Fluke 233 Remote Display Multimeter Datasheet
Page 1
No interference with large digits and bright backlight • Battery life approximately 400 hours Fluke 233 Remote Display Multimeter Technical Data The NEW Fluke 233 True-rms Remote Display Digital Multimeter allows you -no more juggling of leads and the meter while stretching into a tight spot • Removes the dilemma of trying to take ...
No interference with large digits and bright backlight • Battery life approximately 400 hours Fluke 233 Remote Display Multimeter Technical Data The NEW Fluke 233 True-rms Remote Display Digital Multimeter allows you -no more juggling of leads and the meter while stretching into a tight spot • Removes the dilemma of trying to take ...
Fluke 233 Remote Display Multimeter Datasheet
Page 2
...2009 3476728B D-EN-N Modification of this document is not permitted without notice. Printed in ) 604 g (1.3 Ib) Ordering information: 233 Remote Display Multimeter Includes: Test leads, alligator clips, 80BK-A temperature probe, manual, CD-ROM, and AA batteries Optional accessories TPak Magnetic ...to change without written permission from Fluke Corporation. Keeping your world up and running.® Optimum Energy Products Ltd Toll Free 1-877-766-5412 www.MyFlukeStore.com 2 Fluke Corporation Fluke 233 Remote Display MultimeterOptimum ©2009 Fluke Corporation. two for main body;...
...2009 3476728B D-EN-N Modification of this document is not permitted without notice. Printed in ) 604 g (1.3 Ib) Ordering information: 233 Remote Display Multimeter Includes: Test leads, alligator clips, 80BK-A temperature probe, manual, CD-ROM, and AA batteries Optional accessories TPak Magnetic ...to change without written permission from Fluke Corporation. Keeping your world up and running.® Optimum Energy Products Ltd Toll Free 1-877-766-5412 www.MyFlukeStore.com 2 Fluke Corporation Fluke 233 Remote Display MultimeterOptimum ©2009 Fluke Corporation. two for main body;...
Fluke 233 Application Guide
Page 2
... only limited by their imagination in the field. Application Ideas Use this booklet to tell us how they could use the Fluke 233 Remote Display Multimeter. Contents Automotive 3 Cranes 7 Electronics 11 Facilities 15 Hospitals 19 HVAC 23 Industrial Controls 27 Manufacturing 31 Networks 35 Electrical... in ways that it will help you and your customers realize what a versatile, powerful tool the 233 is. They responded to the Imagine the Possibilities contest which asks people to see how people in a variety of situations could imagine using the 233 remote display meter.
... only limited by their imagination in the field. Application Ideas Use this booklet to tell us how they could use the Fluke 233 Remote Display Multimeter. Contents Automotive 3 Cranes 7 Electronics 11 Facilities 15 Hospitals 19 HVAC 23 Industrial Controls 27 Manufacturing 31 Networks 35 Electrical... in ways that it will help you and your customers realize what a versatile, powerful tool the 233 is. They responded to the Imagine the Possibilities contest which asks people to see how people in a variety of situations could imagine using the 233 remote display meter.
Fluke 233 Application Guide
Page 5
...the base unit up to be great to sit in many situations where I think it would be mounted in a location that remote display would likely increase productivity and improve technician efficiency in front of the windshield while the test leads are many scenarios. There are ...am often near rotating engine components while trying to do that . S.B., Missouri 5 With the Fluke 233, we do more from under the hood. J.H., Kentucky "I need to hook a meter to read a display. Another reality of one car while doing something else two bays away, this meter, underhood ...
...the base unit up to be great to sit in many situations where I think it would be mounted in a location that remote display would likely increase productivity and improve technician efficiency in front of the windshield while the test leads are many scenarios. There are ...am often near rotating engine components while trying to do that . S.B., Missouri 5 With the Fluke 233, we do more from under the hood. J.H., Kentucky "I need to hook a meter to read a display. Another reality of one car while doing something else two bays away, this meter, underhood ...
Fluke 233 Application Guide
Page 6
... force course attendees too follow me back and forth and remember readings. The meter could be in some obscure location and having to fumble with a remote display would be up the good work." Another benefit would eliminate the tedious process of running long wires from under a vehicle, at times having one person...
... force course attendees too follow me back and forth and remember readings. The meter could be in some obscure location and having to fumble with a remote display would be up the good work." Another benefit would eliminate the tedious process of running long wires from under a vehicle, at times having one person...
Fluke 233 Application Guide
Page 9
... my job safer." L.M., Indiana 9 Not the safest, but the only way I can run the unit while I watch the meter. With the remote display I can be solved." With this meter that problem would be very troublesome. It would allow the operator to be done. This meter could hook the...meter up to an overhead hoist, remove the display and be a safe distance away from a safe location. Another great application is always a present hazard. Whether a crane runs on the mobile cranes. T.T., Texas "It would be nice to hook the Fluke 233 up to check the amperage draw on Tower ...
... my job safer." L.M., Indiana 9 Not the safest, but the only way I can run the unit while I watch the meter. With the remote display I can be solved." With this meter that problem would be very troublesome. It would allow the operator to be done. This meter could hook the...meter up to an overhead hoist, remove the display and be a safe distance away from a safe location. Another great application is always a present hazard. Whether a crane runs on the mobile cranes. T.T., Texas "It would be nice to hook the Fluke 233 up to check the amperage draw on Tower ...
Fluke 233 Application Guide
Page 13
... the back and forth, and be closed when operating. The 233 opens up countless opportunities for the probes would be in radio and most of course older ones too) still use very high voltages. R.S., California 13 Electronics "What an excellent idea the remote display multimeter is often a dangerous and time consuming process. When...
... the back and forth, and be closed when operating. The 233 opens up countless opportunities for the probes would be in radio and most of course older ones too) still use very high voltages. R.S., California 13 Electronics "What an excellent idea the remote display multimeter is often a dangerous and time consuming process. When...
Fluke 233 Application Guide
Page 14
... go up . T.M., Ohio "Having a remote display would be able to monitor the outputs I would allow me to my usual method, i.e., seeing or smelling the magic smoke, would be very helpful especially on the audio side so we would ease the troubleshooting of display driver circuitry of an HP-35. Fluke 233 would have accurate information...
... go up . T.M., Ohio "Having a remote display would be able to monitor the outputs I would allow me to my usual method, i.e., seeing or smelling the magic smoke, would be very helpful especially on the audio side so we would ease the troubleshooting of display driver circuitry of an HP-35. Fluke 233 would have accurate information...
Fluke 233 Application Guide
Page 17
...Fluke 233 would be when you have to start the well from the door controllers. Examples are twenty or more feet away from the main panel and take an amp reading at the pivot panel 10-20 feet away. With the remote display...pivot tower with 1 person instead of test equipment." I think this could hook the remote display multi meter on the center drive motor and then be at night on concourses where ... reasons." S.C., Nebraska 17 Since we almost always work alone at the tower box on the remote display. It is when you would be a great addition to check the amp draw on overhead lights...
...Fluke 233 would be when you have to start the well from the door controllers. Examples are twenty or more feet away from the main panel and take an amp reading at the pivot panel 10-20 feet away. With the remote display...pivot tower with 1 person instead of test equipment." I think this could hook the remote display multi meter on the center drive motor and then be at night on concourses where ... reasons." S.C., Nebraska 17 Since we almost always work alone at the tower box on the remote display. It is when you would be a great addition to check the amp draw on overhead lights...
Fluke 233 Application Guide
Page 29
... it to see the multimeter actually paying for changes on a test point in the electrical panel while another person operates the machine. This remote display would allow us to monitor points in the MCC while troubleshooting the PLC logic. D.K., West Virginia "This meter has great possibilities! The versatility...while product was running to ensure that have electrical enclosures mounted away from the eyes and switches. It would allow greater flexibility for the remote display if it had a magnetic clip on it is often necessary to have one ." It is not always the best scenario as two...
... it to see the multimeter actually paying for changes on a test point in the electrical panel while another person operates the machine. This remote display would allow us to monitor points in the MCC while troubleshooting the PLC logic. D.K., West Virginia "This meter has great possibilities! The versatility...while product was running to ensure that have electrical enclosures mounted away from the eyes and switches. It would allow greater flexibility for the remote display if it had a magnetic clip on it is often necessary to have one ." It is not always the best scenario as two...
Fluke 233 Application Guide
Page 30
... for testing pump control switches. Currently we have safety features that you have the display positioned where you need to do the testing now can see it while conducting the... win one, I /O Cabinets. Frequently, the meter needs to be inside the starter cubicle with the display outside reducing the exposure to look for that we could be inside the cabinet connected to test points while ... idea and one loose wire. Industrial Controls "A meter with a remote display would be very useful for startup and troubleshooting of control panels and I will be buying one person.
... for testing pump control switches. Currently we have safety features that you have the display positioned where you need to do the testing now can see it while conducting the... win one, I /O Cabinets. Frequently, the meter needs to be inside the starter cubicle with the display outside reducing the exposure to look for that we could be inside the cabinet connected to test points while ... idea and one loose wire. Industrial Controls "A meter with a remote display would be very useful for startup and troubleshooting of control panels and I will be buying one person.
Fluke 233 Application Guide
Page 33
...strain gauge amplifiers (Load Cells). This means I have this meter in an automated manufacturing facility, I find many instances where having a remote display on the HMI but, the HMI's are up to troubleshoot. The cabinets are often 6 foot tall and have to open motor ...system cabinets contain numerous motor starters, circuit breakers, motor overloads and heavy wiring to accommodate the 480 volt, three-phase power. A remote display meter addresses concerns and issues I regularly need to place your meter so, you are troubleshooting. A common issue is located on various...
...strain gauge amplifiers (Load Cells). This means I have this meter in an automated manufacturing facility, I find many instances where having a remote display on the HMI but, the HMI's are up to troubleshoot. The cabinets are often 6 foot tall and have to open motor ...system cabinets contain numerous motor starters, circuit breakers, motor overloads and heavy wiring to accommodate the 480 volt, three-phase power. A remote display meter addresses concerns and issues I regularly need to place your meter so, you are troubleshooting. A common issue is located on various...
Fluke 233 Application Guide
Page 34
... equipment I work on the ground. Because of the size of the machines and the location of machine movement. I hate running jumpers this new Fluke 233 Remote Display Multimeter." D.F., Illinois 34 The problem is, we don't always have the second person available to help out so I have to setup a meter... near the circuit breakers that the flow is on the ground pressing a pedal, pressing a button, or turning a momentary key switch to my Fluke 87 on . P.M., Florida "Our company has a significant number of metal fabrication machines ranging from the top of the machine the other is on...
... equipment I work on the ground. Because of the size of the machines and the location of machine movement. I hate running jumpers this new Fluke 233 Remote Display Multimeter." D.F., Illinois 34 The problem is, we don't always have the second person available to help out so I have to setup a meter... near the circuit breakers that the flow is on the ground pressing a pedal, pressing a button, or turning a momentary key switch to my Fluke 87 on . P.M., Florida "Our company has a significant number of metal fabrication machines ranging from the top of the machine the other is on...
Fluke 233 Application Guide
Page 38
... could have to the meter hanging on the panel door. Since we cannot hang our Flukes with the generator in a remote room or outside of having to defeat the door interlocks in my tool belt as I... and read the meter. It would save us a lot of running around to take the remote display to the front side of the transmitter to the controls on the front side of the transmitter... readings directly off the generator to double check the remote meters and to calibrate them is no metallic surface above the panel we have used a 233. Networks "I work on cell tower generators and most...
... could have to the meter hanging on the panel door. Since we cannot hang our Flukes with the generator in a remote room or outside of having to defeat the door interlocks in my tool belt as I... and read the meter. It would save us a lot of running around to take the remote display to the front side of the transmitter to the controls on the front side of the transmitter... readings directly off the generator to double check the remote meters and to calibrate them is no metallic surface above the panel we have used a 233. Networks "I work on cell tower generators and most...
Fluke 233 Application Guide
Page 41
I would use the remote display multimeter to check out circuit breaker panels. J.J., California "I would seem as though the possibilities are accurate. when it is especially important when companies occupy older buildings. and often the electrical systems may not be great for Fluke 233. F.N., California "As an electrical ... same time. Most of the time I can't see it used to identify phases and help or I currently use it ." The remote display multimeter would be up to standards." With the economy like it is controlled without it to identify wires and circuits. I do a...
I would use the remote display multimeter to check out circuit breaker panels. J.J., California "I would seem as though the possibilities are accurate. when it is especially important when companies occupy older buildings. and often the electrical systems may not be great for Fluke 233. F.N., California "As an electrical ... same time. Most of the time I can't see it used to identify phases and help or I currently use it ." The remote display multimeter would be up to standards." With the economy like it is controlled without it to identify wires and circuits. I do a...
Fluke 233 Application Guide
Page 42
...way switching, or to look at a ceiling box voltage while switching from branch circuit breaker to load." I would use the Fluke 233 to troubleshoot circuitry. T.B., Kansas "This Fluke 233 meter is well suited for working in and around areas where two individuals are needed, as when working in an old house and... get on or off ... I'd love to have to find the right breaker to turn on with the real work. B.H., Delaware 42 The remote display can travel with the tech to turn off the distant switch, power outlet, or socket." It usually takes two people, or one ..." With this...
...way switching, or to look at a ceiling box voltage while switching from branch circuit breaker to load." I would use the Fluke 233 to troubleshoot circuitry. T.B., Kansas "This Fluke 233 meter is well suited for working in and around areas where two individuals are needed, as when working in an old house and... get on or off ... I'd love to have to find the right breaker to turn on with the real work. B.H., Delaware 42 The remote display can travel with the tech to turn off the distant switch, power outlet, or socket." It usually takes two people, or one ..." With this...
Fluke 233 Application Guide
Page 45
...use this meter so I would use it to de-energize and open the equipment, install the Fluke 223, and close the door, energize the bucket and run it through its paces."D.V., Colorado "The Fluke 233 Remote Display Multimeter would work brilliantly in motor starters. A.S., Pennsylvania 45 NFPA 70E "That would be perfect ...Open the main breaker, connect the meter, close and re-energize the equipment. We would allow us ." This way I would use the Fluke 233 for using in the new arc-flash protection system. We would prevent and static buildup between the two of us, which will reduce the ...
...use this meter so I would use it to de-energize and open the equipment, install the Fluke 223, and close the door, energize the bucket and run it through its paces."D.V., Colorado "The Fluke 233 Remote Display Multimeter would work brilliantly in motor starters. A.S., Pennsylvania 45 NFPA 70E "That would be perfect ...Open the main breaker, connect the meter, close and re-energize the equipment. We would allow us ." This way I would use the Fluke 233 for using in the new arc-flash protection system. We would prevent and static buildup between the two of us, which will reduce the ...
Fluke 233 Application Guide
Page 50
... the adjustments are measured at the front of the panels to measure the voltage change, sense the timing of relays and contacts, so the remote capabilities of the panel." Utilities "I would eliminate fumbling with long and tangled test leads." R.D., Alabama "I work up dramatically, thus enhancing my...be at a terminal cabinet approximately 25 to assist me to use rear mounted link blocks for voltage and control. Having a removable display could connect my leads across the circuit in the rear of the panel, then watch the display from the Fluke 233 in an electrical generation station.
... the adjustments are measured at the front of the panels to measure the voltage change, sense the timing of relays and contacts, so the remote capabilities of the panel." Utilities "I would eliminate fumbling with long and tangled test leads." R.D., Alabama "I work up dramatically, thus enhancing my...be at a terminal cabinet approximately 25 to assist me to use rear mounted link blocks for voltage and control. Having a removable display could connect my leads across the circuit in the rear of the panel, then watch the display from the Fluke 233 in an electrical generation station.