Software Configuration Guide
Page 40
...Cluster Management Suite (CMS) graphical user interface (GUI) for data applications, and security. - Catalyst 3560 Switch Software Configuration Guide 1-2 78-16156-01 Features Chapter 1 Overview The Catalyst 3560 switches have these features: • Ease-of-Use and Ease-of-Deployment Features, page 1-2 ...8226; Power over Ethernet (PoE) Features, page 1-8 • Monitoring Features, page 1-9 Ease-of-Use and Ease-of-Deployment Features • Express Setup for quickly configuring a switch for the first time with basic IP information, contact information, switch and Telnet passwords, and ...
...Cluster Management Suite (CMS) graphical user interface (GUI) for data applications, and security. - Catalyst 3560 Switch Software Configuration Guide 1-2 78-16156-01 Features Chapter 1 Overview The Catalyst 3560 switches have these features: • Ease-of-Use and Ease-of-Deployment Features, page 1-2 ...8226; Power over Ethernet (PoE) Features, page 1-8 • Monitoring Features, page 1-9 Ease-of-Use and Ease-of-Deployment Features • Express Setup for quickly configuring a switch for the first time with basic IP information, contact information, switch and Telnet passwords, and ...
Software Configuration Guide
Page 46
... multicast feed requested and for power, and grants power only when it is available Catalyst 3560 Switch Software Configuration Guide 1-8 78-16156-01 the switch maintains a power budget, monitors and tracks requests for switches not participating in the multicast to be pruned. Includes support for PIM sparse mode... IP address requests, from DHCP clients Power over Ethernet (PoE) Features • Ability to provide power to connected Cisco pre-standard and IEEE 802.3af-compliant powered devices from all 10/100 Ethernet ports if the switch senses that there is no power on the circuit •...
... multicast feed requested and for power, and grants power only when it is available Catalyst 3560 Switch Software Configuration Guide 1-8 78-16156-01 the switch maintains a power budget, monitors and tracks requests for switches not participating in the multicast to be pruned. Includes support for PIM sparse mode... IP address requests, from DHCP clients Power over Ethernet (PoE) Features • Ability to provide power to connected Cisco pre-standard and IEEE 802.3af-compliant powered devices from all 10/100 Ethernet ports if the switch senses that there is no power on the circuit •...
Software Configuration Guide
Page 48
... Chapter 23, "Configuring SPAN and RSPAN" 1-10 Catalyst 3560 Switch Software Configuration Guide 78-16156-01 Default Settings After Initial Switch Configuration Chapter 1 Overview Table 1-1 Default Settings After Initial Switch Configuration (continued) Feature Port parameters Operating mode Interface ...speed and duplex mode Auto-MDIX Flow control Power over Ethernet (PoE) SmartPort macros Default...
... Chapter 23, "Configuring SPAN and RSPAN" 1-10 Catalyst 3560 Switch Software Configuration Guide 78-16156-01 Default Settings After Initial Switch Configuration Chapter 1 Overview Table 1-1 Default Settings After Initial Switch Configuration (continued) Feature Port parameters Operating mode Interface ...speed and duplex mode Auto-MDIX Flow control Power over Ethernet (PoE) SmartPort macros Default...
Software Configuration Guide
Page 51
... multimedia traffic are configured on the switches provide intra-VLAN security and prevent unauthorized users from a home or office to the Internet or an intranet at least two queues per wiring closet. Catalyst PoE switch ports automatically detect any Cisco pre-standard and IEEE 802.3af-...compliant powered devices that support at higher speeds Use the Catalyst Long-Reach Ethernet (LRE) switches to provide up to 500 employees. or low-priority,...
... multimedia traffic are configured on the switches provide intra-VLAN security and prevent unauthorized users from a home or office to the Internet or an intranet at least two queues per wiring closet. Catalyst PoE switch ports automatically detect any Cisco pre-standard and IEEE 802.3af-...compliant powered devices that support at higher speeds Use the Catalyst Long-Reach Ethernet (LRE) switches to provide up to 500 employees. or low-priority,...
Software Configuration Guide
Page 232
...the interface to report that there is connected to a PoE switch port and to power the device. mdix auto Enable Auto-MDIX on an Interface The switch supports both the Cisco pre-standard PoE method and the IEEE 802.3af PoE standard. A powered device can receive redundant power when ...wall power, the switch might continue to an AC power source. If a device being powered by the switch is being powered by the switch or receiving power from an AC power source. 10-16 Catalyst 3560 Switch Software Configuration Guide 78-16156-01 The switch continues to autonegotiate duplex...
...the interface to report that there is connected to a PoE switch port and to power the device. mdix auto Enable Auto-MDIX on an Interface The switch supports both the Cisco pre-standard PoE method and the IEEE 802.3af PoE standard. A powered device can receive redundant power when ...wall power, the switch might continue to an AC power source. If a device being powered by the switch is being powered by the switch or receiving power from an AC power source. 10-16 Catalyst 3560 Switch Software Configuration Guide 78-16156-01 The switch continues to autonegotiate duplex...
Software Configuration Guide
Page 233
...interface on its type or uses an initial allocation of the connected Cisco PoE (standard and pre-standard) devices, and the switch adjusts the power budget accordingly. After power is applied to an interface, the switch uses Cisco Discovery Protocol (CDP) to determine the power requirement of 15.4 W...to the command reference for power budgeting. • If enough power is available, the switch grants power, updates the power budget, turns on page 35-12. 78-16156-01 Catalyst 3560 Switch Software Configuration Guide 10-17 For information about the output of the show power inline [...
...interface on its type or uses an initial allocation of the connected Cisco PoE (standard and pre-standard) devices, and the switch adjusts the power budget accordingly. After power is applied to an interface, the switch uses Cisco Discovery Protocol (CDP) to determine the power requirement of 15.4 W...to the command reference for power budgeting. • If enough power is available, the switch grants power, updates the power budget, turns on page 35-12. 78-16156-01 Catalyst 3560 Switch Software Configuration Guide 10-17 For information about the output of the show power inline [...
Software Configuration Guide
Page 234
...PoE on a port and the response from the show power inline command for the interface when a Cisco IEEE-compliant IP Phone is being supplied with CNTL/Z. show interfaces gigabitethernet0/2 description Interface Status Protocol Description Gi0/2 admin down down Connects to Marketing 10-18 Catalyst 3560 Switch...5 Step 6 Command Purpose configure terminal Enter global configuration mode. This example shows how to add a description on 6.3 Cisco IP Phone 7960 Class 2 Adding a Description for an interface. Beginning in privileged EXEC mode, follow these privileged EXEC ...
...PoE on a port and the response from the show power inline command for the interface when a Cisco IEEE-compliant IP Phone is being supplied with CNTL/Z. show interfaces gigabitethernet0/2 description Interface Status Protocol Description Gi0/2 admin down down Connects to Marketing 10-18 Catalyst 3560 Switch...5 Step 6 Command Purpose configure terminal Enter global configuration mode. This example shows how to add a description on 6.3 Cisco IP Phone 7960 Class 2 Adding a Description for an interface. Beginning in privileged EXEC mode, follow these privileged EXEC ...
Software Configuration Guide
Page 238
... prompt.) These commands are fully described in the Cisco IOS Interface Command Reference for the interface. Display PoE status for a switch or for IP routing or the specified interface. ...by using the show power inline [interface-id] Purpose Display the status and configuration of switching (nonrouting) ports. Display the hardware configuration, software version, the names and sources of interfaces... lists some of these sections to find out if a port is in routing or switching mode. Display the running -config interface [interface-id] show version show controllers ethernet-...
... prompt.) These commands are fully described in the Cisco IOS Interface Command Reference for the interface. Display PoE status for a switch or for IP routing or the specified interface. ...by using the show power inline [interface-id] Purpose Display the status and configuration of switching (nonrouting) ports. Display the hardware configuration, software version, the names and sources of interfaces... lists some of these sections to find out if a port is in routing or switching mode. Display the running -config interface [interface-id] show version show controllers ethernet-...
Software Configuration Guide
Page 297
... configure the port trust state to trust by default globally and on switch access ports; For information about PoE interfaces, see Chapter 28, "Configuring QoS." • You must be in the same VLAN: - The Cisco IP Phone uses untagged frames and the device uses 802.1p frames.... • Before you enable QoS on trunk ports, even though the configuration is the same as the access VLAN. 78-16156-01 Catalyst 3560 Switch Software Configuration Guide 14-3 This section contains this configuration information: • Default Voice VLAN Configuration, page 14-3 • Voice VLAN ...
... configure the port trust state to trust by default globally and on switch access ports; For information about PoE interfaces, see Chapter 28, "Configuring QoS." • You must be in the same VLAN: - The Cisco IP Phone uses untagged frames and the device uses 802.1p frames.... • Before you enable QoS on trunk ports, even though the configuration is the same as the access VLAN. 78-16156-01 Catalyst 3560 Switch Software Configuration Guide 14-3 This section contains this configuration information: • Default Voice VLAN Configuration, page 14-3 • Voice VLAN ...
Software Configuration Guide
Page 459
... during the current session. To clear the contents of the host to be output asynchronously based on the level of Power over Ethernet (PoE) events on these ports is 2048 bytes. • (Optional) For severity-level-number | type, specify either the logging severity level... or the logging type. Logging on specific PoE-capable ports. Synchronizing Log Messages You can also configure the maximum number of syslog servers that are dropped. 78-16156-01 Catalyst 3560 Switch Software Configuration Guide 25-5 To display the messages that receive logging...
... during the current session. To clear the contents of the host to be output asynchronously based on the level of Power over Ethernet (PoE) events on these ports is 2048 bytes. • (Optional) For severity-level-number | type, specify either the logging severity level... or the logging type. Logging on specific PoE-capable ports. Synchronizing Log Messages You can also configure the maximum number of syslog servers that are dropped. 78-16156-01 Catalyst 3560 Switch Software Configuration Guide 25-5 To display the messages that receive logging...
Software Configuration Guide
Page 790
...8226; A manually set speed or duplex parameter is different from the manually set speed or duplex parameter on the two ports to monitor PoE port status: • show controllers power inline privileged EXEC command • show power inline privileged EXEC command • debug ilpower ...EXEC command SFP Module Security and Identification Cisco-approved small form-factor pluggable (SFP) modules have a serial EEPROM that is connected to the SFP modules and module interfaces. There are situations when this release. 35-12 Catalyst 3560 Switch Software Configuration Guide 78-16156-01 When ...
...8226; A manually set speed or duplex parameter is different from the manually set speed or duplex parameter on the two ports to monitor PoE port status: • show controllers power inline privileged EXEC command • show power inline privileged EXEC command • debug ilpower ...EXEC command SFP Module Security and Identification Cisco-approved small form-factor pluggable (SFP) modules have a serial EEPROM that is connected to the SFP modules and module interfaces. There are situations when this release. 35-12 Catalyst 3560 Switch Software Configuration Guide 78-16156-01 When ...
Software Configuration Guide
Page 851
...See MSTP 802.1W See RSTP 802.1X See port-based authentication 802.3AD See EtherChannel 802.3af See PoE 1-8 802.3Z flow control 10-14 A abbreviating commands 2-3 ABRs 30-29 AC (command switch) 5-10, 5-19 access-class command 27-19 access control entries See ACEs access-denied response, VMPS 12... 10-2 in switch clusters 5-9 accounting with RADIUS 8-28 with TACACS+ 8-11, 8-17 ACEs and QoS 28-7 defined 27-2 Ethernet 27-2 IP 27-2 ACLs ACEs 27-2 any keyword 27-12 applying on bridged packets 27-38 on multicast packets 27-39 on routed packets 27-38 Catalyst 3560 Switch Software Configuration Guide...
...See MSTP 802.1W See RSTP 802.1X See port-based authentication 802.3AD See EtherChannel 802.3af See PoE 1-8 802.3Z flow control 10-14 A abbreviating commands 2-3 ABRs 30-29 AC (command switch) 5-10, 5-19 access-class command 27-19 access control entries See ACEs access-denied response, VMPS 12... 10-2 in switch clusters 5-9 accounting with RADIUS 8-28 with TACACS+ 8-11, 8-17 ACEs and QoS 28-7 defined 27-2 Ethernet 27-2 IP 27-2 ACLs ACEs 27-2 any keyword 27-12 applying on bridged packets 27-38 on multicast packets 27-39 on routed packets 27-38 Catalyst 3560 Switch Software Configuration Guide...
Software Configuration Guide
Page 875
... v2 improvements 32-4 78-16156-01 Index PIM-DVMRP, as snooping method 19-8 ping character output description 35-14 executing 35-13 overview 35-13 PoE configuring 10-16 support for 1-8 troubleshooting 35-12 poison-reverse updates, IGRP 30-25 policed-DSCP map for QoS 28-49 policers configuring for each... of 28-42 configuring 28-42 described 28-7 displaying 28-65 port ACLs defined 27-2 types of 27-3 Port Aggregation Protocol See EtherChannel See PAgP Catalyst 3560 Switch Software Configuration Guide IN-25
... v2 improvements 32-4 78-16156-01 Index PIM-DVMRP, as snooping method 19-8 ping character output description 35-14 executing 35-13 overview 35-13 PoE configuring 10-16 support for 1-8 troubleshooting 35-12 poison-reverse updates, IGRP 30-25 policed-DSCP map for QoS 28-49 policers configuring for each... of 28-42 configuring 28-42 described 28-7 displaying 28-65 port ACLs defined 27-2 types of 27-3 Port Aggregation Protocol See EtherChannel See PAgP Catalyst 3560 Switch Software Configuration Guide IN-25
Software Configuration Guide
Page 877
... 20-6 dynamic access 12-4 protected 20-5 routed 10-3 secure 20-7 static-access 12-3, 12-11 switch 10-2 trunks 12-3, 12-16 VLAN assignments 12-11 port security aging 20-14 and QoS trusted boundary...sticky learning 20-8 violations 20-9 with other features 20-10 port-shutdown response, VMPS 12-28 Power over Ethernet See PoE preferential treatment of traffic See QoS prefix lists, BGP 30-54 preventing unauthorized access 8-1 priority HSRP 31-6 overriding CoS 14... guidelines 28-22 described 28-18 disabling 28-23 displaying generated commands 28-23 Catalyst 3560 Switch Software Configuration Guide IN-27
... 20-6 dynamic access 12-4 protected 20-5 routed 10-3 secure 20-7 static-access 12-3, 12-11 switch 10-2 trunks 12-3, 12-16 VLAN assignments 12-11 port security aging 20-14 and QoS trusted boundary...sticky learning 20-8 violations 20-9 with other features 20-10 port-shutdown response, VMPS 12-28 Power over Ethernet See PoE preferential treatment of traffic See QoS prefix lists, BGP 30-54 preventing unauthorized access 8-1 priority HSRP 31-6 overriding CoS 14... guidelines 28-22 described 28-18 disabling 28-23 displaying generated commands 28-23 Catalyst 3560 Switch Software Configuration Guide IN-27