Owner's Manual
Page 1
Installation Guide ENGLISH See page 2 Español Vea la página 21 90052/90053/90054/90058 Saturn™ Bath Ventilator with Light READ and SAVE THESE INSTRUCTIONS 028_41718_EngS_1.28.08_Arial.indd 1 1 41718-01 01/28/2008 1/28/08 10:47:06 AM
Installation Guide ENGLISH See page 2 Español Vea la página 21 90052/90053/90054/90058 Saturn™ Bath Ventilator with Light READ and SAVE THESE INSTRUCTIONS 028_41718_EngS_1.28.08_Arial.indd 1 1 41718-01 01/28/2008 1/28/08 10:47:06 AM
Owner's Manual
Page 2
... the local code authorities. 2. Install fan at least 5 feet (1.52 m) above the floor. 10. CAUTION 1. Do not use abrasive cloths, steel wool pads or scouring powders. Gently vacuum fan, motor and interior of the housing or insert a screwdriver into wall(s) or ceiling, do not damage electrical wiring or other hidden utilities. 6. If the motor bearings are making excessive or unusual noises, replace the motor with all...
... the local code authorities. 2. Install fan at least 5 feet (1.52 m) above the floor. 10. CAUTION 1. Do not use abrasive cloths, steel wool pads or scouring powders. Gently vacuum fan, motor and interior of the housing or insert a screwdriver into wall(s) or ceiling, do not damage electrical wiring or other hidden utilities. 6. If the motor bearings are making excessive or unusual noises, replace the motor with all...
Owner's Manual
Page 3
...01-000 F 75191-01-000 G 03242-07-133 H 95491-01-000 x2 I Extra Screws * NOTE: Strain relief cable connector must be installed. If damaged, call 1-888-830-1326 for replacements. x4 A *B *C 3/8" Cable Connector x2 I 74508-03-133 J 77521-01 K 65219 L 95583-01/02/03/04-000.... Check all packing materials before installation. 2 I E Turn off the power source. 028_41718_EngS_1.28.08_Arial.indd 3 3 41718-01 01/28/2008 Loosen screws. 1/28/08 10:47:09 AM Before Installation 1 Tools Needed. (Not supplied) Estimated assembly time: 30 to 60 minutes NOTE: Remove all the parts.
...01-000 F 75191-01-000 G 03242-07-133 H 95491-01-000 x2 I Extra Screws * NOTE: Strain relief cable connector must be installed. If damaged, call 1-888-830-1326 for replacements. x4 A *B *C 3/8" Cable Connector x2 I 74508-03-133 J 77521-01 K 65219 L 95583-01/02/03/04-000.... Check all packing materials before installation. 2 I E Turn off the power source. 028_41718_EngS_1.28.08_Arial.indd 3 3 41718-01 01/28/2008 Loosen screws. 1/28/08 10:47:09 AM Before Installation 1 Tools Needed. (Not supplied) Estimated assembly time: 30 to 60 minutes NOTE: Remove all the parts.
Owner's Manual
Page 4
3 4 H E Remove the motor/blower from the housing. 5 Remove packing material. 6 Remove the pre-loaded screw tip covers. 7 G Back out the pre-loaded screw tips until flush with the side of the housing. 8 F Remove the wiring cover screw. 4 41718-01 01/28/2008 028_41718_EngS_1.28.08_Arial.indd 4 Remove the wiring cover. 1/28/08 10:47:11 AM
3 4 H E Remove the motor/blower from the housing. 5 Remove packing material. 6 Remove the pre-loaded screw tip covers. 7 G Back out the pre-loaded screw tips until flush with the side of the housing. 8 F Remove the wiring cover screw. 4 41718-01 01/28/2008 028_41718_EngS_1.28.08_Arial.indd 4 Remove the wiring cover. 1/28/08 10:47:11 AM
Owner's Manual
Page 5
Use second if needed. suspended between joists go to step C11, page 11 For Existing Construction - accessible from below go to joist A11 A12 E 5/8 5/8 1/2 1/2 Position the correct depth mark ... 10:47:13 AM attaching to joist go to step B11, page 8 For Existing Construction - Screw pre-loaded screws into the housing and secure with the washer. Choose Installation Option For New Construction - attaching to step A11, page 5 For New Construction - 9 10 E C Pop out the first wiring access slug. accessible only from above go to step D11, page15...
Use second if needed. suspended between joists go to step C11, page 11 For Existing Construction - accessible from below go to joist A11 A12 E 5/8 5/8 1/2 1/2 Position the correct depth mark ... 10:47:13 AM attaching to joist go to step B11, page 8 For Existing Construction - Screw pre-loaded screws into the housing and secure with the washer. Choose Installation Option For New Construction - attaching to step A11, page 5 For New Construction - 9 10 E C Pop out the first wiring access slug. accessible only from above go to step D11, page15...
Owner's Manual
Page 6
... ducting does not fit securely, an adapter may need to the outside. Make sure all wiring connections are inside the box or under the wiring cover plate. A15 A016 E G Install the wiring cover plate. A14 Fan Motor Light Black 2 Pin White White 3 Pin Black Light *Option *Option Fan & Main Light Together Ground Green A Bare Copper Black Main Switch 1 (AC In) White Black Switch 2 (AC In) Connect wires as shown. Connect 4" duct and vent to be purchased. 6 41718-01 01...
... ducting does not fit securely, an adapter may need to the outside. Make sure all wiring connections are inside the box or under the wiring cover plate. A15 A016 E G Install the wiring cover plate. A14 Fan Motor Light Black 2 Pin White White 3 Pin Black Light *Option *Option Fan & Main Light Together Ground Green A Bare Copper Black Main Switch 1 (AC In) White Black Switch 2 (AC In) Connect wires as shown. Connect 4" duct and vent to be purchased. 6 41718-01 01...
Owner's Manual
Page 7
A21 ON A22 Go to step E1 OFF on the power source. Make sure the wires are not pinched between the motor and the housing. A19 H Reinstall the motor by tightening the 2 screws. A20 I Secure the motor by inserting the tabs and pushing up into position. Turn on page 17 to the wiring cover plate. If the motor does not run, check the plug connection. 7 41718-01 01/28/2008 028_41718_EngS_1.28.08_Arial.indd 7 1/28/08 10:47:18 AM A17 0 A18 0 Connect wiring from the motor to attach grille. Test the motor.
A21 ON A22 Go to step E1 OFF on the power source. Make sure the wires are not pinched between the motor and the housing. A19 H Reinstall the motor by tightening the 2 screws. A20 I Secure the motor by inserting the tabs and pushing up into position. Turn on page 17 to the wiring cover plate. If the motor does not run, check the plug connection. 7 41718-01 01/28/2008 028_41718_EngS_1.28.08_Arial.indd 7 1/28/08 10:47:18 AM A17 0 A18 0 Connect wiring from the motor to attach grille. Test the motor.
Owner's Manual
Page 8
B15 B16 Insert screws, leaving space between joists B11 B12 E D Slide the mounting rails into brackets. 5/8 5/8 1/2 1/2 Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. Screws are not provided. 8 41718-01 01/28/2008 Attach the rails onto the screws. 028_41718_EngS_1.28.08_Arial.indd 8 1/28/08 10:47:21 AM Drill a hole in the center of screws by using holes as a template. New Construction - suspended between the screw head and the joist. B13 B14 E 1/8" Bit Mark position of each outline.
B15 B16 Insert screws, leaving space between joists B11 B12 E D Slide the mounting rails into brackets. 5/8 5/8 1/2 1/2 Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. Screws are not provided. 8 41718-01 01/28/2008 Attach the rails onto the screws. 028_41718_EngS_1.28.08_Arial.indd 8 1/28/08 10:47:21 AM Drill a hole in the center of screws by using holes as a template. New Construction - suspended between the screw head and the joist. B13 B14 E 1/8" Bit Mark position of each outline.
Owner's Manual
Page 9
... be purchased. 9 41718-01 01/28/2008 028_41718_EngS_1.28.08_Arial.indd 9 1/28/08 10:47:24 AM If ducting does not fit securely, an adapter may need to the outside. B19 Fan Motor Light Black 2 Pin White White 3 Pin Black Light *Option *Option Fan & Main Light Together Ground Green A Bare Copper Black Main Switch 1 (AC In) White Black Switch 2 (AC In) Connect wires as shown. B20 B21 F G Install the wiring cover plate...
... be purchased. 9 41718-01 01/28/2008 028_41718_EngS_1.28.08_Arial.indd 9 1/28/08 10:47:24 AM If ducting does not fit securely, an adapter may need to the outside. B19 Fan Motor Light Black 2 Pin White White 3 Pin Black Light *Option *Option Fan & Main Light Together Ground Green A Bare Copper Black Main Switch 1 (AC In) White Black Switch 2 (AC In) Connect wires as shown. B20 B21 F G Install the wiring cover plate...
Owner's Manual
Page 10
B24 B25 I Secure the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. B22 B23 H H Connect wiring from the motor to attach grille. B26 ON B27 Go to step E1 OFF on the power source. Turn on page 17 to the wiring cover plate. If the motor does not run, check the plug connection. 10 41718-01 01/28/2008 028_41718_EngS_1.28.08_Arial.indd 10 1/28/08 10:47:27 AM Test the motor. Reinstall the motor by tightening the 2 screws.
B24 B25 I Secure the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. B22 B23 H H Connect wiring from the motor to attach grille. B26 ON B27 Go to step E1 OFF on the power source. Turn on page 17 to the wiring cover plate. If the motor does not run, check the plug connection. 10 41718-01 01/28/2008 028_41718_EngS_1.28.08_Arial.indd 10 1/28/08 10:47:27 AM Test the motor. Reinstall the motor by tightening the 2 screws.
Owner's Manual
Page 11
... bottom edge of the joist based on the thickness of screws by using holes as a template to mark position. Existing Construction - Mark position of your sheetrock. C13 Slide the mounting rails into brackets. C12 E D Cut out an opening is large enough to accommodate the new motor housing (8"x 8.5"). 8" 8.5" Use the motor housing as a template. 11 41718-01 01/28/2008 028_41718_EngS_1.28...
... bottom edge of the joist based on the thickness of screws by using holes as a template to mark position. Existing Construction - Mark position of your sheetrock. C13 Slide the mounting rails into brackets. C12 E D Cut out an opening is large enough to accommodate the new motor housing (8"x 8.5"). 8" 8.5" Use the motor housing as a template. 11 41718-01 01/28/2008 028_41718_EngS_1.28...
Owner's Manual
Page 12
C18 Attach the rails onto the screws. C19 Tighten screws. If ducting does not fit securely, an adapter may need to the outside. C17 Insert screws, leaving space between the screw head and the joist. C20 Connect 4" duct and vent to be purchased. 12 41718-01 01/28/2008 Pull wires through the strain relief. 028_41718_EngS_1.28.08_Arial.indd 12 1/28/08 10:47:33 AM Tape joints. Screws are not provided. C15 C16 1/8" Bit Drill a hole in the center of each outline.
C18 Attach the rails onto the screws. C19 Tighten screws. If ducting does not fit securely, an adapter may need to the outside. C17 Insert screws, leaving space between the screw head and the joist. C20 Connect 4" duct and vent to be purchased. 12 41718-01 01/28/2008 Pull wires through the strain relief. 028_41718_EngS_1.28.08_Arial.indd 12 1/28/08 10:47:33 AM Tape joints. Screws are not provided. C15 C16 1/8" Bit Drill a hole in the center of each outline.
Owner's Manual
Page 13
C23 C24 F H G Install the wiring cover plate. C22 Fan Motor Light Black 2 Pin White White 3 Pin Black Light *Option *Option Fan & Main Light Together Ground Green A Bare Copper Black Main Switch 1 (AC In) White Black Switch 2 (AC In) Connect wires as shown. Make sure all wiring connections are inside the box or under the wiring cover plate. 13 41718-01 01/28/2008 Connect wiring from the motor to the wiring cover plate. 028_41718_EngS_1.28.08_Arial.indd 13 1/28/08 10:47:35 AM C21 Tighten the strain relief screws.
C23 C24 F H G Install the wiring cover plate. C22 Fan Motor Light Black 2 Pin White White 3 Pin Black Light *Option *Option Fan & Main Light Together Ground Green A Bare Copper Black Main Switch 1 (AC In) White Black Switch 2 (AC In) Connect wires as shown. Make sure all wiring connections are inside the box or under the wiring cover plate. 13 41718-01 01/28/2008 Connect wiring from the motor to the wiring cover plate. 028_41718_EngS_1.28.08_Arial.indd 13 1/28/08 10:47:35 AM C21 Tighten the strain relief screws.
Owner's Manual
Page 14
C27 C28 ON OFF Turn on page 17 to attach grille. C25 C26 H Reinstall the motor by tightening the 2 screws. C29 Go to step E1 on the power source. I Secure the motor by inserting the tabs and pushing up into position. If the motor does not run, check the plug connection. 028_41718_EngS_1.28.08_Arial.indd 14 14 41718-01 01/28/2008 1/28/08 10:47:38 AM Test the motor. Make sure the wires are not pinched between the motor and the housing.
C27 C28 ON OFF Turn on page 17 to attach grille. C25 C26 H Reinstall the motor by tightening the 2 screws. C29 Go to step E1 on the power source. I Secure the motor by inserting the tabs and pushing up into position. If the motor does not run, check the plug connection. 028_41718_EngS_1.28.08_Arial.indd 14 14 41718-01 01/28/2008 1/28/08 10:47:38 AM Test the motor. Make sure the wires are not pinched between the motor and the housing.
Owner's Manual
Page 15
D13 Move the housing into joist or framing. 15 41718-01 01/28/2008 028_41718_EngS_1.28.08_Arial.indd 15 1/28/08 10:47:40 AM Existing Construction - Tape joints. D15 Attach existing ducting to be purchased. D14 2 1 Pull wires through strain relief. If ducting does not fit securely, an adapter may need to duct connector. accessible only from below D11 EXISTING FAN D12 E Remove an existing fan and check to make sure the opening is large enough to accommodate the new motor housing (8"x 8.5"). E Screw pre-loaded screws into position above the ceiling.
D13 Move the housing into joist or framing. 15 41718-01 01/28/2008 028_41718_EngS_1.28.08_Arial.indd 15 1/28/08 10:47:40 AM Existing Construction - Tape joints. D15 Attach existing ducting to be purchased. D14 2 1 Pull wires through strain relief. If ducting does not fit securely, an adapter may need to duct connector. accessible only from below D11 EXISTING FAN D12 E Remove an existing fan and check to make sure the opening is large enough to accommodate the new motor housing (8"x 8.5"). E Screw pre-loaded screws into position above the ceiling.
Owner's Manual
Page 16
... motor by tightening the 2 screws. 41718-01 01/28/2008 028_41718_EngS_1.28.08_Arial.indd 16 1/28/08 10:47:43 AM Make sure the wires are inside the box or under the wiring cover plate. D17 D18 F G Install the wiring cover plate. D16 Fan Motor Light 2 Pin Black White White 3 Pin Black Light *Option *Option Fan & Main Light Together Ground Green A Bare Copper Black Main Switch 1 (AC In) White Black Switch 2 (AC In) Connect wires...
... motor by tightening the 2 screws. 41718-01 01/28/2008 028_41718_EngS_1.28.08_Arial.indd 16 1/28/08 10:47:43 AM Make sure the wires are inside the box or under the wiring cover plate. D17 D18 F G Install the wiring cover plate. D16 Fan Motor Light 2 Pin Black White White 3 Pin Black Light *Option *Option Fan & Main Light Together Ground Green A Bare Copper Black Main Switch 1 (AC In) White Black Switch 2 (AC In) Connect wires...
Owner's Manual
Page 17
D21 Turn on page 17 to attach grille. D23 Go to step E1 on the power source. Attaching the Grille E1 E2 E M L Remove the thumbscrews. 028_41718_EngS_1.28.08_Arial.indd 17 17 41718-01 01/28/2008 Connect wiring harness. 1/28/08 10:47:45 AM D22 ON OFF Test the motor. If the motor does not run, check the plug connection.
D21 Turn on page 17 to attach grille. D23 Go to step E1 on the power source. Attaching the Grille E1 E2 E M L Remove the thumbscrews. 028_41718_EngS_1.28.08_Arial.indd 17 17 41718-01 01/28/2008 Connect wiring harness. 1/28/08 10:47:45 AM D22 ON OFF Test the motor. If the motor does not run, check the plug connection.
Owner's Manual
Page 18
.... Slide light fixture over the lip of electrical shock, all 4 thumbscrews MUST be properly installed. 18 Install 2 Max 60 watt A-15 bulbs (Not Included). 41718-01 01/28/2008 028_41718_EngS_1.28.08_Arial.indd 18 1/28/08 10:47:48 AM E3 E4 J K Remove the strain relief bracket screw. E7 Align posts A, B, C and D (stamped into motor housing) with posts A, B, C and D (stamped into light fixture...
.... Slide light fixture over the lip of electrical shock, all 4 thumbscrews MUST be properly installed. 18 Install 2 Max 60 watt A-15 bulbs (Not Included). 41718-01 01/28/2008 028_41718_EngS_1.28.08_Arial.indd 18 1/28/08 10:47:48 AM E3 E4 J K Remove the strain relief bracket screw. E7 Align posts A, B, C and D (stamped into motor housing) with posts A, B, C and D (stamped into light fixture...
Owner's Manual
Page 19
... light bulb with a new bulb. • T urn power on , replace fuse, or reset breaker. • Check all fasteners. • C heck the glass to make sure it is secure. • C heck the flapper to make sure it moves freely. E9 E10 N Align glass dome and push up. To confirm that the fan is noisy. Trouble Shooting Problem: Fan does not come on . If you need parts or service...
... light bulb with a new bulb. • T urn power on , replace fuse, or reset breaker. • Check all fasteners. • C heck the glass to make sure it is secure. • C heck the flapper to make sure it moves freely. E9 E10 N Align glass dome and push up. To confirm that the fan is noisy. Trouble Shooting Problem: Fan does not come on . If you need parts or service...
Owner's Manual
Page 20
... if your Hunter bath exhaust fan is required when requesting warranty service. Warranty Hunter Fan Company Bath Exhaust Fan LIMITED WARRANTY Hunter Fan Company makes the following limited warranty to the original user or consumer purchaser of this Hunter bath exhaust fan: If any part of your Hunter bath exhaust fan (except for glass fixtures and light bulbs) fails at any Hunter bath exhaust fan which were caused by repairs by persons not authorized by us, use of parts or accessories not authorized by us, mishandling, improper installation, modifications or...
... if your Hunter bath exhaust fan is required when requesting warranty service. Warranty Hunter Fan Company Bath Exhaust Fan LIMITED WARRANTY Hunter Fan Company makes the following limited warranty to the original user or consumer purchaser of this Hunter bath exhaust fan: If any part of your Hunter bath exhaust fan (except for glass fixtures and light bulbs) fails at any Hunter bath exhaust fan which were caused by repairs by persons not authorized by us, use of parts or accessories not authorized by us, mishandling, improper installation, modifications or...