ER-A410 | ER-A420 Operation Manual
Page 5
... function 61 TIME DISPLAY AND AUTOMATIC UPDATING OF THE DATE 62 1 Time display 62 2 Automatic updating of the date 62 FOR THE MANAGER PRIOR TO PROGRAMMING 63 1 Programming keyboard layout 63 3
... function 61 TIME DISPLAY AND AUTOMATIC UPDATING OF THE DATE 62 1 Time display 62 2 Automatic updating of the date 62 FOR THE MANAGER PRIOR TO PROGRAMMING 63 1 Programming keyboard layout 63 3
ER-A410 | ER-A420 Operation Manual
Page 6
...2611 81 2 Setting the register and consecutive numbers 82 Setting the register number (#2612 82 Setting the consecutive number (#2613 82 3 Programming for the automatic tax calculation function 83 The tax table (#2710 83 The tax rate (#2711 85 Doughnut tax exempt (for the ...Canadian tax system) (#2715 86 4 Programming for departments 87 Functional programming 1 (#2110 87 Functional programming 2 (#2111 89 A limit amount (HALO) of entry (#2112 90 Alphanumeric characters (#2114 90 Unit price (#1110 91 ...
...2611 81 2 Setting the register and consecutive numbers 82 Setting the register number (#2612 82 Setting the consecutive number (#2613 82 3 Programming for the automatic tax calculation function 83 The tax table (#2710 83 The tax rate (#2711 85 Doughnut tax exempt (for the ...Canadian tax system) (#2715 86 4 Programming for departments 87 Functional programming 1 (#2110 87 Functional programming 2 (#2111 89 A limit amount (HALO) of entry (#2112 90 Alphanumeric characters (#2114 90 Unit price (#1110 91 ...
ER-A410 | ER-A420 Operation Manual
Page 7
... parameter of the slip printer (#2615 128 Setting the time limit for THE TILL TIMERTM (#2617 128 Scale tare table (#2618 129 Programming of logo messages (#2614 130 Selection of X1/Z1 and X2/Z2 reports to PLU/UPC assignment (#2218 105 Delete period for non-...cash in the stacked report sequence (#2620 131 Setting the time range for hourly reports (#2619 132 Programming of power saving mode (#2689 132 PBLU code programming (#2810 133 Functional programming for the printer (#2990 133 Programming of unit price entry, delete method, tare table no. Base quantity (#1211 96 Type of ...
... parameter of the slip printer (#2615 128 Setting the time limit for THE TILL TIMERTM (#2617 128 Scale tare table (#2618 129 Programming of logo messages (#2614 130 Selection of X1/Z1 and X2/Z2 reports to PLU/UPC assignment (#2218 105 Delete period for non-...cash in the stacked report sequence (#2620 131 Setting the time range for hourly reports (#2619 132 Programming of power saving mode (#2689 132 PBLU code programming (#2810 133 Functional programming for the printer (#2990 133 Programming of unit price entry, delete method, tare table no. Base quantity (#1211 96 Type of ...
ER-A410 | ER-A420 Operation Manual
Page 8
...-232C interface (#6110, 6111, 6112, 6113, 6115, 6220 141 Programming the CAT interface (#7110, 7111, 7112, 7113, 7114, 7115 142 Secret codes to control access to the PGM1 mode, X1/Z1 mode and X2/Z2 ...mode (#2630, 2631, 2632 143 Setting the AUTO key (#2900 144 11 TRAINING mode 145 12 Reading stored programs 146 Program details and procedures for their reading 146 Sample printouts 148 13 Universal Product Code (UPC) or European Article Number (EAN 155 UPC or EAN code...
...-232C interface (#6110, 6111, 6112, 6113, 6115, 6220 141 Programming the CAT interface (#7110, 7111, 7112, 7113, 7114, 7115 142 Secret codes to control access to the PGM1 mode, X1/Z1 mode and X2/Z2 ...mode (#2630, 2631, 2632 143 Setting the AUTO key (#2900 144 11 TRAINING mode 145 12 Reading stored programs 146 Program details and procedures for their reading 146 Sample printouts 148 13 Universal Product Code (UPC) or European Article Number (EAN 155 UPC or EAN code...
ER-A410 | ER-A420 Operation Manual
Page 17
...permitted to toggle receipt state "ON" and q "OFF" by pressing the key. (This setting may be used for their sales information. PGM2: To program all register operation. MGR: For manager's and submanager's entries The manager can use this mode to be changed often: e.g., unit prices of the three ...MA) • Submanager key (SM) SM MA OP • Operator key (OP) The mode switch has these settings: OFF: This mode locks all PGM1 programs and those items that need to make entries that do not require frequent changes: e.g., date, time, or a variety of totals. 2 Drawer lock key This...
...permitted to toggle receipt state "ON" and q "OFF" by pressing the key. (This setting may be used for their sales information. PGM2: To program all register operation. MGR: For manager's and submanager's entries The manager can use this mode to be changed often: e.g., unit prices of the three ...MA) • Submanager key (SM) SM MA OP • Operator key (OP) The mode switch has these settings: OFF: This mode locks all PGM1 programs and those items that need to make entries that do not require frequent changes: e.g., date, time, or a variety of totals. 2 Drawer lock key This...
ER-A410 | ER-A420 Operation Manual
Page 18
... assigned by the following procedure, the register prints the four-digit cashier code (variant 2: " ") and the cashier name both on how the register has been programmed. For the selection of the receipt status. This key toggles the receipt printing status ON and OFF.
... assigned by the following procedure, the register prints the four-digit cashier code (variant 2: " ") and the cashier name both on how the register has been programmed. For the selection of the receipt status. This key toggles the receipt printing status ON and OFF.
ER-A410 | ER-A420 Operation Manual
Page 20
... and check the following procedure, the register prints the four-digit cashier code (variant 2: " ") and the cashier name both on how the register has been programmed. Cashier codes are available in two variants: Variant 1, in which they are displayed ("0000" to the OP X/Z position or press the key in the OFF...
... and check the following procedure, the register prints the four-digit cashier code (variant 2: " ") and the cashier name both on how the register has been programmed. Cashier codes are available in two variants: Variant 1, in which they are displayed ("0000" to the OP X/Z position or press the key in the OFF...
ER-A410 | ER-A420 Operation Manual
Page 21
... correct. For the selection of the "Variant 2", consult your dealer. • The cashier can be possible to make an entry beyond a programmed amount entry limit: Check to enter a cashier code before every transaction, please consult your dealer. • For the display type selection of...a mode is changed during a transaction. Contact your register will go into the power saving mode when no entries are performed based on the pre-programmed time limit (by default, 30 minutes). If it is correct, it be changed with a warning beep and a c corresponding error message. Procedure...
... correct. For the selection of the "Variant 2", consult your dealer. • The cashier can be possible to make an entry beyond a programmed amount entry limit: Check to enter a cashier code before every transaction, please consult your dealer. • For the display type selection of...a mode is changed during a transaction. Contact your register will go into the power saving mode when no entries are performed based on the pre-programmed time limit (by default, 30 minutes). If it is correct, it be changed with a warning beep and a c corresponding error message. Procedure...
ER-A410 | ER-A420 Operation Manual
Page 22
...224; or å When [preset only dept.] is added. Department entries (indirect department entries) When using a programmed unit price Unit price * (for which the unit price has been programmed as zero (0) are entered, only the sales quantity is added. Subdepartment (open PLU, open and preset PLU) entries... PLU code When using a programmed unit price PLU/ UPC Unit price * PLU/ UPC (max. 7 digits) å or *Less than the programmed upper limit amounts PLU entries (indirect PLU entries) Enter a PLU code and press the...
...224; or å When [preset only dept.] is added. Department entries (indirect department entries) When using a programmed unit price Unit price * (for which the unit price has been programmed as zero (0) are entered, only the sales quantity is added. Subdepartment (open PLU, open and preset PLU) entries... PLU code When using a programmed unit price PLU/ UPC Unit price * PLU/ UPC (max. 7 digits) å or *Less than the programmed upper limit amounts PLU entries (indirect PLU entries) Enter a PLU code and press the...
ER-A410 | ER-A420 Operation Manual
Page 24
... price @ Unit price Department key Dept. with the key. • Q'ty: Up to four digits integer + three digits decimal • Unit price: Less than a programmed upper limit • Q'ty × unit price: Up to enter quantities that are fractional. 22 entry (indirect) PLU code PLU code When [preset only dept.] ...
... price @ Unit price Department key Dept. with the key. • Q'ty: Up to four digits integer + three digits decimal • Unit price: Less than a programmed upper limit • Q'ty × unit price: Up to enter quantities that are fractional. 22 entry (indirect) PLU code PLU code When [preset only dept.] ...
ER-A410 | ER-A420 Operation Manual
Page 25
... does not exist in the file, the display will å à show "NO RECORD". entry (direct) Dept. Enter the unit price using a programmed unit price @ Unit price Department key Dept. entry (indirect) When [preset only dept.] is entered. with the key. • Length or width: Up... to seven digits (4-digit integer + 3-digit decimal) • Unit price: Less than a programmed upper limit • Length × Width × Unit price: Up to seven digits Note • For actual use a decimal point ( ) key when entering...
... does not exist in the file, the display will å à show "NO RECORD". entry (direct) Dept. Enter the unit price using a programmed unit price @ Unit price Department key Dept. entry (indirect) When [preset only dept.] is entered. with the key. • Length or width: Up... to seven digits (4-digit integer + 3-digit decimal) • Unit price: Less than a programmed upper limit • Length × Width × Unit price: Up to seven digits Note • For actual use a decimal point ( ) key when entering...
ER-A410 | ER-A420 Operation Manual
Page 26
Note You must use a base q'ty programmed for PLU code PLU code PLU code Unit price per base q'ty UPC code PLU code PLU code When [preset only dept.] is entered. PLU/ ... price à or å Only when you use the decimal point ( ) key when entering selling quantities that are fractional. 24 Enter the unit price using a programmed unit price @ Unit price per base q'ty UPC code Direct PLU key Ä PLU/ UPC • After scanning a UPC code or pressing the PLU/ UPC...
Note You must use a base q'ty programmed for PLU code PLU code PLU code Unit price per base q'ty UPC code PLU code PLU code When [preset only dept.] is entered. PLU/ ... price à or å Only when you use the decimal point ( ) key when entering selling quantities that are fractional. 24 Enter the unit price using a programmed unit price @ Unit price per base q'ty UPC code Direct PLU key Ä PLU/ UPC • After scanning a UPC code or pressing the PLU/ UPC...
ER-A410 | ER-A420 Operation Manual
Page 28
... + decimal) • Net weight: Up to 5 digits (integer + decimal) • Base weight: Up to 2 digits (integer) Note • The register can be programmed with up to nine tare tables and allows different tares to be connected where by the weight is automatically read from the scale. Dept. code... 200 1 S P 1 PLU/ UPC c Print 26 code à Unit price à or å When [preset only dept.] is 1 LB (or 1 KG) When using a programmed unit price Unit price per base wt. S • When the key is pressed, the weight is not necessary to them. Scale entries For making entries...
... + decimal) • Net weight: Up to 5 digits (integer + decimal) • Base weight: Up to 2 digits (integer) Note • The register can be programmed with up to nine tare tables and allows different tares to be connected where by the weight is automatically read from the scale. Dept. code... 200 1 S P 1 PLU/ UPC c Print 26 code à Unit price à or å When [preset only dept.] is 1 LB (or 1 KG) When using a programmed unit price Unit price per base wt. S • When the key is pressed, the weight is not necessary to them. Scale entries For making entries...
ER-A410 | ER-A420 Operation Manual
Page 29
Department Dept. When [preset only dept.] is entered. PLU/ UPC PLU/ UPC Unit price per base wt. programmed for PLU code Unit price per base wt. å PLU/ UPC or Only when you use a base wt. is from the customer's receipt. • Base ... base wt. UPC code Direct PLU key Ä PLU/ UPC • Net weight: Up to 5 digits (integer + decimal) which is 1 LB (or 1 KG) When using a programmed unit price Unit price per base wt.
Department Dept. When [preset only dept.] is entered. PLU/ UPC PLU/ UPC Unit price per base wt. programmed for PLU code Unit price per base wt. å PLU/ UPC or Only when you use a base wt. is from the customer's receipt. • Base ... base wt. UPC code Direct PLU key Ä PLU/ UPC • Net weight: Up to 5 digits (integer + decimal) which is 1 LB (or 1 KG) When using a programmed unit price Unit price per base wt.
ER-A410 | ER-A420 Operation Manual
Page 30
You must program your register without adding additional direct PLU keys. Procedure • each item ¬ Ò • each time you finalize one of PLUs on the keyboard, ...
You must program your register without adding additional direct PLU keys. Procedure • each item ¬ Ò • each time you finalize one of PLUs on the keyboard, ...
ER-A410 | ER-A420 Operation Manual
Page 31
Example Direct PLU1: PLU code 1 (PLU level 1), PLU code 65 (PLU level 2) Direct PLU2: PLU code 2 (PLU level 1), PLU code 66 (PLU level 2) • When your machine has been programmed for the automatic return mode: Key operation Print 1 ¬1 2 1 a • When your machine has been programmed for the lock shift mode: Key operation l1 ¬1 2 1 a Print 29
Example Direct PLU1: PLU code 1 (PLU level 1), PLU code 65 (PLU level 2) Direct PLU2: PLU code 2 (PLU level 1), PLU code 66 (PLU level 2) • When your machine has been programmed for the automatic return mode: Key operation Print 1 ¬1 2 1 a • When your machine has been programmed for the lock shift mode: Key operation l1 ¬1 2 1 a Print 29
ER-A410 | ER-A420 Operation Manual
Page 32
... time you finalize one transaction. ** The lock shift mode holds the current PLU/UPC price level until pressing the price level shift key. You must program a price level shift mode (i.e. PLU/UPC price level shift Two different price levels can be used for the price level shift (i.e. both REG/MGR modes... code Direct PLU Ä PLU/UPC code Direct PLU PLU/ UPC PLU/ UPC Payment Lock shift mode (for price level) If your register has been programmed for each PLU or UPC. Procedure To shift the price level of the price level text (LEVEL 1/LEVEL 2)". Please refer to level 1 after a PLU/...
... time you finalize one transaction. ** The lock shift mode holds the current PLU/UPC price level until pressing the price level shift key. You must program a price level shift mode (i.e. PLU/UPC price level shift Two different price levels can be used for the price level shift (i.e. both REG/MGR modes... code Direct PLU Ä PLU/UPC code Direct PLU PLU/ UPC PLU/ UPC Payment Lock shift mode (for price level) If your register has been programmed for each PLU or UPC. Procedure To shift the price level of the price level text (LEVEL 1/LEVEL 2)". Please refer to level 1 after a PLU/...
ER-A410 | ER-A420 Operation Manual
Page 33
... PLU price level 1: PLU 1 ($1.91), PLU 2 ($0.79) PLU price level 2: PLU 1 ($2.00), PLU 2 ($0.99) • When your register has been programmed for the automatic return mode (by the entered quantity. 31 Example Key operation p a Print Note The unit price of the set PLU (ex. When a set... by one item): Key operation 1 PPLU/ UPC ˘ 1 P SHIFT PLU/ UPC 2 PPLU/ UPC a Print • When your register has been programmed for the lock shift mode: Key operation 1 PPLU/ UPC ˘ 1 P SHIFT PLU/ UPC 2 PPLU/ UPC a Print Set PLU entries Operations are printed automatically....
... PLU price level 1: PLU 1 ($1.91), PLU 2 ($0.79) PLU price level 2: PLU 1 ($2.00), PLU 2 ($0.99) • When your register has been programmed for the automatic return mode (by the entered quantity. 31 Example Key operation p a Print Note The unit price of the set PLU (ex. When a set... by one item): Key operation 1 PPLU/ UPC ˘ 1 P SHIFT PLU/ UPC 2 PPLU/ UPC a Print • When your register has been programmed for the lock shift mode: Key operation 1 PPLU/ UPC ˘ 1 P SHIFT PLU/ UPC 2 PPLU/ UPC a Print Set PLU entries Operations are printed automatically....
ER-A410 | ER-A420 Operation Manual
Page 34
... the age limitation "17".) Key operation Print 100285 BIRTH 300 717 a When the preset option for "Birthday print availability (#2616)" is programmed as 98 years. [Ex.] When the current year is 2005 : you can enter the date as far back as "Allow", the birthday date is printed. ... or UPCs) for certain aged persons based on a registered birthday. When a department/PLU/UPC for which a figure other than zero (01 to 99) has been programmed as the age limitation is in effect. • You can enter the year 1907-2005.
... the age limitation "17".) Key operation Print 100285 BIRTH 300 717 a When the preset option for "Birthday print availability (#2616)" is programmed as 98 years. [Ex.] When the current year is 2005 : you can enter the date as far back as "Allow", the birthday date is printed. ... or UPCs) for certain aged persons based on a registered birthday. When a department/PLU/UPC for which a figure other than zero (01 to 99) has been programmed as the age limitation is in effect. • You can enter the year 1907-2005.
ER-A410 | ER-A420 Operation Manual
Page 35
... on a mix-and-match basis the following items in table no. 1 to a mix-and-match table. All items that are programmed into the same table are assigned to which is programmed in PGM mode is not changed (Price override entry). è Note For the repeat entry, use this function when you want...
... on a mix-and-match basis the following items in table no. 1 to a mix-and-match table. All items that are programmed into the same table are assigned to which is programmed in PGM mode is not changed (Price override entry). è Note For the repeat entry, use this function when you want...