Datasheet RFP 32 IP and RFP 34 IP
Page 1
... handsets act as normal company extensions, which are connected to a company's headquarters via IP routes. RFP (L)32 IP and (L)34 IP DECToverIP / SIP-DECT base stations The Radio Fixed Parts RFP (L)32 IP and RFP (L)34 IP are prelicensed for SIP-DECT systems of up to 20 RFPs, the technical infrastructure is identical. This ensures full compatibility with cordless DECT terminals, which means that are available as system telephones...
... handsets act as normal company extensions, which are connected to a company's headquarters via IP routes. RFP (L)32 IP and (L)34 IP DECToverIP / SIP-DECT base stations The Radio Fixed Parts RFP (L)32 IP and RFP (L)34 IP are prelicensed for SIP-DECT systems of up to 20 RFPs, the technical infrastructure is identical. This ensures full compatibility with cordless DECT terminals, which means that are available as system telephones...
Datasheet RFP 32 IP and RFP 34 IP
Page 2
... Wall- Picture similar to product. Features DECT All 120 (in America 60) DECT channels supported for maximum use of DECT capacity 8 simultaneous voice channels per RFP, 4 additional channels for handover GAP standard supported Connection handover in line with the GAP standard DSAA authentication between base and handset Support of DECT encryption Cordless system telephones can be connected via RJ 45 or IDC (insulation displacement contact) connectors Ethernet Connection via Ethernet 100 BaseT Power...
... Wall- Picture similar to product. Features DECT All 120 (in America 60) DECT channels supported for maximum use of DECT capacity 8 simultaneous voice channels per RFP, 4 additional channels for handover GAP standard supported Connection handover in line with the GAP standard DSAA authentication between base and handset Support of DECT encryption Cordless system telephones can be connected via RJ 45 or IDC (insulation displacement contact) connectors Ethernet Connection via Ethernet 100 BaseT Power...
Datasheet DECT Site Survey Kit (EMEA)
Page 1
... determine the number and locations of the DECT base stations required to enable high-quality measurements with just a single technician. It is required for this purpose. The DECT Site Survey Kit has been developed for locations where several DECT using companies share the same office building. The carry case provides spacing for an optional measuring handset from Kirk...
... determine the number and locations of the DECT base stations required to enable high-quality measurements with just a single technician. It is required for this purpose. The DECT Site Survey Kit has been developed for locations where several DECT using companies share the same office building. The carry case provides spacing for an optional measuring handset from Kirk...
Datasheet DECT Site Survey Kit (EMEA)
Page 2
... case »1 x Test base station with connecting line for the battery pack »2 x Base station battery packs »1 x Battery pack charging unit »2 x Test handset (Aastra) »2 x Charging bay for test handset (Aastra) »1 x Headset for test handset (Aastra) »2 x Belt clip for test handset (Aastra) »1 x Data link cable for test handset (Aastra) »1 x Link cable for Base approx. 3-4 hours station battery pack » Minimum operating time of the approx. 3 hours handsets » Weight (case...
... case »1 x Test base station with connecting line for the battery pack »2 x Base station battery packs »1 x Battery pack charging unit »2 x Test handset (Aastra) »2 x Charging bay for test handset (Aastra) »1 x Headset for test handset (Aastra) »2 x Belt clip for test handset (Aastra) »1 x Data link cable for test handset (Aastra) »1 x Link cable for Base approx. 3-4 hours station battery pack » Minimum operating time of the approx. 3 hours handsets » Weight (case...
User Guide DECT Site Survey Kit (EMEA)
Page 32
... in power supply units) are suitable and approved for future reference. Nonetheless errors cannot be excluded in contacts with the utmost care. Liability for direct or indirect damage that in the Annex. • Do not place the equipment - The product's functions have been produced with sharp and/or metallic objects! • Only use the test kit in areas...
... in power supply units) are suitable and approved for future reference. Nonetheless errors cannot be excluded in contacts with the utmost care. Liability for direct or indirect damage that in the Annex. • Do not place the equipment - The product's functions have been produced with sharp and/or metallic objects! • Only use the test kit in areas...
User Guide DECT Site Survey Kit (EMEA)
Page 33
... DECT base station for outdoor supply ...46 DECT base station for indoor supply ...46 Preparing the Measurements...47 Handover overlap areas-> Base stations synchronisation 47 Traffic density ...48 Hotspots ...49 Conducting the measurement...50 Functional test of the testing equipment 50 Setting up an internal connection between the handsets 50 Activating the test mode on the handset 51 Measuring procedure...52 Using...
... DECT base station for outdoor supply ...46 DECT base station for indoor supply ...46 Preparing the Measurements...47 Handover overlap areas-> Base stations synchronisation 47 Traffic density ...48 Hotspots ...49 Conducting the measurement...50 Functional test of the testing equipment 50 Setting up an internal connection between the handsets 50 Activating the test mode on the handset 51 Measuring procedure...52 Using...
User Guide DECT Site Survey Kit (EMEA)
Page 35
The DECT EMEA Site Survey Kit Content of the Site Survey Kit Designation Number of entries 1 Test base station with connecting line on the battery pack 1 2 Base station battery pack 2 3 Battery pack charging unit 1 4 Test handset (Aastra) 2 5 Charging bay for test handset (Aastra) 2 6 Headset for test handset (Aastra) 1 7 Belt clip for test handset (Aastra) 2 8 Data link cable for test handset (Aastra) 1 9 Link cable for connecting external music source to test handset (Aastra) 1 10 User's Manual 1 Also available as an...
The DECT EMEA Site Survey Kit Content of the Site Survey Kit Designation Number of entries 1 Test base station with connecting line on the battery pack 1 2 Base station battery pack 2 3 Battery pack charging unit 1 4 Test handset (Aastra) 2 5 Charging bay for test handset (Aastra) 2 6 Headset for test handset (Aastra) 1 7 Belt clip for test handset (Aastra) 2 8 Data link cable for test handset (Aastra) 1 9 Link cable for connecting external music source to test handset (Aastra) 1 10 User's Manual 1 Also available as an...
User Guide DECT Site Survey Kit (EMEA)
Page 36
... base stations are used for new projects in particular: • Radio coverage area, capacity in the PBX numbering plan but also of connections ("traffic density") • Known problem areas and what to do about them • Handover behaviour and what happens during a handover • Cordless groups and other features With a project extension a distinction needs to be used . Basics General If a DECT system is to operate faultlessly...
... base stations are used for new projects in particular: • Radio coverage area, capacity in the PBX numbering plan but also of connections ("traffic density") • Known problem areas and what to do about them • Handover behaviour and what happens during a handover • Cordless groups and other features With a project extension a distinction needs to be used . Basics General If a DECT system is to operate faultlessly...
User Guide DECT Site Survey Kit (EMEA)
Page 40
... areas (mirrored), fire protection walls, storage tank installations, refrigerating units, boilers, pipes. • Building structures and installations such as steel-reinforced concrete ceilings and walls, stairways, long corridors, rising mains, cable ducts. • Room furnishings such as lifts, cranes, carriages, escalators, blinds, especially ones that affect mainly the range and quality of the transmission. The receive power of DECT...
... areas (mirrored), fire protection walls, storage tank installations, refrigerating units, boilers, pipes. • Building structures and installations such as steel-reinforced concrete ceilings and walls, stairways, long corridors, rising mains, cable ducts. • Room furnishings such as lifts, cranes, carriages, escalators, blinds, especially ones that affect mainly the range and quality of the transmission. The receive power of DECT...
User Guide DECT Site Survey Kit (EMEA)
Page 41
... instructions can help to determine the range. ing your head or your body. • Avoid making phone calls in unsuitable places, for example in marginal zones is a fundamental challenge of radio technology. Practical measurements are carried out on the premises to achieve optimum results: • You can usually improve the connection quality through minor changes in location, e.g. by turn...
... instructions can help to determine the range. ing your head or your body. • Avoid making phone calls in unsuitable places, for example in marginal zones is a fundamental challenge of radio technology. Practical measurements are carried out on the premises to achieve optimum results: • You can usually improve the connection quality through minor changes in location, e.g. by turn...
User Guide DECT Site Survey Kit (EMEA)
Page 44
... special infrastructure areas such as specifications to be determined on site through concrete floors and ceilings in a vertical direction and in a horizontal direction behind 2 or 3 ordinary brick walls; Roughly determine the locations for the base stations. Ascertaining customer requirements Since the aim of DECT systems is described below. 1. Records avoid misunderstandings and can be of help: • Good connections still...
... special infrastructure areas such as specifications to be determined on site through concrete floors and ceilings in a vertical direction and in a horizontal direction behind 2 or 3 ordinary brick walls; Roughly determine the locations for the base stations. Ascertaining customer requirements Since the aim of DECT systems is described below. 1. Records avoid misunderstandings and can be of help: • Good connections still...
User Guide DECT Site Survey Kit (EMEA)
Page 46
Record the values measured as well as the supply range on the ground plan, horizontal and vertical. • The measurements provide a reliable idea of the equipment required and the locations for the base stations. • Co-operation with the plan using on-site measurements. for more...rooms, the ideal installation height increases accordingly) while maintaining a minimum distance of base stations, provided this considerably impairs the radio hop and results in keeping with the customer: As soon as you are able to make sufficiently binding statements about "problem areas", you should ...
Record the values measured as well as the supply range on the ground plan, horizontal and vertical. • The measurements provide a reliable idea of the equipment required and the locations for the base stations. • Co-operation with the plan using on-site measurements. for more...rooms, the ideal installation height increases accordingly) while maintaining a minimum distance of base stations, provided this considerably impairs the radio hop and results in keeping with the customer: As soon as you are able to make sufficiently binding statements about "problem areas", you should ...
User Guide DECT Site Survey Kit (EMEA)
Page 48
...permanently. • Base stations and handsets generate pulsed RF signals. Note Take note of an external antenna, too. DECT base station for outdoor supply The following principles are to be observed when installing DECT base stations outdoors: ...check the use of safety distances and safety regulations. Maintain a distance of > 50 cm! • Connecting line between PBX and DECT base station: Crosstalk can affect sensitive electronic equipment (control systems, measuring sensors, sensors, diagnostics equipment on inner walls rather than outdoor walls. • Ceiling mounting...
...permanently. • Base stations and handsets generate pulsed RF signals. Note Take note of an external antenna, too. DECT base station for outdoor supply The following principles are to be observed when installing DECT base stations outdoors: ...check the use of safety distances and safety regulations. Maintain a distance of > 50 cm! • Connecting line between PBX and DECT base station: Crosstalk can affect sensitive electronic equipment (control systems, measuring sensors, sensors, diagnostics equipment on inner walls rather than outdoor walls. • Ceiling mounting...
User Guide DECT Site Survey Kit (EMEA)
Page 49
...; To guarantee synchronisation, you need to achieve an overlap with other base station within the -70 dBm limit! Radio coverage and area determination • Make a note of the connection capacity required (number of simultaneous calls) for each area to determine the number of the planned supply range is satisfactorily covered. Measurement/Planning Preparing the Measurements Drawing up for each...
...; To guarantee synchronisation, you need to achieve an overlap with other base station within the -70 dBm limit! Radio coverage and area determination • Make a note of the connection capacity required (number of simultaneous calls) for each area to determine the number of the planned supply range is satisfactorily covered. Measurement/Planning Preparing the Measurements Drawing up for each...
User Guide DECT Site Survey Kit (EMEA)
Page 51
... out across 120 radio channels. Thus approx. 60 handsets can help attenuate the strong signals which require for example four base stations. It is an area with several base stations as the resources in "ZeroBlind-Slot mode" and the calls can be used simultaneously. Also check the possibility of a spherical arrangement of handsets. Measurement/Planning Hotspots A hotspot is essential to...
... out across 120 radio channels. Thus approx. 60 handsets can help attenuate the strong signals which require for example four base stations. It is an area with several base stations as the resources in "ZeroBlind-Slot mode" and the calls can be used simultaneously. Also check the possibility of a spherical arrangement of handsets. Measurement/Planning Hotspots A hotspot is essential to...
User Guide DECT Site Survey Kit (EMEA)
Page 52
... time, and also allows the personnel involved in the measurement to maintain a continuous call connection from, key in test mode. Next connect the base station with one of the handsets using the "test mobile - Measurement/Planning Conducting the measurement Functional test of the testing equipment Remove the charging bays for the battery packs from the kit and the charging unit for operating the base...
... time, and also allows the personnel involved in the measurement to maintain a continuous call connection from, key in test mode. Next connect the base station with one of the handsets using the "test mobile - Measurement/Planning Conducting the measurement Functional test of the testing equipment Remove the charging bays for the battery packs from the kit and the charging unit for operating the base...
User Guide DECT Site Survey Kit (EMEA)
Page 53
... changed. The display indicates the user (here: DeTeWe) and the handset's internal call number (here: 1) Both the user name and the internal call , press the handset key a second time. FE PP/FP: Errors occurred on the handset The handset is now in addition to four base stations of the receive signal (RSSI) - FP: ... -dBm ...... RPN ...... RFPI: worldwide unique code of the base station with suffi- RPN ...... In Site Survey Mode...
... changed. The display indicates the user (here: DeTeWe) and the handset's internal call number (here: 1) Both the user name and the internal call , press the handset key a second time. FE PP/FP: Errors occurred on the handset The handset is now in addition to four base stations of the receive signal (RSSI) - FP: ... -dBm ...... RPN ...... RFPI: worldwide unique code of the base station with suffi- RPN ...... In Site Survey Mode...
User Guide DECT Site Survey Kit (EMEA)
Page 57
Switching between the existing RFPI To end the diagnostic mode, press the menu key [MENU]. Measurement/Planning Using the optional Kirk test handset The Kirk test handset is used to determine existing/other DECT systems that could influence the existing DECT system or any new DECT system to the relevant operating instructions. 55 Current base / total number of the current base - xx xx xx xx xx/xx xx...
Switching between the existing RFPI To end the diagnostic mode, press the menu key [MENU]. Measurement/Planning Using the optional Kirk test handset The Kirk test handset is used to determine existing/other DECT systems that could influence the existing DECT system or any new DECT system to the relevant operating instructions. 55 Current base / total number of the current base - xx xx xx xx xx/xx xx...
User Guide DECT Site Survey Kit (EMEA)
Page 58
... not take the batteries apart. This can be considerably extended by switching off the display and keypad lighting) Important information on using batteries 1. Annex Technical data Frequency band Number of carrier frequencies Maximum transmitting power Access facilities Duplex method Number of time slots Number of duplex channels Gross data rate Net data rate Operating/charging time for Base station battery pack Minimum operating time of the handsets 1880 - 1900...
... not take the batteries apart. This can be considerably extended by switching off the display and keypad lighting) Important information on using batteries 1. Annex Technical data Frequency band Number of carrier frequencies Maximum transmitting power Access facilities Duplex method Number of time slots Number of duplex channels Gross data rate Net data rate Operating/charging time for Base station battery pack Minimum operating time of the handsets 1880 - 1900...
User Guide DECT Site Survey Kit (EMEA)
Page 59
... and in the charging station at any time. When new batteries are required before it can place your handset back in the optimum way whatever the charging state. Several charging/discharging cycles are inserted, the battery display requires a few charging cycles before new batteries reach their constituent substances, e.g.: 57 Avoid removing the batteries from the handset for no particular reason as they...
... and in the charging station at any time. When new batteries are required before it can place your handset back in the optimum way whatever the charging state. Several charging/discharging cycles are inserted, the battery display requires a few charging cycles before new batteries reach their constituent substances, e.g.: 57 Avoid removing the batteries from the handset for no particular reason as they...