Use and Care Guide
Page 4
...; Caulking gun and compound (for installing new exhaust ■ Wire stripper (direct wire vent) installations) ■ Tape measure Parts supplied: Remove parts package from dryer drum. INSTALLATION INSTRUCTIONS Tools and Parts Gather the required tools and parts before starting installation. Short inlet hose D. "Y" connector C. Rubber washer 4 Read and follow the instructions provided with any tools...
...; Caulking gun and compound (for installing new exhaust ■ Wire stripper (direct wire vent) installations) ■ Tape measure Parts supplied: Remove parts package from dryer drum. INSTALLATION INSTRUCTIONS Tools and Parts Gather the required tools and parts before starting installation. Short inlet hose D. "Y" connector C. Rubber washer 4 Read and follow the instructions provided with any tools...
Use and Care Guide
Page 5
...marked for use the water supply for your local building inspector. Location Requirements You will be considered. ■ Cold water faucets located within 2 ft (610 mm) of either the right or left side. 18"* (457 mm) 14" máx.* (356 mm) 48 in.2* (310...see "Electrical Requirements" and "Venting Requirements" before purchasing parts. Parts needed ) which are recommended for this dryer. This dryer has been tested for spacing of the dryer to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for mobile home installations...
...marked for use the water supply for your local building inspector. Location Requirements You will be considered. ■ Cold water faucets located within 2 ft (610 mm) of either the right or left side. 18"* (457 mm) 14" máx.* (356 mm) 48 in.2* (310...see "Electrical Requirements" and "Venting Requirements" before purchasing parts. Parts needed ) which are recommended for this dryer. This dryer has been tested for spacing of the dryer to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for mobile home installations...
Use and Care Guide
Page 7
... CSA International Certified Power Cord intended to do so can result in length. GROUNDING INSTRUCTIONS ■ For a grounded, cord-connected dryer: This dryer must be plugged into a standard 14-30R wall receptacle. In the event of malfunction or breakdown, grounding will not fit the outlet..., have a proper outlet installed by providing a path of dryer's final location. ■ Do not use Power Supply Cord Replacement Part Number 3394208. This dryer is 5 ft (1.52 m) in a risk of the line. Failure to be plugged into a grounded 4 prong...
... CSA International Certified Power Cord intended to do so can result in length. GROUNDING INSTRUCTIONS ■ For a grounded, cord-connected dryer: This dryer must be plugged into a standard 14-30R wall receptacle. In the event of malfunction or breakdown, grounding will not fit the outlet..., have a proper outlet installed by providing a path of dryer's final location. ■ Do not use Power Supply Cord Replacement Part Number 3394208. This dryer is 5 ft (1.52 m) in a risk of the line. Failure to be plugged into a grounded 4 prong...
Use and Care Guide
Page 13
... and insects from entering the home. ■ Exhaust hood must be at least 12" (305 mm) from your dealer or by calling Whirlpool Parts and Accessories. Venting Requirements WARNING ■ Remove excess flexible metal vent to avoid sagging and kinking that may be used. WARNING: To reduce...make sure exhaust hood is in enclosed walls, ceilings, or floors. ■ The total length of flexible metal duct shall not exceed 7 3/4 ft (2.4 m). The dryer exhaust must be in death or fire. Flexible metal vent ■ Flexible metal vents are recommended. 4" (102 mm) heavy metal exhaust vent ...
... and insects from entering the home. ■ Exhaust hood must be at least 12" (305 mm) from your dealer or by calling Whirlpool Parts and Accessories. Venting Requirements WARNING ■ Remove excess flexible metal vent to avoid sagging and kinking that may be used. WARNING: To reduce...make sure exhaust hood is in enclosed walls, ceilings, or floors. ■ The total length of flexible metal duct shall not exceed 7 3/4 ft (2.4 m). The dryer exhaust must be in death or fire. Flexible metal vent ■ Flexible metal vents are recommended. 4" (102 mm) heavy metal exhaust vent ...
Use and Care Guide
Page 14
...latch. Please see the "Assistance or Service" section to left or right side: Part Number 49611 Special provisions for your exhaust installation type Recommended exhaust installations Typical installations vent the dryer from the rear of the mobile home structure and must not terminate beneath the ... are shown. Exhaust hood H E. Exhaust outlet Standard exhaust installation with dryer vent to wall vent mismatch): Part Number 4396037 - 0" (0 mm) to 18" (457 mm) mismatch Part Number 4396011 - 18" (457 mm) to 29" (737 mm) mismatch Part Number 4396014 - 29" (737 mm) to 50" (127 mm)...
...latch. Please see the "Assistance or Service" section to left or right side: Part Number 49611 Special provisions for your exhaust installation type Recommended exhaust installations Typical installations vent the dryer from the rear of the mobile home structure and must not terminate beneath the ... are shown. Exhaust hood H E. Exhaust outlet Standard exhaust installation with dryer vent to wall vent mismatch): Part Number 4396037 - 0" (0 mm) to 18" (457 mm) mismatch Part Number 4396011 - 18" (457 mm) to 29" (737 mm) mismatch Part Number 4396014 - 29" (737 mm) to 50" (127 mm)...
Use and Care Guide
Page 18
...all packaging materials. 4. For direct wire installation, turn on power. 9. See "Level Dryer." 8. If you have a film on . 5. NOTE: You may clog different parts of a water softener is level. This dryer automatically runs an installation diagnostic routine at the start , check the following: ■...Troubleshooting." This odor is common when the heating element is an extra part, go away. 18 Check that you live in the dryer. Dispose of/recycle all parts are on the window that the dryer is recommended to see which will reduce product performance. Turn on ...
...all packaging materials. 4. For direct wire installation, turn on power. 9. See "Level Dryer." 8. If you have a film on . 5. NOTE: You may clog different parts of a water softener is level. This dryer automatically runs an installation diagnostic routine at the start , check the following: ■...Troubleshooting." This odor is common when the heating element is an extra part, go away. 18 Check that you live in the dryer. Dispose of/recycle all parts are on the window that the dryer is recommended to see which will reduce product performance. Turn on ...
Use and Care Guide
Page 21
... selected. See the following Automatic Preset Cycle Settings chart. Casual Use this option is selected. The dryer will continue to the load you choose an Automatic Cycle. See the Automatic, Steam, or Timed Preset Cycle Settings Charts. Each cycle dries certain fabrics at the beginning of load you...of a Timed Cycle, press the Time Adjust up or down part of time selected, and the Wet light will not illuminate. ■ In the Enhanced Touch Up or the Quick Refresh Steam Cycles, the Wet light comes on your dryer with 1 minute of your load, by pressing Temp until the...
... selected. See the following Automatic Preset Cycle Settings chart. Casual Use this option is selected. The dryer will continue to the load you choose an Automatic Cycle. See the Automatic, Steam, or Timed Preset Cycle Settings Charts. Each cycle dries certain fabrics at the beginning of load you...of a Timed Cycle, press the Time Adjust up or down part of time selected, and the Wet light will not illuminate. ■ In the Enhanced Touch Up or the Quick Refresh Steam Cycles, the Wet light comes on your dryer with 1 minute of your load, by pressing Temp until the...
Use and Care Guide
Page 26
... Locate the light bulb cover on inside the dryer drum when you may not have not tripped. Replace all parts and panels before servicing. Transport hose separately. 3. Replace the cover and secure with a 10-watt appliance bulb only. www.whirlpool.com/help - There may be a thumping ... wiring. 3. Shut off water faucet. 3. Disconnect the water inlet hose from faucet, then drain the hose. In U.S.A. In Canada www.whirlpool.ca Dryer Operation Dryer will not run ■ Has a household fuse blown, or has a circuit breaker tripped? Check that both fuses are intact and tight,...
... Locate the light bulb cover on inside the dryer drum when you may not have not tripped. Replace all parts and panels before servicing. Transport hose separately. 3. Replace the cover and secure with a 10-watt appliance bulb only. www.whirlpool.com/help - There may be a thumping ... wiring. 3. Shut off water faucet. 3. Disconnect the water inlet hose from faucet, then drain the hose. In U.S.A. In Canada www.whirlpool.ca Dryer Operation Dryer will not run ■ Has a household fuse blown, or has a circuit breaker tripped? Check that both fuses are intact and tight,...
Use and Care Guide
Page 29
... . Part Number Accessory 20-48KITRC 4 ft (1.2 m) gas line dryer connector installation kit PT220L 4 ft (1.2 m) dryer cord, 3-wire, 30 amp PT400L 4 ft (1.2 m) dryer cord, 4-wire, 30 amp PT600L 6 ft (1.8 m) dryer cord, 4-wire, 30 amp 8212614 Dryer vent lint brush 31682 All-purpose appliance cleaner 1903WH Laundry supply storage cart 49572 LP Gas conversion kit W10071550A Drying rack W10044609A Steam hose kit Accessories U.S.A. Whirlpool...
... . Part Number Accessory 20-48KITRC 4 ft (1.2 m) gas line dryer connector installation kit PT220L 4 ft (1.2 m) dryer cord, 3-wire, 30 amp PT400L 4 ft (1.2 m) dryer cord, 4-wire, 30 amp PT600L 6 ft (1.8 m) dryer cord, 4-wire, 30 amp 8212614 Dryer vent lint brush 31682 All-purpose appliance cleaner 1903WH Laundry supply storage cart 49572 LP Gas conversion kit W10071550A Drying rack W10044609A Steam hose kit Accessories U.S.A. Whirlpool...