User's Guide
Page 21
Trivial File Transfer Protocol (TFTP) The PowerConnect 8024/8024F switches support boot image, firmware, and configuration upload or download through TFTP. Simple Network Management Protocol (SNMP) Versions 1, 2, and 3 The system is supported. SNMP v1/v2c/v3 over the UDP...and Reboot." For information about SNTP, see "Managing Logs." Time synchronization is composed of the system state, and the SNMP protocol to set of backup firmware images. Real Time Clock The Real Time Clock feature allows the user to examine and possibly modify these values. Remote Monitoring (RMON) RMON is a ...
Trivial File Transfer Protocol (TFTP) The PowerConnect 8024/8024F switches support boot image, firmware, and configuration upload or download through TFTP. Simple Network Management Protocol (SNMP) Versions 1, 2, and 3 The system is supported. SNMP v1/v2c/v3 over the UDP...and Reboot." For information about SNTP, see "Managing Logs." Time synchronization is composed of the system state, and the SNMP protocol to set of backup firmware images. Real Time Clock The Real Time Clock feature allows the user to examine and possibly modify these values. Remote Monitoring (RMON) RMON is a ...
User's Guide
Page 229
... PEM File - Choose this option to download. If the file has errors the update will be downloaded. Trivial File Transfer Protocol - Possible filetypes are: • Firmware - Select the file transfer mode for the configuration to update the switch's configuration. SSH-2 Digital Signature Algorithm (DSA) Key File (PEM Encoded) NOTE: To download...
... PEM File - Choose this option to download. If the file has errors the update will be downloaded. Trivial File Transfer Protocol - Possible filetypes are: • Firmware - Select the file transfer mode for the configuration to update the switch's configuration. SSH-2 Digital Signature Algorithm (DSA) Key File (PEM Encoded) NOTE: To download...
User's Guide
Page 231
... Upload Use the File Upload to Server page to upload configuration (ASCII), image (binary), operational log, and startup log files from a source to the server. Firmware - Uploads the configuration file. Startup Log - Possible filetypes are : - Uploads the active image. - Operational Log - SFTP - File Upload to Server The File Upload to Server...
... Upload Use the File Upload to Server page to upload configuration (ASCII), image (binary), operational log, and startup log files from a source to the server. Firmware - Uploads the configuration file. Startup Log - Possible filetypes are : - Uploads the active image. - Operational Log - SFTP - File Upload to Server The File Upload to Server...
User's Guide
Page 233
... - Startup Config - Figure 6-110. All units in the tree view. The configuration source file from the menu one of the following fields: • Copy Master Firmware -
... - Startup Config - Figure 6-110. All units in the tree view. The configuration source file from the menu one of the following fields: • Copy Master Firmware -
User's Guide
Page 300
... a 10000 mbps speed and full-duplex mode setting. • LAG - Indicates the statue of a LAG. • Current Flow Control - The firmware status is active. - Select a unit and port in only one direction at a time. • Current Duplex Mode - Click Apply Changes. Displays...abilities to its partner. • Current Auto Negotiation - Outdated - Define the available fields on 10GBase-T non-stacking ports. • Image Firmware Version - The port parameters are : - Indicates that the interface supports transmission between two link partners that the port is not current. •...
... a 10000 mbps speed and full-duplex mode setting. • LAG - Indicates the statue of a LAG. • Current Flow Control - The firmware status is active. - Select a unit and port in only one direction at a time. • Current Duplex Mode - Click Apply Changes. Displays...abilities to its partner. • Current Auto Negotiation - Outdated - Define the available fields on 10GBase-T non-stacking ports. • Image Firmware Version - The port parameters are : - Indicates that the interface supports transmission between two link partners that the port is not current. •...
User's Guide
Page 413
...following information displays: - Source - Specifies PD port power priority. Vlan Id - Manufacturer Name - Specifies Software version. - Firmware Revisions - If the local device is present in LLDP frames, the following information displays: - Specifies available power sourcing equipment's...of local device. - Source - Specifies the priority associated with a particular policy type. - Specifies model name. - Specifies Firmware version. - Specifies asset id. • Location Information - Location Information - Priority - Specifies required power device power value in...
...following information displays: - Source - Specifies PD port power priority. Vlan Id - Manufacturer Name - Specifies Software version. - Firmware Revisions - If the local device is present in LLDP frames, the following information displays: - Specifies available power sourcing equipment's...of local device. - Source - Specifies the priority associated with a particular policy type. - Specifies model name. - Specifies Firmware version. - Specifies asset id. • Location Information - Location Information - Priority - Specifies required power device power value in...
User's Guide
Page 415
... Specifies the software version of the remote device. • Location Information - Manufacturer Name - Model Name - DSCP - Unknown Bit Status - Firmware Revisions - Specifies the model name of the remote device. - Specifies the type of the remote device. - Tagged Bit Status - Specifies the... VLAN ID associated with a particular policy type. - Specifies the firmware version of the remote device. - Serial Number - Network Application - A port may receive one or more application types, which include ...
... Specifies the software version of the remote device. • Location Information - Manufacturer Name - Model Name - DSCP - Unknown Bit Status - Firmware Revisions - Specifies the model name of the remote device. - Specifies the type of the remote device. - Tagged Bit Status - Specifies the... VLAN ID associated with a particular policy type. - Specifies the firmware version of the remote device. - Serial Number - Network Application - A port may receive one or more application types, which include ...
CLI Reference Guide
Page 241
... autonegotiation by a space: 100f, 1000f and 10000f. Both 1000f and 10000f are not currently supported. NOTE: Manual port speed configuration is enabled by PC8024/PC8024F firmware. Specify one or more of the following error message: console(config-if-1/xg17)#no negotiation' command to limit auto-negotiation capabilities.
... autonegotiation by a space: 100f, 1000f and 10000f. Both 1000f and 10000f are not currently supported. NOTE: Manual port speed configuration is enabled by PC8024/PC8024F firmware. Specify one or more of the following error message: console(config-if-1/xg17)#no negotiation' command to limit auto-negotiation capabilities.
CLI Reference Guide
Page 366
LLDP MED Local Device Detail Interface: 1/0/8 Network Policies Media Policy Application Type : voice Vlan ID: 10 Priority: 5 DSCP: 1 Unknown: False Tagged: True Media Policy Application Type : streamingvideo Vlan ID: 20 Priority: 1 DSCP: 2 Unknown: False Tagged: True Inventory Hardware Rev: xxx xxx xxx Firmware Rev: xxx xxx xxx Software Rev: xxx xxx xxx Serial Num: xxx xxx xxx Mfg Name: xxx xxx xxx Model Name: xxx xxx xxx Asset ID: xxx xxx xxx Location Subtype: elin 366 LLDP Commands
LLDP MED Local Device Detail Interface: 1/0/8 Network Policies Media Policy Application Type : voice Vlan ID: 10 Priority: 5 DSCP: 1 Unknown: False Tagged: True Media Policy Application Type : streamingvideo Vlan ID: 20 Priority: 1 DSCP: 2 Unknown: False Tagged: True Inventory Hardware Rev: xxx xxx xxx Firmware Rev: xxx xxx xxx Software Rev: xxx xxx xxx Serial Num: xxx xxx xxx Mfg Name: xxx xxx xxx Model Name: xxx xxx xxx Asset ID: xxx xxx xxx Location Subtype: elin 366 LLDP Commands
CLI Reference Guide
Page 369
Vlan ID: 10 Priority: 5 DSCP: 1 Unknown: False Tagged: True Media Policy Application Type : streamingvideo Vlan ID: 20 Priority: 1 DSCP: 2 Unknown: False Tagged: True Inventory Hardware Rev: xxx xxx xxx Firmware Rev: xxx xxx xxx Software Rev: xxx xxx xxx Serial Num: xxx xxx xxx Mfg Name: xxx xxx xxx Model Name: xxx xxx xxx Asset ID: xxx xxx xxx Location Subtype: elin Info: xxx xxx xxx Extended POE Device Type: pseDevice LLDP Commands 369
Vlan ID: 10 Priority: 5 DSCP: 1 Unknown: False Tagged: True Media Policy Application Type : streamingvideo Vlan ID: 20 Priority: 1 DSCP: 2 Unknown: False Tagged: True Inventory Hardware Rev: xxx xxx xxx Firmware Rev: xxx xxx xxx Software Rev: xxx xxx xxx Serial Num: xxx xxx xxx Mfg Name: xxx xxx xxx Model Name: xxx xxx xxx Asset ID: xxx xxx xxx Location Subtype: elin Info: xxx xxx xxx Extended POE Device Type: pseDevice LLDP Commands 369