Glossary
Page 7
... ports. SAN - Second(s). Allows hard drives to report errors and failures to the system BIOS and then display an error message on motherboard. RAID - ROM - A standard interface between... -only file is one bit at a time and is lost when you call Dell for program instructions and data. service tag - RAM - Any information stored in...are prohibited from editing or deleting. A network architecture that contains information supplementing or updating the product's documentation. SAS - Serial-attached SCSI. Serial Advanced Technology Attachment. SCSI...
... ports. SAN - Second(s). Allows hard drives to report errors and failures to the system BIOS and then display an error message on motherboard. RAID - ROM - A standard interface between... -only file is one bit at a time and is lost when you call Dell for program instructions and data. service tag - RAM - Any information stored in...are prohibited from editing or deleting. A network architecture that contains information supplementing or updating the product's documentation. SAS - Serial-attached SCSI. Serial Advanced Technology Attachment. SCSI...
Information Update - Intel Xeon 5600 Series Processors
Page 1
...; The following new Dell PowerEdge systems marked with the Intel Xeon 5600 series processors support memory sparing. R510 - NOTE: The PowerEdge R610 and M710 systems need specific heat sinks to support Intel Xeon 5600 series processor (less than 130 W). T610 - Intel Xeon 5600 Series Processors- T410 - NOTE: A BIOS and iDRAC firmware update only supports a limited...
...; The following new Dell PowerEdge systems marked with the Intel Xeon 5600 series processors support memory sparing. R510 - NOTE: The PowerEdge R610 and M710 systems need specific heat sinks to support Intel Xeon 5600 series processor (less than 130 W). T610 - Intel Xeon 5600 Series Processors- T410 - NOTE: A BIOS and iDRAC firmware update only supports a limited...
Information Update - System Setup Program
Page 1
NOTE: Applies to PowerEdge R410, R510, R610, R710, R910, T410, T610, and T710 systems only. Integrated Devices Screen Option Option SR-IOV-Global Enable (Disabled default) Description Enables/disables BIOS configuration of Single Root I/O Virtualization (SR-IOV) devices. December 2010 Table 1. Information Update System Setup Program Update Table 1 lists the new option for the Integrated Devices screen.
NOTE: Applies to PowerEdge R410, R510, R610, R710, R910, T410, T610, and T710 systems only. Integrated Devices Screen Option Option SR-IOV-Global Enable (Disabled default) Description Enables/disables BIOS configuration of Single Root I/O Virtualization (SR-IOV) devices. December 2010 Table 1. Information Update System Setup Program Update Table 1 lists the new option for the Integrated Devices screen.
Information Update
Page 3
...knowledge base article KB968410 at microsoft.com. Flash Memory The VFlash media provided by Dell is used. The system does not boot to the operating system unless a boot...running Microsoft Windows Server 2008 do not support iSCSI boot when they have an SD card installed in legacy BIOS modes. For more than 4 GB of memory installed. When you are documented on systems with 1 TB...use the virtual flash feature for the first time, you use the mem= 1024M boot time switch. Information Update 3 In addition, iSCSI boot does not work when an external USB storage device is Not Used) Red ...
...knowledge base article KB968410 at microsoft.com. Flash Memory The VFlash media provided by Dell is used. The system does not boot to the operating system unless a boot...running Microsoft Windows Server 2008 do not support iSCSI boot when they have an SD card installed in legacy BIOS modes. For more than 4 GB of memory installed. When you are documented on systems with 1 TB...use the virtual flash feature for the first time, you use the mem= 1024M boot time switch. Information Update 3 In addition, iSCSI boot does not work when an external USB storage device is Not Used) Red ...
Information Update
Page 5
... the slots with other vendors such as Intel. Information Update 5 Dell Update Package Information During the Dell Update Package (DUP) installation process, you disable the OS Watchdog Timer in the system BIOS when running the BIOS DUP. For more than 4 KB of I /O address...BIOS is recommended that you use Broadcom teaming driver. Due to the limitation of 64 KB I/O address space on supported adapters, see messages related to 10. The system may reboot in the middle of PCIe expansion slots available in Windows CAUTION: Ensure that you may see the Dell™ PowerEdge™ R910...
... the slots with other vendors such as Intel. Information Update 5 Dell Update Package Information During the Dell Update Package (DUP) installation process, you disable the OS Watchdog Timer in the system BIOS when running the BIOS DUP. For more than 4 KB of I /O address...BIOS is recommended that you use Broadcom teaming driver. Due to the limitation of 64 KB I/O address space on supported adapters, see messages related to 10. The system may reboot in the middle of PCIe expansion slots available in Windows CAUTION: Ensure that you may see the Dell™ PowerEdge™ R910...
Information Update
Page 7
... in the Hardware Owner's Manual. You should only perform troubleshooting and simple repairs as directed by the online or telephone service and support team. Information Update 7 Installing Memory Modules WARNING: The memory modules are hot to cool before handling them. Damage due to servicing that came with a 10 Gb I /O Card) For... Active Power Controller Disabled ATA Mode Power Supply Redundancy Mode (With a 10 Gb I /O card and four power supplies, the redundancy mode is not covered by Dell is 2+1. Hardware Owner's Manual Updates BIOS Setup Options Default Settings...
... in the Hardware Owner's Manual. You should only perform troubleshooting and simple repairs as directed by the online or telephone service and support team. Information Update 7 Installing Memory Modules WARNING: The memory modules are hot to cool before handling them. Damage due to servicing that came with a 10 Gb I /O Card) For... Active Power Controller Disabled ATA Mode Power Supply Redundancy Mode (With a 10 Gb I /O card and four power supplies, the redundancy mode is not covered by Dell is 2+1. Hardware Owner's Manual Updates BIOS Setup Options Default Settings...
Information Update
Page 17
...KB I/O PCI 4 KB I/O 4 KB I/O I/O 64 KB I/O POST support.dell.com/manuals 上的 Dell™ PowerEdge™ R910 Hardware Owner's Manual(Dell™ PowerEdge™ R910 Dell Update Package 信息 在安装 Dell Update Package (DUP • Request for system reboot before the DUP installation is complete...65288;Windows 中 VFlash VFlash 上安装 DUP 运行 BIOS DUP BIOS 中禁用 OS Watchdog Timer • 系统 BIOS OS Watchdog Timer 信息更新 17
...KB I/O PCI 4 KB I/O 4 KB I/O I/O 64 KB I/O POST support.dell.com/manuals 上的 Dell™ PowerEdge™ R910 Hardware Owner's Manual(Dell™ PowerEdge™ R910 Dell Update Package 信息 在安装 Dell Update Package (DUP • Request for system reboot before the DUP installation is complete...65288;Windows 中 VFlash VFlash 上安装 DUP 运行 BIOS DUP BIOS 中禁用 OS Watchdog Timer • 系统 BIOS OS Watchdog Timer 信息更新 17
Information Update
Page 67
... Update Microsoft support.microsoft.com Microsoft Windows Server® 2003 또는 Windows Server 2008 4GB 4GB microsoft.com KB888575 • 1TB Microsoft Windows Server 2008 R2 UEFI(Unified Extensible Firmware Interface BIOS microsoft.com KB980598 • Microsoft Windows Server 2008 SD 모듈에 SD iSCSI iSCSI USB microsoft.com KB968410 Dell...
... Update Microsoft support.microsoft.com Microsoft Windows Server® 2003 또는 Windows Server 2008 4GB 4GB microsoft.com KB888575 • 1TB Microsoft Windows Server 2008 R2 UEFI(Unified Extensible Firmware Interface BIOS microsoft.com KB980598 • Microsoft Windows Server 2008 SD 모듈에 SD iSCSI iSCSI USB microsoft.com KB968410 Dell...
Hardware Owner's Manual
Page 44
...! NVRAM_CLR jumper is installed on page 203. CPU set lower for jumper location. CPUs with different cache sizes detected. Retry the BIOS update. Move the NVRAM_CLR jumper to minimum frequency. See "Using the System Setup Program and UEFI Boot Manager" on page 148. System... halted. Message Causes Corrective Actions BIOS Update Remote BIOS update Attempt Failed! The processor speed may be If not an intentional setting, intentionally set to the default position (pins 3 and ...
...! NVRAM_CLR jumper is installed on page 203. CPU set lower for jumper location. CPUs with different cache sizes detected. Retry the BIOS update. Move the NVRAM_CLR jumper to minimum frequency. See "Using the System Setup Program and UEFI Boot Manager" on page 148. System... halted. Message Causes Corrective Actions BIOS Update Remote BIOS update Attempt Failed! The processor speed may be If not an intentional setting, intentionally set to the default position (pins 3 and ...
Hardware Owner's Manual
Page 58
...has a faulty cable check the cable connections connection. The control panel is not installed. See "Control Panel Assembly" on page 203. Update the BIOS firmware. Power required exceeds PSU wattage. CPU and memory set to minimum frequencies to use the components. System will reboot. If Energy... to the previous configuration. Warning! between the display module, the control panel board, and the system board. No micro Micro code update failed. Warning! You can also run the system on one power supply until you can obtain two power supplies of processor(s), memory ...
...has a faulty cable check the cable connections connection. The control panel is not installed. See "Control Panel Assembly" on page 203. Update the BIOS firmware. Power required exceeds PSU wattage. CPU and memory set to minimum frequencies to use the components. System will reboot. If Energy... to the previous configuration. Warning! between the display module, the control panel board, and the system board. No micro Micro code update failed. Warning! You can also run the system on one power supply until you can obtain two power supplies of processor(s), memory ...
Hardware Owner's Manual
Page 148
...Damage due to servicing that you must ensure that came with the product. 1 Prior to install the update on your system, download the latest system BIOS version from support.dell.com and follow the safety instructions that the RAID battery cable faces the chassis wall. 5 Install the ...file to upgrading your system. 2 Turn off the system, including any attached peripherals. NOTE: It is recommended that is not authorized by Dell is not covered by your product documentation, or as directed by a certified service technician. Processors Removing a Processor CAUTION: Many repairs may only...
...Damage due to servicing that you must ensure that came with the product. 1 Prior to install the update on your system, download the latest system BIOS version from support.dell.com and follow the safety instructions that the RAID battery cable faces the chassis wall. 5 Install the ...file to upgrading your system. 2 Turn off the system, including any attached peripherals. NOTE: It is recommended that is not authorized by Dell is not covered by your product documentation, or as directed by a certified service technician. Processors Removing a Processor CAUTION: Many repairs may only...