English Owners Manual
Page 10
... police frequencies into this bank. » FIRE/EMG: 280 Factory-programmed Fire/EMG frequencies plus an additional 100 (shared with 10 FEATURE SUMMARY The BC355C is a compact mobile/base scanner and one standard, programmable Private bank. Allows your BC355C to search 180 steps per second. (5 kHz step band only) • Seven Banks - 6 preprogrammed Service...
... police frequencies into this bank. » FIRE/EMG: 280 Factory-programmed Fire/EMG frequencies plus an additional 100 (shared with 10 FEATURE SUMMARY The BC355C is a compact mobile/base scanner and one standard, programmable Private bank. Allows your BC355C to search 180 steps per second. (5 kHz step band only) • Seven Banks - 6 preprogrammed Service...
English Owners Manual
Page 38
...of Lock Out Temporary Lock Out Pressing L/O once temporarily locks out the current frequency or channel. Types of noise or other unwanted transmissions. The scanner displays "T L/O" for that frequency or channel and continues scanning. This feature lets you lock out channels and frequencies you don't want to scan.... The Lock Out feature skips these channels and frequencies during scanning. • Private Bank • Program Frequencies into Programmable Banks. • Program Lock Lock Out Channels / Frequencies Sometimes the scanner may stop on . 38
...of Lock Out Temporary Lock Out Pressing L/O once temporarily locks out the current frequency or channel. Types of noise or other unwanted transmissions. The scanner displays "T L/O" for that frequency or channel and continues scanning. This feature lets you lock out channels and frequencies you don't want to scan.... The Lock Out feature skips these channels and frequencies during scanning. • Private Bank • Program Frequencies into Programmable Banks. • Program Lock Lock Out Channels / Frequencies Sometimes the scanner may stop on . 38
English Owners Manual
Page 39
If you have saved it out in a channel. If you lock out the 101st frequency. Lock Out Limits Any of the 300 user-programmed channels can be locked out; Locking out a frequency in any service bank or search band locks it in all service banks or search bands. "L/O" ...band search. Up to 100 frequencies can be temporarily locked out. Permanent Lock Out Pressing L/O twice permanently locks out the current frequency or channel. The scanner displays "L/O" for that can only lock out all the channels or frequencies 39 however, there is provides in the Private, CB, and MRN banks. You...
If you have saved it out in a channel. If you lock out the 101st frequency. Lock Out Limits Any of the 300 user-programmed channels can be locked out; Locking out a frequency in any service bank or search band locks it in all service banks or search bands. "L/O" ...band search. Up to 100 frequencies can be temporarily locked out. Permanent Lock Out Pressing L/O twice permanently locks out the current frequency or channel. The scanner displays "L/O" for that can only lock out all the channels or frequencies 39 however, there is provides in the Private, CB, and MRN banks. You...
English Owners Manual
Page 51
NOTE: The CB and WX banks are not programmable. Weather frequencies broadcast continuously, and the scanner will not change to 100 frequencies (1 frequency per channel) can be programmed into each of the following banks (300 frequencies combined): • Police/Fire/EMG • Air/Marine •..., websites such as www. radioreference.com provide listings of these banks can be programmed into either of local broadcast frequencies. ERROR displays if you try to program a frequency into the scanner, and frequencies not currently displayed can be located through the Search mode and through...
NOTE: The CB and WX banks are not programmable. Weather frequencies broadcast continuously, and the scanner will not change to 100 frequencies (1 frequency per channel) can be programmed into each of the following banks (300 frequencies combined): • Police/Fire/EMG • Air/Marine •..., websites such as www. radioreference.com provide listings of these banks can be programmed into either of local broadcast frequencies. ERROR displays if you try to program a frequency into the scanner, and frequencies not currently displayed can be located through the Search mode and through...
English Owners Manual
Page 54
... seconds. 54 The scanner programs the frequency into the indicated channel and then goes into SCAN HOLD mode. CH HOLD 40.0600 From a normal scan setting (a channel bank is to release the Hold and continue scanning the rest of deleting a frequency you just programmed. Press HOLD to ...overwrite it with the channel you have programmed is flashing), press PROG. Press and hold sCAN Press PROG. HOLD displays and CH displays and flashes....
... seconds. 54 The scanner programs the frequency into the indicated channel and then goes into SCAN HOLD mode. CH HOLD 40.0600 From a normal scan setting (a channel bank is to release the Hold and continue scanning the rest of deleting a frequency you just programmed. Press HOLD to ...overwrite it with the channel you have programmed is flashing), press PROG. Press and hold sCAN Press PROG. HOLD displays and CH displays and flashes....
English Owners Manual
Page 57
... hold the PROG key for longer than 2.5 seconds to the previous mode. 57 When Program Lock is turned on, the scanner displays "on Prg‐ Loc" and then returns to the previous mode. Program Lock Feature The BC355C has a Program Lock feature to program on a bank with Program Lock activated will display "Prg‐Loc" as a reminder.
... hold the PROG key for longer than 2.5 seconds to the previous mode. 57 When Program Lock is turned on, the scanner displays "on Prg‐ Loc" and then returns to the previous mode. Program Lock Feature The BC355C has a Program Lock feature to program on a bank with Program Lock activated will display "Prg‐Loc" as a reminder.