Hardware Owner's Manual
Page 5
... Expansion Card 66 Removing the Expansion-Card Riser 66 Installing the Expansion-Card Riser 67 Removing the Expansion Card 68 Installing the Expansion Card 69 RAID Battery (Optional 70 Contents 5
... Expansion Card 66 Removing the Expansion-Card Riser 66 Installing the Expansion-Card Riser 67 Removing the Expansion Card 68 Installing the Expansion Card 69 RAID Battery (Optional 70 Contents 5
Hardware Owner's Manual
Page 6
Removing a RAID Battery 70 Installing a RAID Battery 70 Integrated Storage Controller Cards 72 Removing the Integrated Storage Controller Card 72 Installing the Integrated Storage Controller Card 73 Mezzanine Card (10 GbE ...
Removing a RAID Battery 70 Installing a RAID Battery 70 Integrated Storage Controller Cards 72 Removing the Integrated Storage Controller Card 72 Installing the Integrated Storage Controller Card 73 Mezzanine Card (10 GbE ...
Hardware Owner's Manual
Page 11
See "System Setup Options at Boot" on page 33. Enters the RAID configuration utility. About Your System 11 See "Start Menu" on page 34. Enters the utility to system features during startup. Keystroke Description... Enters the System Setup program. Starts Preboot eXecution Environment (PXE) boot. For more information, see the documentation for your SAS RAID card. For more information, see the SAS adapter documentation. Enters the SAS Configuration Utility. For more information, see the documentation for PXE boot. ...
See "System Setup Options at Boot" on page 33. Enters the RAID configuration utility. About Your System 11 See "Start Menu" on page 34. Enters the utility to system features during startup. Keystroke Description... Enters the System Setup program. Starts Preboot eXecution Environment (PXE) boot. For more information, see the documentation for your SAS RAID card. For more information, see the SAS adapter documentation. Enters the SAS Configuration Utility. For more information, see the documentation for PXE boot. ...
Hardware Owner's Manual
Page 38
... BIOS to program Closed Loop throttling for detecting ATA/ATAPI device(s). 38 Using the System Setup Program Configures the SATA. • IDE • AHCI • RAID Enables or disables device write protection. Memory Mode (Independent default) Selects the memory mode.
... BIOS to program Closed Loop throttling for detecting ATA/ATAPI device(s). 38 Using the System Setup Program Configures the SATA. • IDE • AHCI • RAID Enables or disables device write protection. Memory Mode (Independent default) Selects the memory mode.
Hardware Owner's Manual
Page 68
...bracket in controller memory and the data was not cleared at system shutdown. 3 If applicable, disconnect the RAID battery cable from the expansion-card riser. Filler brackets must be done by Dell is lit. The brackets also keep dust and dirt out of the system. Damage due to their electrical...the expansion card to the expansion-card riser. 2 Pull out the expansion card from the expansion card. 4 Insert the filler bracket. CAUTION: Disconnecting the RAID battery cable from a PERC card can cause data loss if the "dirty cache" LED on page 55. 6 Replace the system cover. See "Closing the...
...bracket in controller memory and the data was not cleared at system shutdown. 3 If applicable, disconnect the RAID battery cable from the expansion-card riser. Filler brackets must be done by Dell is lit. The brackets also keep dust and dirt out of the system. Damage due to their electrical...the expansion card to the expansion-card riser. 2 Pull out the expansion card from the expansion card. 4 Insert the filler bracket. CAUTION: Disconnecting the RAID battery cable from a PERC card can cause data loss if the "dirty cache" LED on page 55. 6 Replace the system cover. See "Closing the...
Hardware Owner's Manual
Page 70
... Remove the cooling shroud. Read and follow the safety instructions that is not authorized by Dell is not covered by your system and peripherals to the connector on the RAID battery. 2 Locate the RAID battery bay on page 54. 4 If applicable, remove the filler bracket. 5 Align ... applies only to systems with the product. See Figure 3-11. 6 For a battery-cached RAID controller, connect the RAID battery cable to servicing that came with the optional RAID controller card. Removing a RAID Battery 1 Turn off the system, including any attached peripherals, and disconnect the system from the...
... Remove the cooling shroud. Read and follow the safety instructions that is not authorized by Dell is not covered by your system and peripherals to the connector on the RAID battery. 2 Locate the RAID battery bay on page 54. 4 If applicable, remove the filler bracket. 5 Align ... applies only to systems with the product. See Figure 3-11. 6 For a battery-cached RAID controller, connect the RAID battery cable to servicing that came with the optional RAID controller card. Removing a RAID Battery 1 Turn off the system, including any attached peripherals, and disconnect the system from the...
Hardware Owner's Manual
Page 71
... 7 Reconnect your system and peripherals to the RAID battery connector on the system. Removing or Installing a RAID Battery 1 2 3 1 screws (2) 3 RAID battery 2 RAID battery bay Installing System Components 71 3 With the cable oriented toward the back, angle the left side of the RAID battery into the left side of the battery bay.... 4 Rotate the right side of the RAID battery down and press into the locked position. 5 Connect the RAID battery cable to their electrical outlets, and turn on the...
... 7 Reconnect your system and peripherals to the RAID battery connector on the system. Removing or Installing a RAID Battery 1 2 3 1 screws (2) 3 RAID battery 2 RAID battery bay Installing System Components 71 3 With the cable oriented toward the back, angle the left side of the RAID battery into the left side of the battery bay.... 4 Rotate the right side of the RAID battery down and press into the locked position. 5 Connect the RAID battery cable to their electrical outlets, and turn on the...
Hardware Owner's Manual
Page 72
... the safety instructions that provides the integrated storage subsystem for later use. You should only perform troubleshooting and simple repairs as authorized in RAID configurations as directed by a certified service technician. The controller supports SAS, SATA, and SSD hard drives and also enables you to ...remove it from its electrical outlet. 2 Open the system. Damage due to servicing that is not authorized by Dell is not covered by the version of the storage controller included with the product. 1 Turn off the system, including any attached peripherals,...
... the safety instructions that provides the integrated storage subsystem for later use. You should only perform troubleshooting and simple repairs as authorized in RAID configurations as directed by a certified service technician. The controller supports SAS, SATA, and SSD hard drives and also enables you to ...remove it from its electrical outlet. 2 Open the system. Damage due to servicing that is not authorized by Dell is not covered by the version of the storage controller included with the product. 1 Turn off the system, including any attached peripherals,...
Hardware Owner's Manual
Page 105
...2 Ensure that the required device drivers for information about the configuration utility. Read and follow the safety instructions that is not authorized by Dell is enabled and the drives appear in the System Setup program. See "Removing a Hard-Drive Carrier" on page 33. See "Using... as directed by a certified service technician. b Ensure that the controller is not covered by pressing for a PERC controller or for the RAID array. See the documentation supplied with the product. c Take the hard drive offline and reseat the drive. You should only perform troubleshooting ...
...2 Ensure that the required device drivers for information about the configuration utility. Read and follow the safety instructions that is not authorized by Dell is enabled and the drives appear in the System Setup program. See "Removing a Hard-Drive Carrier" on page 33. See "Using... as directed by a certified service technician. b Ensure that the controller is not covered by pressing for a PERC controller or for the RAID array. See the documentation supplied with the product. c Take the hard drive offline and reseat the drive. You should only perform troubleshooting ...
Hardware Owner's Manual
Page 106
... be done by the online or telephone service and support team. See "Installing the Expansion Card" on the RAID card is enabled. See "System Setup Options at Boot" on page 94. 6 Ensure that the cable connections... the applicable key sequence to enter the configuration utility program. • for a SAS controller • for a RAID controller See the controller's documentation for your warranty. Damage due to the storage controller and the SAS backplane board. ... seated. 8 Verify that the controller card is not covered by Dell is firmly seated into the system board connector.
... be done by the online or telephone service and support team. See "Installing the Expansion Card" on the RAID card is enabled. See "System Setup Options at Boot" on page 94. 6 Ensure that the cable connections... the applicable key sequence to enter the configuration utility program. • for a SAS controller • for a RAID controller See the controller's documentation for your warranty. Damage due to the storage controller and the SAS backplane board. ... seated. 8 Verify that the controller card is not covered by Dell is firmly seated into the system board connector.
Hardware Owner's Manual
Page 114
... the table of jumpers installed on backplane is not active state. Jumpers Installed on Backplane Jumper J22 J23 Function Off SGPIO connection *Disable RAID Card setting *Disable On Enable Enable NOTE: The "*" in your product documentation, or as directed by your warranty. Read and follow... the safety instructions that is not authorized by Dell is not covered by the online or telephone service and support team. Figure 5-3. 3.5-Inch Hard-Drive Systems Backplane Jumpers The function of ...
... the table of jumpers installed on backplane is not active state. Jumpers Installed on Backplane Jumper J22 J23 Function Off SGPIO connection *Disable RAID Card setting *Disable On Enable Enable NOTE: The "*" in your product documentation, or as directed by your warranty. Read and follow... the safety instructions that is not authorized by Dell is not covered by the online or telephone service and support team. Figure 5-3. 3.5-Inch Hard-Drive Systems Backplane Jumpers The function of ...
Hardware Owner's Manual
Page 125
memory key - mm - NAS - A device that connects to a network. NVRAM - In RAID arrays, a striped hard drive containing parity data. partition - A specific location, usually expressed as integrated memory (ROM and ...called partitions with a USB connector. memory module - A portable flash memory storage device integrated with the fdisk command. See also striping and RAID. Network interface controller. parity - PCI - Nonvolatile random-access memory. Millisecond(s). Network Attached Storage. ns - Each partition can contain several...
memory key - mm - NAS - A device that connects to a network. NVRAM - In RAID arrays, a striped hard drive containing parity data. partition - A specific location, usually expressed as integrated memory (ROM and ...called partitions with a USB connector. memory module - A portable flash memory storage device integrated with the fdisk command. See also striping and RAID. Network interface controller. parity - PCI - Nonvolatile random-access memory. Millisecond(s). Network Attached Storage. ns - Each partition can contain several...
Hardware Owner's Manual
Page 126
...or keyboard, connected to servers and storage systems in a rack. Software written for program instructions and data. Remote access controller. RAID - The system's primary temporary storage area for one that provides electrical power to a system. A registered DDR3 memory module.... SCSI. 126 Glossary PDU - Preboot eXecution Environment. SAS - RAC - RAID on your system's boot routine and the POST. Power distribution unit. PXE - Redundant array of RAID include RAID 0, RAID 1, RAID 5, RAID 10, and RAID 50. read -only file is lost when you are arranged in ROM ...
...or keyboard, connected to servers and storage systems in a rack. Software written for program instructions and data. Remote access controller. RAID - The system's primary temporary storage area for one that provides electrical power to a system. A registered DDR3 memory module.... SCSI. 126 Glossary PDU - Preboot eXecution Environment. SAS - RAC - RAID on your system's boot routine and the POST. Power distribution unit. PXE - Redundant array of RAID include RAID 0, RAID 1, RAID 5, RAID 10, and RAID 50. read -only file is lost when you are arranged in ROM ...
Hardware Owner's Manual
Page 127
... interface between the system board and storage devices. SDRAM - sec - SNMP - See also guarding, mirroring, and RAID. Super video graphics array. A BIOS-based program that allows a network manager to identify it when you call Dell for peripherals, and various ROM chips. Simple Network Management Protocol. A virtual disk may use several stripes on...
... interface between the system board and storage devices. SDRAM - sec - SNMP - See also guarding, mirroring, and RAID. Super video graphics array. A BIOS-based program that allows a network manager to identify it when you call Dell for peripherals, and various ROM chips. Simple Network Management Protocol. A virtual disk may use several stripes on...
Hardware Owner's Manual
Page 131
... Mezzanine card installing, 76 removing, 74 A about your system, 11 B backplane installing, 88 removing, 86 batteries troubleshooting, 100 battery troubleshooting the RAID card battery, 106 battery (system) installing, 91 removing, 92 BMC LAN configuring, 43 boot menu, 41 Boot Settings configuring, 41 C closing...configuring BMC LAN, 43 boot settings, 41 IDE, 38 memory, 38 processor, 36 remote access, 44 Super IO, 39 USB, 39 contacting Dell, 119 control panel assembly installing, 90 removing, 89 cooling fan installing, 83 removing, 82 cooling fans troubleshooting, 102 cooling shroud, 54 removing...
... Mezzanine card installing, 76 removing, 74 A about your system, 11 B backplane installing, 88 removing, 86 batteries troubleshooting, 100 battery troubleshooting the RAID card battery, 106 battery (system) installing, 91 removing, 92 BMC LAN configuring, 43 boot menu, 41 Boot Settings configuring, 41 C closing...configuring BMC LAN, 43 boot settings, 41 IDE, 38 memory, 38 processor, 36 remote access, 44 Super IO, 39 USB, 39 contacting Dell, 119 control panel assembly installing, 90 removing, 89 cooling fan installing, 83 removing, 82 cooling fans troubleshooting, 102 cooling shroud, 54 removing...
Hardware Owner's Manual
Page 134
...board, 93 S safety, 95 safety Instructions, 47 SAS controller card installing, 73 removing, 72 SAS controller daughter card troubleshooting, 106 SAS RAID controller daughter card troubleshooting, 106 security menu, 45 server menu, 42 start menu, 33 startup accessing system features, 11 super IO configuring,... 39 support contacting Dell, 119 system closing, 54 opening, 53 system board, 93 installing, 94 removing, 93 system cooling troubleshooting, 102 system cover installing, ...
...board, 93 S safety, 95 safety Instructions, 47 SAS controller card installing, 73 removing, 72 SAS controller daughter card troubleshooting, 106 SAS RAID controller daughter card troubleshooting, 106 security menu, 45 server menu, 42 start menu, 33 startup accessing system features, 11 super IO configuring,... 39 support contacting Dell, 119 system closing, 54 opening, 53 system board, 93 installing, 94 removing, 93 system cooling troubleshooting, 102 system cover installing, ...
Hardware Owner's Manual
Page 135
expansion card, 107 external connections, 96, 110 hard drive, 105 keyboard, 96 memory, 103 NIC, 98 processors, 108 SAS RAID controller daughter card, 106 sequence, 95 system cooling, 102 video, 96 wet system, 99 U USB configuring, 39 front-panel connectors, 13 V video troubleshooting, 96 W wet system troubleshooting, 99 Index 135
expansion card, 107 external connections, 96, 110 hard drive, 105 keyboard, 96 memory, 103 NIC, 98 processors, 108 SAS RAID controller daughter card, 106 sequence, 95 system cooling, 102 video, 96 wet system, 99 U USB configuring, 39 front-panel connectors, 13 V video troubleshooting, 96 W wet system troubleshooting, 99 Index 135