User's Guide
Page 31
IPv4 Routing Features Address Resolution Protocol The PowerConnect 8024/8024F uses the ARP protocol to solicit and ... have limited resources. Additionally, the administrator can be propagated throughout the regular OSPF area; OSPF internal and external route information may expire, and can statically add entries in the network topology without ... stub areas is an extension to BootP allowing additional setup parameters to be transmitted on each relevant port are multiple routers. Virtual Routing Redundancy Protocol Virtual Routing Redundancy Protocol (VRRP) is received, and ...
IPv4 Routing Features Address Resolution Protocol The PowerConnect 8024/8024F uses the ARP protocol to solicit and ... have limited resources. Additionally, the administrator can be propagated throughout the regular OSPF area; OSPF internal and external route information may expire, and can statically add entries in the network topology without ... stub areas is an extension to BootP allowing additional setup parameters to be transmitted on each relevant port are multiple routers. Virtual Routing Redundancy Protocol Virtual Routing Redundancy Protocol (VRRP) is received, and ...
User's Guide
Page 183
...control tcpflag dos-control tcpfrag ip icmp echo-reply ip icmp error-interval ip icmp unreachables ip icmp redirects ipv6 icmp error-internal ipv6 unreachables show dos-control Description Enables Minimum TCP Header Size Denial of ICMP Echo Reply messages. Configuring System Information 183... Enables the generation of Service ICMP - Enabling L4 Port DoS prevention causes the switch to ECHO_REQ (ping) and a size greater than the configured ICMP packet size (ICMP Pkt Size). ...
...control tcpflag dos-control tcpfrag ip icmp echo-reply ip icmp error-interval ip icmp unreachables ip icmp redirects ipv6 icmp error-internal ipv6 unreachables show dos-control Description Enables Minimum TCP Header Size Denial of ICMP Echo Reply messages. Configuring System Information 183... Enables the generation of Service ICMP - Enabling L4 Port DoS prevention causes the switch to ECHO_REQ (ping) and a size greater than the configured ICMP packet size (ICMP Pkt Size). ...
User's Guide
Page 245
... consists of the switch. • Trap - Advantages of the whole network. • The collector can analyze traffic patterns for analysis. they are found in the internal buffer. TCP/IP, IPX, Ethernet, AppleTalk...), which this function, see the Syslog Commands chapter in the network (statistical model means loss is required. • Log... network activity, enabling effective management and control of the switch continuously with the trap. The following : • It is possible to decode and understand all ports of network resources.
... consists of the switch. • Trap - Advantages of the whole network. • The collector can analyze traffic patterns for analysis. they are found in the internal buffer. TCP/IP, IPX, Ethernet, AppleTalk...), which this function, see the Syslog Commands chapter in the network (statistical model means loss is required. • Log... network activity, enabling effective management and control of the switch continuously with the trap. The following : • It is possible to decode and understand all ports of network resources.
User's Guide
Page 326
...new value for the switch. 326 Configuring Switching Information Enables Portfast mode on all ports. Display the spanning-tree configuration. Display spanning tree settings and parameters for the common and internal spanning tree. Configures the spanning-tree bridge forward time, which is allowed to.... Configures the spanning-tree protocol type. Enables loop guard on spanningtree ports in the listening and learning states before entering the forwarding state. Allows flooding of time a port remains in portfast mode. Configures the spanning-tree priority. Discards BPDUs ...
...new value for the switch. 326 Configuring Switching Information Enables Portfast mode on all ports. Display the spanning-tree configuration. Display spanning tree settings and parameters for the common and internal spanning tree. Configures the spanning-tree bridge forward time, which is allowed to.... Configures the spanning-tree protocol type. Enables loop guard on spanningtree ports in the listening and learning states before entering the forwarding state. Allows flooding of time a port remains in portfast mode. Configures the spanning-tree priority. Discards BPDUs ...
User's Guide
Page 337
...to provide to the LAN. - Indicates the port or LAG through which the designated switch is internal to the root. • Designated Port ID - Backup ports occur only when two ports are : - Defines the interface priority for this MSTP instance. • Port State - The default value is 1-15. ...8226; Interface - Displays the port ID number on the ...
...to provide to the LAN. - Indicates the port or LAG through which the designated switch is internal to the root. • Designated Port ID - Backup ports occur only when two ports are : - Defines the interface priority for this MSTP instance. • Port State - The default value is 1-15. ...8226; Interface - Displays the port ID number on the ...
User's Guide
Page 458
... Displays number of late collisions received on the selected interface. • Late Collisions - Displays the total number of internal MAC received errors on the selected interface. • Oversize Packets - Select physical interface (unit, port) or LAG interface for which statistics is No Refresh. • Frame Check Sequence (FCS) Errors - Displays number of...
... Displays number of late collisions received on the selected interface. • Late Collisions - Displays the total number of internal MAC received errors on the selected interface. • Oversize Packets - Select physical interface (unit, port) or LAG interface for which statistics is No Refresh. • Frame Check Sequence (FCS) Errors - Displays number of...
User's Guide
Page 569
Table 9-35. VLAN Routing You can configure PowerConnect 8024/8024F software with a VLAN. To display the page, click Routing →VLAN Routing →Summary in the VLAN, plus the internal bridgerouter interface, if it was received on a routed VLAN. The following web page is accessible from this ...page to display the VLAN routing summary. It could also be treated as if the VLAN were a router port. This section shows how to configure the PowerConnect 8024/8024F software to search the MAC address table. You can be used when a VLAN spans multiple physical networks,...
Table 9-35. VLAN Routing You can configure PowerConnect 8024/8024F software with a VLAN. To display the page, click Routing →VLAN Routing →Summary in the VLAN, plus the internal bridgerouter interface, if it was received on a routed VLAN. The following web page is accessible from this ...page to display the VLAN routing summary. It could also be treated as if the VLAN were a router port. This section shows how to configure the PowerConnect 8024/8024F software to search the MAC address table. You can be used when a VLAN spans multiple physical networks,...
User's Guide
Page 687
The priority of the ingress port. Although the hardware supports eight queues, one of service is assigned to trust one queue is always reserved for internal use , so there are not required. The Class of Service menu page contains links to the following features: • Mapping... Table Configuration • Interface Configuration • Interface Queue Configuration Mapping Table Configuration Each port in the tree view. This...
The priority of the ingress port. Although the hardware supports eight queues, one of service is assigned to trust one queue is always reserved for internal use , so there are not required. The Class of Service menu page contains links to the following features: • Mapping... Table Configuration • Interface Configuration • Interface Queue Configuration Mapping Table Configuration Each port in the tree view. This...
User's Guide
Page 691
...show classofservice trust show interfaces cos-queue Description Maps an 802.1p priority to internal traffic classes for a specific interface. Displays the current IP DSCP mapping to an internal traffic class for this function, see the following table summarizes the equivalent CLI commands...shaping rate to an internal traffic class. Displays the class-of Service →Interface Configuration in the CLI Reference Guide: • QoS Commands The following chapter in the tree view. Interface Configuration Use the Interface Configuration page to specify ports individually for a ...
...show classofservice trust show interfaces cos-queue Description Maps an 802.1p priority to internal traffic classes for a specific interface. Displays the current IP DSCP mapping to an internal traffic class for this function, see the following table summarizes the equivalent CLI commands...shaping rate to an internal traffic class. Displays the class-of Service →Interface Configuration in the CLI Reference Guide: • QoS Commands The following chapter in the tree view. Interface Configuration Use the Interface Configuration page to specify ports individually for a ...
CLI Reference Guide
Page 67
... mode of the traffic class through subsequent policy attribute statements. interface range port-channel Enters the interface configuration mode to an internal traffic class for the purpose of defining treatment of a specific GC port-channel. Port Monitor Command Description monitor session Configures a port monitoring session. Defines a new DiffServ class of each Mode abbreviation, see "Mode...
... mode of the traffic class through subsequent policy attribute statements. interface range port-channel Enters the interface configuration mode to an internal traffic class for the purpose of defining treatment of a specific GC port-channel. Port Monitor Command Description monitor session Configures a port monitoring session. Defines a new DiffServ class of each Mode abbreviation, see "Mode...
CLI Reference Guide
Page 69
.... show classofservice ip-dscpmapping Displays the current IP DSCP mapping to internal traffic PE classes for the associated traffic PCMC stream are redirected to a specific egress interface (physical port or port-channel). show classofservice dotlp-mapping Displays the current Dot1p (802.1p...) priority mapping to PE internal traffic classes for the specified PE class. CMC match protocol Adds to...
.... show classofservice ip-dscpmapping Displays the current IP DSCP mapping to internal traffic PE classes for the associated traffic PCMC stream are redirected to a specific egress interface (physical port or port-channel). show classofservice dotlp-mapping Displays the current Dot1p (802.1p...) priority mapping to PE internal traffic classes for the specified PE class. CMC match protocol Adds to...
CLI Reference Guide
Page 72
...configuration name. MC show spanning-tree summary Displays spanning tree settings and parameters for the common and internal spanning tree. GC spanning-tree auto-portfast Sets the port to an MST instance. GC spanning-tree max-age Configures the spanning tree bridge maximum age....region by entering the GC multiple spanning-tree (MST) mode. spanning-tree mst 0 external-cost Sets the external cost for a port. PE show spanning-tree Displays spanning tree configuration. spanning tree Enables spanning-tree functionality. exit (mst) Exits the MST configuration mode...
...configuration name. MC show spanning-tree summary Displays spanning tree settings and parameters for the common and internal spanning tree. GC spanning-tree auto-portfast Sets the port to an MST instance. GC spanning-tree max-age Configures the spanning tree bridge maximum age....region by entering the GC multiple spanning-tree (MST) mode. spanning-tree mst 0 external-cost Sets the external cost for a port. PE show spanning-tree Displays spanning tree configuration. spanning tree Enables spanning-tree functionality. exit (mst) Exits the MST configuration mode...
CLI Reference Guide
Page 101
... Service protection. ip icmp error-interval Limits the rate at which IPv4 ICMP error messages are sent. IC ipv6 icmp error-internal Limits the rate at which ICMPv6 error messages are sent. LC history Enables the command history function. dos-control l4port Enables L4... Port Denial of Service protections. Command Groups 101 line Identifies a specific line for user input. GC dos-control sipdip Enables Source IP Address ...
... Service protection. ip icmp error-interval Limits the rate at which IPv4 ICMP error messages are sent. IC ipv6 icmp error-internal Limits the rate at which ICMPv6 error messages are sent. LC history Enables the command history function. dos-control l4port Enables L4... Port Denial of Service protections. Command Groups 101 line Identifies a specific line for user input. GC dos-control sipdip Enables Source IP Address ...
CLI Reference Guide
Page 107
...Mode abbreviation, see "Mode Types" on page 51. logging on GC the console. GC port Specifies the port number of logging and the syslog messages stored PE in the internal buffer. GC Specifies or modifies the switch host name. show logging Displays the state of the... the state of syslog messages. L show syslog-servers Displays the syslog servers settings. PE clear logging file Clears messages from the internal logging buffer. PE description Describes the syslog server. L loggin cli-command Enable CLI command logging GC logging Logs messages to a lower...
...Mode abbreviation, see "Mode Types" on page 51. logging on GC the console. GC port Specifies the port number of logging and the syslog messages stored PE in the internal buffer. GC Specifies or modifies the switch host name. show logging Displays the state of the... the state of syslog messages. L show syslog-servers Displays the syslog servers settings. PE clear logging file Clears messages from the internal logging buffer. PE description Describes the syslog server. L loggin cli-command Enable CLI command logging GC logging Logs messages to a lower...
CLI Reference Guide
Page 133
If it does exist, it is flagged. Referencing External/Internal File systems Configuration or software images are reserved and may not be removed or added. identifies the file available on a remote file system accessible through ... interface security measures implemented by the command. The user may not be used to refer to software images. It is a simplified FTP and uses a UDP port instead of these special files and the source file has an attached file description, it to the startup-config file. • startup-config - These files...
If it does exist, it is flagged. Referencing External/Internal File systems Configuration or software images are reserved and may not be removed or added. identifies the file available on a remote file system accessible through ... interface security measures implemented by the command. The user may not be used to refer to software images. It is a simplified FTP and uses a UDP port instead of these special files and the source file has an attached file description, it to the startup-config file. • startup-config - These files...
CLI Reference Guide
Page 134
...8226; The serial session defaults to log in to configure primary and secondary authentication servers. This requirement applies only when the user is saved internally in encrypted format and never appears in clear text anywhere on the CLI. • The CLI supports TACACS+ and RADIUS authentication servers.... • The CLI allows the user to a local serial port even if the remote authentication server(s) are down. In this case, CLI reverts to using local user accounts when the remote authentication servers ...
...8226; The serial session defaults to log in to configure primary and secondary authentication servers. This requirement applies only when the user is saved internally in encrypted format and never appears in clear text anywhere on the CLI. • The CLI supports TACACS+ and RADIUS authentication servers.... • The CLI allows the user to a local serial port even if the remote authentication server(s) are down. In this case, CLI reverts to using local user accounts when the remote authentication servers ...
CLI Reference Guide
Page 179
... count Capacity: 8192 Used: 109 Static addresses: 2 Secure addresses: 1 Dynamic addresses: 97 Internal addresses: 9 show bridge address-table static Use the show bridge address-table static [vlan vlan] [ethernet interface|port-channel port-channelnumber] • vlan - A valid Ethernet port. Specifies a valid port-channel-number Default Configuration This command has no user guidelines. Specific valid VLAN...
... count Capacity: 8192 Used: 109 Static addresses: 2 Secure addresses: 1 Dynamic addresses: 97 Internal addresses: 9 show bridge address-table static Use the show bridge address-table static [vlan vlan] [ethernet interface|port-channel port-channelnumber] • vlan - A valid Ethernet port. Specifies a valid port-channel-number Default Configuration This command has no user guidelines. Specific valid VLAN...
CLI Reference Guide
Page 246
... Example #1 The following example displays traffic seen by the physical interface: console>show interfaces counters Port InOctets InUcastPkts 1/g1 183892 1289 3/g1 123899 1788 Port OutOctets OutUcastPkts 1/g1 9188 9 2/g1 0 0 3/g1 8789 27 Ch InOctets InUcastPkts 1 ...27889 928 246 Ethernet Configuration Commands Counted MAC Control frames transmitted on the specified ethernet or port-channel interface. Field Oversize Packets Internal MAC Rx Errors Received Pause Frames Transmitted Pause Frames Received PFC Frames Transmitted PFC Frames Description ...
... Example #1 The following example displays traffic seen by the physical interface: console>show interfaces counters Port InOctets InUcastPkts 1/g1 183892 1289 3/g1 123899 1788 Port OutOctets OutUcastPkts 1/g1 9188 9 2/g1 0 0 3/g1 8789 27 Ch InOctets InUcastPkts 1 ...27889 928 246 Ethernet Configuration Commands Counted MAC Control frames transmitted on the specified ethernet or port-channel interface. Field Oversize Packets Internal MAC Rx Errors Received Pause Frames Transmitted Pause Frames Received PFC Frames Transmitted PFC Frames Description ...
CLI Reference Guide
Page 247
.... Ethernet Configuration Commands 247 console#show interfaces counters ethernet 1/g1 Port InOctets InUcastPkts 1/g1 183892 1289 Port OutOctets 1/g1 9188 OutUcastPkts --------9 Alignment Errors: 17 FCS Errors: 8 Single Collision Frames: 0 Multiple Collision Frames: 0 Deferred Transmissions: 0 Late Collisions: 0 Excessive Collisions: 0 Oversize Packets: 0 Internal MAC Rx Errors: 0 Received Pause Frames: 0 Transmitted Pause Frames: 0 Example #3 The following...
.... Ethernet Configuration Commands 247 console#show interfaces counters ethernet 1/g1 Port InOctets InUcastPkts 1/g1 183892 1289 Port OutOctets 1/g1 9188 OutUcastPkts --------9 Alignment Errors: 17 FCS Errors: 8 Single Collision Frames: 0 Multiple Collision Frames: 0 Deferred Transmissions: 0 Late Collisions: 0 Excessive Collisions: 0 Oversize Packets: 0 Internal MAC Rx Errors: 0 Received Pause Frames: 0 Transmitted Pause Frames: 0 Example #3 The following...
CLI Reference Guide
Page 248
... display traffic seen by the interface, including Received Priority Flow Control (PFC) Frames and Transmitted PFC Frames for the given port channel interface. console#show interfaces counters ethernet 1/xg1 Ch InOctets InUcastPkts InMcastPkts InBcastPkts 1/xg1 273 438 164 341 Ch OutOctets ... Errors 56 FCS Errors 16 Single Collision Frames 21 Multiple Collision Frames 51 Late Collisions 7 Excessive Collisions 1 Oversize Packets 25 Internal MAC Rx Errors 318 Received Pause Frames 517 Transmitted Pause Frames 362 Received PFC Frames 117 Transmitted PFC Frames 214 Example #4...
... display traffic seen by the interface, including Received Priority Flow Control (PFC) Frames and Transmitted PFC Frames for the given port channel interface. console#show interfaces counters ethernet 1/xg1 Ch InOctets InUcastPkts InMcastPkts InBcastPkts 1/xg1 273 438 164 341 Ch OutOctets ... Errors 56 FCS Errors 16 Single Collision Frames 21 Multiple Collision Frames 51 Late Collisions 7 Excessive Collisions 1 Oversize Packets 25 Internal MAC Rx Errors 318 Received Pause Frames 517 Transmitted Pause Frames 362 Received PFC Frames 117 Transmitted PFC Frames 214 Example #4...