... (10W Solar Panel) 12VDC Yes Yes Yes Yes 147 cycles Up to 24 days standby time Yes Approx. 22 cycles per day). LiftMaster® Gate Operators LA500DC Model Number Description LA5001PKGDC 24VDC Residential / Light Commercial Linear Actuator Photo of Gate Operator Security+ 2.0™ 3 ... 3 Years 16' 1000 lbs 250 RSL12VDC 12VDC Residential/Light Commercial DC Slide Gate Operator ELITE® SERIES COMMERCIAL GATE OPERATORS CSW24VDC CSL24VDC 24VDC High Traffic Commercial Swing Gate Operator 24VDC High Traffic Commercial Slide Gate Operator Yes 114 cycles Up to 63 days standby...
... (10W Solar Panel) 12VDC Yes Yes Yes Yes 147 cycles Up to 24 days standby time Yes Approx. 22 cycles per day). LiftMaster® Gate Operators LA500DC Model Number Description LA5001PKGDC 24VDC Residential / Light Commercial Linear Actuator Photo of Gate Operator Security+ 2.0™ 3 ... 3 Years 16' 1000 lbs 250 RSL12VDC 12VDC Residential/Light Commercial DC Slide Gate Operator ELITE® SERIES COMMERCIAL GATE OPERATORS CSW24VDC CSL24VDC 24VDC High Traffic Commercial Swing Gate Operator 24VDC High Traffic Commercial Slide Gate Operator Yes 114 cycles Up to 63 days standby...
DC Gate Operators Overview Brochure Manual
Page 2
...operator will power on auxiliary devices. Expansion board is optional on LA400DC, LA412DC, RSL12VDC, RSW12VDC, and standard on LA500DC, CSL24VDC, and CSW24VDC. • Plug-in Loops, Anti Tailgate, Quick Close, 3 second pre-motion warning and 2 programmable relays. Automatically learns the force ...). • Battery Backup safeguards your selection for 120V or 230V single phase (LA500DC, CSL24VDC, CSW24VDC). © 2014 LiftMaster All Rights Reserved 845 Larch Ave., Elmhurst, IL 60126 LiftMaster.com LMGTCTCOMP 6/14 Logs up , these best-in-class features come standard! • MyQ®...
...operator will power on auxiliary devices. Expansion board is optional on LA400DC, LA412DC, RSL12VDC, RSW12VDC, and standard on LA500DC, CSL24VDC, and CSW24VDC. • Plug-in Loops, Anti Tailgate, Quick Close, 3 second pre-motion warning and 2 programmable relays. Automatically learns the force ...). • Battery Backup safeguards your selection for 120V or 230V single phase (LA500DC, CSL24VDC, CSW24VDC). © 2014 LiftMaster All Rights Reserved 845 Larch Ave., Elmhurst, IL 60126 LiftMaster.com LMGTCTCOMP 6/14 Logs up , these best-in-class features come standard! • MyQ®...
CSL24VDC Solar Chart Manual
Page 1
...is provided to ensure proper operation. Solar panels should be located in climates where temperatures reach below -4°F. LA500DC LA412DC LA400DC CSW24VDC CSL24VDC RSW12VDC RSL12VDC The number of the country. Snow, heavy fog or heavy rain affect solar panel performance and charge rate. ... whether the application is due to the operator control board. Solar panel(s) must be cleaned regularly to the gate operator via batteries. LiftMaster Gate Operators utilizing the solar option are charged from a solar panel(s) connected to the effect of cold weather on batteries and a ...
...is provided to ensure proper operation. Solar panels should be located in climates where temperatures reach below -4°F. LA500DC LA412DC LA400DC CSW24VDC CSL24VDC RSW12VDC RSL12VDC The number of the country. Snow, heavy fog or heavy rain affect solar panel performance and charge rate. ... whether the application is due to the operator control board. Solar panel(s) must be cleaned regularly to the gate operator via batteries. LiftMaster Gate Operators utilizing the solar option are charged from a solar panel(s) connected to the effect of cold weather on batteries and a ...
CSL24VDC Solar Chart Manual
Page 5
...can be plugged in to determine total current draw. System voltage Main board with no radios learned (mA) One or more LiftMaster® transmitters learned (mA) MyQ® device or wireless dual gate learned (mA) Expansion board (mA) Per loop ...detector LOOPDETLM (up current draw by control board feature 24v (CSW24VDC, CSL24VDC) configurations. CSW24VDC / CSL24VDC Current consumption by feature and accessory to the expansion board) (mA) 24v 2.7 +1 +2.4 +11.1 +3.8 * Estimated based on use with LiftMaster transmitters CSW 24VDC Gate solar cycles per day Battery current draw...
...can be plugged in to determine total current draw. System voltage Main board with no radios learned (mA) One or more LiftMaster® transmitters learned (mA) MyQ® device or wireless dual gate learned (mA) Expansion board (mA) Per loop ...detector LOOPDETLM (up current draw by control board feature 24v (CSW24VDC, CSL24VDC) configurations. CSW24VDC / CSL24VDC Current consumption by feature and accessory to the expansion board) (mA) 24v 2.7 +1 +2.4 +11.1 +3.8 * Estimated based on use with LiftMaster transmitters CSW 24VDC Gate solar cycles per day Battery current draw...
CSL24VDC Solar Chart Manual
Page 6
... SUPPLY FOR COLD WEATHER APPLICATIONS Gate Operator Optional Power Supply LA500DC, LA412DC, LA400DC XLSOLARCONTDC ((2) 33-AH batteries not included) CSW24VDC, CSL24VDC (2) 33-AH batteries recommended in lieu of standard 7-AH batteries RSW12VDC, RSL12VDC (1) 33-AH batteries recommended in climates... standard 7-AH batteries For technical questions on solar installations, please contact LiftMaster Technical Support 800.528.6563 © 2014 LiftMaster All Rights Reserved 845 Larch Ave., Elmhurst, IL 60126 LiftMaster.com LMGTCTSLGD 6/14 Cycle rate may vary from solar chart for applications...
... SUPPLY FOR COLD WEATHER APPLICATIONS Gate Operator Optional Power Supply LA500DC, LA412DC, LA400DC XLSOLARCONTDC ((2) 33-AH batteries not included) CSW24VDC, CSL24VDC (2) 33-AH batteries recommended in lieu of standard 7-AH batteries RSW12VDC, RSL12VDC (1) 33-AH batteries recommended in climates... standard 7-AH batteries For technical questions on solar installations, please contact LiftMaster Technical Support 800.528.6563 © 2014 LiftMaster All Rights Reserved 845 Larch Ave., Elmhurst, IL 60126 LiftMaster.com LMGTCTSLGD 6/14 Cycle rate may vary from solar chart for applications...
CSW24VDC Sell Sheet Manual
Page 1
... and safeguards your gate from any room in interference eliminating Security+ 2.0™ radio. One button can control garage door(s). CSW24VDC COMMERCIAL HIGH TRAFFIC DC SWING GATE OPERATOR Unrivaled Performance, Security and Accessibility Engineered for more than a million cycles in high-.... Solar Panel (SOLPNL10W12V) Solar option available. No one else can offer you can access your facility. OPTIONAL ACCESSORIES: LiftMaster Internet Gateway (828LM)*** Receive alerts or monitor and activate gate via an Internet-enabled device anywhere in length or weighing ...
... and safeguards your gate from any room in interference eliminating Security+ 2.0™ radio. One button can control garage door(s). CSW24VDC COMMERCIAL HIGH TRAFFIC DC SWING GATE OPERATOR Unrivaled Performance, Security and Accessibility Engineered for more than a million cycles in high-.... Solar Panel (SOLPNL10W12V) Solar option available. No one else can offer you can access your facility. OPTIONAL ACCESSORIES: LiftMaster Internet Gateway (828LM)*** Receive alerts or monitor and activate gate via an Internet-enabled device anywhere in length or weighing ...
CSW24VDC Sell Sheet Manual
Page 2
... off devices at open upon loss of AC power or battery depletion. ADVANCED TRAFFIC MANAGEMENT CONTROL Secures your property. LiftMaster low power draw accessories recommended to make design or specification changes without notice. WARRANTY Five years commercial. WORM GEAR REDUCTION... Two commercial oil bath gear boxes providing 900:1 worm gear reduction. CSW24VDC COMMERCIAL HIGH TRAFFIC DC SWING GATE OPERATOR LED DIAGNOSTIC DISPLAY Easy-to 50 remotes. SURGE Industrial strength suppression on ...
... off devices at open upon loss of AC power or battery depletion. ADVANCED TRAFFIC MANAGEMENT CONTROL Secures your property. LiftMaster low power draw accessories recommended to make design or specification changes without notice. WARRANTY Five years commercial. WORM GEAR REDUCTION... Two commercial oil bath gear boxes providing 900:1 worm gear reduction. CSW24VDC COMMERCIAL HIGH TRAFFIC DC SWING GATE OPERATOR LED DIAGNOSTIC DISPLAY Easy-to 50 remotes. SURGE Industrial strength suppression on ...
CSW24VDC Installation Manual
Page 46
NOTE: Input solar power is not in use to see performance trade-offs. Cycle rate may vary. SOLAR USAGE GUIDE The CSW24VDC has best in class solar performance due to the main control board's accessory power output will draw 3.7 mA from the batteries while the system is ... 877 147 877 146 876 146 876 146 876 146 876 146 876 146 875 145 874 144 871 143 868 140 862 We recommend LiftMaster low power draw accessories to minimize power draw, refer to cold weather and a reduced number of hours of AC power BATTERY CURRENT DRAW (mA) SYSTEM...
NOTE: Input solar power is not in use to see performance trade-offs. Cycle rate may vary. SOLAR USAGE GUIDE The CSW24VDC has best in class solar performance due to the main control board's accessory power output will draw 3.7 mA from the batteries while the system is ... 877 147 877 146 876 146 876 146 876 146 876 146 876 146 875 145 874 144 871 143 868 140 862 We recommend LiftMaster low power draw accessories to minimize power draw, refer to cold weather and a reduced number of hours of AC power BATTERY CURRENT DRAW (mA) SYSTEM...
CSW24VDC Installation Manual
Page 55
...lighting accessories enabled by entering a 4-digit code on a specially designed keypad. Model 828LM 54 Includes mounting brackets. Posts not included. LiftMaster low power accessory. Models AOMRON E3K-R10K4-NR (retro-reflective) and RETROAB 60-2728 (retro-reflective) SENSING EDGE (2-WIRE, NON-... can be programmed to 4-button, visor or key chain. Model 877MAX MISCELLANEOUS POST-MOUNTING PLATE For post-mounting model CSW24VDC commercial swing operator (also CSW200 commercial swing operator). Model STAR450-315 PLUG-IN LOOP DETECTOR Conveniently plugs into existing control...
...lighting accessories enabled by entering a 4-digit code on a specially designed keypad. Model 828LM 54 Includes mounting brackets. Posts not included. LiftMaster low power accessory. Models AOMRON E3K-R10K4-NR (retro-reflective) and RETROAB 60-2728 (retro-reflective) SENSING EDGE (2-WIRE, NON-... can be programmed to 4-button, visor or key chain. Model 877MAX MISCELLANEOUS POST-MOUNTING PLATE For post-mounting model CSW24VDC commercial swing operator (also CSW200 commercial swing operator). Model STAR450-315 PLUG-IN LOOP DETECTOR Conveniently plugs into existing control...
CSW24VDC Installation Manual
Page 56
...or workmanship for warranty repair, which vary from defect in its entirety. You will void this product is originally installed, that the CSW24VDC is dependent on how long an implied warranty lasts, so the above limitation or exclusion may also have other rights which upon ...receipt by this product appears to state. 01-37010C 845 Larch Avenue Elmhurst, Illinois 60126-1196 LiftMaster.com © 2013, LiftMaster - Products returned to Seller for a period of 7 year residential/ 5 year commercial from the date of -purchase receipt with those...
...or workmanship for warranty repair, which vary from defect in its entirety. You will void this product is originally installed, that the CSW24VDC is dependent on how long an implied warranty lasts, so the above limitation or exclusion may also have other rights which upon ...receipt by this product appears to state. 01-37010C 845 Larch Avenue Elmhurst, Illinois 60126-1196 LiftMaster.com © 2013, LiftMaster - Products returned to Seller for a period of 7 year residential/ 5 year commercial from the date of -purchase receipt with those...