Fluke 116 Digital Multimeter Datasheet
Page 1
... microamp measurements to quickly troubleshoot problems with HVAC equipment and flame sensors. Fluke 116 HVAC Multimeter with Temperature and Microamps Technical Data Actual size R N10140 Compact true-rms meter for HVAC troubleshooting The Fluke 116 was specifically designed for 1 year after calibration, at operating temperatures of reading ] + [ counts ] ) Maximum voltage between any terminal and earth ground Surge...
... microamp measurements to quickly troubleshoot problems with HVAC equipment and flame sensors. Fluke 116 HVAC Multimeter with Temperature and Microamps Technical Data Actual size R N10140 Compact true-rms meter for HVAC troubleshooting The Fluke 116 was specifically designed for 1 year after calibration, at operating temperatures of reading ] + [ counts ] ) Maximum voltage between any terminal and earth ground Surge...
Fluke 116 Users Manual
Page 8
116 Users Manual Terminals COM + 2 1 edy01f.eps No. bAtt CAL Err EEPr Err F11Err Error Messages Battery must be repaired before the Meter will operate. Calibration required. Internal error. Meter calibration is... required before it will operate. The Meter must be repaired before the Meter will operate. 6 B Input terminal for all measurements. Internal error. The Meter must be replaced before it will operate. Description A Common (return) terminal for measuring voltage, continuity, resistance, capacitance, frequency, temperature...
116 Users Manual Terminals COM + 2 1 edy01f.eps No. bAtt CAL Err EEPr Err F11Err Error Messages Battery must be repaired before the Meter will operate. Calibration required. Internal error. Meter calibration is... required before it will operate. The Meter must be repaired before the Meter will operate. 6 B Input terminal for all measurements. Internal error. The Meter must be replaced before it will operate. Description A Common (return) terminal for measuring voltage, continuity, resistance, capacitance, frequency, temperature...
Fluke 116 Users Manual
Page 20
..., CAN/CSA-C22.2 No 61010-1-04, UL 6101B (2003) and IEC/EN 61010-1 2nd Edition for 1 year after calibration, at operating temperatures of 18 °C to 90 %. Maximum voltage between any terminal and earth ground 600 V Surge Protection 6 kV peak ...to + 60 °C Temperature Coefficient 0.1 x (specified accuracy)/°C (28 °C) Operating Altitude 2,000 meters Battery 9 Volt Alkaline, NEDA 1604A / IEC 6LR61 Battery Life Alkaline: 400 hours typical, without backlight Safety Compliances Complies with relative humidity at www.Fluke.com. 116 Users Manual General Specifications Accuracy...
..., CAN/CSA-C22.2 No 61010-1-04, UL 6101B (2003) and IEC/EN 61010-1 2nd Edition for 1 year after calibration, at operating temperatures of 18 °C to 90 %. Maximum voltage between any terminal and earth ground 600 V Surge Protection 6 kV peak ...to + 60 °C Temperature Coefficient 0.1 x (specified accuracy)/°C (28 °C) Operating Altitude 2,000 meters Battery 9 Volt Alkaline, NEDA 1604A / IEC 6LR61 Battery Life Alkaline: 400 hours typical, without backlight Safety Compliances Complies with relative humidity at www.Fluke.com. 116 Users Manual General Specifications Accuracy...