Product Manual
Page 3
...Link Web Smart Switch User Manual SNMP Settings ...20 System Settings...21 Identifying the Web-based Management Utility 22 Tool Menu ...22 Reset ...22 Configure Backup & Restore...23 Firmware Backup and Upload ...23 System Reboot ...24 Setup Menu...24 System > System Settings ...24 System > Trap Settings ...25 System > Port... ...31 Configuration > IGMP Snooping ...31 Configuration > 802.1D Spanning Tree...33 Configuration > Port Mirroring ...34 Configuration > Power Saving...35 Power over Ethernet (PoE) > PoE Port Settings (Only for DGS-1224TP 35 Power over Ethernet (PoE) ...1 Appendix B -
...Link Web Smart Switch User Manual SNMP Settings ...20 System Settings...21 Identifying the Web-based Management Utility 22 Tool Menu ...22 Reset ...22 Configure Backup & Restore...23 Firmware Backup and Upload ...23 System Reboot ...24 Setup Menu...24 System > System Settings ...24 System > Trap Settings ...25 System > Port... ...31 Configuration > IGMP Snooping ...31 Configuration > 802.1D Spanning Tree...33 Configuration > Port Mirroring ...34 Configuration > Power Saving...35 Power over Ethernet (PoE) > PoE Port Settings (Only for DGS-1224TP 35 Power over Ethernet (PoE) ...1 Appendix B -
Product Manual
Page 11
...security and performance. The SmartConsole easily allows customers to discover multiple D-Link web smart switches with 2 Combo SFP Smart Switch Front Panel Figure 8 - DGS-1216T 16 Port 10/100/1000BaseT with the same L2 network segment connected to the port. 7 If the CPU LED is either sending or receiving data... size requirements. In addition, users can also use of the advanced features include: A Switch for Each Business Size: With three models (16, 24 and 48) Gigabit ports to the switch for fast, reliable data transfer. Also support 802.1p priority queues, enabling users to ...
...security and performance. The SmartConsole easily allows customers to discover multiple D-Link web smart switches with 2 Combo SFP Smart Switch Front Panel Figure 8 - DGS-1216T 16 Port 10/100/1000BaseT with the same L2 network segment connected to the port. 7 If the CPU LED is either sending or receiving data... size requirements. In addition, users can also use of the advanced features include: A Switch for Each Business Size: With three models (16, 24 and 48) Gigabit ports to the switch for fast, reliable data transfer. Also support 802.1p priority queues, enabling users to ...
Product Manual
Page 12
... up in solid light state that the Switch is running on the port. 8 3 Product Introduction D-Link Web Smart Switch User Manual NOTE: On DGS-1216T, the MiniGBIC ports 15F and 16F are shared with normal RJ-45 ports 15T and 16T. When MiniGBIC port is in the normal condition. CPU LED...corresponding port is either sending or receiving data to the default configuration and all changes will remain dark if there is running on the port. These LEDs will remain dark if there is no link/activity on the port. DGS-1224T 24 Port 10/100/1000BaseT with 2 Combo SFP Smart Switch Front ...
... up in solid light state that the Switch is running on the port. 8 3 Product Introduction D-Link Web Smart Switch User Manual NOTE: On DGS-1216T, the MiniGBIC ports 15F and 16F are shared with normal RJ-45 ports 15T and 16T. When MiniGBIC port is in the normal condition. CPU LED...corresponding port is either sending or receiving data to the default configuration and all changes will remain dark if there is running on the port. These LEDs will remain dark if there is no link/activity on the port. DGS-1224T 24 Port 10/100/1000BaseT with 2 Combo SFP Smart Switch Front ...
Product Manual
Page 13
... When the CPU LED is blinking, then the switch is where to connect the AC power cord. Port LED (21F~24F): The port LED will indicate Link/Act of port LED, the Link/Act and PoE LED under the mode button will be lost. DGS-1224T Rear Panel Reset: By pressing the Reset button...48V power to the additional PoE PD inserted. 3 Product Introduction Rear Panel D-Link Web Smart Switch User Manual Figure 11 - DGS-1224TP 24 Port 10/100/1000BaseT PoE with 4 Combo SFP Smart Switch Front Panel Figure 12 - If the CPU LED is link up when the system power resource remain ≦15.4W, in solid ...
... When the CPU LED is blinking, then the switch is where to connect the AC power cord. Port LED (21F~24F): The port LED will indicate Link/Act of port LED, the Link/Act and PoE LED under the mode button will be lost. DGS-1224T Rear Panel Reset: By pressing the Reset button...48V power to the additional PoE PD inserted. 3 Product Introduction Rear Panel D-Link Web Smart Switch User Manual Figure 11 - DGS-1224TP 24 Port 10/100/1000BaseT PoE with 4 Combo SFP Smart Switch Front Panel Figure 12 - If the CPU LED is link up when the system power resource remain ≦15.4W, in solid ...
Product Manual
Page 39
... consumption automatically when the RJ-45 port is enabled. DGS-1224TP works with all ports into port mirroring. 5 Configuration D-Link Web Smart Switch User Manual Selection options for DGS-1224TP) DGS-1224TP supports Power over Category 5 ...port. DGS-1224TP will display the PoE status including, Port Enable, Power Limit, Power (W), Voltage (V), Current (mA), Classification, Port Status. None: Turns off . By reducing power consumption, less heat is over pins 1, 2, 3 and 6. Click "all ports into port mirroring. Ports 1-24 can select From Port / To Port to the Target Port...
... consumption automatically when the RJ-45 port is enabled. DGS-1224TP works with all ports into port mirroring. 5 Configuration D-Link Web Smart Switch User Manual Selection options for DGS-1224TP) DGS-1224TP supports Power over Category 5 ...port. DGS-1224TP will display the PoE status including, Port Enable, Power Limit, Power (W), Voltage (V), Current (mA), Classification, Port Status. None: Turns off . By reducing power consumption, less heat is over pins 1, 2, 3 and 6. Click "all ports into port mirroring. Ports 1-24 can select From Port / To Port to the Target Port...
Product Manual
Page 41
5 Configuration D-Link Web Smart Switch User Manual Note: When there is limited, and therefore excessive bandwidth can be first handled by the switch. The following figure displays the status of Quality of Service priority levels of the IEEE 802.1p ... that require a larger bandwidth or that are untagged, the switch will enforce the PoE port priority management. For example, Port 1 > Port 2 > ... > Port 24. Thus with larger bandwidth, less critical traffic is a system power shortage with the PD, the Switch will assign the priority depending on your configuration. QoS > 802...
5 Configuration D-Link Web Smart Switch User Manual Note: When there is limited, and therefore excessive bandwidth can be first handled by the switch. The following figure displays the status of Quality of Service priority levels of the IEEE 802.1p ... that require a larger bandwidth or that are untagged, the switch will enforce the PoE port priority management. For example, Port 1 > Port 2 > ... > Port 24. Thus with larger bandwidth, less critical traffic is a system power shortage with the PD, the Switch will assign the priority depending on your configuration. QoS > 802...
Product Manual
Page 44
...of time the switch waits for the...port-specific assignments, select the From Ports / To Ports...Link Web Smart Switch User Manual Security > 802.1X Settings Network switches...switch only if periodic re-authentication...switch remains in Wi-Fi wireless networks. 802.1X holds a network port disconnected until authentication is by simply attaching a client PC. Authentication Port: sets primary port...port is either made available to the user, or the user is 80 seconds SuppTimeout: Sets the switch... times that the switch waits for network...switch retransmits an EAP Request packet to the network. Default is...
...of time the switch waits for the...port-specific assignments, select the From Ports / To Ports...Link Web Smart Switch User Manual Security > 802.1X Settings Network switches...switch only if periodic re-authentication...switch remains in Wi-Fi wireless networks. 802.1X holds a network port disconnected until authentication is by simply attaching a client PC. Authentication Port: sets primary port...port is either made available to the user, or the user is 80 seconds SuppTimeout: Sets the switch... times that the switch waits for network...switch retransmits an EAP Request packet to the network. Default is...
Product Manual
Page 50
...: 2M Bytes Port Functions 16, 24 or 48 10/100/1000BaseT ports compliant with the following standards: - Appendix B - Technical Specifications D-Link Web Smart Switch User Manual Appendix B - Technical Specifications Hardware Specifications Key Components / Performance Switching Capacity: - DGS-1248T: 96Gbps Max. DGS-1224TP: 35.7Mpps - DGS-1248T: 71.4Mpps Forwarding Mode: Store and Forward Packet Buffer memory: - DGS-1224T: 512KB - DGS-1224TP: 512KB - DGS-1248T: 1MB...
...: 2M Bytes Port Functions 16, 24 or 48 10/100/1000BaseT ports compliant with the following standards: - Appendix B - Technical Specifications D-Link Web Smart Switch User Manual Appendix B - Technical Specifications Hardware Specifications Key Components / Performance Switching Capacity: - DGS-1248T: 96Gbps Max. DGS-1224TP: 35.7Mpps - DGS-1248T: 71.4Mpps Forwarding Mode: Store and Forward Packet Buffer memory: - DGS-1224T: 512KB - DGS-1224TP: 512KB - DGS-1248T: 1MB...