Statement of Volatility
Page 1
... modules and will be between 2GB to lose data) N/A Non Volatile memory, 64Mbit No N/A (8MB), System BIOS and Video BIOS for correct operation of Volatility - Non-Volatile EEPROM No memory. 2Kbit (256 bytes) One Device present on the Dell OptiPlex 3010 motherboard: Description Reference Designator Embedded U36 Flash memory in embedded controller SMSC5514E System U30...
... modules and will be between 2GB to lose data) N/A Non Volatile memory, 64Mbit No N/A (8MB), System BIOS and Video BIOS for correct operation of Volatility - Non-Volatile EEPROM No memory. 2Kbit (256 bytes) One Device present on the Dell OptiPlex 3010 motherboard: Description Reference Designator Embedded U36 Flash memory in embedded controller SMSC5514E System U30...
Guidebook
Page 2
... System Dimensions (Physical) System Expansion Slots System Level Environmental and Operating Conditions Power Audio Communications Graphics/Video Controller Hard Drives Optical Drive Media Card Reader BIOS Defaults Chassis Enclosure and Ventilation Requirements Acoustic Noise Emission Information 3-4 5-6 7-8 9 10 11 12 13 14 14 15 16 16 17 18-19 20 20-25...
... System Dimensions (Physical) System Expansion Slots System Level Environmental and Operating Conditions Power Audio Communications Graphics/Video Controller Hard Drives Optical Drive Media Card Reader BIOS Defaults Chassis Enclosure and Ventilation Requirements Acoustic Noise Emission Information 3-4 5-6 7-8 9 10 11 12 13 14 14 15 16 16 17 18-19 20 20-25...
Guidebook
Page 9
...® Linux (32bit) Optional CHIPSET Chipset Non-volatile memory on chipset BIOS Configuration SPI (Serial Peripheral Interface) NIC EEPROM MT DT SFF Intel H61 Express Chipset 64Mbit (8MB) located at SPI_FLASH on chipset LOM configuration contained within SPI_FLASH - DELL™ OPTIPLEX™ 3010 TECHNICAL GUIDEBOOK -FINAL MARKETING SYSTEM CONFIGURATIONS N O T E : O ff e r i n g s m a y v a r y b y c o u n t r y . F o r m o r e i n f o r m a t i o n r e g a r d i n g t h e c o n fi g u r a t i o n o f y o u r c o m p u t e r , c l i c k Start>Help and...
...® Linux (32bit) Optional CHIPSET Chipset Non-volatile memory on chipset BIOS Configuration SPI (Serial Peripheral Interface) NIC EEPROM MT DT SFF Intel H61 Express Chipset 64Mbit (8MB) located at SPI_FLASH on chipset LOM configuration contained within SPI_FLASH - DELL™ OPTIPLEX™ 3010 TECHNICAL GUIDEBOOK -FINAL MARKETING SYSTEM CONFIGURATIONS N O T E : O ff e r i n g s m a y v a r y b y c o u n t r y . F o r m o r e i n f o r m a t i o n r e g a r d i n g t h e c o n fi g u r a t i o n o f y o u r c o m p u t e r , c l i c k Start>Help and...
Guidebook
Page 34
DELL™ OPTIPLEX™ 3010 TECHNICAL GUIDEBOOK -FINAL BIOS DEFAULTS System Configuration Integrated NIC: SATA Operation: Drives: SMART Reporting: USB Controller: Miscellaneous Devices: Video Performance Virtualization Support Security Power Management Maintenance POST Behavior Multi-...
DELL™ OPTIPLEX™ 3010 TECHNICAL GUIDEBOOK -FINAL BIOS DEFAULTS System Configuration Integrated NIC: SATA Operation: Drives: SMART Reporting: USB Controller: Miscellaneous Devices: Video Performance Virtualization Support Security Power Management Maintenance POST Behavior Multi-...
Owners Manual
Page 33
... - The benefit here is that you do not have trouble entering System Setup using this key, press when the keyboard LEDs first flash. NOTE: The BIOS features an option to a specific device (for example: floppy, CD-ROM, or hard drive). 3 System Setup System Setup This computer offers you the... boot and diagnostics utility menu one -time boot menu by pressing Press to enter System Setup and make changes to use the keystroke on the BIOS splash screen (see image below). When you have to the Utility Partition. Not only is not "hidden". • Diagnostics options - The boot ...
... - The benefit here is that you do not have trouble entering System Setup using this key, press when the keyboard LEDs first flash. NOTE: The BIOS features an option to a specific device (for example: floppy, CD-ROM, or hard drive). 3 System Setup System Setup This computer offers you the... boot and diagnostics utility menu one -time boot menu by pressing Press to enter System Setup and make changes to use the keystroke on the BIOS splash screen (see image below). When you have to the Utility Partition. Not only is not "hidden". • Diagnostics options - The boot ...
Owners Manual
Page 34
...have failed at checkpoint ______. Timing Key Sequences The keyboard is already warmed up. If this checkpoint and contact Dell Technical Support. If the BIOS determine the previous boot was unsuccessful, it displays an error message similar to the following keystrokes to know that this... keyboard error message appears on the first method-the keyboard lights-to navigate the BIOS screens: Action Keystroke Expand and collapse field , left- Beep Codes and Text Error Messages The OptiPlex BIOS is capable of displaying error messages in the top right-hand corner of opportunity before...
...have failed at checkpoint ______. Timing Key Sequences The keyboard is already warmed up. If this checkpoint and contact Dell Technical Support. If the BIOS determine the previous boot was unsuccessful, it displays an error message similar to the following keystrokes to know that this... keyboard error message appears on the first method-the keyboard lights-to navigate the BIOS screens: Action Keystroke Expand and collapse field , left- Beep Codes and Text Error Messages The OptiPlex BIOS is capable of displaying error messages in the top right-hand corner of opportunity before...
Owners Manual
Page 35
General Option System Information Description Displays the following information: • System Information: Displays BIOS Version, Service Tag, Asset Tag, Ownership Date, Manufacture Date, and the Express Service Code. • Memory Information: Displays ...8226; PCI Information: Displays SLOT1, SLOT2, SLOT3, SLOT4 • Device Information: Displays SATA-0, SATA-1, SATA-2, SATA-3, and LOM MAC Address. Action Exit BIOS Change a setting Select field to : • Disabled • Enabled (default) • Enabled w/PXE • Enabled w/ImageServer 35 Boot Sequence Allows you...
General Option System Information Description Displays the following information: • System Information: Displays BIOS Version, Service Tag, Asset Tag, Ownership Date, Manufacture Date, and the Express Service Code. • Memory Information: Displays ...8226; PCI Information: Displays SLOT1, SLOT2, SLOT3, SLOT4 • Device Information: Displays SATA-0, SATA-1, SATA-2, SATA-3, and LOM MAC Address. Action Exit BIOS Change a setting Select field to : • Disabled • Enabled (default) • Enabled w/PXE • Enabled w/ImageServer 35 Boot Sequence Allows you...
Owners Manual
Page 37
... are set . After next boot, the setting will always prompt for passwords on Restarts (warm boots). Allows you Activate or Disable the BIOS module interface of the processor. Always prompt for the system and internal HDD password when they are capable of characters allowed for the system....mode of the optional Computrace Service from the off state (a cold boot). This option lets you to Intel RAID (CTRL+I) or Intel Management Engine BIOS Extension (CTRL+P/ F12) • Enable - You can set . Allows you to control the minimum and maximum number of preventing access to ...
... are set . After next boot, the setting will always prompt for passwords on Restarts (warm boots). Allows you Activate or Disable the BIOS module interface of the processor. Always prompt for the system and internal HDD password when they are capable of characters allowed for the system....mode of the optional Computrace Service from the off state (a cold boot). This option lets you to Intel RAID (CTRL+I) or Intel Management Engine BIOS Extension (CTRL+P/ F12) • Enable - You can set . Allows you to control the minimum and maximum number of preventing access to ...
Owners Manual
Page 39
...: When enabled, the fan runs at full speed. This option is enabled by default. Time is Disabled by default. The system boots quickly, unless the BIOS has been updated, memory changed, or the previous POST did not complete. • Thorough - The system does not skip any steps in standard 12-hour...
...: When enabled, the fan runs at full speed. This option is enabled by default. Time is Disabled by default. The system boots quickly, unless the BIOS has been updated, memory changed, or the previous POST did not complete. • Thorough - The system does not skip any steps in standard 12-hour...
Owners Manual
Page 41
System Logs Option BIOS Events Description NOTE: This field is only relevant when the "Integrated NIC" control in the "System Configuration" group is set to "Enabled with ImageServer" and ...
System Logs Option BIOS Events Description NOTE: This field is only relevant when the "Integrated NIC" control in the "System Configuration" group is set to "Enabled with ImageServer" and ...
Owners Manual
Page 45
... and re-start the computer. Power Button Problem Description Troubleshooting Steps LED Power connector not installed properly. Power Button 45 Problem Description Troubleshooting Steps LED BIOS may be corrupt or missing. Power Button Problem Description Troubleshooting Steps LED A possible system board failure has occurred. If the computer boots, add the peripheral... and PCI-E slots and re-start the computer. Remove all peripheral cards from the power supply unit. The computer hardware is operating normally but the BIOS may be corrupt or missing.
... and re-start the computer. Power Button Problem Description Troubleshooting Steps LED Power connector not installed properly. Power Button 45 Problem Description Troubleshooting Steps LED BIOS may be corrupt or missing. Power Button Problem Description Troubleshooting Steps LED A possible system board failure has occurred. If the computer boots, add the peripheral... and PCI-E slots and re-start the computer. Remove all peripheral cards from the power supply unit. The computer hardware is operating normally but the BIOS may be corrupt or missing.
Owners Manual
Page 49
... Code Cause 3-1-2 Master DMA register failure Code Cause 3-1-3 Master interrupt mask register failure Code Cause 3-1-4 Slave interrupt mask register failure 49 If so, BIOS will jump out from a device (optical drive), check system setup to boot from looping and execute the normal shutdown process and power system. •...to ensure the boot sequence is 3 sec, and the beep sound lasts 300 ms. After each beep and each set of beeps, the BIOS should detect if the user presses the power button. Beep Codes The computer can emit a series of beeps during start-up if the display...
... Code Cause 3-1-2 Master DMA register failure Code Cause 3-1-3 Master interrupt mask register failure Code Cause 3-1-4 Slave interrupt mask register failure 49 If so, BIOS will jump out from a device (optical drive), check system setup to boot from looping and execute the normal shutdown process and power system. •...to ensure the boot sequence is 3 sec, and the beep sound lasts 300 ms. After each beep and each set of beeps, the BIOS should detect if the user presses the power button. Beep Codes The computer can emit a series of beeps during start-up if the display...
Owners Manual
Page 51
... is removed. Description The MFG_MODE jumper has been set and AMT Management features are disabled until it is installed. Alert! Contact Dell and report the checkpoint code (nnnn) to complete the boot routine three consecutive times for the same error. Description The computer ... to shadowed memory Code Cause 4-4-3 Math coprocessor test failure Code Cause 4-4-4 Cache test failure Error Messages Address mark not found Description The BIOS found a faulty disk sector or could not find a particular disk sector. Code Cause 4-4-1 Serial or parallel port test failure Code Cause...
... is removed. Description The MFG_MODE jumper has been set and AMT Management features are disabled until it is installed. Alert! Contact Dell and report the checkpoint code (nnnn) to complete the boot routine three consecutive times for the same error. Description The computer ... to shadowed memory Code Cause 4-4-3 Math coprocessor test failure Code Cause 4-4-4 Cache test failure Error Messages Address mark not found Description The BIOS found a faulty disk sector or could not find a particular disk sector. Code Cause 4-4-1 Serial or parallel port test failure Code Cause...
Owners Manual
Page 57
5 Specifications Specification NOTE: Offerings may vary by region. System Information System Chipset DMA Channels Interrupt Levels BIOS Chip (NVRAM) Intel H61 Express Chipset two 82C37 DMA controllers with seven independently programmable channels Integrated I/O APIC capability with 24 interrupts 64 MB (8 MB) Processor ...
5 Specifications Specification NOTE: Offerings may vary by region. System Information System Chipset DMA Channels Interrupt Levels BIOS Chip (NVRAM) Intel H61 Express Chipset two 82C37 DMA controllers with seven independently programmable channels Integrated I/O APIC capability with 24 interrupts 64 MB (8 MB) Processor ...
User Manual
Page 33
... boot and diagnostics utility menu Boot Menu Enhancements The boot menu enhancements are prompted to remember the and keystrokes (although they still work). NOTE: The BIOS features an option to access the menu. • User prompting - When you have to use the keystroke on the... BIOS splash screen (see image below). If you enter the or keystroke correctly, the computer beeps. Keystroke Function one-time boot and diagnostics utility menu one -...
... boot and diagnostics utility menu Boot Menu Enhancements The boot menu enhancements are prompted to remember the and keystrokes (although they still work). NOTE: The BIOS features an option to access the menu. • User prompting - When you have to use the keystroke on the... BIOS splash screen (see image below). If you enter the or keystroke correctly, the computer beeps. Keystroke Function one-time boot and diagnostics utility menu one -...
User Manual
Page 34
... failed at checkpoint ______. or right-arrow key, or +/- Timing Key Sequences The keyboard is already warmed up. Beep Codes and Text Error Messages The OptiPlex BIOS is initialized. Expand or collapse all fields < > 34 Since the one-time boot menu only affects the current boot, it has the added benefit of... cannot restart the system with beep codes. There are two ways to restore the customer's boot order after completing troubleshooting. If this checkpoint and contact Dell Technical Support.
... failed at checkpoint ______. or right-arrow key, or +/- Timing Key Sequences The keyboard is already warmed up. Beep Codes and Text Error Messages The OptiPlex BIOS is initialized. Expand or collapse all fields < > 34 Since the one-time boot menu only affects the current boot, it has the added benefit of... cannot restart the system with beep codes. There are two ways to restore the customer's boot order after completing troubleshooting. If this checkpoint and contact Dell Technical Support.
User Manual
Page 35
Action Exit BIOS Change a setting Select field to enable or disable the integrated network card. Table 1. System Configuration Option Integrated NIC Description Allows you to : • Disabled • ... devices, the items listed in this section may or may not appear. General Option System Information Description Displays the following information: • System Information: Displays BIOS Version, Service Tag, Asset Tag, Ownership Date, Manufacture Date, and the Express Service Code. • Memory Information: Displays Memory Installed, Memory Available, Memory Speed, Memory...
Action Exit BIOS Change a setting Select field to enable or disable the integrated network card. Table 1. System Configuration Option Integrated NIC Description Allows you to : • Disabled • ... devices, the items listed in this section may or may not appear. General Option System Information Description Displays the following information: • System Information: Displays BIOS Version, Service Tag, Asset Tag, Ownership Date, Manufacture Date, and the Express Service Code. • Memory Information: Displays Memory Installed, Memory Available, Memory Speed, Memory...
User Manual
Page 37
...Deactivate - This option is enabled by default. • Disable • Activate Allows you to Intel RAID (CTRL+I) or Intel Management Engine BIOS Extension (CTRL+P/ F12) • Enable - This option is disabled by default. Option Strong Password Password Configuration Password Bypass Password Changes Computrace... Chassis Intrusion CPU XD Support OROM Keyboard Access Admin Setup Lockout Description This option lets you Activate or Disable the BIOS module interface of the optional Computrace Service from the off state (a cold boot). This option lets you to enable...
...Deactivate - This option is enabled by default. • Disable • Activate Allows you to Intel RAID (CTRL+I) or Intel Management Engine BIOS Extension (CTRL+P/ F12) • Enable - This option is disabled by default. Option Strong Password Password Configuration Password Bypass Password Changes Computrace... Chassis Intrusion CPU XD Support OROM Keyboard Access Admin Setup Lockout Description This option lets you Activate or Disable the BIOS module interface of the optional Computrace Service from the off state (a cold boot). This option lets you to enable...
User Manual
Page 39
... boot process. • Auto - The system does not skip any steps in standard 12-hour format (hour:minutes:seconds). The system boots quickly, unless the BIOS has been updated, memory changed, or the previous POST did not complete. • Thorough -
... boot process. • Auto - The system does not skip any steps in standard 12-hour format (hour:minutes:seconds). The system boots quickly, unless the BIOS has been updated, memory changed, or the previous POST did not complete. • Thorough -
User Manual
Page 41
... IP address for the client. Displays the current license status. Option Client IP Client Subnet Mask Client Gateway License Status Table 11. System Logs Option BIOS Events Description NOTE: This field is only relevant when the "Integrated NIC" control in the "System Configuration" group is set to "Enabled with ImageServer" and...
... IP address for the client. Displays the current license status. Option Client IP Client Subnet Mask Client Gateway License Status Table 11. System Logs Option BIOS Events Description NOTE: This field is only relevant when the "Integrated NIC" control in the "System Configuration" group is set to "Enabled with ImageServer" and...