Fluke 192, 196, and 199 Scopemeter Datasheet - Page 1
...; 1000 V CAT II and 600 V CAT III safety certified • Five hours rechargeable Ni-MH battery pack
In Trendplot or "paperless recorder" mode, you can be
B/W with the highest resolution and detail. FLUKE-192B/003S ScopeMeter 60 MHz
to specific
Cursors can
Waveform Pass/Fail testing
simultaneously acquire two waveforms and analyze them with SCC kit...
FE 192,196,199 C Users Manual - Page 73
... to the general functions of this chapter. Saving and Recalling
You can be used in the three main modes: Scope, Meter, or Recorder. The test tool has 10 screen and setup memories and 2 record and setup memories.
• Recall screens and recordings to analyze or print the screen image at the end of the...
FE 192,196,199 C Users Manual - Page 74
....
Filled memory
locations are indicated by a solid square ().
3
Highlight SCREEN+SETUP location 10.
4
Save the actual screen.
In TrendPlot or scope record mode the full recording is just visible on the screen. Fluke 192B - 196B/C - 199B/C Users Manual
Saving Screens with Associated Setups
To save all 100 replay screens in memory location 10, do...
FE 192,196,199 C Users Manual - Page 78
Connecting a Parallel Printer Fluke 192B - 196B/C - 199B/C Users Manual
Note For information about installing and using the FlukeView ScopeMeter software, see the SW90W Users Manual. A Software & Cable Carrying Case Kit is optionally available as model number SCC190. Connecting a ... tool. (See Figure 37.) Before printing, you must setup the test tool for a specific printer.
70
Figure 36.
FE 192,196,199 C Users Manual - Page 94
Contact your nearest Fluke center for optimal response. Calibrating the Voltage Probes
To meet full user specifications, you need to adjust...replacement is needed, this should not be done by qualified personnel only.
The calibration consists of a high frequency adjustment and a dc calibration for 100:1 probes. Fluke 192B - 196B/C - 199B/C Users Manual
Replacing the NiMH Battery Pack...
FE 192,196,199 C Users Manual - Page 98
... for Probe Tip (gray) • Industrial Alligator for Banana Jack (gray) • 2-mm Test Probe for use with 4-mm Banana Jack (black)
90
Ordering Code VPS200-G
TL75 AS200-R
AS200-G Fluke 192B - 196B/C - 199B/C Users Manual
Item
Voltage Probe Set (Gray), designed for Banana Jack (gray) • Ground Lead with the Fluke ScopeMeter 190 series test tool.
FE 192,196,199 C Users Manual - Page 99
... Tip (2 red, 1 gray) • 2x Ground Lead with Hook Clip (red and gray) • 2x Ground Lead with User Manual (all languages)
8 Maintaining the Test Tool Parts and Accessories
Ordering Code RS200
Ordering Code 4822 872 30701 4822 872 30702 4822 872 30703 4822 872 30704 4822 872 30705 4822 872 30706 4822 872...
FE 192,196,199 C Users Manual - Page 100
... Case Kit
Set contains the following parts: Optically Isolated USB Adapter/Cable Hard Carrying Case FlukeView® ScopeMeter® Software for Windows® Optically Isolated USB Adapter/Cable Optically Isolated RS-232 Adapter/Cable Hard Case Soft Case Current Shunt 4-20 mA Print Adapter Cable for Parallel Printers
Optional Service Manual
Item Service Manual (English)
92
Ordering Code SCC190...
FE 192,196,199 C Users Manual - Page 104
.../C - 199B/C Users Manual
Dual Input Oscilloscope
Isolated Inputs A and B (Vertical)
Bandwidth, DC Coupled FLUKE 199B/C 200 MHz (-3 dB) FLUKE 196B/C 100 MHz (-3 dB) FLUKE 192B 60 MHz (-3 dB)
Lower Frequency Limit, AC Coupled with 10:1 probe 2 Hz (-3 dB) direct (1:1 5 Hz (-3 dB)
Rise Time FLUKE 199B/C 1.7 ns FLUKE 196B/C 3.5 ns FLUKE 192B 5.8 ns
Analog Bandwidth Limiters 20 MHz and 10 kHz...
FE 192,196,199 C Users Manual - Page 105
... versions)
9 Specifications
Dual Input Oscilloscope
Edge Trigger
Screen Update Free Run, On Trigger, Single Shot Source A, B, EXT Slope Positive, Negative, Dual (C versions) Trigger Level Control Range 4 divisions Trigger Sensitivity A and B
DC to 5 MHz at >5 mV/div 0.5 divisions DC to 5 MHz at 2 mV/div and 5 mV/div ...........1 division 200 MHz (FLUKE 199B/C 1 division 250 MHz (FLUKE 199B...
FE 192,196,199 C Users Manual - Page 117
... pF Attenuation at DC (1 MΩ input 10 x
Bandwidth (with FLUKE 199C) .....DC to 200 MHz (-3 dB)
Accuracy
Probe accuracy when adjusted on the test tool: DC to 20 kHz 1 % 20 kHz to 1 MHz 2 % 1 MHz to 25 MHz 3 %
For higher frequencies the probe's roll off starts affecting the accuracy
9 Specifications 10:1 Probe
Environmental
Temperature Operating 0 to 50 °C (32...
FE 192,196,199 C Users Manual - Page 122
Fluke 192B - 196B/C - 199B/C
Users Manual
Scope Record, 104 Scope Record, 37 Screen Contrast, 78 Screen Without Menus, 10, 77 Serial Printer, 70 Service Manual, 92 Shock, 107 Single Shot, 56 Single Sweep Mode, 38 Slope, 52, 97 Slow Variations, 34 Smooth, 15 Soft Case, 92 Software, 3, 92 Software Version, 88 Specifications, 95 Spectrum, 21 Spike Capture, 17 Stand, 77...
Fluke ScopeMeter Product Datasheet - Page 2
..., very small parts of a high-performance oscilloscope in a handheld, battery powered instrument.
• Dual-input - 200, 100 or 60 MHz
bandwidth
• Up to 2.5 GS/s real-time sampling
per input record
length using "zoom". Advanced trigger modes The ScopeMeter 190 Series simplifies triggering with 400 ps resolution. gering and a full range of manual trigger modes
•...
Fluke ScopeMeter Product Datasheet - Page 3
... monitor your ScopeMeter by the cursors. Deep memory for back-up to the main instrument type number, e.g., Fluke 199C/S (see it . SCC190 Kit
SCC120 Kit
FlukeView® Software for documenting, archiving and analysis
FlukeView for Windows® helps you can be caused by adding an "S" to 16 days. ence waveforms, add operator instructions, and send...
Fluke ScopeMeter Product Datasheet - Page 5
... Waveform mathematics Save set-ups and screens True-rms multimeter Safety, Power and Warranty Safety (EN61010-1) Battery Line power PC and printer interface Warranty
190C ScopeMeter Series
190B ScopeMeter Series
120 Series
Fluke 199C Fluke 196C
Fluke 199B
Fluke 196B
Fluke 192B
Fluke 125
Fluke 124
Fluke 123
200 MHz
100 MHz
200 MHz
100 MHz
60 MHz
40 MHz
40 MHz
20 MHz
2.5 GS...