Fluke 1623-2 Support and Manuals
Get Help and Manuals for this Fluke item
This item is in your list!
View All Support Options Below
Free Fluke 1623-2 manuals!
Problems with Fluke 1623-2?
Ask a Question
Free Fluke 1623-2 manuals!
Problems with Fluke 1623-2?
Ask a Question
Popular Fluke 1623-2 Manual Pages
Manual - Page 1
1623-2
Earth/Ground Tester
Users Manual
MyFlukeStore Shop for Fluke products online at: www.
.com 1.877.766.5412
Manual - Page 10
1623-2
Users Manual... between the terminals or between each terminal and earth ground. • Use only current probes, test ...test leads if they are dangerous to the user. A voltage measurement is necessary to know ...• Do not use the Product if it operates incorrectly. • Do not use the Product ... and locked before you operate the Product. • Replace the batteries when the low...
Manual - Page 11
...remove the batteries.
3
MyFlukeStore Shop for Fluke products online at: www.
.com 1.877.766.5412 Storage
If the Tester is stored for an extended period of ...manual.
Risk of Danger.
See Manual.
Hazardous voltage.
Symbols
Symbol
Description
Risk of electrical shock. Table 1. Earth/Ground Tester
Storage
Table 1 is a list of symbols used on the Tester...
Manual - Page 12
... the models and accessories. Models and Accessories
Description
1623-2 Earth Ground Tester (Includes Users Manual, Safety Information, QRG, Geox Probe Cable, 2 clips, Lead set)
1623-2 Earth Ground Tester Kit (Includes Users Manual, Safety Information, QRG, Geox Probe Cable, 2 clips, Lead set, 4 Earth Stakes, 3 Cable Reels, C1620 Carrying Case, EI-162X & EI-162AC)
162x-7001 Service Replacement Kit...
Manual - Page 14
...for the Tester include: • Earth/ground resistance measurements in different installations, such as, high
voltage pylons, buildings, electrical service grounding systems, mobile communication stations, and HF transmitters. • Monitor and plan lightning protection systems • Resistance measurements with earth electrodes;
1623-2
Users Manual
Features
Typical applications for Fluke...
Manual - Page 17
Battery Insertion
edv002.eps
9
MyFlukeStore Shop for Fluke products online at: www.
.com 1.877.766.5412 1
2
1623-2 EARTH/GROUND TESTER
Earth/Ground Tester
Setup
3
4
+
Figure 2.
Manual - Page 20
1623-2
Users Manual
1
2
1623-2 EARTH/GROUND TESTER
E/C1
H/C2
3
4
START
1
1623-2 EARTH/GROUND TESTER
Figure 3. RA 2-Pole Measurement 2
>20 m
edv003.eps
E/C1
S/P2
H/C2
3
4
START
>20 m
>20 m
Figure 4. RA 3-Pole Measurement
edv003b.eps
12
MyFlukeStore Shop for Fluke products online at: www.
.com 1.877.766.5412
Manual - Page 22
1623-2
Users Manual
1
2
1623-2 EARTH/GROUND TESTER
ES/P1 E/C1
S/P2
H/C2
3
4
START
>20 m
>20 m
Figure 5. RA 4-Pole Measurements
edv004.eps
14
MyFlukeStore Shop for Fluke products online at: www.
.com 1.877.766.5412
Manual - Page 24
RA 3-Pole Selective Earth Resistance Measurement with Current Clamp
edv005.eps
16
MyFlukeStore Shop for Fluke products online at: www.
.com 1.877.766.5412 1623-2
Users Manual
1
2
1623-2 EARTH/GROUND TESTER
E/C1
S/P2
H/C2
3
4
START
>20 m
>20 m
E
S H
Figure 6.
Manual - Page 29
... circuit of the other by an overhead earth wire. Earth/Ground Tester
Advanced Operation
Advanced Operation
The Tester uses advanced features to measure earth resistance of a single high voltage pylon and soil resistivity for Fluke products online at: www.
.com 1.877.766.5412
Earthing Resistance without disconnection of the earthing system from the pylon construction. with its...
Manual - Page 32
... physical quantity for Fluke products online at: www.
.com 1.877.766.5412 Measurement of Standards, Bulletin 12 (4), Paper 258, S 478-496; 1915/16).
1623-2 EARTH/GROUND TESTER
Figure 10. Turn... measuring earth resistivity; Four earth stakes of the same length are positioned into the soil in Figure 10 uses the method developed by Wenner (F. Push START.
4. 1623-2
Users Manual
Measurement ...
Manual - Page 34
1623-2
Users Manual
Curve 3:
With increasing depth ρE is not decreasing: a strip conductor electrode is turned by underground pieces of metal and underground aquifers, a second measurement, in the Tester: 1. Table 5 is an example of 90 °, is always advisable (see graph below).
90°
E
ES
S
H
I
Export Stored Data to PC
edw022.eps
Test data ...
Manual - Page 38
1623-2
Users Manual
Specifications
Temperature ranges Operating temperature range: Storage temperature range:
Temperature coefficient:
Operating humidity:
Operating ... memory storage up to 1500 records accessible via USB port
RA 3-Pole and 4-Pole ground resistance measurement
Resolution
Measurement range
Accuracy
Operating error
0.001 ... 10 Ω
0.020 Ω to 19,99 kΩ
±...
Datasheet - Page 1
... value
• R* measurement -
MyFlukeStore Shop for outdoor use . The complete model kit comes with the 1623-2 or 1625-2 tester, test leads, 4 earth ground stakes, 3 cable reels with a gloved hand. Fluke 1623-2 and 1625-2
GEO Earth Ground Testers
Technical Data
The new Fluke 1623-2 and 1625-2 GEO Earth Ground Testers offer data storage and download capabilities via USB port. With this...
Datasheet - Page 10
...; •
Stakeless 2 clamps
• •
Ordering information
Fluke-1623-2 Kit Fluke-1623-2 EI-1623 Fluke-1625-2 Kit Fluke-1625-2 EI-1625
Basic GEO Earth Ground Tester Kit Basic GEO Earth Ground Tester Selective/Stakeless Clamp Set for 1623 Advanced GEO Earth Ground Tester Kit Advanced GEO Earth Ground Tester Selective/Stakeless Clamp Set for 1625
Optional accessories
ES-162P3-2 ES-162P4...
Fluke 1623-2 Reviews
Do you have an experience with the Fluke 1623-2 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fluke yet.
Earn 750 points for your review!