (≤ 1000 V) Accuracy 1.5 % ± 5 digits (20 - 500 Hz) DC Voltage Range 374 and 375 600.0 V 376 1000 V Clamp Meters Specifications 23
374 and 375 600.0 V 376 1000 V Resolution 374 and 375 0.1 V 376 0.1 V (≤ 600.0 V) 1 V (≤ 1000 V) Accuracy 1.5 % ± 5 digits (20 - 500 Hz) DC Voltage Range 374 and 375 600.0 V 376 1000 V Clamp Meters Specifications 23
Fluke 374, 375, 376 Users Manual
Page 30
374, 375, 376 Users Manual Resolution 374 0.1 Ω (≤ 600 Ω) 1 Ω (≤ 6000 Ω) 375 and 376 0.1 Ω (≤ 600 Ω) 1 Ω (≤ 6000 Ω) 10 Ω (≤ 60 kΩ) Accuracy 1 % ± 5 digits Capacitance Range 1000 μF Resolution 0.1 μF (≤ 100 μF) 1 μ F (≤ 1000 μF) Accuracy 1 % ± 4 digits Mechanical Specifications Size (L x W x H 246 mm x 83 m x 43 mm Weight 388 g Jaw Opening 34 mm 26
374, 375, 376 Users Manual Resolution 374 0.1 Ω (≤ 600 Ω) 1 Ω (≤ 6000 Ω) 375 and 376 0.1 Ω (≤ 600 Ω) 1 Ω (≤ 6000 Ω) 10 Ω (≤ 60 kΩ) Accuracy 1 % ± 5 digits Capacitance Range 1000 μF Resolution 0.1 μF (≤ 100 μF) 1 μ F (≤ 1000 μF) Accuracy 1 % ± 4 digits Mechanical Specifications Size (L x W x H 246 mm x 83 m x 43 mm Weight 388 g Jaw Opening 34 mm 26
Fluke 374, 375, 376 Users Manual
Page 31
... Current Probe Diameter 7.5 mm Flexible Current Probe Cable Length (head to electronics connector 1.8 m Environmental Specifications Operating Temperature 10 °C - +50 °C Storage Temp 40 °C - +60 °C Operating Humidity Non condensing (< 10 - °C) ≤ 90 % RH (at 10 °C - 30 ...
... Current Probe Diameter 7.5 mm Flexible Current Probe Cable Length (head to electronics connector 1.8 m Environmental Specifications Operating Temperature 10 °C - +50 °C Storage Temp 40 °C - +60 °C Operating Humidity Non condensing (< 10 - °C) ≤ 90 % RH (at 10 °C - 30 ...
Fluke 374, 375, 376 Users Manual
Page 32
374, 375, 376 Users Manual Safety Specifications Safety Compliance CAN/CSA-C22.2 No. 61010-1-04 ANSI/UL 61010-1:2004 ANSI/ISA-61010-1 (82.02.01):2004 EN/IEC 61010-1:2001 to 1000V Measurement Category (CAT) III 600V Measurement Category (CAT) IV Pollution Degree 2 EN/IEC 61010-2-032:2002 EN/IEC 61010-031:2002+A1:2008 P Agency Approvals Batteries 2 AA, NEDA 15A, IEC LR6 28
374, 375, 376 Users Manual Safety Specifications Safety Compliance CAN/CSA-C22.2 No. 61010-1-04 ANSI/UL 61010-1:2004 ANSI/ISA-61010-1 (82.02.01):2004 EN/IEC 61010-1:2001 to 1000V Measurement Category (CAT) III 600V Measurement Category (CAT) IV Pollution Degree 2 EN/IEC 61010-2-032:2002 EN/IEC 61010-031:2002+A1:2008 P Agency Approvals Batteries 2 AA, NEDA 15A, IEC LR6 28