Glossary
Page 3
... version 6. 3 Gravities. host adapter - A remote access controller that implements communication between the system's bus and the peripheral device, typically a storage device. Fibre Channel - flash memory - G - A standard interface between the processor and the main memory (RAM). Integrated Dell Remote Access Controller. InfiniBand - IPv6 - expansion-card connector - F - The Microsoft® Windows® operating systems can be defined as x horizontal by y vertical pixels by MS-DOS to -point bidirectional serial links intended for plugging in an expansion card...
... version 6. 3 Gravities. host adapter - A remote access controller that implements communication between the system's bus and the peripheral device, typically a storage device. Fibre Channel - flash memory - G - A standard interface between the processor and the main memory (RAM). Integrated Dell Remote Access Controller. InfiniBand - IPv6 - expansion-card connector - F - The Microsoft® Windows® operating systems can be defined as x horizontal by y vertical pixels by MS-DOS to -point bidirectional serial links intended for plugging in an expansion card...
Hardware Owner's Manual
Page 119
... improperly installed PCIe card in the specified slot. Faulty or improperly installed mezzanine card. Set the NVRAM_CLR jumper to install. Check for the jumper location. See "Blade System Board Jumper Settings" on page 127. Invalid configuration information please run SETUP program CMOS checksum failure. Reseat the PCIe card in initializing PCI device; BIOS remote update failed. If the problem persists, see "Getting Help" on page 337. Retry the BIOS update. See "Using the System Setup Program and UEFI Boot Manager" on page 309 for a BIOS update...
... improperly installed PCIe card in the specified slot. Faulty or improperly installed mezzanine card. Set the NVRAM_CLR jumper to install. Check for the jumper location. See "Blade System Board Jumper Settings" on page 127. Invalid configuration information please run SETUP program CMOS checksum failure. Reseat the PCIe card in initializing PCI device; BIOS remote update failed. If the problem persists, see "Getting Help" on page 337. Retry the BIOS update. See "Using the System Setup Program and UEFI Boot Manager" on page 309 for a BIOS update...
Hardware Owner's Manual
Page 127
... boot the operating system from the BIOS boot mode. DOS and 32-bit operating systems do not support UEFI and can : • Change the NVRAM settings after you add or remove hardware • View the system hardware configuration • Enable or disable integrated devices • Set performance and power management thresholds • Manage system security Choosing the System Boot Mode The System Setup program also enables you must boot the system to the same boot mode (BIOS or UEFI) to install your system hardware and specify BIOS...
... boot the operating system from the BIOS boot mode. DOS and 32-bit operating systems do not support UEFI and can : • Change the NVRAM settings after you add or remove hardware • View the system hardware configuration • Enable or disable integrated devices • Set performance and power management thresholds • Manage system security Choosing the System Boot Mode The System Setup program also enables you must boot the system to the same boot mode (BIOS or UEFI) to install your system hardware and specify BIOS...
Hardware Owner's Manual
Page 131
... software. This feature can also set the voltage of the installed memory (Auto default) modules. Node Interleaving (Disabled default) If set to Auto, the system sets the voltage to Disabled (default), NUMA is implemented. Options are Mirror Mode, Spare Mode, and Disabled. Memory Operating If set to an optimal Voltage value based on the capacity of the memory (PowerEdge M710HD) module to use Virtualization Technology incorporated in the processor design. Displays the bus speed of the processors. Using the System Setup Program and UEFI Boot Manager...
... software. This feature can also set the voltage of the installed memory (Auto default) modules. Node Interleaving (Disabled default) If set to Auto, the system sets the voltage to Disabled (default), NUMA is implemented. Options are Mirror Mode, Spare Mode, and Disabled. Memory Operating If set to an optimal Voltage value based on the capacity of the memory (PowerEdge M710HD) module to use Virtualization Technology incorporated in the processor design. Displays the bus speed of the processors. Using the System Setup Program and UEFI Boot Manager...
Hardware Owner's Manual
Page 132
... Disable Memory Protection Technology is enabled. When set to compute. Off disables BIOS support for the device. Off disables BIOS support for the device. 132 Using the System Setup Program and UEFI Boot Manager Enables or disables data reuse in each processor. If supported by the processor(s), enables or disables Turbo Mode. Option Adjacent Cache Line Prefetch (Enabled default) Hardware Prefetcher (Enabled default) DCU Streamer Prefetcher (Enabled default) Data Reuse Execute Disable (Enabled default) Number of the processor(s). Enables or disables the hardware...
... Disable Memory Protection Technology is enabled. When set to compute. Off disables BIOS support for the device. Off disables BIOS support for the device. 132 Using the System Setup Program and UEFI Boot Manager Enables or disables data reuse in each processor. If supported by the processor(s), enables or disables Turbo Mode. Option Adjacent Cache Line Prefetch (Enabled default) Hardware Prefetcher (Enabled default) DCU Streamer Prefetcher (Enabled default) Data Reuse Execute Disable (Enabled default) Number of the processor(s). Enables or disables the hardware...
Hardware Owner's Manual
Page 134
... Card Port (PowerEdge M910, M905, M805, M710, M710HD, M610 and M610x) Enables or disables the system's internal SD card port. Changes NICn take effect after the system reboots. This field does not have user-selectable settings. Capability Detected Displays the features provided by the hardware key installed in IDSDM. Redundancy (Disabled default) (M910 and M710HD) Enables or disables the mirror mode for a particular integrated NIC. This field does not have user-selectable settings. iSCSI MAC Address Displays...
... Card Port (PowerEdge M910, M905, M805, M710, M710HD, M610 and M610x) Enables or disables the system's internal SD card port. Changes NICn take effect after the system reboots. This field does not have user-selectable settings. Capability Detected Displays the features provided by the hardware key installed in IDSDM. Redundancy (Disabled default) (M910 and M710HD) Enables or disables the mirror mode for a particular integrated NIC. This field does not have user-selectable settings. iSCSI MAC Address Displays...
Hardware Owner's Manual
Page 140
... shipped without rebooting. Disabling the password jumper on the system board sets System Password to run utilities such as system diagnostics. Accesses the BIOS-level boot options list without the system password feature enabled. System and Setup Password Features Your system is running and unattended. Restarts the system and accesses the Unified Server Configurator, which allows you to Disabled, and you cannot change or enter a new system password. 140 Using the System Setup Program and UEFI Boot Manager Restarts the...
... shipped without rebooting. Disabling the password jumper on the system board sets System Password to run utilities such as system diagnostics. Accesses the BIOS-level boot options list without the system password feature enabled. System and Setup Password Features Your system is running and unattended. Restarts the system and accesses the Unified Server Configurator, which allows you to Disabled, and you cannot change or enter a new system password. 140 Using the System Setup Program and UEFI Boot Manager Restarts the...
Hardware Owner's Manual
Page 290
... telephone service and support team. See "Removing a Power Supply Module" on page 269. 290 Troubleshooting Your System Responding to the blade front panel. CAUTION: Wait until all of a USB cable should only perform troubleshooting and simple repairs as authorized in the system. For information about the CMC alert messages, see the Configuration Guide. Read and follow the safety instructions that is not authorized by Dell is installed, connect the USB device...
... telephone service and support team. See "Removing a Power Supply Module" on page 269. 290 Troubleshooting Your System Responding to the blade front panel. CAUTION: Wait until all of a USB cable should only perform troubleshooting and simple repairs as authorized in the system. For information about the CMC alert messages, see the Configuration Guide. Read and follow the safety instructions that is not authorized by Dell is installed, connect the USB device...
Dell M8428-k Hardware Reference Manual
Page 13
...-k 6 Dell M8428-k overview The Dell M8428-k is designed to be done through Dell Chassis Management Controller (CMC), the browser based GUI, or the command line interface (CLI). The switch module is a 28-port switch module with N_Port ID Virtualization (NPIV) mode enabled. The external CEE ports operate at either NPIV mode or full fabric mode. • The switch module is made by default. The 16 internal ports connect to the server utilizing 10GBase-KR (KR) technology. Dell M8428-k Hardware Reference Manual...
...-k 6 Dell M8428-k overview The Dell M8428-k is designed to be done through Dell Chassis Management Controller (CMC), the browser based GUI, or the command line interface (CLI). The switch module is a 28-port switch module with N_Port ID Virtualization (NPIV) mode enabled. The external CEE ports operate at either NPIV mode or full fabric mode. • The switch module is made by default. The 16 internal ports connect to the server utilizing 10GBase-KR (KR) technology. Dell M8428-k Hardware Reference Manual...
Dell PowerConnect M8024-k Release Notes
Page 23
... ' version. Generic failure message is issued. If a user enters an invalid interface, a generic error message is issued. The user can configure "general" mode VLANs, which interfaces. Disable portfast and auto-portfast on physical ports configured in earlier versions; Only use speed auto/duplex auto commands on dynamic LAG - The software recognizes if the group name is Read/Write capable. User can ping the TFTP server from the switch. The user will receive adequate power...
... ' version. Generic failure message is issued. If a user enters an invalid interface, a generic error message is issued. The user can configure "general" mode VLANs, which interfaces. Disable portfast and auto-portfast on physical ports configured in earlier versions; Only use speed auto/duplex auto commands on dynamic LAG - The software recognizes if the group name is Read/Write capable. User can ping the TFTP server from the switch. The user will receive adequate power...
Dell PowerConnect M8024-k User's Configuration Guide
Page 785
... and naming the association (as a service instance). Configuring Connectivity Fault Management 785 ethernet cfm cc level level vlan Configure the Continuity Check Message (CCM) vlan-id interval {1 | 10 | 60 | transmit interval for that MD. exit Exit to configure Dot1ag settings on the switch. For more information about the commands you use the following commands to configure CFM settings and to view global status and domain information. ethernet cfm...
... and naming the association (as a service instance). Configuring Connectivity Fault Management 785 ethernet cfm cc level level vlan Configure the Continuity Check Message (CCM) vlan-id interval {1 | 10 | 60 | transmit interval for that MD. exit Exit to configure Dot1ag settings on the switch. For more information about the commands you use the following commands to configure CFM settings and to view global status and domain information. ethernet cfm...
Dell PowerConnect M6220/M6348/M8024/M8024-k CLI Reference Guide
Page 186
... a valid password. The wizard sets up the default gateway IP address. 186 Using the CLI SNMPv3 is disabled until the user returns to configure security access for SNMPv3 (for the SNMP management interface. Initially only SNMPv1/2c will be used . The initial activation must be completely manageable through the Web, CLI and the remote Dell Network Manager. The wizard configures one privileged user account during the setup. After initial setup, the user may...
... a valid password. The wizard sets up the default gateway IP address. 186 Using the CLI SNMPv3 is disabled until the user returns to configure security access for SNMPv3 (for the SNMP management interface. Initially only SNMPv1/2c will be used . The initial activation must be completely manageable through the Web, CLI and the remote Dell Network Manager. The wizard configures one privileged user account during the setup. After initial setup, the user may...
Brocade 4424 Blade Server SAN I/O Module Hardware Reference
Page 8
... call, have the following information available: 1. Fabric Watch Continuously monitors SAN fabrics for potential faults based on thresholds set for hardware, firmware, and software support, including product repairs and part ordering. General Information Technical Support contract number, if applicable SAN I/O Module model SAN I /O Module Hardware Reference Manual 53-0000571-01 Extended Fabrics Supports the reliable, high-speed connectivity of Brocade switches over dark fiber or Dense Wave Division Multiplexing (DWDM) equipment...
... call, have the following information available: 1. Fabric Watch Continuously monitors SAN fabrics for potential faults based on thresholds set for hardware, firmware, and software support, including product repairs and part ordering. General Information Technical Support contract number, if applicable SAN I/O Module model SAN I /O Module Hardware Reference Manual 53-0000571-01 Extended Fabrics Supports the reliable, high-speed connectivity of Brocade switches over dark fiber or Dense Wave Division Multiplexing (DWDM) equipment...
Dell PowerEdge M620 Systems Owner's Manual
Page 11
... System Services, which is enabled by default • Text browser, which opens the Dell Lifecycle Controller 2 (LC2). From the System Setup, you can: • Change the NVRAM settings after you add or remove hardware • View the system hardware configuration • Enable or disable integrated devices • Set performance and power management thresholds • Manage system security You can access the System Setup using the: • Standard graphical browser, which is enabled using Console Redirection To enable Console Redirection, in the Boot Mode...
... System Services, which is enabled by default • Text browser, which opens the Dell Lifecycle Controller 2 (LC2). From the System Setup, you can: • Change the NVRAM settings after you add or remove hardware • View the system hardware configuration • Enable or disable integrated devices • Set performance and power management thresholds • Manage system security You can access the System Setup using the: • Standard graphical browser, which is enabled using Console Redirection To enable Console Redirection, in the Boot Mode...
Dell PowerEdge M620 Systems Owner's Manual
Page 115
... system input power. Action Replace diskette with a bootable disk. 115 Action Reboot the management controller or iDRAC. If problem persists call support. SEL1204 Message An unknown system hardware failure detected. Some management software will not report platform exceptions. Action Re-configure system to the log. Details System setup displays the system boot order. Action Backup and clear log at the next maintained time. LCD Message Unknown system hardware failure. Check if mass storage controller configuration settings are not captured...
... system input power. Action Replace diskette with a bootable disk. 115 Action Reboot the management controller or iDRAC. If problem persists call support. SEL1204 Message An unknown system hardware failure detected. Some management software will not report platform exceptions. Action Re-configure system to the log. Details System setup displays the system boot order. Action Backup and clear log at the next maintained time. LCD Message Unknown system hardware failure. Check if mass storage controller configuration settings are not captured...
Dell PowerEdge M520 Systems Owner's Manual
Page 11
... Enters the System Setup. To view the help text for installing your operating system: • BIOS boot mode (the default) is the standard BIOS-level boot interface. • UEFI boot mode is an enhanced 64-bit boot interface based on the system's boot configuration. Enters System Services, which is enabled using a graphical user interface. Enters the BIOS Boot Manager or the Unified Extensible Firmware Interface (UEFI) Boot Manager, depending on Unified Extensible Firmware Interface (UEFI) specifications that 11 Starts Preboot eXecution Environment (PXE) boot. Once you then...
... Enters the System Setup. To view the help text for installing your operating system: • BIOS boot mode (the default) is the standard BIOS-level boot interface. • UEFI boot mode is an enhanced 64-bit boot interface based on the system's boot configuration. Enters System Services, which is enabled using a graphical user interface. Enters the BIOS Boot Manager or the Unified Extensible Firmware Interface (UEFI) Boot Manager, depending on Unified Extensible Firmware Interface (UEFI) specifications that 11 Starts Preboot eXecution Environment (PXE) boot. Once you then...
Dell PowerEdge M520 Systems Owner's Manual
Page 17
... card fails, data is set the port address for Serial Over LAN (SOL). By default, the Integrated Card 1 Network Card 1 option is preventing booting into the Operating System or causing delays in the specified slot. NOTE: Only Serial Device 2 can be used for serial devices. Failsafe Baud Rate Displays the failsafe baud rate for console redirection and the serial device. Remote Terminal Type Allows you to enable or disable the Embedded Video Controller. Menu Item Internal SD Card Redundancy Description If set to set the remote console...
... card fails, data is set the port address for Serial Over LAN (SOL). By default, the Integrated Card 1 Network Card 1 option is preventing booting into the Operating System or causing delays in the specified slot. NOTE: Only Serial Device 2 can be used for serial devices. Failsafe Baud Rate Displays the failsafe baud rate for console redirection and the serial device. Remote Terminal Type Allows you to enable or disable the Embedded Video Controller. Menu Item Internal SD Card Redundancy Description If set to set the remote console...
Dell PowerEdge M520 Systems Owner's Manual
Page 111
... system input power. Details System setup displays the system boot order. Check if mass storage controller configuration settings are not captured. Action Replace diskette with a bootable disk. 111 If issues persists, contact support. Action Review platform event configuration. SEL1211 Message Details Action The time-stamp clock could not be overwritten and lost. If problem persists, contact support. Action Check system boot settings. SEL1302 Message Non-bootable diskette detected. Details The disk in the drive is...
... system input power. Details System setup displays the system boot order. Check if mass storage controller configuration settings are not captured. Action Replace diskette with a bootable disk. 111 If issues persists, contact support. Action Review platform event configuration. SEL1211 Message Details Action The time-stamp clock could not be overwritten and lost. If problem persists, contact support. Action Check system boot settings. SEL1302 Message Non-bootable diskette detected. Details The disk in the drive is...
Technical Guide
Page 34
... Serial redirection Remote configuration Remote update Email alerts SNMP alerts Comprehensive monitoring Virtual console (4 user) Virtual media Crash screen capture3 Power control Power monitoring Virtual console chat Support for customer-supplied SD cards for vVFirltausahl mflaesdhiapartitions Virtual folders Remote file share 34 PowerEdge M420 Technical Guide iDRAC7 Enterprise 1 iDRAC7 Express for Blades 1 2 Feature (function) Local configuration with Lifecycle Controller GUI IPMI 2.0 Embedded diagnostics Local OS install Local updates Driver pack Encryption Dedicated NIC 1Gbps...
... Serial redirection Remote configuration Remote update Email alerts SNMP alerts Comprehensive monitoring Virtual console (4 user) Virtual media Crash screen capture3 Power control Power monitoring Virtual console chat Support for customer-supplied SD cards for vVFirltausahl mflaesdhiapartitions Virtual folders Remote file share 34 PowerEdge M420 Technical Guide iDRAC7 Enterprise 1 iDRAC7 Express for Blades 1 2 Feature (function) Local configuration with Lifecycle Controller GUI IPMI 2.0 Embedded diagnostics Local OS install Local updates Driver pack Encryption Dedicated NIC 1Gbps...
Technical Guide
Page 44
... 44 PowerEdge M420 Technical Guide A printed version is available in PDF format on the Dell support site. This guide provides information on the following : Chassis features System Setup program System messages System codes and indicators System BIOS Remove and replace procedures Troubleshooting Diagnostics Jumpers and connectors Support.Dell.com/Manuals PowerEdge Modular Systems Hardware Owner's Manual This manual provides information on the PowerEdge M1000e chassis enclosure and its supported blade server...
... 44 PowerEdge M420 Technical Guide A printed version is available in PDF format on the Dell support site. This guide provides information on the following : Chassis features System Setup program System messages System codes and indicators System BIOS Remove and replace procedures Troubleshooting Diagnostics Jumpers and connectors Support.Dell.com/Manuals PowerEdge Modular Systems Hardware Owner's Manual This manual provides information on the PowerEdge M1000e chassis enclosure and its supported blade server...